Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charge coupled devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Meteoroid Handbook for Aerospace Engineers and Managers

At the beginning of the Space Age, spacecraft designers and mission planners were very concerned about meteoroids. They envisioned vehicles being ripped to pieces by streams of fast-moving space rocks, a notion promoted by the science fiction novels and movies of the time. The reality is, of course, different—the meteoroid streams that produce meteor showers are not dense by laypeople’s standards, having spatial densities of just a handful of particles per cubic kilometer, even during meteor outbursts. The ever-present, diffuse, sporadic background, which produces observed meteor rates of only 5 to 8 meteors per hour, makes up 90% of the meteoroid risk to spacecraft that spend at least a year in low Earth orbit (LEO), whereas the visually spectacular but short-lived meteor showers make up the other 10%. Still, meteoroids do pose a significant risk to spacecraft. At Earth, they can travel 12 to 72 km/s. These high speeds cause even small meteoroids to carry enormous kinetic energy, making them capable of doing serious damage to spacecraft. For example, a 1-mm-diameter meteoroid moving at 25 km/s can inflict the same damage as a bullet fired from a 0.357 Magnum pistol. An exterior wire can be severed by a 0.1-mm (100 mm) particle, a spacesuit can be penetrated by a 0.5-mm meteoroid, and an unshielded pressure wall (like the cabin of the Space Shuttle) can be perforated by centimeter-sized particles. Along with mechanical damage, meteoroids can also cause other types of spacecraft anomalies. Meteoroids can transfer their momentum to the spacecraft, which can destroy or damage equipment such as shunt resistors and charge-coupled device (CCD) detectors with a clear view of space. Meteoroid impacts can also generate plasma. The impact vaporizes material, producing a crater and an expanding plasma, which can in turn provide a conductive path for any charge accumulated on the spacecraft. This effect is thought to be responsible for the demise of a satellite in one case: the OLYMPUS communications satellite was sent tumbling out of control during the 1993 Perseid outburst, and a Perseid meteoroid strike has been posited as a possible cause (McDonnell et al. 1993; Caswell et al. 1995). Other researchers have suggested that very fast meteoroids could produce a small electromagnetic pulse capable of disrupting spacecraft function (Close et al. 2010).

Moorhead, A.↗

A predictive model for space-based X-ray CCD degradation

The first generation of X-ray telescopes to use Charge-Coupled Devices (CCDs) is being launched this decade. With a read noise of a few electrons, CCDs provide Fano-limited spectral resolution across the soft X-ray band (0.1 - 10 keV). However, degradation of resolution due to charge transfer losses becomes noticeable as Charge Transfer Inefficiency (CTI) increases to 10(exp -5). In this paper, we present a model which calculates the effects of radiation damage in low Earth orbit in order to predict CCD lifetimes over which good charge transfer is maintained. The model presented here considers damage mechanisms within the CCD, environmental conditions in which the CCD operates, and experiment shielding. We find that the predicted CTI approaches 10(exp -5) after a one to two year mission for the flight instruments considered here.

Antunes, Alex↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

The DAMIC-M experiment: Status and first results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called “hidden sector.” A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision metering of microliter volumes of biological fluids in micro-gravity

Concepts were demonstrated and investigated for transferring accurately known and reproducible microliter volumes of biological fluids from sample container onto dry chemistry slides in microgravity environment. Specific liquid transfer tip designs were compared. Information was obtained for design of a liquid sample handling system to enable clinical chemical analysis in microgravity. Disposable pipet tips and pipet devices that were designed to transfer microliter volumes of biological fluid from a (test tube) sample container in 1-G environment were used during microgravity periods of parabolic trajectories of the KC-135 aircraft. The transfer process was recorded using charge coupled device camera and video cassette equipment. Metering behavior of water, a synthetic aqueous protein solution, and anticoagulated human blood was compared. Transfer of these liquids to 2 substrate materials representative of rapidly wettable and slowly wettable dry chemistry slide surface was compared.

