Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mask”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Maskless Fourier transform holography

Fourier transform holography is a lensless imaging technique that retrieves an object's exit-wave function with high fidelity. It has been used to study nanoscale phenomena and spatio-temporal dynamics in solids, with sensitivity to the phase component of electronic and magnetic textures. However, the method requires an invasive and labor-intensive nanopatterning of a holography mask directly onto the sample, which can alter the sample properties, forces a fixed field-of-view, and leads to a low signal-to-noise ratio at high resolution. In this work, we propose using wavefront-shaping diffractive optics to create a structured probe with full control of its phase at the sample plane, circumventing the need for a mask. We demonstrate in silico that the method can image nanostructures and magnetic textures and validate our approach with a visible light-based experiment. The method enables investigation of a plethora of phenomena at the nanoscale including magnetic and electronic phase coexistence in solids, with further uses in soft and biological matter research.

Keskinbora, Kahraman↗

Orthogonal spatial coding with stimulated parametric down-conversion

Orthogonal optical coding is widely used in classical multi-user communication networks. Using the phase conjugation property of stimulated parametric down-conversion, we extend the current time-domain orthogonal optical coding scheme to the spatial domain to encode and decode image information. In this process, the idler beam inherits the complex conjugate of the field information encoded in the seed beam. An encoding phase mask introduced onto the input seed beam blurs the image transferred to the idler. The original image is restored by passing the coded transferred image through a corrective phase mask placed in the momentum space of the idler beam. We expect that this scheme can also inspire new techniques in secure image transmission, aberration cancellation, and frequency conversion imaging.

Xu, Yang↗

National variability in Americans’ COVID-19 protective behaviors: Implications for vaccine roll-out

Protective behaviors such as mask wearing and physical distancing are critical to slow the spread of COVID-19, even in the context of vaccine scale-up. Understanding the variation in self-reported COVID-19 protective behaviors is critical to developing public health messaging. The purpose of the study is to provide nationally representative estimates of five self-reported COVID-19 protective behaviors and correlates of such behaviors. In this cross-sectional survey study of US adults, surveys were administered via internet and telephone. Adults were surveyed from April 30-May 4, 2020, a time of peaking COVID-19 incidence within the US. Participants were recruited from the probability-based AmeriSpeak® national panel. Brief surveys were completed by 994 adults, with 73.0% of respondents reported mask wearing, 82.7% reported physical distancing, 75.1% reported crowd avoidance, 89.8% reported increased hand-washing, and 7.7% reported having prior COVID-19 testing. Multivariate analysis (p critical value .05) indicates that women were more likely to report protective behaviors than men, as were those over age 60. Respondents who self-identified as having low incomes, histories of criminal justice involvement, and Republican Party affiliation, were less likely to report four protective behaviors, though Republicans and individuals with criminal justice histories were more likely to report having received COVID-19 testing. The majority of Americans engaged in COVID-19 protective behaviors, with low-income Americans, those with histories of criminal justice involvement, and self-identified Republicans less likely to engage in these preventive behaviors. Culturally competent public health messaging and interventions might focus on these latter groups to prevent future infections. These findings will remain highly relevant even with vaccines widely available, given the complementarities between vaccines and protective behaviors, as well as the many challenges in delivering vaccines.

60 APPLIED LIFE SCIENCES↗

Vegetation classification map and covariates associated with NEON AOP survey, East River, CO 2018

This package includes geospatial data layers developed to investigate how environmental gradients—specifically topography and near-surface soil properties—drive the spatial arrangement of dominant plant communities in mountainous watersheds. The geospatial products, which support the analysis of these ecological relationships, are derived from airborne hyperspectral and LiDAR datasets acquired by the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP), in conjunction with an extensive ground field campaign conducted in summer 2018. This work is part of the DOE Watershed Function Science Focus Area (SFA) and features geospatial datasets developed based on observations and ground data collected at East River, Colorado, in collaboration with the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP) survey in June 2018. Classification Map: - Classification Map (PNG, GeoTIFF): Derived from hyperspectral and LiDAR airborne data using a machine learning approach. - Class Code Mapper (CSV): Associates pixel values with corresponding vegetation/non-vegetation classes. - Classification Reference Data (CSV): Reference data used in the machine learning procedure. LiDAR-Derived Products: - Topographical Metrics (GeoTIFFs): Elevation, slope, curvature, TWI, TPI, solar insolation, and canopy height model (CHM), smoothed with a 5x5 pixel window. Vegetation Indices: - GeoTIFFs of NDVI, NDNI, NDWI: Vegetation indices derived from hyperspectral data. Urban Masks: - Urban Mask (GeoTIFF): Applied to the mapping to convert bare soil classes to urban classes. Software Compatibility: GeoTIFFs: Can be visualized with GIS software or libraries that support GeoTIFF images. CSV Files: Can be opened with any software that handles comma-separated values. The FLMD file provides details and links to the source datasets used to derive the products. The manuscript (in the Method session) provides details on how each product was derived. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Update on 2026-03-25: Since the original dataset publication date of 02/28/2020, this package has a new classification map derived by an improved methodology. This update also includes additional ground data that improved the representation of some of the communities. See the methods for further details on what has changed between versions.

