Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Wavelength-Dependent Excitonic Properties of Covalent Organic Frameworks Explored by Theory and Experiments

Many aspects of the correlation between physical structure, light harvesting, and excitonic properties of covalent organic frameworks (COFs) remain unclear despite being key properties determining their photocatalytic function. One area of COF research that could bring clarity is through using both electronic structure theory and time-resolved spectroscopic analysis over a series of isomeric COFs. Here, we show structure-property relationships between four imine COFs built from a combination of ditopic and tritopic monomers using transient absorption spectroscopy together with time-dependent density functional theory. We find that monomer selection only moderately affects the charge transfer (CT) behavior of the COFs. Instead, we infer that imine chemistry profoundly impacts CT by acting as a CT mediator. Moreover, we discover two distinct valence bands arising from varying degrees of locally excited/CT mixing, which is responsible for energy dependent exciton dynamics. Finally, we use theory to hypothesize that interlayer interactions can modify excitonic properties that we correlate with tail states commonly observed, but rarely investigated in COFs. Furthermore, these results reveal that imine chemistry should be recognized as a very important factor to consider in the development of COF photocatalysts and the correlation of their structural environment with light harvesting and CT properties that should ultimately determine their photocatalytic function.

14 SOLAR ENERGY↗

Tunable Localized Charge Transfer Excitons in Nanoplatelet–2D Chalcogenide van der Waals Heterostructures

Observation of interlayer, charge transfer (CT) excitons in van der Waals heterostructures (vdWHs) based on 2D–2D systems has been well investigated. While conceptually interesting, these charge transfer excitons are highly delocalized and spatially localizing them requires twisting layers at very specific angles. This issue of localizing the CT excitons can be overcome via making nanoplate–2D material heterostructures (N2DHs) where one of the components is a spatially quantum confined medium. Here, we demonstrate the formation of CT excitons in a mixed dimensional system comprising MoSe 2 and WSe 2 monolayers and CdSe/CdS-based core/shell nanoplates (NPLs). Spectral signatures of CT excitons in our N2DHs were resolved locally at the 2D/single-NPL heterointerface using tip-enhanced photoluminescence (TEPL) at room temperature. By varying both the 2D material and the shell thickness of the NPLs and applying an out-of-plane electric field, the exciton resonance energy was tuned by up to 100 meV. Finally, our finding is a significant step toward the realization of highly tunable N2DH-based next-generation photonic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tunable electrochromic behavior of titanium-based MXenes

Two-dimensional transition metal carbides, nitrides and carbonitrides, popular by the name MXenes, are a promising class of materials as they exhibit intriguing optical, optoelectronic and electrochemical properties. Taking advantage of their metallic conductivity and hydrophilicity, titanium carbide MXenes (Ti 3 C 2 T x and others) are used to fabricate solution processable transparent conducting electrodes (TCEs) for the design of three-electrode electrochromic cells. However, the tunable electrochromic behavior of various titanium-based MXene compositions across the entire visible spectrum has not yet been demonstrated. Here, we investigate the intrinsic electrochromic properties of titanium-based MXenes, Ti 3 C 2 T x , Ti 3 CNT x , Ti 2 CT x , and Ti 1.6 Nb 0.4 CT x , where individual MXenes serve as a transparent conducting, electrochromic, and plasmonic material layer. Plasmonic extinction bands for Ti 3 C 2 T x , Ti 2 CT x and Ti 1.6 Nb 0.4 CT x are centered at 800, 550 and 480 nm, which are electrochemically tunable to 630, 470 and 410 nm, respectively, whereas Ti 3 CNT x shows a reversible change in transmittance in the wide visible range. Additionally, the switching rates of MXene electrodes with no additional transparent conductor electrodes are estimated and correlated with the respective electrical figure of merit values. This work demonstrates that MXene-based electrochromic cells are tunable in the entire visible spectrum and suggests the potential of the MXene family of materials in optoelectronic, plasmonic, and photonic applications, such as tunable visible optical filters and modulators, to name a few.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge transfer in mixed and segregated stacks of tetrathiafulvalene, tetrathianaphthalene and naphthalene diimide: a structural, spectroscopic and computational study

