Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computational fluid dynamics simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Modeling the impact of the fuel injection strategy on the combustion and performance characteristics of a heavy-duty GCI engine

Gasoline compression ignition (GCI) is a promising strategy to achieve high thermal efficiency and low emissions with limited modifications to the conventional diesel engine hardware. It is a partially premixed concept, which derives its superiority from higher volatility and longer ignition delay of gasoline-like fuels combined with higher compression ratio typical of diesel engines. Here, the present study investigates the combustion process in a GCI engine operating with different injection strategies using computational fluid dynamics (CFD). Simulations are carried out on a single cylinder of a multi cylinder heavy-duty compression ignition engine, which operates at a compression ratio of 17:1 and an engine speed of 1038 rev/min. Two different injection strategies viz., late injection (LI), and early pilot injection (EP) are investigated to understand their impact on combustion and performance of the engine. Renormalized group (RNG) k-ε model is used to describe in-cylinder turbulence and KH RT model is used to simulate the fuel spray breakup. The developed CFD methodology is validated against relevant experimental data under a wide range of operating conditions for each injection strategy. The developed CFD methodology was found to capture the engine combustion behavior quite well. Based on the validated CFD model, the differences in the progress of combustion event for the two injection strategies is highlighted. It was found that a larger pilot fuel mass fraction results in a steeper rise in the initial heat release rate which in turn influences the transition to mixing controlled combustion. In line with the experimental data, the study showed that the late pilot injection strategy with three injection pulses, results in higher performance compared to the other conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Realistic fuel spray modeling for gasoline direct injection engine applications

Fuel spray modeling plays a critical role during modern gasoline direct injection (GDI) engine development due to fuel injection’s dominant impact on engine performance and emissions as well as the complex physical processes involved. In engineering three-dimensional (3D) computational fluid dynamics (CFD) simulations, the liquid-phase fuel atomization, evaporation, and mixing are usually modeled with the discrete droplet model (DDM) adopting a Lagrangian approach for multiphase CFD simulations. To this end, general practices heavily depend on the reduced order characterization of the injector nozzle flow. However, such simplified injector modeling may lead to insufficient representations of the complex spray dynamics. To tackle this problem, this study proposes a novel workflow to numerically evaluate GDI sub-cooled and flash-boiling sprays under engine-relevant conditions using a side-mounted GDI injector together with real gasoline fuel properties. The workflow introduces a one-way coupling (OWC) method leveraging high-fidelity nozzle flow simulations to provide realistic boundary conditions to the Lagrangian injector model. The proposed workflow was first verified in a constant volume chamber (CVC) environment and then implemented in a practical GDI engine setup to study spray morphology, fuel-air mixing, and wall-wetting propensity. In addition, detailed comparison was performed between the OWC method and the conventional rate of injection (ROI) routine. In conclusion, quantitative analysis of spray characteristics was conducted to highlight possible source of discrepancies of the conventional ROI method.

33 ADVANCED PROPULSION SYSTEMS↗

Development of prechamber enabled mixing-controlled combustion strategy for ultra-low methane emissions from lean burn natural gas engines

