Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Method and system for a gas tube-based current source high voltage direct current transmission system

A high-voltage direct-current (HVDC) transmission system includes an alternating current (AC) electrical source and a power converter channel that includes an AC-DC converter electrically coupled to the electrical source and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and the DC-AC inverter each include a plurality of legs that includes at least one switching device. The power converter channel further includes a commutating circuit communicatively coupled to one or more switching devices. The commutating circuit is configured to "switch on" one of the switching devices during a first portion of a cycle of the H-bridge switching circuits and "switch off" the switching device during a second portion of the cycle of the first and second H-bridge switching circuits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Reinforcement Scheduling of Energy Storage Systems for Real-time Voltage Regulation in Unbalanced LV Networks with High PV Penetration

The ever-growing higher penetration of distributed energy resources (DERs) in low-voltage (LV) distribution systems brings both opportunities and challenges to voltage support and regulation. This paper proposes a deep reinforcement learning (DRL)-based scheduling scheme of energy storage systems (ESSs) to mitigate system voltage deviations in unbalanced LV distribution networks. The ESS-based voltage regulation problem is formulated as a multi-stage quadratic stochastic program, with the objective of minimizing the expected total daily voltage regulation cost while satisfying operational constraints. While existing voltage regulation methods are mostly focused on onetime- step control, this paper explores a day-horizon systemwide voltage regulation problem. In other words, the size of action and state spaces are extremely high-dimensional and need to be delicately handled. Furthermore, in order to overcome the difficulty of modeling uncertainties and develop a realtime solution, a learn-to-schedule feedback control framework is proposed by adapting the problem to a model-free DRL setting. The proposed algorithm is tested on a customized 6-bus system and a modified IEEE 34-bus system. Simulation results validate the effectiveness and near-optimality of voltage regulation by ESS in comparison with a deterministic quadratic program solution.

Wang, Shengyi↗

Electrochemical Degradation Modes in Bifacial Silicon Photovoltaic Modules

Motivated by the rapidly rising deployment of bifacial monocrystalline-silicon photovoltaics (PV), we investigate the durability of various PV module packaging configurations with transparent coverings on both the front and rear sides of the module. We use a series of bifacial passivated emitter and rear cell (p-PERC) mini-modules with systematically varying outer cover materials (glass/glass, G/G, or glass/transparent backsheet, G/TB) and encapsulant chemistries (poly [ethylene-co-vinyl acetate], EVA; or polyolefin, POE). We study degradation modes over 1,000 hours of combined damp heat (DH) exposure and high system voltages that can cause potential-induced degradation (PID) under positive, zero, or negative 1,000 V cell-to-frame bias. We analyze the degradation modes using a combination of current-voltage measurements, impedance spectroscopy, external quantum efficiency, and spatially resolved luminescence and thermal imaging. Our results highlight various types of degradation including shunting, enhanced recombination, and series resistance increases, and we use spatially resolved characterization to separately identify the localized effects. We show that multiple PID and moisture-ingress degradation modes severely affect EVA-containing modules, with previously reported PID processes under negative-bias DH and a unique observation of rear-side surface recombination in G/EVA/G modules under positive-bias DH. We observe significantly less degradation in POE-containing modules, where the G/POE/G configuration exhibits minimal degradation under all stress conditions that we employ.

14 SOLAR ENERGY↗

Evaluation of bifacial module technologies with combined–accelerated stress testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. Furthermore, this is attributed to previous X-ray topography and modeling work showing higher stress in cells and interconnections in glass-glass modules than glass-backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. We found light-induced degradation (LID) in module types with regenerated (inactive) cells with C-AST, suggesting the possibility of LID destabilization in some field conditions. We could also distinguish potential-induced degradation (PID) on the back of the bifacial passivated emitter and rear cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass-glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while –1200 V system voltage is applied in C-AST, supporting the conclusion that this module type with glass-glass construction would be susceptible to PID in the field.

