Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFLECTOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Application of the Haar Wavelet to the Analysis of Plasma and Atmospheric Fluctuations

The parameters of turbulence measured by means of a Doppler reflectometer at the plasma periphery in an L-2M stellarator and in atmospheric vortices (typhoons and tornadoes) are investigated using the wavelet methods with involvement of the Haar function. The periods of time taken for the transition (a bound of parameters) to occur in the L-2M stellarator plasma and in atmospheric processes are estimated. It is shown that high-and low-frequency oscillations of certain parameters, in particular, pressure, that occur in atmospheric vortices decay or increase at different moments of time, whereas the density fluctuation amplitudes that occur in plasma at different frequencies vary in a synchronous manner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toroidal inhomogeneity of plasma density fluctuations during ECR plasma heating in the L-2M stellarator

Correlation between short-wavelength (k{sub ⊥} ≈ 20–30 cm{sup –1}) and long-wavelength (k{sub ⊥} ≈ 1–2 cm{sup –1}) plasma density fluctuations in two poloidal cross sections of the stellarator chamber separated by 1/14 or 5/14 of the torus perimeter was studied using collective scattering of radiation of two 75-GHz gyrotrons and radiation of a 37-GHz Doppler reflectometer at an ECR heating power density of 1.6–3.2 MW/m{sup 3}. It is found that excitation of turbulent fluctuations is bursty in character and that fluctuations excited in different L-2M cross sections are uncorrelated. It is shown that the energy of turbulent fluctuations is modulated by a low frequency of 5–20 kHz. An idea is put forward that anomalous transport is toroidally inhomogeneous.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast-ion-driven Alfvén eigenmodes during ICRF-heated high β p plasmas on EAST

Fast-ion-driven Alfvén eigenmodes (AEs) are observed during ICRF-heated high-β p plasmas on EAST. Multiple high frequency modes are observed for shot 112670 at f TAE1 ~ 145 kHz, δB/B ~ 4 × 10 –4 and f TAE2 ~ 175 kHz, δB/B ~ 1.2 × 10 –5 measured by high-frequency Mirnov coils, at B 0 ~ 2.45 T, I p ~ 350kA, n e ramp-up from 3.5 × 10 19 to 4 × 10 19 m −3 at P ECRH ~ 2 MW, PLHW ~ 2 MW, and P ICRH ~ 2.1 MW. Here, 37 MHz ICRF minority hydrogen heating scheme, located at plasma core, creates fast ion population which drives TAEs unstable from TORIC + SFFPQL. In the experiment, it is observed that the evolution of mode frequency depends on electron density, following the theoretical TAE frequency characteristic $f_{{{\text{th}}}} = V_{{\text{a}}} /(4\pi qR) \propto \sqrt {n_{{\text{e}}} }$. As the electron density increases, the amplitude of the AE mode progressively diminishes. Higher plasma density shortens the fast-ion slowing-down time, reduces the heating efficiency of minority hydrogen, weakens the high-energy tail, and consequently decreases the fast-ion beta. Based on the diagnostic results from the microwave reflectometer and electron cyclotron emission (ECE) diagnostics, the TAE is located within the plasma core, consistent with the narrower core region of the TAE gap observed in the continuous spectrum.

Pan, C. Y. [Chinese Academy of Sciences, Hefei (Ch↗

QuickNXS

Data reduction software for the Oak Ridge National Laboratory Spallation Neutron Source's Magnetism Reflectometer beam line 4A, used to extract reflectivity, off-specular and GISANS scattering from raw data in NeXus file format. The package consists of a Python library for the extraction and a Qt4 based graphical user interface to work with the data.

Glavic, ArturGregor↗

Fabrication and characterization of chalcogenide glass for hollow Bragg fibers

Low- and high-refractive-index chalcogenide glasses are studied for their potential use in the fabrication of one-dimensional hollow Bragg fibers. The low-index glasses are based on the GeSe-glass systems with indices varying from 2.0 to 2.5, while the high-index glasses are formed from the AgAsSe glasses with indices ranging from 2.8 to 3.8. High-purity elemental starting materials are distilled and the surface oxides removed prior to mixing in a rocking furnace. The refractive indices of the AgAsSe glasses, measured using a CO2 laser reflectometer, were near 3.10 for the compositions most compatible with the low-index Ge20Se80 glass (n=2.46). Spectral measurements show impurity absorption bands between 12 and 16 {mu}m. The loss at 10.6 {mu}m for the Ag25As40Se35 glass measured using CO2 laser calorimetry was 1.16x10{sup -3} cm{sup -1}.