This numerical study explores the optimization of Prechamber Enabled Mixing-Controlled Combustion (PC-MCC) using natural gas in heavy-duty engines, aiming to enhance combustion efficiency to minimize methane slip and NOx emissions. The approach involves a prechamber ignition system, distinct from conventional spark ignition (SI) systems, to initiate combustion of direct injected natural gas. By leveraging the robust ignition characteristics of the prechamber, the PC-MCC method demonstrates significant potential in achieving efficient combustion akin to diesel engines but with lower greenhouse gas emissions. The research evaluates the effects of various geometric and operational parameters on the combustion process and emissions, including prechamber volume, nozzle diameter, direct injector (DI) geometry, and engine operating strategies. Computational Fluid Dynamics (CFD) simulations are utilized, focusing on a heavy-duty, single-cylinder engine modeled after the Caterpillar C9.3B engine. Key findings indicate that a prechamber volume of 3 cc, coupled with a nozzle diameter of 2.75 mm for two prechamber holes, strikes an optimal balance between combustion efficiency and emissions reduction. This configuration ensures robust combustion across a range of operating conditions while maintaining methane slip within targeted limits. Further investigation into DI geometry shows the significance of the injector umbrella angle and nozzle diameter in shaping the fuel-air mixing and combustion dynamics. An umbrella angle of 130° and a nozzle diameter of 300 microns are identified as optimal, promoting rapid and efficient combustion with minimized methane and NOx emissions. The study also investigates the impact of injection timing and pressure, highlighting their roles in controlling combustion timing and influencing emissions levels. Advanced injection timing is found to be crucial in achieving the desired low methane slip, whereas retarded injection timing assists to reduce NOx emissions while having a slight increase in methane emissions. Operating strategies incorporating various levels of Exhaust Gas Recirculation (EGR) are assessed for their effectiveness in further reducing emissions. The research demonstrates that a judicious combination of internal hot EGR and careful calibration of DI pressure and SOI timing can achieve significant reductions in NOx emissions while keeping methane slip under control. Specifically, an internal EGR level of 15%–25%, combined with DI pressures of 200–300 bar and injection timings at or after top dead center, is recommended. These findings contribute valuable insights into the development of advanced combustion techniques for natural gas engines, offering a viable pathway to reduce methane slip without compromising engine efficiency or performance. The PC-MCC system presents a promising solution for the future of heavy-duty natural gas engine technology to reduce methane emissions.

Nsaif, Osama↗

ECAR-5067 Computational Evaluation on Effect of Edge-rounding in Circular to Annular Flow Transitions within a Hexagonal Duct

In this ECAR, the computational fluid dynamics (CFD) simulation of the duct with a cross-section varying from circle to annulus was performed to evaluate the effect of edge-rounding of the internal edges. The edge of circular channel and the edge of inner annular channel were rounded with the radius of curvature ranged from 0 mm to 20 mm. The CFD results show that the pressure loss of the duct can be reduced by increasing the radius of the rounded edge. Case-A results showed that the pressure drop can be significantly reduced by the edge-rounding, e.g., the pressure drop was reduced approximately 56% by the radius of curvature of 5.0mm, and reduced 70% by the radius of curvature of 20.0 mm although its effectiveness would be attenuated as the radius of curvature of edge increases. Results from Case-B showed the impact of rounding the inlet edge was practically negligible compared to the outlet edge. This ECAR could provide a guideline to determine the optimum inlet module design of the VTR fuel rod bundle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

Computational and Experimental Validation of Fractal-Fin, Dimpled Solar Heat Collector

A 3 foot x 3 foot x 3 foot aluminum solar collector was manufactured using computer numerical control. The interior of the device included six triangular dimpled fins for enhanced heat transfer. The interior vertical wall on the south side was also dimpled. The solar collector working fluid was based on water, and the collector consisted solely of passive heat transfer mechanisms (no moving parts), making it ideal for off-the-grid and rural applications. Two types of heat transfer experiments were conducted. One experiment had external flat heaters attached on the top and the front side, while the other four sides were insulated. Except for the bottom surface, the second experiment had all its exterior surfaces sprayed with black solar paint to collect as much solar heat as possible. Temperature data as a function of time was collected using 14 thermocouples spread strategically throughout the solar collector. In addition, computational fluid dynamics (CFD) simulations were conducted using the dynamic Smagorinsky large eddy simulation turbulence model. The first simulation considered that both the top and front surfaces were exposed to a fixed temperature of 313.7 K (105 °F), while the remaining four surfaces were insulated. For the second simulation, all conditions were the same, except that the temperature for both heated surfaces was raised to 350 K (170.3 °F). The two temperatures are expected to bound the solar collector operational temperature during the late- Spring, Summer, and early-Fall months. The solar collector design, experimental data, CFD output, and a discussion of five manufacturing approaches and costs are documented in this report.