Tetrathiafulvalene (TTF) is a highly tunable electron donor that has been widely studied in charge transfer (CT) complexes, including Bechgaard salts which are superconductors at low temperatures. Its close relative, tetrathianaphthalene (TTN) has received considerably less attention than its TTF counterpart but is potentially a versatile electron donor. Three novel CT complexes containing mixed and segregated stack donor-acceptor (D–A) complexes of tetrathiafulvalene (TTF), tetrathianaphthalene (TTN) and naphthalene diimide (NDI) are reported. We demonstrate a facile mechanochemical synthesis of two salts, TTF–DPNI and TTN–DPNI (DPNI = N,N'-di-(4-pyridyl)-1,4,5,8-naphthalenetetracarboxydiimide), which is uncommon for these materials. Despite the detection of a very low partial charge transfer in the three salts using UV-Vis-NIR, Raman and EPR spectroscopies, we elucidated the properties of the TTN core with support from DFT calculations for the first time. Finally, we highlight the performance of TTN in a CT complex and demonstrate the importance of a combined approach to the characterisation of CT in organic D–A complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-dimensional electronic Stark spectroscopy of a photosynthetic dimer

Stark spectroscopy, which measures changes in the linear absorption of a sample in the presence of an external DC electric field, is a powerful experimental tool for probing the existence of charge-transfer (CT) states in photosynthetic systems. CT states often have small transition dipole moments, making them insensitive to other spectroscopic methods, but are particularly sensitive to Stark spectroscopy due to their large permanent dipole moment. In a previous study, we demonstrated a new experimental method, two- dimensional electronic Stark spectroscopy (2DESS), which combines two-dimensional electronic spectroscopy (2DES) and Stark spec- troscopy. In order to understand how the presence of CT states manifest in 2DESS, here, we perform computational modeling and calculations of 2DESS as well as 2DES and Stark spectra, studying a photosynthetic dimer inspired by the photosystem II reaction center. Here, we identify specific cases where qualitatively different sets of system parameters produce similar Stark and 2DES spectra but significantly different 2DESS spectra, showing the potential for 2DESS to aid in identifying CT states and their coupling to excitonic states.

14 SOLAR ENERGY↗

Photoinduced charge transfer in Zn(II) and Au(III)-ligated symmetric and asymmetric bacteriochlorin dyads: A computational study

The excited-state properties and photoinduced charge-transfer (CT) kinetics in a series of symmetrical and asymmetrical Zn- and Au-ligated meso–meso-connected bacteriochlorin (BChl) complexes are studied computationally. BChl derivatives, which are excellent near-IR absorbing chromophores, are found to play a central role in bacterial photosynthetic reaction centers but are rarely used in artificial solar energy harvesting systems. The optical properties of chemically linked BChl complexes can be tuned by varying the linking group and involving different ligated metal ions. We investigate charge transfer in BChl dyads that are either directly linked or through a phenylene ring (1,4- phenylene) and which are ligating Zn or Au ions. The directly linked dyads with a nearly perpendicular arrangement of the BChl units bear markedly different properties than phenylene linked dyads. In addition, we find that the dielectric dependence of the intramolecular CT rate is very strong in neutral Zn-ligated dyads, whereas cationic Au-ligated dyads show negligible dielectric dependence of the CT rate. Rate constants of the photo induced CT process are calculated at the semiclassical Marcus level and are compared to fully quantum mechanical Fermi’s golden rule based values. The rates are calculated using a screened range separated hybrid functional that offers a consistent framework for addressing environment polarization. We study solvated systems in two solvents of a low and a high scalar dielectric constant.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparative genomics approach identifies contact-dependent growth inhibition as a virulence determinant