Columbus, Richard L.↗

Pulsed laser synthesis of mesoporous metal chalcogenide thin films

Mesoporous films of the metal chalcogenide B-FeSe were grown on MgO substrates by KrF pulsed laser deposition (PLD) in an argon background. At 100 mTorr, gated intensified charge-coupled device imaging and ion probe measurements showed that the plasma plume responsible for crystal growth initially comprised three components, with distinct expansion velocities. Plume interactions with the substrate heater and ablation target gave rise to complex dynamics, including collisions between the charged leading edge—rebounding between the substrate and the target—and slower-moving species in the plume interior. Film growth was dominated by species with kinetic energies ≤0.5 eV/atom. X-ray reflectivity revealed that films grown in this environment—with a substrate temperature of 350 ° C, a laser fluence of 1.0 J cm −2 , and a 7.5 mm 2 spot area—formed a porous framework with 15% porosity. Atomic force microscopy showed surface features that suggest pore sizes below 100 nm. X-ray diffraction indicated that the porous films were epitaxial with respect to the substrate and likely grew by oriented-attachment of gas-phase molecular clusters or very small nanoparticles, in contrast to the conventional epitaxy of vacuum films from atomic constituents. The in-plane orientation of the mesoporous films was B-FeSe [100]||[110] MgO, attributed to the soft landing of pre-formed crystallites on the MgO substrates, where protruding Se rows of B-FeSe aligned with corrugations of the MgO surface. In conclusion, this work implies that growth of candidate electrocatalyst materials by PLD in inert gas background may allow mesoporous frameworks with a single crystallographic orientation that expose specific crystal facets for electrochemical reactions and active site engineering.

cluster epitaxy↗

Silicide Schottky Barrier For Back-Surface-Illuminated CCD

Quantum efficiency of back-surface-illuminated charge-coupled device (CCD) increased by coating back surface with thin layer of PtSi or IrSi on thin layer of SiO2. In its interaction with positively-doped bulk Si of CCD, silicide/oxide layer forms Schottky barrier that repels electrons, promoting accumulation of photogenerated charge carriers in front-side CCD potential wells. Physical principle responsible for improvement explained in "Metal Film Increases CCD Output" (NPO-16815).

Hecht, Michael H.↗

Proton radiation effects on multi-pinned-phased CCDs

Three Tektronix 1024 x 1024 multi-pinned-phased (MPP) charge coupled devices were irradiated with protons to obtain data on CCD performance degradation in a proton radiation environment. The devices were irradiated with a spectrum of energies up to 120 MeV, simulating the total radiation dose of a long-term space experiment. Basic parameters such as charge transfer efficiency, dark current, noise, and full well were measured before and after irradiation. A test was also performed to determine the effectiveness of various thicknesses of tantalum shielding in protecting the CCD from damage. Dark current increase and CTE degradation were the most noticeable effects of proton radiation. This paper will present the objectives, test data, and conclusions of the proton testing, and will identify future testing to be performed.

Murata-Seawalt, D.↗

Optical Tweezer Assembly and Calibration

An Optical Tweezer, as the name implies, is a useful tool for precision manipulation of micro and nano scale objects. Using the principle of electromagnetic radiation pressure, an optical tweezer employs a tightly focused laser beam to trap and position objects of various shapes and sizes. These devices can trap micrometer and nanometer sized objects. An exciting possibility for optical tweezers is its future potential to manipulate and assemble micro and nano sized sensors. A typical optical tweezer makes use of the following components: laser, mirrors, lenses, a high quality microscope, stage, Charge Coupled Device (CCD) camera, TV monitor and Position Sensitive Detectors (PSDs). The laser wavelength employed is typically in the visible or infrared spectrum. The laser beam is directed via mirrors and lenses into the microscope. It is then tightly focused by a high magnification, high numerical aperture microscope objective into the sample slide, which is mounted on a translating stage. The sample slide contains a sealed, small volume of fluid that the objects are suspended in. The most common objects trapped by optical tweezers are dielectric spheres. When trapped, a sphere will literally snap into and center itself in the laser beam. The PSD s are mounted in such a way to receive the backscatter after the beam has passed through the trap. PSD s used with the Differential Interference Contrast (DIC) technique provide highly precise data. Most optical tweezers employ lasers with power levels ranging from 10 to 100 miliwatts. Typical forces exerted on trapped objects are in the pico-newton range. When PSDs are employed, object movement can be resolved on a nanometer scale in a time range of milliseconds. Such accuracy, however, can only by utilized by calibrating the optical tweezer. Fortunately, an optical tweezer can be modeled accurately as a simple spring. This allows Hook s Law to be used. My goal this summer at NASA Glenn Research Center is the assembly and calibration of an optical tweezer setup in the Instrumentation and Controls Division (5520). I am utilizing a custom LabVIEW Virtual Instrument program for data collection and microscope stage control. Helping me in my assignment are the following people: Mentor Susan Wrbanek (5520), Dr. Baha Jassemnejad (UCO) and Technicians Ken Weiland (7650) and James Williams (7650). Without their help, my task would not be possible.