14 SOLAR ENERGY↗

Isolated Building Wake Experiment At Texas Tech University’s Wind Engineering Research Field Lab

Texas Tech University’s (TTU’s) Wind Engineering Research Field Lab (WERFL) building is an idealized rectangular building on the scale of a typical suburban house. It is surrounded almost entirely by unobstructed planes and is built on a turn table. WERFL is ideal for providing measurements of an idealized building under real-world conditions including atmospheric stability and variable relative wind angles. The intent of this data set is for verification and validation of computational fluid dynamics model simulations of flow around buildings. The primary focus of this dataset features 24 3D sonic anemometers (20 downwind and 4 upwind) and 10 2D sonic anemometers (9 downwind and 1 upwind) located in the immediate vicinity of the WERFL building. It also includes a variety of instruments intended to measure the ambient meteorological parameters and the undisturbed wind profile.

17 WIND ENERGY↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗

Nanosecond Repetitively Pulsed (NRP) Plasmas: Relationship Between Induced Flow and Plasma Characteristics at Atmospheric Pressure (Final Technical Report)

The local flow fields induced by plasma discharges at atmospheric pressure can play a critical role in aerodynamic flow and combustion control and have significant implications for plasma-based technologies in medicine and environmental engineering. However, the coupling between the plasma characteristics, the geometry and the induced flow field is not well understood. The primary goal of this work is to determine the relationship between the plasma characteristics and the induced flow field for nanosecond pulsed discharges at atmospheric pressure. A comprehensive experimental investigation of plasmas produced by nanosecond high-voltage pulses in a pin-to-pin electrode configuration was conducted, employing several measurement techniques including microwave and laser Rayleigh scattering, optical emission spectroscopy, and high-speed imaging. The flow field induced by the nanosecond plasma was measured and characterized using measurements of the velocity (particle image velocimetry) and density (background oriented schlieren) with unprecedented spatiotemporal resolution. The experimental measurements were complemented by development of a one-dimensional model of the plasma discharge and a high-fidelity computational fluid dynamics (CFD) simulation of the subsequent plasma-induced flow field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Analysis and Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) simulations for both 300 g/s and 400 g/s are performed on the NMR target to analyze the helium flow through the NMR system. The pressure drop, the mass flow rate through each of the disc and window channels and the force applied on the first disc are some of the quantities estimated using CFD. These results will be combined with Monte Carlo N-Particle (MCNP) estimates of heat flux into the system from the electron beam to perform conjugate heat transfer analysis (CHT). The experiments presented in this report focus on the effect of the flow induced vibrations from helium flowing through the coolant gaps between the discs. There is concern that the flow induced vibrations may lead to excessive mass loss of the enriched Mo-100 discs, and the goal would be to mitigate the mass loss. This work presents benchtop tests of flow through a subset of the target stack which involves high speed imaging and displacement measurements used to estimate disc vibration, as well as mass loss.

42 ENGINEERING↗

Experimental and Theoretical Evaluation of Feed Flow Collar Design for Shell Fed Hollow Fiber Membrane Modules

An experimental and theoretical study of module collar design is presented here. Hollow fiber membranes are prepared by dip coating a poly(vinylidene) (PVDF) support with a polydimethylsiloxane (PDMS) gutter layer and a Pebax 2533 selective layer. Fiber bundles with a well-defined fiber packing are prepared using a 3D printed module. A parallel fiber bundle consisting of 4-9 uniformly spaced fibers is created with printed tabs that align the fibers and create a tubesheet. The tabs are sealed within a printed case that possesses a series of external ports for gas introduction and removal. Uniquely, both port location and the use of a collar to assist fluid distribution in the shell can be varied for the same fiber bundle. Experimental measurements are compared to computational fluid dynamics (CFD) simulations. The experimental module design allows high-fidelity representation of the fiber bundle and module case in the simulations. Comparisons between experiment and simulation are in good agreement over a broad range of experimental conditions. The detrimental effect of having ports located too close, leading to stagnation regions, is captured as well as the beneficial effects of using a collar for shell-side fluid distribution around the fiber bundle. Such results help validate the use of CFD to develop high-performance module designs.