Emerging evidence suggests the Pseudomonas aeruginosa accessory genome is enriched with uncharacterized virulence genes. Identification and characterization of such genes may reveal novel pathogenic mechanisms used by particularly virulent isolates. In this work, we utilized a mouse bacteremia model to quantify the virulence of 100 individual P. aeruginosa bloodstream isolates and performed whole-genome sequencing to identify accessory genomic elements correlated with increased bacterial virulence. From this work, we identified a specific contact-dependent growth inhibition (CDI) system enriched among highly virulent P. aeruginosa isolates. CDI systems contain a large exoprotein (CdiA) with a C-terminal toxin (CT) domain that can vary between different isolates within a species. Prior work has revealed that delivery of a CdiA-CT domain upon direct cell-to-cell contact can inhibit replication of a susceptible target bacterium. Aside from mediating interbacterial competition, we observed our virulence-associated CdiA-CT domain to promote toxicity against mammalian cells in culture and lethality during mouse bacteremia. Structural and functional studies revealed this CdiA-CT domain to have in vitro tRNase activity, and mutations that abrogated this tRNAse activity in vitro also attenuated virulence. Furthermore, CdiA contributed to virulence in mice even in the absence of contact-dependent signaling. Overall, our findings indicate that this P. aeruginosa CDI system functions as both an interbacterial inhibition system and a bacterial virulence factor against a mammalian host. These findings provide an impetus for continued studies into the complex role of CDI systems in P. aeruginosa pathogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Convolutional neural network based non-iterative reconstruction for accelerating neutron tomography *

Abstract Neutron computed tomography (NCT), a 3D non-destructive characterization technique, is carried out at nuclear reactor or spallation neutron source-based user facilities. Because neutrons are not severely attenuated by heavy elements and are sensitive to light elements like hydrogen, neutron radiography and computed tomography offer a complementary contrast to x-ray CT conducted at a synchrotron user facility. However, compared to synchrotron x-ray CT, the acquisition time for an NCT scan can be orders of magnitude higher due to lower source flux, low detector efficiency and the need to collect a large number of projection images for a high-quality reconstruction when using conventional algorithms. As a result of the long scan times for NCT, the number and type of experiments that can be conducted at a user facility is severely restricted. Recently, several deep convolutional neural network (DCNN) based algorithms have been introduced in the context of accelerating CT scans that can enable high quality reconstructions from sparse-view data. In this paper, we introduce DCNN algorithms to obtain high-quality reconstructions from sparse-view and low signal-to-noise ratio NCT data-sets thereby enabling accelerated scans. Our method is based on the supervised learning strategy of training a DCNN to map a low-quality reconstruction from sparse-view data to a higher quality reconstruction. Specifically, we evaluate the performance of two popular DCNN architectures—one based on using patches for training and the other on using the full images for training. We observe that both the DCNN architectures offer improvements in performance over classical multi-layer perceptron as well as conventional CT reconstruction algorithms. Our results illustrate that the DCNN can be a powerful tool to obtain high-quality NCT reconstructions from sparse-view data thereby enabling accelerated NCT scans for increasing user-facility throughput or enabling high-resolution time-resolved NCT scans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Band-mixing effects in one-dimensional charge transfer insulators

The low-energy properties of transition metal oxides (TMOs) are governed by the electrons occupying strongly correlated $d$-orbitals that are hybridized with surrounding ligand oxygen $p$ orbitals to varying degrees. Their physics is thus established by a complex interplay between the transition-metal (TM)-ligand hopping $t$, charge transfer energy $\Delta_\mathrm{CT}$, and on-site TM Hubbard repulsion $U$. Here, we study the spectral properties of a one-dimensional (1D) analog of such a $pd$ system, with alternating TM $d$ and ligand anion $p$ orbitals situated along a chain. Using the density matrix renormalization group method, we study the model's single-particle spectral function, x-ray absorption spectrum, and dynamical spin structure factor as a function of $\Delta_\mathrm{CT}$ and $U$. In particular, we present results spanning from the Mott insulating ($\Delta_\mathrm{CT} > U$) to negative charge transfer regime $\Delta_\mathrm{CT} < 0$ to gain a better understanding of the ground and momentum-resolved excited state properties of these different regimes. Our results can guide new studies on TMOs that seek to situate them within the Mott-Hubbard/charge transfer insulator classification scheme.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Near-room-temperature ferromagnetic ordering in the pressure-induced collapsed-tetragonal phase in SrC⁢o 2 ⁢P 2

We present high-pressure electrical transport, magnetization, and single-crystal x-ray diffraction data on SrC⁢o 2 ⁢P 2 single crystals, revealing a transition from the uncollapsed tetragonal (ucT) to the collapsed tetragonal (cT) phase >∼10 GPa. This structural transition is accompanied by ferromagnetic (FM) ordering with a Curie temperature up to 260 K. First-principles-based density functional theory calculations show that there is a first-order transition between ucT and cT phases, with an onset ∼10 GPa as well as the appearance of FM ordering in the cT phase. Above ∼30 GPa, the experimental signatures of the magnetic ordering vanish in a first-order-like manner, consistent with the theoretical calculation results, indicating that SrC⁢o 2 ⁢P 2 is another example of the avoidance of quantum criticality in FM intermetallic compounds with almost room-temperature critical temperature. SrC⁢o 2 ⁢P 2 provides clear evidence that the structural, electronic, and magnetic properties associated with the cT transition are strongly entangled and are not only qualitatively captured by our first-principles-based calculations but are quantitatively reproduced as well.