Collins, Timothy M.↗

CCD With Back-Side Illumination And Charge Steering

Proposed charge-coupled device (CCD) imaging array of photodetectors has features of back-side-illuminated CCD and interline-transfer CCD. Photoelectrons generated near back surface and swept by electric fields toward front into collecting potential wells, not directly opposite that location. By suitable timing of control signals, charges from multiple image frames stored in rapid succession. Useful in imaging rapid transient phenomena as chemically reacting flows, with interframe intervals of microseconds.

Fossum, Eric R.↗

Modeling of Proton-Induced CCD Degradation in the Chandra X-Ray Observatory

Modeling results are presented for proton-induced degradation of charge-coupled devices (CCDs) used in the Advanced CCD Imaging Spectrometer instrument on the Chandra X-Ray Observatory. A methodology is described that provides insights regarding degradation mechanism and on-orbit performance for front-illuminated and back-illuminated CCDs Proton-induced changes in charge transfer inefficiency are modeled. The observed amount of on-orbit degradation can be accounted for using a proton spectrum at the CCD location that is reduced in magnitude by a factor of approx. 1E5 compared to the spectrum incident on the spacecraft.

Lo, D. H.↗

Performance characteristics of STIS detectors

We report quantum efficiency measurements of back-illuminated, ion-implanted, laser-annealed charge coupled devices (CCD's) in the wavelength range 13-10,000 A. The equivalent quantum efficiency (EQE = effective photons detected per incident photon) ranges from a minimum of 5 percent as 1216 A to a maximum of 87 percent at 135 A. Using a simple relationship for the charge collection efficiency of the CCD pixels as a function of depth, we present a semi-empirical model with few parameters which reproduces our measurements with a fair degree of accuracy. The advantage of this model is that is can be used to predict CCD QE performance for shallow backside implanted devices without detailed solution of a system of differential equations, as in conventional approaches, and yields a simple analytic form for the charge collection efficiency which is adequate for detector calibration purposes. Making detailed assumptions about the dopant profile, we also solve the carrier density and continuity equations in order to relate our semi-empirical model parameters to surface and bulk device properties. The latter procedure helps to better establish device processing parameters for a given level of CCD QE performance.

Stern, Robert A.↗

Monolithic Active-Pixel Infrared Sensors

Monolithic arrays of active-pixel junction field-effect (JFET) devices made from InGaAs proposed for use as imaging sensors sensitive to light in visible and short-wavelength infrared parts of electromagnetic spectrum. Each pixel of such array comprises photodetector monolithically integrated with JFET output-amplifier circuit of source-follower type - structure similar to charge-coupled device (CCD). Sizes of instruments reduced because large cooling systems not needed.

Fossum, Eric R.↗

Thermal Design of the Cassini Narrow Angle Camera

The Narrow Angle Camera (NAC) is one of two cameras in the Imaging Science Subsystem (ISS) on the Cassini Spacecraft (S/C), the second camera is a Voyager-inherited Wide Angle Camera (WAC). Cassini is currently planned to be launched in October 1997 and will arrive at Saturn for a four year tour in June 2004. The Narrow Angle Optics are a Ritchey Chretien type Optics, has a focal length of 2000 mm, a relative aperture of f/10.5, a spectral range of 200 to 1100 nm, 24 filters, a pixel field of view of 6.0 microradian/pixel, and has a field of view of 3.5 x 3.5 degrees. The sensor is a Charged Couple Device (CCD), 1024 x 1024 pixels with a pixel size of 12 x 12 um, a full well greater than 50,000 e-, on chip processing of up to 800,000 e- pixel summation, a dark current of less than 0.1 e-/pixel/sec at operating temperature, and a charge transfer efficiency of 0.99999 at operating temperature...

Hoffman, Pamela↗

Aerodynamic Measurement Technology

Ohio State University developed a new spectrally filtered light-scattering apparatus based on a diode laser injected-locked titanium: sapphire laser and rubidium vapor filter at 780.2 nm. When the device was combined with a stimulated Brillouin scattering phase conjugate mirror, the realizable peak attenuation of elastic scattering interferences exceeded 105. The potential of the system was demonstrated by performing Thomson scattering measurements. Under USAF-NASA funding, West Virginia University developed a Doppler global velocimetry system using inexpensive 8-bit charged coupled device cameras and digitizers and a CW argon ion laser. It has demonstrated a precision of +/- 2.5 m/sec in a swirling jet flow. Low-noise silicon-micromachined microphones developed and incorporated in a novel two-tier, hybrid packaging scheme at the University of Florida used printed circuit board technology to realize a MEMS-based directional acoustic array. The array demonstrated excellent performance relative to conventional sensor technologies and provides scaling technologies that can reduce cost and increase speed and mobility.

