Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical cables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Lightning tests and analyses of tunnel bond straps and shielded cables on the Space Shuttle solid rocket booster

The purposes of the tests and analyses described in this report are as follows: (1) determine the lightning current survivability of five alternative changed designs of the bond straps which electrically bond the solid rocket booster (SRB) systems tunnel to the solid rocket motor (SRM) case; (2) determine the amount of reduction in induced voltages on operational flight (OF) tunnel cables obtained by a modified design of tunnel bond straps (both tunnel cover-to-cover and cover-to-motor case); (3) determine the contribution of coupling to the OF tunnel cables by ground electrical and instrumentation (GEI) cables which enter the systems tunnel from unshielded areas on the surfaces of the motor case; and (4) develop a model (based on test data) and calculate the voltage levels at electronic 'black boxes' connected to the OF cables that run in the systems tunnel.

Druen, William M.↗

Design considerations for high-power VHF radar transceivers: Phase matching long coaxial cables using a cable radar

The Poker Flat 49.92-MHz MST radar uses 64 phase-controlled transmitters in individual shelters distributed throughout the antenna array. Phase control is accomplished by sampling the transmitted pulse at the directional coupler of each transmitter and sending the sample pulse back to a phase-control unit. This method requires phase matching 64 long (256 meter) coaxial cables (RG-213) to within several electrical degrees. Tests with a time domain reflectometer showed that attenuation of high frequency components in the long RG-213 cable rounded the leading edge of the reflected pulse so that the cables could only be measured to within 50 cm (about 45 deg at 49.92 MHz). Another measurement technique using a vector voltmeter to compare forward and reflected phase required a directional coupler with unattainable directivity. Several other techniques were also found lacking, primarily because of loss in the long RG-213 cables. At this point it was realized that what was needed was a simple version of the phase-coherent clear-air radar, i.e., a cable radar. The design and operation of this cable are described.

Johnson, P. E.↗

Active Reduction of Apparent Cable Capacitance

This paper presents a method for reducing apparent cable capacitance seen by sensors. The proposed method is designed for sensing in extreme environments including ultra-high temperatures, but can be applied in benign environments as well. By reducing the cable capacitance, high speed signals can be transmitted over longer distances, allowing the application of advanced control systems that require high bandwidth data for stable operation. A triaxial cable with an associated guard circuit is developed that actively reduces cable capacitance while also rejecting extraneous electric and magnetic interference on the signal. The active capacitance reduction method developed is tested experimentally and shown to reduce apparent cable capacitance to two percent of the static value.

47 OTHER INSTRUMENTATION↗

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model↗

Remote lightning monitor system

An apparatus for monitoring, analyzing and accurately determining the value of peak current, the peak rate of change in current with respect to time and the rise time of the electrical currents generated in an electrical conductive mast that is located in the vicinity where lightning is to be monitored is described. The apparatus includes an electrical coil for sensing the change in current flowing through the mast and generating a voltage responsive. An on-site recorder and a recorder control system records the voltages produced responsive to lightning strikes and converts the voltage to digital signals for being transmitted back to the remote command station responsive to command signals. The recorder and the recorder control system are carried within an RFI proof environmental housing into which the command signals are fed by means of a fiber optic cable so as to minimize electrical interference.

Lennon, C. L.↗

Assessment of EPRI’s Tan Delta Approach to Manage Cables in Submerged Environments: Statistical Review of EPRI Data

Research conducted by the Electric Power Research Institute (EPRI) and other research institutions have concluded that water-trees are one of the leading degradation mechanisms that contribute to the loss of dielectric insulation strength in medium-voltage cable insulating materials in wet or submerged environments. The electrochemical reactions are caused by the combined effect of water presence and relatively high electrical stress. Records of cable failures provided by the licensees in response to Generic Letter (GL) 2007-01 (NRC 2007) have called into question the reliability of medium voltage cables in wetted or submerged environments. EPRI’s dissipation factor or Tan Delta testing guidelines and acceptance criteria have been adopted by most nuclear power plant operators as the primary tool for condition monitoring of medium voltage cables in wet or submerged environments. EPRI has been collecting member data since late 2009 to analyze and provide feedback to members, validate the EPRI-developed acceptance criteria guidelines, support analysis of test results, recommend appropriate actions for the "action required" category, and gather candidate cables for EPRI-sponsored forensic research on causes for insulation degradation. EPRI has collected data from 37 nuclear sites, which represent 44 operating units. The test results have been organized by insulation type, such as cross-linked polyethylene (XLPE); butyl rubber; black, pink, and brown ethylene-propylene rubber (EPR); and compact insulation (black and pink EPR)1. The data have been analyzed, and follow-up information was obtained from members for “action required” test results. EPRI has also performed correlations between Tan Delta tests and the information gathered under the EPRI forensic research on medium-voltage cables. In addition, EPRI has developed guidance by cable insulation type on how to systematically analyze Tan Delta test results. The analysis described here reviewed the two primary EPRI reports (EPRI 3002000557 and EPRI 3002005321) as well as two precedent EPRI reports (EPRI 1028262 and EPRI 1021070) that were cited in the primary reports. The principal results and conclusions from the project analyses are provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of the power potential for surface- and seabed-deployed tidal turbines in the San Juan Archipelago, Salish Sea, WA