density functional theory↗

Distributed Stochastic Optimization of a Neural Representation Network for Time-Space Tomography Reconstruction

4D time-space reconstruction of dynamic events or deforming objects using X-ray computed tomography (CT) is an important inverse problem in non-destructive evaluation. Conventional back-projection based reconstruction methods assume that the object remains static for the duration of several tens or hundreds of X-ray projection measurement images (reconstruction of consecutive limited-angle CT scans). However, this is an unrealistic assumption for many in-situ experiments that causes spurious artifacts and inaccurate morphological reconstructions of the object. To solve this problem, we propose to perform a 4D time-space reconstruction using a distributed implicit neural representation (DINR) network that is trained using a novel distributed stochastic training algorithm. Our DINR network learns to reconstruct the object at its output by iterative optimization of its network parameters such that the measured projection images best match the output of the CT forward measurement model. Here, we use a forward measurement model that is a function of the DINR outputs at a sparsely sampled set of continuous valued 4D object coordinates. Unlike previous neural representation architectures that forward and back propagate through dense voxel grids that sample the object's entire time-space coordinates, we only propagate through the DINR at a small subset of object coordinates in each iteration resulting in an order-of-magnitude reduction in memory and compute for training. DINR leverages distributed computation across several compute nodes and GPUs to produce high-fidelity 4D time-space reconstructions. We use both simulated parallel-beam and experimental cone-beam X-ray CT datasets to demonstrate the superior performance of our approach.

36 MATERIALS SCIENCE↗

Seeing through the nucleus: A review of color transparency phenomena

In this work, we review the current status of the phenomenon of color transparency (CT), a fundamental consequence of the description of hadrons from quantum chromodynamics. CT refers to the vanishing of final (and/or initial) state interactions with the nuclear medium for exclusive process at sufficiently high enough momentum transfers. We discuss the current experimental observations relating to CT and their theoretical implications for other high energy processes. Future CT experiments and facilities are also described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MRI-Based Radiotherapy Planning to Reduce Rectal Dose in Excess of Tolerance

Background and Purpose. Chronic rectal toxicity significantly decreases the quality of life for men who receive radiotherapy for prostate cancer. The most significant predictor of rectal toxicity is rectal dose-volume exceeding tolerance. To minimize the volume of rectum in the high dose field, it is essential to accurately define the prostate-rectum interface. This can be challenging to do by computed tomography (CT) imaging alone. The current study was undertaken to formally demonstrate in a clinical trial setting that image-guided intensity-modulated radiation therapy (IG-IMRT) planning using magnetic resonance imaging (MRI) can reduce the volume of rectum exceeding 70 Gy, a validated metric that predicts the risk of late rectal toxicity. Materials and Methods. This prospective single-arm study enrolled 15 men treated with IG-IMRT for localized prostate cancer. All participants received a dedicated 3 Tesla MRI examination of the prostate in addition to a pelvic CT examination for treatment planning. Two volumetric modulated arc therapy (VMAT) plans with a prescription dose of 79.2 Gy were designed using identical constraints based on CT- and MRI-defined consensus volumes. The volume of rectum exposed to 70 Gy or more was compared using the Wilcoxon paired signed rank test. Results. For CT-based treatment plans, the median volume of rectum receiving 70 Gy or more was 9.3 cubic centimeters (cc) (IQR 7.0 to 10.2) compared with 4.9 cc (IQR 4.1 to 7.8) for MRI-based plans. This resulted in a median volume reduction of 2.1 cc (IQR 0.5 to 5.3, P < .001). Conclusions. Using MRI to plan prostate IG-IMRT to a dose of 79.2 Gy reduces the volume of rectum receiving radiation dose in excess of tolerance (70 Gy or more) and should be considered in men who are at high risk for late rectal toxicity and are not good candidates for other rectal sparing techniques such as hydrogel spacer. This trial is registered with NCT02470910.