36 MATERIALS SCIENCE↗

Estimation of phase shifts linked only to the coating for a dielectric mirror

The wavefront is an important characteristic for a dielectric mirror. Its measurement is usually performed with interferometers. We introduce a new method to evaluate only the coating wavefront distortion due to nonuniform thickness errors by using a reflectometer. This method uses some reflectance or transmittance maps at a wavenumber {sigma}{sub m} for which the reflectance or transmittance factor variation is high. These variations are translated into some central wavenumber {sigma}{sub c} variations, which enables the determination of a phase map from experimental treatment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for Mirror Neutron Oscillations

Data taken using the Magnetism Reflectometer at the Spallation Neutron Source, used in the proposal Titled: Search for Mirror Neutron Oscillations

ASTRONOMY AND ASTROPHYSICS↗

Search for Mirror Neutron Oscillations

Data taken using the Magnetism Reflectometer at the Spallation Neutron Source, used in the proposal Titled: Search for Mirror Neutron Oscillations

ASTRONOMY AND ASTROPHYSICS↗

Selected micrometeorological and soil data from the Manaus ZF2 K34 eddy covariance tower for the 2015/16 El Niño event

The K34 tower site (2.609 S, 60.209 W, 130 masl), located within the Tropical Silviculture Experimental Station (EEST, also known as ZF2) research station, in an area of undisturbed tropical forest (Araújo et al. 2002). It features long term measurements using micrometeorological, eddy covariance, and soil instrumentation, among others. This dataset covers January 2012 to December 2017, and includes air temperature (TA, ℃) and air relative humidity (RH, %), measured with thermohygrometers (HC2S3, Campbell Scientific, Logan, UT, USA) deployed above the canopy at the top of the tower (at 51.1 m height), and net radiation (NETRAD, W m-2) using an NR-LITE sensor (Kipp & Zonen, Delft, Netherlands), also at the top of the tower (at 35.0 m above the canopy). The soil moisture data included here is from a soil profile located approximately 12 m from the tower, and covers the period between February 2015 and September 2016. Volumetric soil water content (SWC, m3 m-3) measurements used Water Content Reflectometers (CS655 Campbell Scientific, Logan, UT, USA) at six depths: 10 cm, 20 cm, 30 cm, 40 cm, 60 cm, and 100 cm. Data are included in .csv files, and the text file ZF2-K34_Tower_headers.txt provides descriptions of data file headers.

54 ENVIRONMENTAL SCIENCES↗

New Fracture Diagnostic Tool for Unconventionals: High-Resolution Distributed Strain Sensing via Rayleigh Frequency Shift during Production in Hydraulic Fracture Test 2

Fiber Optic monitoring in unconventional reservoirs has proven to be an invaluable diagnostic tool for assessing both near-wellbore stimulation effectiveness and to help describe the far-field frac geometries created by hydraulic fracture stimulation. Unfortunately, gaining any detailed qualitative and quantitative understanding of the near-wellbore frac geometry or cluster/stage productivity during production via Fiber Optic (FO) has proven to be more difficult, particularly in wells producing liquids. A new FO diagnostic method, Distributed Strain Sensing based on Rayleigh Frequency Shift (DSS-RFS), first demonstrated for oil and gas applications in the Hydraulic Test Site 2 (HFTS2) provides new insights about the characteristics of near-wellbore-region (NWR) during production. DSS-RFS is different from other FO strain measurements because it relies on accurate measurement of frequency shifts of Rayleigh backscattered spectrum obtained by scanning the fiber with a coherent optical time-domain reflectometer with a range of laser frequencies using a tunable-wavelength laser system. Changes in strain are measured with an extremely high spatial resolution of 20 cm and with high signal-to-noise ratios over long distances. In HFTS2, strain changes for the entire wellbore have been measured twice during scheduled shut-in and reopening operations (February 2020 and September 2020). After removing temperature effects, consistent strain changes have been observed at the location of most perforation clusters. These are caused by near wellbore fracture aperture changes due to pressure increases during shut-in within the near-wellbore fracture network. The strain-change patterns from the DSS-RFS during shut-in correlate very well with the location of clusters and allow for the definition of extending intervals with positive strain signals at each cluster and slightly compressing intervals with negative strain signals between the clusters and in the non stimulated intervals. The locations of the measured positive strain peaks also show good correspondence to DAS acoustic intensity measurements acquired during the stimulation. The geometry and magnitude of the strain changes differ significantly between the two tested completion designs in the same well. During shut in and reopening each cluster exhibit its own strain-change / pressure path. In addition, the September 2020 dataset also revealed the existence of small but measurable strain changes as consequence of pressure decline during production. These strain changes also correlate well with the presence of producing clusters, but the strain-rate signals are opposite to that obtained during shut-in and reopening operations. Although Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S031R002/2477551/urtec-2021-5408-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5408 2 we are still in the early stages of exploring the potential of this novel FO technique, we believe that the highly detailed information contained in the measurement of strain changes using DSS-RFS during production can significantly improve our understanding of near-wellbore hydraulic fracture characteristics and the relationships between stimulation and production from unconventional oil and gas wells.