Tran, Thien↗

Performance Testing of a Moving-Bed Gasifier Using Coal, Biomass, and Waste Plastic Blends with Washed and Unwashed Legacy Coals and Other Waste Fuels to Generate White Hydrogen

The objective of this effort, primarily funded by the United States Department of Energy (DOE), and led by the Electric Power Research Institute, Inc. (EPRI), with support by Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), has been to qualify coal, biomass, and plastic waste blends based on performance testing of selected fuel pellet compositions in a pilot-scale updraft moving-bed (UDMB) gasifier. The testing provided relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are the focus. The gasifier used for testing is HMI’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips (biomass). However, mixtures of these fuels with plastic wastes have not been prepared and gasified together. The three feedstocks were densified and pelletized by California Pellet Mill (CPM) to meet the feedstock size required by Sotacarbo’s 30mm ID UDMB gasifier, under contract to HMI. The technical tasks and results from this two-year research project included: (1) Feed Procurement and Preparation: Nine different tri-fuel pellets were prepared from varying compositions of fresh mined PRB coal, corn stover biomass, and car fluff waste plastics. Tri-fuel pellets were produced by CPM and shipped to Sotacarbo’s test facility in Carbonia, Sardinia, Italy. (2) Test Plan Development: A test plan was created to define the test runs to be performed. The test plan detailed the different UDMB gasification tests to be performed in Sotacarbo’s 12-inch ID pilot scale gasifier, the process monitoring instrumentation used, and the extractive samples recovered for analysis of the total gasification process mass and energy balance. (3) Gasifier Testing: Nine different gasification runs were performed in the pilot-scale gasifier at Sotacarbo using nine different fuel feedstock compositions generated from varying mixtures of PRB coal, biomass, and plastic wastes. The testing generated performance data on gasification reaction efficiency and performance, yielding relevant data for models used to scale up the gasifier design. This task also included work to refurbish and reassemble the pilot gasifier at Sotacarbo and perform a baseline 100% PRB coal run. (4) Data Analysis and Reporting: Review of the data, determination of figures of merit, and interpretation of the results are reported in the project’s final report, published in March 2024. The results show that all tri-fuel pellets gasified well and maintained structural integrity throughout the gasification process. The syngas generated can be shifted to hydrogen by using commercial syngas shifting technologies. (5) High Fidelity computational fluid dynamics (CFD) Simulation: The National Energy Technology Laboratory (NETL) team performed CFD simulations of the UDMB gasifier for two of the tri-fuel pellets gasified in Sotacarbo’s pilot scale gasifier. The kinetic mechanisms for the pyrolysis of each constituent, PRB coal, corn stover biomass, and waste plastics are based on thermogravimetric analysis performed by Sotacarbo. The gasification model was validated by comparing the predicted syngas composition at the exit of the gasifier with the measured syngas composition. In addition, the reactor’s measured internal temperature profile agreed well with the predicted internal reactor temperature profile. These results validate that the model can be used to predict the performance of the updraft moving bed gasifier for different feedstocks and operating conditions. This paper summarizes the results of the completed work in which the pelletizing procedure was validated to ensure the viability of the tri-fuel pellets for the gasification runs performed at Sotacarbo’s 30 mm UDMB gasifier. The gasification performance data from this series of nine runs will enable modeling of a full-scale HMI industrial scale gasifier supporting both combined heat and power, and Hydrogen production from coal (both fresh mined and legacy) combined with various biomass and waste plastics. Additionally, plans and progress on a follow-up project, being executed by the same project team, will be presented. In this project, a total of twenty (20) different feedstocks are being prepared from varying compositions of biomass (both woody biomass and corn stover) with a mixture of legacy coal waste, plastic waste, and refuse-derived fuel (RDF). The testing will provide information on gasification reaction efficiency/performance, yielding relevant data for models used to scale up the gasifier design to 50 megawatt electric (MWe) (equivalent hydrogen production). Tests will also be performed on a bench-scale fluidized-bed gasifier for comparison purposes. The results of this testing will be used to specify the range of feedstock blends that can be successfully gasified as well as quantify gasifier outputs based on specific blends.