2018 NEON and 2025 CHESS Campaigns↗

Denoising Seismic Waveforms Using a Wavelet-Transform-Based Machine-Learning Method

Seismic waveform data recorded at stations can be thought of as a superposition of the signal from a source of interest and noise from other sources. Frequency‐based filtering methods for waveform denoising do not result in desired outcomes when the targeted signal and noise occupy similar frequency bands. Recently, denoising techniques based on deep‐learning convolutional neural networks (CNNs), in which a recorded waveform is decomposed into signal and noise components, have led to improved results. These CNN methods, which use short‐time Fourier transform representations of the time series, provide signal and noise masks for the input waveform. These masks are used to create denoised signal and designaled noise waveforms, respectively. However, advancements in the field of image denoising have shown the benefits of incorporating discrete wavelet transforms (DWTs) into CNN architectures to create multilevel wavelet CNN (MWCNN) models. The MWCNN model preserves the details of the input due to the good time–frequency localization of the DWT. In this report we use a data set of over 382,000 constructed seismograms recorded by the University of Utah Seismograph Stations network to compare the performance of CNN and MWCNN‐based denoising models. Evaluation of both models on constructed test data shows that the MWCNN model outperforms the CNN model in the ability to recover the ground‐truth signal component in terms of both waveform similarity and preservation of amplitude information. Model evaluation of real‐world data shows that both the CNN and MWCNN models outperform standard band‐pass filtering (BPF; average improvement in signal‐to‐noise ratio of 9.6 and 19.7 dB, respectively, with respect to BPF). Evaluation of continuous data suggests the MWCNN denoiser can improve both signal detection capabilities and phase arrival time estimates.

58 GEOSCIENCES↗

Ka-Band ARM Zenith Radar Corrections (KAZRCOR, KAZRCFRCOR) Value-Added Products

The KAZRCOR Value -added Product (VAP) performs several corrections to the ingested KAZR moments and also creates a significant detection mask for each radar mode. The VAP computes gaseous attenuation as a function of time and radial distance from the radar antenna, based on ambient meteorological observations, and corrects observed reflectivities for that effect. KAZRCOR also dealiases mean Doppler velocities to correct velocities whose magnitudes exceed the radar’s Nyquist velocity. Input KAZR data fields are passed through into the KAZRCOR output files, in their native time and range coordinates. Complementary corrected reflectivity and velocity fields are provided, along with a mask of significant detections and a number of data quality flags. This report covers the KAZRCOR VAP as applied to the original KAZR radars and the upgraded KAZR2 radars. Currently there are two separate code bases for the different radar versions, but once KAZR and KAZR2 data formats are harmonized, only a single code base will be required.

54 ENVIRONMENTAL SCIENCES↗

Stereo Cameras for Clouds (STEREOCAM) Instrument Handbook

The three pairs of stereo camera setups aim to provide synchronized and stereo calibrated time series of images that can be used for 3D cloud mask reconstruction. Each camera pair is positioned at approximately 120 degrees from the other pair, with a 17o-19o pitch angle from the ground, and at 5-6 km distance from the U.S. Department of Energy (DOE) Central Facility at the Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) observatory to cover the region from northeast, northwest, and southern views. Images from both cameras of the same stereo setup can be paired together to obtain 3D reconstruction by triangulation. 3D reconstructions from the ring of three stereo pairs can be combined together to generate a 3D mask from surrounding views. This handbook delivers all stereo reconstruction parameters of the cameras necessary to make 3D reconstructions from the stereo camera images.