04 OIL SHALES AND TAR SANDS↗

SIMULATION STUDIES OF A PROTOTYPE STRIPLINE KICKER FOR THE APS-MBA UPGRADE

A prototype dual-blade stripline kicker for the APS multi-bend achromat (MBA) upgrade has been designed and developed. It was optimized with 3D CST Microwave Studio. The high voltage (HV) feedthrough and air-side connector were designed and optimized. Electromagnetic fields along the beam path, the deflecting angle, the high electric fields and their locations were calculated with 15kV differential pulse voltage applied to the kicker blades through the feedthroughs. Beam impedance and the power dissipation on different parts of the kicker and external loads were studied for a 48-bunch fill pattern. Our results show that the prototype kicker with its HV feedthroughs meets the specified requirements. The results of TDR (time-domain reflectometer) test, high voltage pulse test and beam test of the prototype kicker assembly agreed with the simulations.

APS MBA UPGRADE↗

User's Guide for REFoffSpec Version 1.5.4

This document is a user s guide for the IDL software REFoffSpec version 1.5.4 whose purpose is to aggregate for analysis NeXus data files from the magnetism and liquids reflectometer experiments at the Oak Ridge National Laboratory Spallation Neutron Source. The software is used to scale and align multiple data files that constitute a continuous set for an experimental run. The User s Guide for REFoffSepc explains step by step the process using a specific example run. Output screens are provided to orient the user at each step. The guide documents in detail changes made to the original REFoffSpec code during the period November 2009 and January 2011. At the time of the completion of this version of the code it was accessible from the sns_tools interface as a beta version.

Ward, Richard C.↗

AmeriFlux Measurement Component Instrument Handbook

An AMC system was installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s North Slope Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling PAR sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape. The soil VWC and temperature sensors used at NSA C1 are the Campbell Scientific CS650L and the sensors at NSA M1 use the Campbell Scientific CS655. The two sensors are nearly identical in function, and vendor specifications are based on the CS650 unless otherwise stated.

47 OTHER INSTRUMENTATION↗

AmeriFlux Measurement Component (AMC) Instrument Handbook

An AMC system was installed at the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility North Slope of Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling photosynthetically active radiation (PAR) sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape.

54 ENVIRONMENTAL SCIENCES↗

Distributed Fiber Optic Sensor for On-Line Monitoring of Coal Gasifier Refractory Health

This report summarizes technical progress on the program “Distributed Fiber Optic Sensor for On-Line Monitoring of Coal Gasifier Refractory Health,” funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The scope of work entails analyses of traveling grating generation technologies in an optical fiber, as well as the interrogation of the gratings to infer a distributed temperature along the fiber, for the purpose of developing a real-time refractory health condition monitoring technology for coal gasifiers. During the project period, which is from 2011-2015, three different sensing principles were studied, including four-wave mixing (FWM), coherent optical time-domain reflectometer (C-OTDR) and Brillouin optical time-domain analysis (BOTDA). By comparing the three methods, the BOTDA was selected for further development into a complete bench-top sensing system for the proposed high-temperature sensing application. Based on the input from Eastman Chemical, the industrial collaborator on this project, a cylindrical furnace was designed and constructed to simulate typical gasifier refractory temperature conditions in the laboratory, and verify the sensor’s capability to fully monitor refractory conditions on the back-side at temperatures up to 1000°C. In the later stages of the project, the sensing system was tested in the simulated environment for its sensing performance and high-temperature survivability. Through theoretical analyses and experimental research on the different factors affecting the sensor performance, a sensor field deployment strategy was proposed for possible future sensor field implementations.

