Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “slots”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Python-Cubit® Enhancement Scripts: 16.18

The Python-Cubit® enhancement code base is intended to be used as an extension to already existing Cubit® functionality. It provides the user with a number of functionalities that are either currently outside the realm of the python functions which Cubit® supplies internally (such as vector math), or that are comprised of commonly used combinations of already existing python functionalities (such as removing a full round from a slot cut).

97 MATHEMATICS AND COMPUTING↗

Enhancements Of Interior Flux In Magnetic Bodies & Exterior Surface Fields On Conducting Objects Of Various Shapes

The magnetic flux induced in magnetic bodies of several shapes are examined. In addition the surface magnetic field intensity on the exterior surface of conducting objects is estimated since it is the driver for narrow slot aperture inductive ports of entry. In this report lower frequencies are the focus, but we also include the magnetic field intensity of a conducting cylinder near the first resonance and a reference to the high frequency limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pre-metered coating flow models with Goma 7: Workflow Tutorial

Tutorials for modeling of slot-die and slide-die coating flows with Goma 7, an open source finite element code, are presented. The tutorials cover the workflow to attaining steady state solutions for these flows, and continuation strategies for navigating the operating windows. Advanced topics of coating window prediction, automated multiparameter continuation, non-Newtonian rheology, dynamic contact line modeling, and some more solution strategies are also covered.

08 HYDROGEN↗

CFD Modeling of an 81" Single Slope Barrier Wall Drainage Window for on Grade and Sag Conditions

The main goal of this study is to design a drainage window in an 81" single slope barrier wall for on-grade and sag conditions that could replace the standard ODOT I-3 barrier catch basin. The ODOT design guidelines are as follows: a) Examine configurations of the opening to the flume behind the wall under the wall section to maximize conveyance of flow to a roadside ditch section. b) Examine window lengths and configurations to maximize hydraulic efficiency on a grade up to an absolute maximum window length of 20 ft. c) Use a minimum opening height of 4 in. and consider tapering to an increased height at the outlet to the flume to reduce the potential for debris clogging beneath the barrier section. On-grade locations are analyzed for longitudinal slope up to 5% and spread up to 10 ft. Sag locations, represented by pavement at zero longitudinal slope, are analyzed for water depths up to 18 in. The roadway cross section consists of a 10-ft shoulder at a 4.0% cross slope and pavement at a 1.6% cross slope. All surfaces are represented with Manning’s n = 0.015. Computational fluid dynamics (CFD) is used to perform the analysis. The modeling approach follows previous studies by the authors. The new design is similar to a slotted inlet: a rectangular opening cut into the bottom of a barrier (e.g., a temporary barrier or single slope barrier wall), which typically has a uniform cross section. Findings from laboratory tests of flow under Florida DOT barrier walls were used for additional validation of the modeling approach used in this study.

42 ENGINEERING↗

High Efficiency 2-Bladed Utility Wind Turbine Enhanced by CoFlow Jet Active Flow Control

The aerodynamic performance and power output of a high efficiency Co-Flow Jet (CFJ) 2-bladed Wind Turbine is studied in this paper. CFJ is a Zero-Net-Mass-Flux (ZNMF) active flow control method that dramatically increases airfoil lift coefficient and suppresses flow separation at a low energy expenditure. The 3D Reynolds Averaged Navier-Stokes (RANS) equations with one-equation Spalart-Allmaras (SA) turbulence model are solved to simulate the 3D flows of the wind turbines. The CFJ-Wind Turbine in this paper is modified from the NREL 3-bladed 3.4 MW reference wind turbine with the same RPM, blade length, distribution of chord, twist, and bending. The CFJ 2-bladed wind turbine utilizes the CFJ-NACA 64 series airfoils at most of the blade span from 31.88\% to the tip. The CFJ injection and suction slots are implemented along the full blade span to enhance the effectiveness and power output. The study shows that the 2-bladed CFJ turbine significantly increases power output compared with the 3-bladed baseline turbine at all wind speeds by 15.8\% at the wind speed of 9.8 m/s and by 25.9\% at 4 m/s respectively. The efficiency enhancement is substantially more at the low wind speed than at high wind speed. This would be very beneficial to increase the annual power output or capacity factor as wind turbines work at the speeds lower than the rated speed for most of the time. The results show that the flow field around the blade surface presents a significant enhanced suction peak near the blade leading edge, which results in a very high tangential force and thus increased wind turbine net power coefficient. Consistent with the previous study for the small NREL Phase VI research wind turbine, this paper demonstrates that CFJ 2-bladed wind turbine is an effective technology to extract more power from the wind at all speeds. This study is just an initial effort to demonstrate the advantage of the CFJ blade with no design optimization. It is believed that there is more potential to further enhance the efficiency improvement.

