Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Extreme ultraviolet emission spectra of Gd and Tb ions

Theoretical extreme ultraviolet emission spectra of gadolinium and terbium ions calculated with the Cowan suite of codes and the flexible atomic code (FAC) relativistic code are presented. 4d-4f and 4p-4d transitions give rise to unresolved transition arrays in a range of ions. The effects of configuration interaction are investigated for transitions between singly excited configurations. Optimization of emission at 6.775 nm and 6.515 nm is achieved for Gd and Tb ions, respectively, by consideration of plasma effects. The resulting synthetic spectra are compared with experimental spectra recorded using the laser produced plasma technique.

74 ATOMIC AND MOLECULAR PHYSICS↗

Invited Article: Characterization of background sources in space-based time-of-flight mass spectrometers

For instruments that use time-of-flight techniques to measure space plasma, there are common sources of background signals that evidence themselves in the data. The background from these sources may increase the complexity of data analysis and reduce the signal-to-noise response of the instrument, thereby diminishing the science value or usefulness of the data. This paper reviews several sources of background commonly found in time-of-flight mass spectrometers and illustrates their effect in actual data using examples from ACE-SWICS and MESSENGER-FIPS. Sources include penetrating particles and radiation, UV photons, energy straggling and angular scattering, electron stimulated desorption of ions, ion-induced electron emission, accidental coincidence events, and noise signatures from instrument electronics. Data signatures of these sources are shown, as well as mitigation strategies and design considerations for future instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of Auger-type emission from diatomic molecular targets interacting with fast multicharged ions

Multiple electron emission in collisions between bare multiply charged ions and diatomic molecules is studied. The role played by Auger-type emission in cross sections for fixed number of ejected electrons is investigated. It is shown that this postcollisional reaction gives the main contribution to these cross sections at high enough impact velocities. This behavior is accentuated as the ionization degree increases.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lithium plasma emitter for collisionless magnetized plasma experiment

This paper presents a newly developed lithium plasma emitter, which can provide quiescent and low-temperature collisionless conditions for magnetized plasma experiments. This plasma emitter generates thermal emissions of lithium ions and electrons to produce a lithium plasma. Lithium type beta-eucryptite and lanthanum-hexaboride (LaB{sub 6}) powders were mixed and directly heated with a tungsten heater to synthesize ion and electron emissions. As a result, a plasma with a diameter of {approx}15 cm was obtained in a magnetic mirror configuration. The typical range of electron density was 10{sup 12}-10{sup 13} m{sup -3} and that of electron temperature was 0.1-0.8 eV with the emitter operation temperature of about 1500 K. The amplitude fluctuations for the plasma density were lower than 1%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Capture and Loss Processes in Forward Electron Emission in Fast Ion-atom Collisions

Forward-going continuum electron emission has been investigated in 0.4-2 MeV/u O{sup 7+} and O{sup 8+}+He collisions. The one and two-electron processes of electron capture to the continuum (ECC), electron loss to the continuum (ELC), and transfer ionization (TI) have been separated by detecting cusp electrons in coincidence with the outgoing charge states of the projectile ions. The data are compared to earlier results of Zhu et al. for the O{sup 7+}+Ar collision system. The relative importance of the different contributions to forward electron emission and the role of the electron-electron interaction are discussed. The relationships of these results to recent studies of radiative-electron-capture-to-the continuum (RECC) are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Understanding the Degredation of Silicion Electrodes for Lithium Ion Batteries Using Acoustic Emission

Silicon is a promising anode material for lithium ion battery application due to its high specific capacity, low cost, and abundance. However, when silicon is lithiated at room temperature it can undergo a volume expansion in excess of 280% which leads to extensive fracturing. This is thought to be a primary cause of the rapid decay in cell capacity routinely observed. Acoustic emission (AE) was employed to monitor activity in composite silicon electrodes while cycling in lithium ion half-cells using a constant current-constant voltage procedure. The major source of AE was identified as the brittle fracture of silicon particles resulting from the alloying reaction that gives rise to LixSi phases. The largest number of emissions occurred on the first lithiation corresponding to surface fracture of the silicon particles, followed by distinct emission bursts on subsequent charge and discharge steps. Furthermore, a difference in the average parameters describing emission during charge and discharge steps was observed. Potential diagnostic and materials development applications of the presented AE techniques are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Biomolecular Emission by Swift Heavy Ion Bombardment