Schmidt, Daniel R.↗

Wettability Alteration with Weak Acid-Assisted Surfactant Flood

Oil-wetness and heterogeneity are two key reasons for low oil recovery by waterflooding in carbonate reservoirs. Surfactants have been effective in altering the oil-wet matrix to a more water-wet condition and initiating spontaneous imbibition. Because it takes time for the surfactant to alter wettability, oil recovery from the tight matrix is slow and sometimes not economically feasible. Acids have the potential of dissolving minerals, which may alter wettability. In this study, the enhanced oil recovery (EOR) performance of an acid-assisted surfactant solution, a novel technique, was evaluated for low-temperature applications. A set of acids and their acetates were tested. Bulk rock-acid reaction, wettability alteration (WA) tests, and spontaneous imbibition measurements were conducted at reservoir temperature (35°C) to identify effective candidates. Coreflood tests were then performed to evaluate the selected acid-surfactant formulations. Before and after a coreflood test, the core was scanned using micro-computed tomography (CT) to investigate pore structure alteration. Bulk reaction measurements showed that weak acids, especially acetic acid (AA), have the desired low reaction rates at 35°C. WA tests showed that AA can remove the crude oil off the rock surface and alter wettability through mineral dissolution. The surfactant can reduce contact angles from 160° to 58°; adding acid into the surfactant can further reduce it to 52°. Spontaneous imbibition experiments showed the synergy between the acid and the surfactant; the AA-surfactant solution had the highest oil recovery (62.6%) among acid-surfactant formulations. The acid improves the WA efficiency by the surfactant through surface mineral dissolution and lower ζ-potential. The imbibition transports the acid-surfactant solutions into the matrix, which minimizes face dissolution. Coreflood tests show that the AA-surfactant flood can increase the oil recovery rate and recover about 8% more oil compared to the surfactant flood. Micro-CT showed that a few mineral particles were transported along the core and partially plugged pore throats, which reduced permeability and diverted flow leading to improved oil recovery. Here, the transport of the acid in reservoirs and the potential plugging issues have to be carefully evaluated in future studies.

58 GEOSCIENCES↗

Surface Roughness Calculations of Additively Manufactured Cylinders via X-Ray Computed Tomography

X-ray Computed Tomography (X-ray CT) is an analytical technique used in materials science to non–destructively characterize features in variety of materials like polymers, metals, composites, and explosives. It also has the capability of imaging additively manufactured, machined and assembled parts and processes. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations as a result of different stimuli, and assess accuracy of material production. This study will focus on parts manufactured via metal additive manufacturing (AM). Although, AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties. The analysis of 3D printed objects has a strength in analysis in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e. foams) due to stochastic structures. For this study, the print accuracy of several 3D printed cylinders will be assessed via X-ray CT to determine optimal printing parameters for parts with less defects and stronger mechanical properties. This will be accomplished by having the original STL file serve as the baseline surface to compute difference in the CT rendering to calculate surface roughness for each cylinders.

36 MATERIALS SCIENCE↗

Improving Coal-Fired Plant Performance Through Integrated Predictive and Condition-Based Monitoring Tools

The project demonstrated the ability to improve boiler performance and reliability through the integrated use of condition-based monitoring (CBM) and predictions of the impacts of coal quality on boiler operations at a full-scale coal-fired power plant. The advanced tool developed actively monitors and manages coal quality and overall boiler conditions that maximizes availability and maintains generating capacity while reducing cost. The tool is used to forecast and alert plant operators and engineers about poor boiler conditions which may occur as a result of incoming coal and/or current power plant operating conditions. The Combustion System Performance Indices (CSPI) and CoalTracker (CT) programs predicts fireside performance of the plant including slagging, fouling, erosion, slag flow, strength development (sintering/densification), and slag layer thickness based on the composition of delivered coal. CT program is tailored for each plant and is used to track the coal from the point of delivery to the burner. The most successful application of the CSPI-CT has been at plants where the coal composition is determined through the use of a full stream elemental analyzers based on prompt gamma neutron analysis (PGNAA). The CSPI-CT program information is used by coal procurement, coal mining and plant operations personnel to select and blend coal properties for the best plant performance.

01 COAL, LIGNITE, AND PEAT↗