Engineering PapersSearch

DOE OSTI · 3484567

PIP-II LLRF Master Oscillator and Precision Reference Line- Station Level Design and Testing

Abstract

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase synchronization throughout the accelerator. Temperature-induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the master oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods support repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mosher, Alexander [U. Illinois, Chicago; Fermilab]. 2026-08-20. PIP-II LLRF Master Oscillator and Precision Reference Line- Station Level Design and Testing. https://www.osti.gov/biblio/3484567