Burner, Alpheus W.↗

Fabrication of large-area CCD detectors on high-purity, float-zone silicon

In this report on the fabrication of a 1024 x 1024 charge coupled device (CCD) imager to be used as a soft x-ray sensor onboard the Advanced X-ray Astronomical Facility (AXAF), the following conclusions were found: the dislocations that limited the performance of the high resistivity imager were characterized; the sources of stress were identified and the dislocations found were eliminated; and a charge transfer inefficiency (CTI) of 10(exp -6) and read noise as low as 1.3/e was demonstrated. This sensor must have low noise and a low CTI and must be radiation hardened to withstand any radiation damage from a space environment.

Gregory, J. A.↗

Deployable Wireless Camera Penetrators

A lightweight, low-power camera dart has been designed and tested for context imaging of sampling sites and ground surveys from an aerobot or an orbiting spacecraft in a microgravity environment. The camera penetrators also can be used to image any line-of-sight surface, such as cliff walls, that is difficult to access. Tethered cameras to inspect the surfaces of planetary bodies use both power and signal transmission lines to operate. A tether adds the possibility of inadvertently anchoring the aerobot, and requires some form of station-keeping capability of the aerobot if extended examination time is required. The new camera penetrators are deployed without a tether, weigh less than 30 grams, and are disposable. They are designed to drop from any altitude with the boost in transmitting power currently demonstrated at approximately 100-m line-of-sight. The penetrators also can be deployed to monitor lander or rover operations from a distance, and can be used for surface surveys or for context information gathering from a touch-and-go sampling site. Thanks to wireless operation, the complexity of the sampling or survey mechanisms may be reduced. The penetrators may be battery powered for short-duration missions, or have solar panels for longer or intermittent duration missions. The imaging device is embedded in the penetrator, which is dropped or projected at the surface of a study site at 90 to the surface. Mirrors can be used in the design to image the ground or the horizon. Some of the camera features were tested using commercial "nanny" or "spy" camera components with the charge-coupled device (CCD) looking at a direction parallel to the ground. Figure 1 shows components of one camera that weighs less than 8 g and occupies a volume of 11 cm3. This camera could transmit a standard television signal, including sound, up to 100 m. Figure 2 shows the CAD models of a version of the penetrator. A low-volume array of such penetrator cameras could be deployed from an aerobot or a spacecraft onto a comet or asteroid. A system of 20 of these penetrators could be designed and built in a 1- to 2-kg mass envelope. Possible future modifications of the camera penetrators, such as the addition of a chemical spray device, would allow the study of simple chemical reactions of reagents sprayed at the landing site and looking at the color changes. Zoom lenses also could be added for future use.

Badescu, Mircea↗

Gesture-Controlled Interfaces for Self-Service Machines

Gesture-controlled interfaces are software- driven systems that facilitate device control by translating visual hand and body signals into commands. Such interfaces could be especially attractive for controlling self-service machines (SSMs) for example, public information kiosks, ticket dispensers, gasoline pumps, and automated teller machines (see figure). A gesture-controlled interface would include a vision subsystem comprising one or more charge-coupled-device video cameras (at least two would be needed to acquire three-dimensional images of gestures). The output of the vision system would be processed by a pure software gesture-recognition subsystem. Then a translator subsystem would convert a sequence of recognized gestures into commands for the SSM to be controlled; these could include, for example, a command to display requested information, change control settings, or actuate a ticket- or cash-dispensing mechanism. Depending on the design and operational requirements of the SSM to be controlled, the gesture-controlled interface could be designed to respond to specific static gestures, dynamic gestures, or both. Static and dynamic gestures can include stationary or moving hand signals, arm poses or motions, and/or whole-body postures or motions. Static gestures would be recognized on the basis of their shapes; dynamic gestures would be recognized on the basis of both their shapes and their motions. Because dynamic gestures include temporal as well as spatial content, this gesture- controlled interface can extract more information from dynamic than it can from static gestures.

Cohen, Charles J.↗