14 SOLAR ENERGY↗

Field‐representative evaluation of PID‐polarization in TOPCon PV modules by accelerated stress testing

Abstract Potential‐induced degradation‐polarization (PID‐p) can reduce module power, but how to project the extent to which PID‐p may occur in field conditions considering the factors of system voltage, condensed moisture, temperature, and illumination has not been clarified. Using tunnel oxide passivated contact (TOPCon) modules, this work demonstrates a method to test full‐size crystalline silicon PV modules for PID‐p to provide field‐representative results. In initial screening tests with positive or negative 1000 V electrical bias applied at 60°C for 96 h using Al foil electrodes on the glass surfaces, the module type exhibited reversible PID‐p only on the front face when the cell circuit was in negative voltage potential. No PID was detected on the rear after testing in either polarity. We then evaluated the PID‐p sensitivity on the front side under different UV irradiances while maintaining the glass surface wet to estimate real‐world susceptibility to PID‐p. The magnitude of the observed behavior was fit using a previously developed charge transfer and depletion by light model. Whereas power loss with −1000 V applied to the cell circuit at 60°C for 96 h in the dark was about 30%, testing the module front under 0.051 W·m −2 nm −1 at 340 nm UVA irradiation using fluorescent tubes, the mean degradation was only 3%. When the modules were tested in the dark for PID‐p with in situ dark current–voltage (I‐V) characterization, the thermal activation energy for degradation was 0.71 eV; for recovery in the dark, it was 0.58 eV. Whereas recovery from the degraded state at 60°C in the dark without voltage bias was 5% absolute in 38 h, rapid recovery of about 5% absolute was observed with 1000 W·s/m 2 exposure at 25°C using a flash tester.

14 SOLAR ENERGY↗

Evidence of Polarization‐Type Potential‐Induced Degradation (PID‐p) in the Field and Investigation of the Recovery Mechanism on Bifacial p ‐PERC Modules

This study investigates the polarization-type potential-induced degradation (PID-p) of bifacial glass/glass p-type passivated emitter rear contact (p-PERC) modules in the field and their recovery behavior. Modules were installed with three mounting configurations providing different albedo conditions. System voltage (–600, –1500, and +1500 V) was applied to the cell circuits, with respect to the grounded module frames. No degradation was observed for positively biased modules, but PID-p was identified on the rear side when cells are negatively biased, with maximum power dropping during the first days and stabilizing at values up to 8% loss. Electroluminescence images revealed a variation of the cells' PID-p susceptibility within a module. Three parameters were shown to impact the degradation rate: rear albedo light, voltage, and wetness conditions. Degraded modules were recovered either by (1) a positive bias (+1500 V), (2) outdoor illumination with the front side facing sun, (3) outdoor illumination with the rear side facing sun, or (4) dark storage. A recovery pattern was identified with I–V parameters decreasing to a local minimum before increasing to full recovery. The proposed mechanism is based on the band bending at the rear p-type Si/AlO x/SiN x interface, going from inversion to depletion and accumulation states. Full recovery was achieved in 2–7 h for the modules recovered with the rear side facing sun, four to eight nights for the modules positively biased at night, and 10–20 days for the modules with the front side facing sun. Dark storage showed slower recovery rates as I–V parameters were not improving even after 1 month. Here, the recovery rates were correlated with the net Coulombs transferred during the preceding PID stress: When more Coulombs are transferred during the degradation, the extent of degradation is greater, leading to slower recovery rates.

14 SOLAR ENERGY↗

A Siamese CNN + KNN-Based Classification Framework for Non-intrusive Load Monitoring

Through the development of smart grids, programs such as demand side response, have been presented as auxiliary services to the real-time operation of distributed networks. In order to provide consumers information on their energy consumption, so that a modulation in consumption is possible, non-intrusive load monitoring has been introduced as an solution to this pattern recognition problem. Non-intrusive load monitoring enables the modeling of electrical loads connected to the low-voltage system, considering only a single measurement point. Presented state-of-the-art solutions though, consider availability of data as well as representation of all possible classes of the environment. This is of course a most conservative hypothesis, since in real-life applications availability of such data is much difficult, as well as the dynamic behavior of models is implicitly evolving in time. Here, a framework that uses neural Siamese networks with k-nearest neighbor clustering is presented toward non-intrusive load monitoring. Online learning feature is implemented, which relaxes the hypothesis of data requirements as well addresses the evolving nature of load profile. k-nearest clustering allows nonlinear characteristic space modelling. Test results using synthetics and real-life data show that the solution, besides obtaining a good generalizability in the classification, also obtained results with an accuracy of 95.77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Polarization-type potential-induced degradation in bifacial PERC modules in the field