08 HYDROGEN↗

Investigating the Effects of Chemical Mechanism on Soot Formation Under High-Pressure Fuel Pyrolysis

We performed Computational Fluid Dynamics (CFD) simulations using a Reynolds-Averaged Navier-Stokes (RANS) turbulence model of high-pressure spray pyrolysis with a detailed chemical kinetic mechanism encompassing pyrolysis of n-dodecane and formation of polycyclic aromatic hydrocarbons. We compare the results using the detailed mechanism and those found using several different reduced chemical mechanisms to experiments carried out in an optically accessible, high-pressure, constant-volume combustion chamber. Three different soot models implemented in the CONVERGE CFD software are used: an empirical soot model, a method of moments, and a discrete sectional method. There is a large variation in the prediction of the soot between different combinations of chemical mechanisms and soot model. Furthermore, the amount of soot produced from all models is substantially less than experimental measurements. All of this indicates that there is still substantial work that needs to be done to arrive at simulations that can be relied on to accurately predict soot formation.

02 PETROLEUM↗

Outflow Boundary Conditions for Turbine-Integrated Rotating Detonation Combustors

This study examines outflow boundary conditions (BCs) in computational fluid dynamics (CFD) simulations of a transition duct with and without guide vanes that converts supersonic flow exiting a rotating detonation combustor (RDC) to subsonic flow to drive a turbine. Since the flow exiting the transition duct has swirling shock waves with significant spatial and temporal variations in pressure, temperature, and Mach number, imposing proper BCs poses a challenge. To ensure all swirling shock waves exit the transition duct without creating non-physical reflected waves at its outlet, this study examined three outflow BCs: (1) the average pressure imposed at the duct’s outlet, (2) a nonreflecting BC (NRBC) with a specified average pressure imposed at the duct’s outlet, (3) the average pressure imposed at the outlet of an extension duct made up of a buffer layer and a sponge layer. This study is based on the three-dimensional, unsteady density-weighted-ensemble-averaged continuity, Navier–Stokes, and energy equations for a thermally perfect gas closed by the realizable k–ε model and “enhanced” wall functions. The results obtained show that imposing an average pressure at the transition duct’s outlet produces spurious waves that degrade the physical meaningfulness of the solution. When the NRBC was applied, swirling shock waves exited the duct’s outlet without creating spurious waves. However, its usage requires the gas to be thermally, as well as calorically, perfect, which this study shows could be a concern. By imposing the average pressure at the outlet of an extension duct, the gas does not need to be calorically perfect. The results obtained show the effects of the sponge layer’s length and coarsening ratio on damping nonuniformities in non-physical reflected waves to ensure the flow exiting the transition duct’s outlet can do so as if there are no boundaries present and has the desired average pressure—even though the BC is applied at the extension duct’s outlet.

gas turbines↗

Optimization of Window Positions for Wind-Driven Natural Ventilation Performance

This paper optimizes opening positions on building facades to maximize the natural ventilation’s potential for ventilation and cooling purposes. The paper demonstrates how to apply computational fluid dynamics (CFD) simulation results to architectural design processes, and how the CFD-driven decisions impact ventilation and cooling: (1) background: A CFD helps predict the natural ventilation’s potential, the integration of CFD results into design decision-making has not been actively practiced; (2) methods: Pressure data on building facades were obtained from CFD simulations and mapped into the 3D modeling environment, which were then used to identify optimal positions of two openings of a zone. The effect of the selected opening positions was validated with building energy simulations; (3) results: The cross-comparison study of different window positions based on different geographical locations quantified the impact on natural ventilation effectiveness; and (4) conclusions: The optimized window position was shown to be effective, and some optimal solutions contradicted the typical cross-ventilation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurements and Prediction of Ash Deposition in a Cyclone-Fired Boiler Operating under Variable Load Conditions

Measurements of ash deposition rates were made between the secondary superheater and reheater sections of a 450 MW cyclone-fired lignite boiler as the operational load varied from 33 to 100%. Significant reductions in deposition rates with a decrease in operational load were observed. To uncover the causative mechanisms behind these observations, operational data from the power plant were used to carry out computational fluid dynamic (CFD) simulations of the boiler. After ascertaining that the gas temperatures and velocities at various sections within the boiler were being represented adequately, decoupled simulations of the ash deposition process on the deposit probe were carried out using a finely resolved boundary layer mesh. Fly ash particle size distribution (PSD) and its concentration for the decoupled calculations were determined from stand-alone cyclone barrel simulations. The ash partitioning (mass %) between the fly ash and slag was found to be ~50:50, which was in line with previous field observations, and it did not vary significantly across different cyclone loads. The predicted PSD of the deposit ash was concentrated in the size range 10–30 microns, which was in agreement with cross-sectional images of the deposit obtained from the measurements. At lower loads, sharp variations in the deposition rates were predicted in the gas temperature range 950–1150 K. The particle kinetic energy—particle viscosity-based capture methodology utilized in this study in conjunction with appropriate ash compositions, ash viscosity models and gas temperature estimates can help estimate slagging propensities at different loads reasonably well in these systems.