47 OTHER INSTRUMENTATION↗

Domestic Supply Chain of Medical Consumables Needed During COVID-19 Pandemic

This report is an assessment of the availability, demand, and production capability of medical consumables needed to combat the COVID-19 pandemic. We focus here on the ability of the supply chain to increase production to meet demand during peak pandemic conditions. In addition, we report on domestic production efforts and supply chain issues, as well as the propensity of other countries to limit export of needed medical supplies to the United States. In brief, the domestic supply chain and production capability vary greatly depending on the consumable. Some consumables, such as N95 masks or face shields, can likely be nearly fully supplied by domestic production, while other consumables, such as gloves or surgical masks, have little domestic production and thus will depend on imports to meet demand. The assessment pulls primarily from published news sources and company press releases. As such, the demand and production numbers are not precisely known, and some degree of uncertainty exists in them. The total production capability is also often difficult to ascertain from these reports especially as other industries have begun to supplement existing supply chains. In addition, local conditions (including company financial decisions, local public health issues, and political aspects) can vary throughout the pandemic which will affect future production. The report also pulls from estimates of demand and domestic production of some consumables compiled by the White House COVID-19 Supply Chain Taskforce (SCTF) presented by Rear Admiral John Polowczyk before a June 9, 2020 hearing of the Senate Homeland Security and Governmental Affairs Committee. These numbers, where applicable, are likely to be more accurate than those found in public news sources since they are more directly tied to private companies’ actual orders and actual production estimates, as opposed to publicly released estimates. Finally, we note that other issues with the supply chain, including the production of raw materials, increase demand due to industries that have not previously used PPE now using it, and increased domestic production from non-traditional suppliers, make complete picture of a rapidly changing supply chain difficult to obtain. This report attempts to produce an accurate image of the supply and estimated demand, as understood by the authors who are not experts in the medical supply chain.

42 ENGINEERING↗

Ka-Band ARM Zenith Radar Corrections (KAZRCOR, KAZRCFRCOR) Value-Added Products

The Ka-Band Atmospheric Radiation Measurement (ARM) Zenith Radar Corrections (KAZRCOR) and KA-Band ARM Zenith Radar CF-Radial, Corrected (KAZRCFRCOR) value-added products (VAPs) perform several corrections to the ingested KAZR moments and also create a significant detection mask for each radar mode. The VAPs compute gaseous attenuation as a function of time and radial distance from the radar antenna, based on ambient meteorological observations, and correct observed reflectivities for that effect. Mean Doppler velocities are dealiased to correct velocities whose magnitudes exceed the radar’s Nyquist velocity. Input KAZR data fields are passed through to the KAZRCOR or KAZRCFRCOR output files, in their native time and range coordinates. Complementary corrected reflectivity and velocity fields are provided, along with a mask of significant detections and a number of data quality flags. This report covers the KAZRCOR VAP as applied to the original KAZR radars and the upgraded KAZR2 radars. Originally, prior to late 2019, there were two separate code bases for the different radar versions. Following the harmonization of KAZR and KAZR2 data formats in 2019, only a single code base is required. The new combined KAZR and KAZR2 code base is called the KAZRCFRCOR VAP. The ‘cfr portion of the VAP name refers to the Radial Climate and Forecasting data format standards that are used in these data sets. Throughout this report, references to ‘KAZRCOR’ should be taken to apply to the ‘KAZRCFRCOR’ VAP as well unless there is an explicit statement to the contrary.

54 ENVIRONMENTAL SCIENCES↗

Self-Disinfecting Polymeric Coatings

A novel derivative of a previously-published polymeric material has been synthesized and developed into an easily-sprayable coating. Surface characterization of coatings confirm correct elemental presence, and viral assays reveal quantitative elimination of MS2 bacteriophage and Phi6 bacteriophage, surrogates used for SARS-CoV-2, in as little as 5 minutes upon contact. Furthermore, an N95 mask was dip-coated in the polymer solution and analyzed through microscopy and filtration efficacy testing. Though coating was successful, electrostatic interactions between mask layers and polymer reduced filtration efficacy significantly. As such, we expect the current results of this work to be applicable on non-respiratory PPE and on solid substrates of commonly-touched surfaces for rapid self-decontamination.