This study examines the susceptibility of bifacial glass/glass passivated emitter and rear cell (PERC) modules to potential-induced degradation-polarization (PID-p) in the field. While there are several studies showing PID-p occurring on both front and back faces of bifacial PERC in accelerated tests, we address the yet unclarified behavior in fielded modules. We examine the effects of mounting configuration; specifically, comparing modules mounted near ground and in elevated ground rack configurations. Modules with the cell circuit in -1500 V system voltage configuration, whether mounted on racks about 30 cm above the ground or elevated 2 m high showed mean degradation of 4.5% to 6% in power under standard test conditions over about 2.5 weeks as measured from the front side of the module. This extent of degradation remained sustained for a duration of about 6 months analyzed. Average daytime temperatures of modules in the various mounting configurations were similar and therefore judged to be insufficient to be a primary influence for the modest PID-p rate differences that we observed among mounting configurations. Increased leakage current in the morning suggests morning dew was sustained longer on modules near the ground measured over six months which would be expected to increase the PID-p rate over the long term. However, the main difference seen between the modules on the various mountings during the initial period with up to 6% mean degradation by PID-p was the approximately two times the irradiance from albedo on the rear of modules mounted in elevated ground rack compared to those on the near ground rack. This difference in incident albedo led to a modestly reduced rate of the development of PID-p of the modules on the elevated ground rack. The difference is attributed to the dissipation of PID-p-causing electrical charge by the albedo incident on the module rear. The behavior could be modeled by a sigmoidal equation with consideration of the differences in the insolation on the module rear.

14 SOLAR ENERGY↗

Design, performance, and grounding aspects of the International Thermonuclear Experimental Reactor ion cyclotron range of frequencies antenna

ITER's Ion Cyclotron Range of Frequencies (ICRF) system [Lamalle et al., Fusion Eng. Des. 88, 517–520 (2013)] comprises two antenna launchers designed by CYCLE (a consortium of European associations listed in the author affiliations above) on behalf of ITER Organisation (IO), each inserted as a Port Plug (PP) into one of ITER's Vacuum Vessel (VV) ports. Each launcher is an array of 4 toroidal by 6 poloidal RF current straps specified to couple up to 20 MW in total to the plasma in the frequency range of 40 to 55 MHz but limited to a maximum system voltage of 45 kV and limits on RF electric fields depending on their location and direction with respect to, respectively, the torus vacuum and the toroidal magnetic field. A crucial aspect of coupling ICRF power to plasmas is the knowledge of the plasma density profiles in the Scrape-Off Layer (SOL) and the location of the RF current straps with respect to the SOL. The launcher layout and details were optimized and its performance estimated for a worst case SOL provided by the IO. The paper summarizes the estimated performance obtained within the operational parameter space specified by IO. Aspects of the RF grounding of the whole antenna PP to the VV port and the effect of the voids between the PP and the Blanket Shielding Modules (BSM) surrounding the antenna front are discussed. These blanket modules, whose dimensions are of the order of the ICRF wavelengths, together with the clearance gaps between them will constitute a corrugated structure which will interact with the electromagnetic waves launched by ICRF antennas. The conditions in which the grooves constituted by the clearance gaps between the blanket modules can become resonant are studied. Simple analytical models and numerical simulations show that mushroom type structures (with larger gaps at the back than at the front) can bring down the resonance frequencies, which could lead to large voltages in the gaps between the blanket modules and perturb the RF properties of the antenna if they are in the ICRF operating range. The effect on the wave propagation along the wall structure, which is acting as a spatially periodic (toroidally and poloidally) corrugated structure, and hence constitutes a slow wave structure modifying the wall boundary condition, is examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FPGA implementation of high-frequency multiple PWM for variable voltage variable frequency controller

In this paper, we present the FPGA implementation of the multiple pulse width modulation (MPWM) signal generation with repetition of data segments, applied to the variable frequency variable voltage systems and specially at to the photovoltaic water pumping system, in order to generate a signal command very easily between 10 Hz to 60 Hz with a small frequency and reduce the cost of the control system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Voltage in Noble Liquids for High Energy Physics

A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at developing high voltage systems in noble liquids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Current Transfer from PV Modules Based on Meteorological Data

Current transferred from the active cell circuit to ground in modules undergoing potential-induced degradation (PID) stress is analyzed with respect to meteorological data. Duration and coulombs transferred as a function of whether the module is wet (from dew or rain) or the extent of uncondensed surface humidity are quantified based on meteorological indicators. With this, functions predicting the mode and rate of coulomb transfer are developed for use in estimating the relative PID stress associated with temperature, moisture, and system voltage in any climate. Current transfer in a framed crystalline silicon module is relatively high when there is no condensed water on the module, whereas current transfer in a thin-film module held by edge clips is not, and displays a greater fraction of coulombs transferred when wet compared to the framed module in the natural environment.