Krishnamoorthy, Gautham (ORCID:0000000255205092)↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Investigation of Flux Spreading in a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on increasing the operating temperatures to accommodate high efficiency power cycles and thermochemical processes. Inert solid particles as heat transfer media enable solar receivers to operate above 700 degrees Celsius resulting in increased system thermal efficiency compared to the conventional molten salt based CSP system. An open-cavity falling-particle solar receiver that can efficiently heat particles by direct heating from concentrated solar radiation faces challenges with large particle losses from wind and unable to support thermochemical reactions. A light-trapping, planar cavity reiver (LTPCR) where particles are indirectly heated can significantly minimize the particle losses during the operation, support thermochemical reactions, and offer scalability potential. The LTPCR features an array of vertical planar receiver/absorber panels arranged within a cavity configuration. Concentrated solar radiation from heliostats is focused onto the receiver walls, where heat is indirectly transferred to solid particles flowing inside the receiver channels. Heat transfer occurs through direct contact between the receiver panel walls and particles, and can be enhanced by fluidizing particles with air. This fluidization increases particle-wall contact and extends particle residence time, maximizing heat transfer efficiency. The unique vertical planar receiver structure originated from a near-blackbody tubular light absorber, effectively distributing the incoming solar beam spread across the panel walls and trapping light. This flux spreading effect, driven by cosine projection, converts high incident solar flux into a lower, more uniform heat flux on the panel walls. This redistribution enhances heat transfer efficiency between particle-wall or reaction gases-wall, while preventing localized overheating of the receiver panel. Indirect planar cavity solar receivers completely separate solid particles from the ambient environment that can greatly reduce the thermal losses in heated particles resulting in high efficiency at high temperatures above 700 degrees Celsius. This design ensures no particle losses to the environment during the operation while open-cavity designs can experience significant particle losses from wind. An experimental investigation was conducted to observe flux spreading on the receiver panel wall. A lab-scale prototype planar receiver, fabricated using Haynes 230 alloy, was tested under direct concentrated solar radiation using the high-flux solar furnace (HFSF) facility at NREL. The experiment was performed under normal peak radiative heat fluxes ranging from 800 to 1900 kW/m2. A temperature distribution on the panel wall was measured using a thermal imaging camera (FLIR A 6600). To prevent overheating at the receiver front tip, prism-shaped heat shields (Zircar UNIFROM C1) were placed in front of the receiver, and their influence on flux spreading was also studied. Absorbed flux distribution on the panel wall was modeled using SolTrace. The total solar power and flux distributions delivered from HFSF were determined based on the heliostat mirror optical properties, direct normal irradiance (DNI) on the on-sun testing days, peak flux measurement during the on-sun testing, and shutter/attenuator settings Due to the large incident angles of the solar beam on the panel wall, the angular optical properties of Haynes 230 alloy and Zircar heat shields were incorporated into the model. This flux distribution model was then integrated into a computational fluid dynamics (CFD) simulation to predict the receiver panel wall temperature, which was compared with the experimental measurements. Both prediction and measurements identified a temperature hotspot at the backside of the panel, indicating that the incident solar beam can fully reach to the rear of the receiver. The heat shields positioned at the front of the receiver effectively reduced the excessive temperature rise at the receiver front tip. Overall, the temperature was well distributed over the panel wall, with a minor hotspot at the back of the receiver. The model slightly overpredicted the temperature, possibly due to discrepancies in optical properties of the panel and an underprediction of thermal loss in the receiver. The advancement of the particle LTPCR offers a viable alternative to open-cavity receivers by addressing particle loss issues. Additionally, it presents a pathway for enabling solar thermochemical processes, extending CSP technology beyond power generation to fuel and chemical production.

14 SOLAR ENERGY↗