59 BASIC BIOLOGICAL SCIENCES↗

Production-Ready CsPbBr3 Module Fabrication

The purpose of this SBIR was to work on evaluation, development, and testing of CsPbBr3 semiconductors for use in commercial gamma-ray detection. The overarching goal was to demonstrate the capability to fabricate functional detectors through resources available to H3D, Inc in pursuit of an alternative to CdZnTe for room-temperature semiconductor detectors. Throughout the project, CdZnTe crystals from Redlen were used as a control group to demonstrate whether the fabrication processes could produce reasonable results. The CdZnTe crystals were diced into roughly 6 mm x 6 mm x 4.5 mm pieces and electrodes were evaporated onto planar faces. In one case, pixels were patterned through a laser ablation method; in the other, a rudimentary pixel shadow-mask was fabricated, and the pixels were generated in the evaporation process. A 16 mm x 16 mm x 14 mm CsPbBr3 crystal was diced into four smaller crystals. These CsPbBr3 had electrodes applied in a similar way to the CdZnTe samples with a rudimentary mask used for pixels on the cathode. Tested CdZnTe pieces were found to generally function with reasonable, low-energy performance. CsPbBr3 crystals were found to be non-functional under forward bias with a large dark-current. A separate attempt, using reverse bias in a non-H3D, Inc test system, observed a dark current similar to previous observations, and some active pixels but no waveforms were observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling New Approaches to Low-Cost Dopant Patterning for Interdigitated Back Contact Crystalline Silicon Solar Cells: Cooperative Research and Development, CRADA Number CRD-17-00665 (Final Report)

NREL is sub to the Department of Energy (DOE) Photovoltaic Research & Development (PVRD) project, titled "New Approaches to Low-Cost Scalable Doping for Interdigitated Back Contact Crystalline Silicon Solar Cells", awarded to Colorado School of Mines. The goal of this project was to develop an industrially relevant dopant patterning technique that enable high performing, cost efficient Interdigitated Back Contact (IBC) solar cells based on n-Cz silicon wafer. Several possibilities were explored at the beginning of the project and the masked plasma deposition was deselected as the most promising and industrially relevant. This method was thoroughly explored ion the course of the project, its limitations revealed and mitigated. NREL successfully the masked deposition integrated into the cell's process flow and produced the cells, alongside with numerous process development steps and application of in-house advanced characterization techniques. The report describes these developments by the task and in detail.

14 SOLAR ENERGY↗

Time-Delay Cosmography: Spectroscopy of Galaxies in the Environment of the J1537 Lensed Quasar System

Due to their sufficient distances and prevalence, lensed quasars have been a key site for research in gravitational lensing. In particular, researchers are interested in constraining Hubble's constant by measuring time delays in the arrival times of multiply imaged quasars. However, a lens model will need to be created that accounts for not just the lensing galaxy, but also any perturbers nearby that could affect the light path. Here, the J1537-3010 lensed quasar environment is investigated, and redshifts of 62 targets have been identified using Gemini IRAF and RASCAL. The success rate is roughly 45% across all four masks, less than the expected 60%-70%. We expect that masking out a bad amplifier contributed to the lower redshift measurement rates, as well as potentially poor viewing conditions during observation. With these redshifts, flexion shifts can be measured to determine if the observed target should be included in the lens model. An accurate lens model is fundament al for constraining the measurements of the time-delays of the quasar images and, thereby, constraining measurements in Hubble’s constant.

Kharchilava, George V.↗

CSAPR2 Optimized Convective Cell Tracking Data during TRACER

One of the challenges in analyzing convective cell properties is to observe the quick evolution of individual convective cells. While the operational radar data provide a volumetric data set to analyze radar observables of convective precipitation clouds, previous studies also suggested the quick evolution of cell life cycle that might not be captured by conventional radar volume scan strategies that take ~5-7 minutes. Aiming at enhancing our understanding of the links between convective cloud kinematic and microphysical processes as well as life cycles, the Tracking Aerosol Convection Interactions ExpeRiment (TRACER; Jensen et al. 2019) was conducted at Houston, Texas, in 2022. The TRACER campaign deployed the 2nd generation C-band Scanning ARM Precipitation Radar (CSAPR2), which performed frequent updates of range height indicator (RHI) and sector plan position indicator (PPI) scans to track individual convective cells every < 2 minutes, guided by a new cell tracking framework, Multisensor Agile Adaptive Sampling (MAAS; Kollias et al. 2020). This allows for capturing fast-evolving radar observables. We provide the processed CSAPR2 cell tracking data in CfRadial format collected during the TRACER field campaign from June to September 2022. The data files include processed radar variables: noise-masked reflectivity and differential reflectivity corrected for rain attenuation and systematic biases, noise-masked dealiased radial velocity, specific differential phase, locations of target cells (latitude, longitude, radar range), and radar-echo classification. Figure 1 provides an example of a 3D image of CSAPR2 reflectivity from the lowest PPI scan and an RHI scan after data processing.