14 SOLAR ENERGY↗

Correction for Metastability in the Quantification of PID in Thin-Film Module Testing

A fundamental change in the analysis for the accelerated stress testing of thin-film modules is proposed, whereby power changes due to metastability and other effects that may occur due to the thermal history are removed from the power measurement that we obtain as a function of the applied stress factor. In this work, initial thermal treatment of the module is performed before application of the independent variable stress of system voltage so that any temperature-dependent processes (e.g., diffusion) that affect the module power are largely activated beforehand. Secondly, the power of reference modules normalized to an initial state-undergoing the same thermal and light exposure history but without the applied stress factor such as humidity or voltage bias-is subtracted from that of the stressed modules. For better understanding and appropriate application in standardized tests, the method is demonstrated and discussed for potential-induced degradation testing in view of the paralleloccurring but unrelated physical mechanisms that can lead to confounding power changes in the module.

14 SOLAR ENERGY↗

Comparison of Power System Current Sensors via Playback of Electrical Disturbances

The need to accurately measure high-frequency content in power system voltage and current phenomena is increasingly becoming more of a priority. As the amount of distributed energy resources (DER) and nonlinear loads penetrating the grid increases, so do challenges associated with traditional measurement and metering applications. In this paper, three commercially-available medium-voltage-level current sensors are characterized in terms of their harmonic amplitude and phase performance against reference signals that are “played back” through the sensors through the use of an arbitrary waveform generator. It is shown that none of the three sensors studied are able to faithfully replicate all of the input signals completely, though there are advantages and disadvantages to each in terms of noise, resonance, and induced phase drift. Additionally, the Goodness-of-Fit metric, typically used for PMU model validation, is used to generate side-by-side comparisons of sensor accuracy over a small window around the events under study.

Wilson, Aaron↗

COMPASS-FME Synoptic Sites Level 1 Sensor Data v1-2

This is the version 1-2 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our synoptic field sites. COMPASS-FME is studying sites in two distinct regions, the Chesapeake Bay and the Western Lake Erie Basin. We established the network at seven "synoptic" (observational) sites along the Chesapeake Bay and Lake Erie coastlines, collectively generating over three million observations per month, to track and comprehend environmental changes where land and water intersect. Additionally, the two regions provide an interesting contrast of saltwater and freshwater coasts that allow us to differentiate the impacts of inundation and coastal water chemistries in two nationally important coastal systems.L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds and out-of-service flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project**This dataset includes:- An overall dataset README file that describes the current version, gives citation and contact information, etc.- Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year.- Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, as well as a general description of the site.- Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v1-2 Synoptic L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning.

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) Experiment Level 1 Sensor Data v1-2

This is the version 1-2 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental site. This manipulative, ecosystem-scale TEMPEST experiment addresses the potential for freshwater and estuarine-water disturbance events to alter tree function, species composition, and ecosystem processes in a deciduous coastal forest in MD, USA. The experiment uses a large-unit (2000 m2), un-replicated experimental design, with three 50 m × 40 m plots serving as control, freshwater, and estuarine-water treatments.L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds and out-of-service flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project**This dataset includes:- An overall dataset README file that describes the current version, gives citation and contact information, etc.- Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year.- Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site.- Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes.Please see v1-2 TEMPEST L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning.The TEMPEST flood events occurred on the following dates. They lasted for ~10 hours each day and delivered ~80,000 gallons to each plot; many data streams are available at 1 or 5 minute frequency during these periods.* Tests: Aug 25 (fresh plot) and Sep 9 (salt plot), 2021* TEMPEST 1: June 22, 2022* TEMPEST 2: June 6-7, 2023* TEMPEST 3: June 11-13, 2024

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Synoptic Sites Level 1 Sensor Data v2-1

This is the version 2-1 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our synoptic field sites. COMPASS-FME is studying sites in two distinct regions, the Chesapeake Bay and the Western Lake Erie Basin. We established the network at seven "synoptic" (observational) sites along the Chesapeake Bay and Lake Erie coastlines, collectively generating over three million observations per month, to track and comprehend environmental changes where land and water intersect. Additionally, the two regions provide an interesting contrast of saltwater and freshwater coasts that allow us to differentiate the impacts of inundation and coastal water chemistries in two nationally important coastal systems. L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds, out-of-service, and outlier flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project** This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v2-0 Synoptic L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning. This dataset was updated 2026-03-12: (i) data now go through 2025-12-31 (previous end was 2025-06-30) and (ii) dataset and file names updated to “…v2-1” (previously was “v2-0”).

54 ENVIRONMENTAL SCIENCES↗