The San Juan archipelago lies along the axis of tidal movement between Straits of Juan de Fuca and Strait of Georgia in the Salish Sea. The amplitude of the tidal exchange produces significant tidal currents between the islands, as well as in Rosario and Haro Straits. These are of interest as a future source of electrical power generation, given the islands’ dependence on electricity supply by a subsea cable from the mainland. Here, we evaluate the tidal current energy potential in this region through a re-analysis of measurements collected by the National Ocean Service (NOS) and a high-resolution numerical model. Given the considerable variations in water depth and vertical velocity profiles across candidate tidal energy sites, we consider the trade-offs between tidal turbines deployed from a floating platform and those anchored to the seabed. Measurement re-analysis indicates several locations that could support tidal current power generation by MW-scale turbines with an acceptable balance between turbine size, rated power, and capacity factor. Even for relatively large (30 m) turbine diameters, surface-deployed turbines would be expected to produce up to 30 % more electricity than the same turbine deployed near the seabed due to vertical shear, with this difference increasing for smaller diameter turbines. A benchmark comparison at the measurement locations with the highest power generation potential shows relatively good model fidelity, though, even with relatively high resolution, time-average power density disagreements of ± 50 % persist throughout the water column. Nonetheless, the simulation identifies several locations with power generation potential more than twice as high as locations in the measurement re-analysis. These sites were either not surveyed by NOS or excluded due to data quality issues. Altogether, these results demonstrate the complimentary of models and measurements for tidal energy site assessment and suggest that tidal currents could be an important source of electricity generation in the San Juan archipelago.

16 TIDAL AND WAVE POWER↗

Breakaway electrical connector

One-shot, breakaway multiwire cable connector is fabricated by using a number of small-diameter interconnecting wires, each of which, differing incrementally in length, is welded to neighboring pin and cable terminations. This design eliminates frictional binding and provides highly reliable cable interconnections until the connector is disengaged.

Katzin, L.↗

Dust-Tolerant Intelligent Electrical Connection System

Faults in wiring systems are a serious concern for the aerospace and aeronautic (commercial, military, and civilian) industries. Circuit failures and vehicle accidents have occurred and have been attributed to faulty wiring created by open and/or short circuits. Often, such circuit failures occur due to vibration during vehicle launch or operation. Therefore, developing non-intrusive fault-tolerant techniques is necessary to detect circuit faults and automatically route signals through alternate recovery paths while the vehicle or lunar surface systems equipment is in operation. Electrical connector concepts combining dust mitigation strategies and cable diagnostic technologies have significant application for lunar and Martian surface systems, as well as for dusty terrestrial applications. The dust-tolerant intelligent electrical connection system has several novel concepts and unique features. It combines intelligent cable diagnostics (health monitoring) and automatic circuit routing capabilities into a dust-tolerant electrical umbilical. It retrofits a clamshell protective dust cover to an existing connector for reduced gravity operation, and features a universal connector housing with three styles of dust protection: inverted cap, rotating cap, and clamshell. It uses a self-healing membrane as a dust barrier for electrical connectors where required, while also combining lotus leaf technology for applications where a dust-resistant coating providing low surface tension is needed to mitigate Van der Waals forces, thereby disallowing dust particle adhesion to connector surfaces. It also permits using a ruggedized iris mechanism with an embedded electrodynamic dust shield as a dust barrier for electrical connectors where required.

Lewis, Mark↗

Operational characteristics of a 200 C LC parallel resonant circuit

Research efforts are currently underway at the NASA Lewis Research Center to design and demonstrate an inverter capable of operating with a baseplate temperature of 200 C. In support of this project, various electrical components including capacitors, inductors, transformers, cables, and semiconductor switches are being developed or evaluated for integration into the inverter. In this work, a parallel LC resonant circuit was constructed and evaluated under simultaneous electrical and thermal stressing. The tests were performed in the temperature range of 25 to 200 C with an applied voltage of up to 90 V, 20 kHz. The individual components were comprised of high temperature film capacitors and powder core inductors developed in-house. The circuit was characterized in terms of the component currents and case temperatures as well as frequency of resonance as a function of applied bias and temperature. The results obtained, which have indicated good functional stability up to 200 C, are presented and discussed.

Baumann, Eric D.↗

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]↗

Pyrotechnic-actuated cable release

Remote, unattended means has been designed and reduced to practice that retains and then releases an attached load by means of a restrained cable. The cable is released by an electrical impulse on signal.

Hanson, R. W.↗

Application of a flight-line disk crack detector to a small engine

A disk crack detector was developed and applied to a small military engine for use as a flight-line turbine crack monitor. The system consists of an eddy current type sensor and its cables within the engine, external connecting cables, and a remotely located electrical capacitance-conductance bridge and signal analyzer. As the turbine spins, the rotor is monitored by the sensor for radial surface cracks emanating from the interblade region of the rotor.