54 ENVIRONMENTAL SCIENCES↗

Digital Silicon Photomultiplier Chip Testing

Silicon Photomultipliers (SiPMs) are highly sensitive photodetectors. Traditional analog SiPMs require complex external readout electronics. Digital SiPMs (dSiPMs) include digital readout circuitry directly on-chip, offering superior timing resolution, reduced power consumption and compact size, pixel-level masking for active noise reduction. The primary objectives of this study are to, verify digital logic integrity of the shift registers used for controlling the pixel masking circuit, and determine the dark count rate of individual pixels as a function of bias voltage and clock frequency. I observe and explain behavior of the shift register and counting circuit.

Graham, Bennett [U. Chicago (main)]↗

High-Quality Dry Etching of LiNbO3 Assisted by Proton Substitution through H2-Plasma Surface Treatment

The exceptional material properties of Lithium Niobate (LiNbO3) make it an excellent material platform for a wide range of RF, MEMS, phononic and photonic applications; however, nano-micro scale device concepts require high fidelity processing of LN films. Here, we reported a highly optimized processing methodology that achieves a deep etch with nearly vertical and smooth sidewalls. We demonstrated that Ti/Al/Cr stack works perfectly as a hard mask material during long plasma dry etching, where periodically pausing the etching and chemical cleaning between cycles were leveraged to avoid thermal effects and byproduct redeposition. To improve mask quality on X- and Y-cut substrates, a H2-plasma treatment was implemented to relieve surface tension by modifying the top surface atoms. Structures with etch depths as deep as 3.4 µm were obtained in our process across a range of crystallographic orientations with a smooth sidewall and perfect verticality on several crystallographic facets.

36 MATERIALS SCIENCE↗

The TESS–Keck Survey. I. A Warm Sub-Saturn-mass Planet and a Caution about Stray Light in TESS Cameras

We report the detection of a Saturn-size exoplanet orbiting HD 332231 (TOI 1456) in light curves from the Transiting Exoplanet Survey Satellite (TESS). HD 332231—an F8 dwarf star with a V-band magnitude of 8.56—was observed by TESS in Sectors 14 and 15. We detect a single-transit event in the Sector 15 presearch data conditioning (PDC) light curve. We obtain spectroscopic follow-up observations of HD 332231 with the Automated Planet Finder, Keck I, and SONG telescopes. The orbital period we infer from radial velocity (RV) observations leads to the discovery of another transit in Sector 14 that was masked by PDC due to scattered light contamination. A joint analysis of the transit and RV data confirms the planetary nature of HD 332231 b, a Saturn-size (0.867{sub −0.025}{sup +0.027} R{sub J}), sub-Saturn-mass (0.244±0.021 M{sub J}) exoplanet on a 18.71 day circular orbit. The low surface gravity of HD 332231 b and the relatively low stellar flux it receives make it a compelling target for transmission spectroscopy. Also, the stellar obliquity is likely measurable via the Rossiter–McLaughlin effect, an exciting prospect given the 0.14 au orbital separation of HD 332231 b. The spectroscopic observations do not provide substantial evidence for any additional planets in the HD 332231 system, but continued RV monitoring is needed to further characterize this system. We also predict that the frequency and duration of masked data in the PDC light curves for TESS Sectors 14–16 could hide transits of some exoplanets with orbital periods between 10.5 and 17.5 days.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic Misalignment of Interstellar Dust Filaments

We present evidence for scale-independent misalignment of interstellar dust filaments and magnetic fields. We estimate the misalignment by comparing millimeter-wave dust-polarization measurements from Planck with filamentary structures identified in neutral-hydrogen (H I ) measurements from H I 4PI. We find that the misalignment angle displays a scale independence (harmonic coherence) for features larger than the H I 4PI beamwidth (16$\acute{.}$2). We additionally find a spatial coherence on angular scales of ${ \mathcal O }(1^\circ )$. We present several misalignment estimators formed from the auto- and cross-spectra of dust-polarization and H I -based maps, and we also introduce a map-space estimator. Applied to large regions of the high-Galactic-latitude sky, we find a global misalignment angle of ~2°, which is robust to a variety of masking choices. By dividing the sky into small regions, we show that the misalignment angle correlates with the parity-violating TB cross-spectrum measured in the Planck dust maps. The misalignment paradigm also predicts a dust EB signal, which is of relevance in the search for cosmic birefringence but as yet undetected; the measurements of EB are noisier than those of TB, and our correlations of EB with misalignment angle are found to be weaker and less robust to masking choices. We also introduce an H I -based dust-polarization template constructed from the Hessian matrix of the H I intensity, which is found to correlate more strongly than previous templates with Planck dust B modes.

79 ASTRONOMY AND ASTROPHYSICS↗