Secondary Ion Mass spectrometry (SIMS) has been generally used in the field of material sciences. In recent years, it has also been applied for molecular imaging of biological samples. Nevertheless, molecular ions derived from the large molecules (more than 1 kDa) were detected with very low sensitivity. Plasma desorption mass spectrometry (PDMS) is known as mass spectrometry for large organic molecule. In PDMS, fission fragments bombard samples and the impact induces molecular ionization by electronic excitation. Large organic molecules are detected by using swift heavy ions in SIMS. In this work, 6 MeV Cu{sup 4+} we irradiated angiotensin II, a class of peptides. The intact molecular ions generated by swift heavy ion irradiation were analyzed by time-of-flight (TOF) measurement. The yields are compared with some other probe ions, bismuth or flurane. Swift heavy ion bombardment ionized large organic molecules more effectively than other probes. Therefore, high energy ion can be applied in high resolution molecular imaging.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of High-Intensity Ion Beam Generation in the Diode with External Magnetic Insulation and Explosive Plasma Emission Source

The ion B{sub r}-diode in which plasma is generated under the action of a negative pre-pulse voltage is presented. Preliminary plasma formation allows the energy released in the diode during a positive voltage pulse to be increased. The high-energy ion beam parameters are investigated for the magnetic field induction changing from 0.8В{sub cr} to 1.7B{sub cr}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyroharmonic emissions induced by energetic ions in the equatorial plasmasphere

A theoretical investigation shows that MeV ions observed in the plasmasphere which have a power law distribution function possessing strong pitch angle anisotropy can give rise to emissions at frequencies near the harmonics of the ion gyrofrequencies observed in the same region. These emissions are sustained by the low-beta sub c plasma in the plasmasphere. It is found that only emissions with frequencies along the fast magnetosonic branch may occur and that these waves are essentially perpendicularly propagating. Growth is restricted to frequencies immediately below the ion gyroharmonics by the resonance condition and implies line widths of about 0.001 Omega sub alpha. Observations of ion gyroharmonic emissions with spacings of 1/16, 1/8, and 3/16 of the proton gyrofrequency may indicate the existence of energetic ion O(+), O(2+), and O(3+), respectively.

Curtis, S. A.↗

Proton emission from a laser ion source

At intensities of the order of 10{sup 10} W/cm{sup 2}, ns pulsed lasers can be employed to ablate solid bulk targets in order to produce high emission of ions at different charge state and kinetic energy. A special interest is devoted to the production of protons with controllable energy and current from a roto-translating target irradiated in repetition rate at 1-10 Hz by a Nd:Yag pulsed laser beam. Different hydrogenated targets based on polymers and hydrates were irradiated in high vacuum. Special nanostrucutres can be embedded in the polymers in order to modify the laser absorption properties and the amount of protons to be accelerated in the plasma. For example, carbon nanotubes may increase the laser absorption and the hydrogen absorption to generate high proton yields from the plasma. Metallic nanostrucutres may increase the electron density of the plasma and the kinetic energy of the accelerated protons. Ion collectors, ion energy analyzer, and mass spectrometers, used in time-of-flight configuration, were employed to characterize the ion beam properties. A comparison with traditional proton ion source is presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of LEED, Auger emission spectroscopy and field ion microscopy in microstructural studies

Surface research tools such as LEED, Auger emission spectroscopy analysis, and field ion microscopy are discussed. Examples of their use in studying adhesion, friction, wear, and lubrication presented. These tools have provided considerable insight into the basic nature of solid surface interactions. The transfer of metals from one surface to another at the atomic level has been observed and studied with each of these devices. The field ion microscope has been used to study polymer-metal interactions and Auger analysis to study the mechanism of polymer adhesion to metals. LEED and Auger analysis have identified surface segregation of alloying elements and indicated the influence of these elements in metallic adhesion. LEED and Auger analysis have assisted in adsorption studies in determining the structural arrangement and quantity of adsorbed species present in making an understanding of the influence of these species on adhesion possible. These devices are assisting in the furtherance of understanding of the fundamental mechanism involved in the adhesion, friction, wear, and lubrication processes.

Ferrante, J.↗