Barranger, J. P.↗

EVA Planning: Using Neutral Buoyancy Laboratory (NBL) Training to Predict in-Flight Energy Expenditure

Metabolic rate (“met rate”) is the amount of energy expended over a period of time and is influenced by many factors including body composition, level of physical activity, resting metabolic rate, sex, age, and food intake. Met rate is measured during Extravehicular Activity (EVA) training at the Neutral Buoyancy Laboratory (NBL) and during in-flight EVAs through indirect calorimetry, calculating energy expenditure from respiratory measurements of O 2 consumption and/or CO 2 production. During Extravehicular Activity (EVA) planning, metabolic cost is important to consider and is used to inform EVA duration based on spacesuit consumables associated with life support systems. Currently, NBL and previous ISS EVA met rate data for specified crewmembers are utilized to predict in-flight EVA metabolic costs based on a proposed EVA timeline. Timeline data collected during training is used to relate met rates to specific EVA activities, which are in turn assigned to more generalized EVA task categories, categorizing by both task type and restraint type. EVA task categories include EVA Setup/Cleanup, Worksite Setup/Cleanup, Cable Routing, Bolts, Fluid Connectors, Electrical Connectors, R&R Work, Miscellaneous Work, Incapacitated Crew Rescue (being rescued or performing), Assisted Crew Rescue (being assisted or performing), and Translation. Restraint types consist of Free-Float, Body Restraint Tether (BRT), Articulating Portable Foot Restraint (APFR), and Space Station Remote Manipulator System (SSRMS). From a crewmember’s historical data, individualized 10th, 50th and 90th percentile met rate estimates are generated for each task category and used to estimate the proposed EVA timeline metabolic cost. In-flight metabolic data (“As-Executed”) from recent ISS US EVAs 85-88 (totaling eight EVA crewmember met rates) was compared with their predicted metabolic cost (“As-Planned”) to evaluate the accuracy of the current met rate estimation method. Across the four EVAs, As-Executed Cumulative EVA Total Metabolic Cost (M = 5893.78 BTU, SD = 816.60) was not significantly different compared to As-Planned Cumulative EVA Total Metabolic Cost (M = 6106.60 BTU, SD = 826.62; t(7) = 0.751 , p = .477). Though not a significant difference, generally, As-Planned total estimates were slightly higher than As-Executed total metabolic cost. Relative Error for Cumulative EVA Total Metabolic Cost ranged from -33% to 14.7%, depending on the crewmember and EVA. When comparing As-Planned to A-Executed EVA task categories for Bolts, Electrical Connectors, EVA Cleanup, EVA Setup, Miscellaneous Work, Translation, Worksite Cleanup, and Worksite Setup during these EVAs, no significant differences were observed, however, there was a significant difference in As-Planned (M = 783.71 BTU, SD = 408.88) compared to As-Executed (M = 608.87 BTU, SD = 425.29) metabolic cost for the task category of Repair-and-Replace (R&R) Work (t(17) = 3.21 , p = .005). Looking closer within the R&R Work task category, As-Executed R&R Work with Free-Float restraint type (M = 706.17 BTU, SD = 352.18) was significantly less than As-Planned R&R Work with Free-Float restraint type (M= 887.96 BTU, SD = 381.42; t(12) = 2.59, p < .024). As-Executed R&R Work with SSRMS Restraint type (M = 355.89 BTU, SD = 534.65) was not significantly different from As-Planned values (M = 512.69 BTU, SD = 383.34; t(4) = 1.88, p = 0.132). These findings suggest that the energy expended performing R&R Work (Free-Float) is lower in flight than predicted. Accurate predictions of the metabolic cost of EVA are essential for planning and executing successful ISS EVAs. Overall, the current met rate prediction method is similar to actual in-flight values, slightly erring on the side of overestimation. Future work includes analysis of more historical in-flight EVA data to increase the power of the analysis, evaluating the NBL-ISS met rate conversion factor between NBL and ISS tasks, as well as exploring methods of substitution when crewmembers are missing prior task category data.

Lauren Cox↗

PIP-II LLRF Master Oscillator and Precision Reference Line- Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase synchronization throughout the accelerator. Temperature-induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the master oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods support repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago; Fermilab]↗

Vis-SAGA: Visual Analytics for Situational Awareness of Grid Anomalies: Preprint

We describe supporting near real-time situational awareness of the electric distribution system by visualizing novel data from voltage sensors deployed on existing broadband cable television network equipment. Our scalable web-based visual analytics platform supports interactive geospatial exploration, time-series analysis, and summarization of grid behavior during potentially anomalous events. The broadband cable television sensor network provides observability of the electrical distribution system at a higher local spatial resolution than is typically available to most utilities, revealing the operational state of the network and aiding in the detection of abnormal behaviors or deviations from expected patterns, particularly across electric utility service areas. We outline the design and development of interactive geospatial and time-series visualization components and the scalable data services that supply metadata, historical, and real-time streams of sensor data across the network. We evaluate our platform during periods of extreme weather, demonstrating its ability to assist in detecting patterns of operation that affect power availability, quality, resiliency, and service restoration.

cable television↗