01 COAL, LIGNITE, AND PEAT↗

Electron Temperature Fluctuation Measurements and Transport Model Validation at Alcator C-Mod

The tokamak is a type of toroidal device used to confine a fusion plasma using large magnetic fields. Tokamaks and stellarators the leading devices for confining plasmas for fusion, and the capability to predict performance in these magnetically confined plasmas is essential for developing a sustainable fusion energy source. The magnetic configuration of tokamaks and stellarators does not exist in Nature, yet, the fundamental processes governing transport in fusion plasmas are universal – turbulence and instabilities, driven by inhomogeneity and asymmetry in the plasma, conspire to transport heat and particles across magnetic field lines and can play critical roles in impurity confinement and generation of intrinsic rotation. Turbulence exists in all plasmas, and in neutral fluids as well. The study of turbulence is essential to developing a fundamental understanding of the nature of the fourth state of matter, plasmas. Experimental studies of turbulence in tokamaks date back to early scattering observations from the late 1970s. Since that time, great advances in turbulence diagnostics have been made, all of which have significantly enhanced our knowledge and understanding of turbulence in tokamaks. Through comparisons with advanced gyrokinetic theory and turbulent-transport models a great deal of evidence exists to implicate turbulent-driven transport as an important mechanism determining transport in all channels: heat, particle and momentum However, prediction and control of turbulent-driven transport remains elusive. Key to development of predictive transport models for magnetically confined fusion plasmas is validation of the nonlinear gyrokinetic transport model, which describes transport due to turbulence. Validation of gyrokinetic codes must include detailed and quantitative comparisons with measured turbulence characteristics, in addition to comparisons with inferred transport levels and equilibrium profiles. For this reason, advanced plasma diagnostics for studying core turbulence are needed in order to assess the accuracy of gyrokinetic models for turbulent-driven particle, heat and momentum transport. New core turbulence diagnostics at the world-class tokamaks Alcator C-Mod at MIT and ASDEX Upgrade at the Max Planck Institute for Plasma Physics have been designed, developed, and operated over the course of this project. These new instruments are capable of measuring electron temperature fluctuations and the phase angle between density and temperature fluctuations locally and quantitatively. These new data sets from Alcator C-Mod and ASDEX Upgrade are being used to fill key gaps in our understanding of turbulent transport in tokamaks. In particular, this project has results in new results on the topics of the Transport Shortfall, the role of ETG turbulence in tokamak plasmas, profile stiffness, the LOC/SOC transition, and intrinsic rotation reversals. These data are used in a rigorous process of “Transport model validation”, and this group is a world-leader on using turbulence models to design new hardware and new experiments at tokamaks. A correlation electron cyclotron emission (CECE) diagnostic is an instrument used to measure micro-scale fluctuations (mm-scale, compared to the machine size of meters) of electron temperature in magnetically confined fusion plasmas, such as those in tokamaks and stellarators. These micro-scale fluctuations are associated with drift-wave type turbulence, which leads to enhanced cooling and mixing of particles in fusion plasmas and limits achieving the required temperatures and densities for self-sustained fusion reactions. A CECE system can also be coupled with a reflectometer system that measured micro-scale density fluctuations, and from these simultaneous measurements, one can extract the phase between the density (n) and temperature (T) fluctuations, creating an nT phase diagnostic. Measurements of the fluctuations and the phase angle between them are extremely useful for testing and validating predictive models for the transport of heat and particles in fusion plasmas due to turbulence. Once validated, the models are used to predict performance in ITER and other burning plasmas, such as the MIT ARC design. Most recently, data from the newly developed, so-called “CECE diagnostic” [Cima 1995, White 2008] and “nT phase angle measurements” [Haese 1999, White 2010] ]will be combined with data from density fluctuation diagnostics at ASDEX Upgrade to support a long-term program of physics research in turbulence and transport that will allow for more stringent testing and validation of gyrokinetic turbulent-transport codes. This work directly impacts the development of predictive transport models in the U.S. FES program, such as TGLF, developed by General Atomics, which are used to predict performance in ITER and other burning plasma devices as part of advancing the development of fusion energy sciences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active Irradiation Testing of Temperature Sensing Capability of Clad Sapphire Optical Fibers with Type 2 Bragg Gratings using Optical Backscatter Reflectometry

This work investigated the temperature-sensing capabilities of Type II fiber Bragg gratings (FBGs) inscribed in sapphire optical fiber in the Ohio State University Research Reactor (OSURR). A Luna Innovations 4600 optical backscatter reflectometer (OBR) was used to interrogate FBGs in three sapphire optical fibers with an internal cladding that was developed by Ohio State. The sapphire fibers were fusion-spliced to silica lead fibers. In addition to the sapphire fibers, two silica fibers with the same Type II FBGs were included in the experiment as a reference. The fiber-based sensors were irradiated in the Central Irradiation Facility (CIF) of the OSURR for a total of 40 hours over 5 days at a reactor power of 450 kW, resulting in a total neutron fluence of approximately 2.5 × 10 18 n/cm 2 and a gamma dose of approximately 3.48 Grad. Two K-type thermocouples were included within the rig: one at the core centerline and the other 12 inches above the top of the core. The temperature was not actively controlled, but the thermocouples were used to provide a reference to which the fiber-based temperature measurements could be compared.

36 MATERIALS SCIENCE↗

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