active flow control↗

Acute Stent-Induced Endothelial Denudation: Biomechanical Predictors of Vascular Injury

Recent concern for local drug delivery and withdrawal of the first Food and Drug Administration-approved bioresorbable scaffold emphasizes the need to optimize the relationships between stent design and drug release with imposed arterial injury and observed pharmacodynamics. In this study, we examine the hypothesis that vascular injury is predictable from stent design and that the expanding force of stent deployment results in increased circumferential stress in the arterial tissue, which may explain acute injury poststent deployment. Using both numerical simulations and ex vivo experiments on three different stent designs (slotted tube, corrugated ring, and delta wing), arterial injury due to device deployment was examined. Furthermore, using numerical simulations, the consequence of changing stent strut radial thickness on arterial wall shear stress and arterial circumferential stress distributions was examined. Regions with predicted arterial circumferential stress exceeding a threshold of 49.5 kPa compared favorably with observed ex vivo endothelial denudation for the three considered stent designs. In addition, increasing strut thickness was predicted to result in more areas of denudation and larger areas exposed to low wall shear stress. We conclude that the acute arterial injury, observed immediately following stent expansion, is caused by high circumferential hoop stresses in the interstrut region, and denuded area profiles are dependent on unit cell geometric features. Such findings when coupled with where drugs move might explain the drug–device interactions.

Conway, Claire↗

Wireless Passive Ceramic Sensor for Far-Field Temperature Measurement at High Temperatures

A passive wireless high-temperature sensor for far-field applications was developed for stable temperature sensing up to 1000 °C. The goal is to leverage the properties of electroceramic materials, including adequate electrical conductivity, high-temperature resilience, and chemical stability in harsh environments. Initial sensors were fabricated using Ag for operation to 600 °C to achieve a baseline understanding of temperature sensing principles using patch antenna designs. Fabrication then followed with higher temperature sensors made from (In, Sn) O2 (ITO) for evaluation up to 1000 °C. A patch antenna was modeled in ANSYS HFSS to operate in a high-frequency region (2.5–3.5 GHz) within a 50 × 50 mm2 confined geometric area using characteristic material properties. The sensor was fabricated on Al2O3 using screen printing methods and then sintered at 700 °C for Ag and 1200 °C for ITO in an ambient atmosphere. Sensors were evaluated at 600 °C for Ag and 1000 °C for ITO and analyzed at set interrogating distances up to 0.75 m using ultra-wideband slot antennas to collect scattering parameters. The sensitivity (average change in resonant frequency with respect to temperature) from 50 to 1000 °C was between 22 and 62 kHz/°C which decreased as interrogating distances reached 0.75 m.

47 OTHER INSTRUMENTATION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Damaged Fuel in the United States

Over the years of commercial nuclear power plant operations in the United States (U.S.), many fuel assemblies have lost the capability to perform all of their desired functions. These assemblies have lost the capability to be handled, stored, or transported to meet regulations resulting in them being classified as damaged fuel. The causes of these failed assemblies are diverse and plant-specific. The majority of these failed assemblies are contained in a damaged fuel can that will be used in conjunction with a storage and/or transportation system. The storage and transportation systems have a limit on how many slots can be filled with damaged fuel cans. A damaged fuel can is generally a stainless steel container that confines damaged SNF and is closed on its end by screened openings. These screened openings allow gaseous and liquid media to escape but minimize the dispersal of gross particulate material. Out of an abundance of caution a few reactors have loaded high burnup fuel into damaged fuel cans. Damaged fuel is not licensed for storage or transport in the U.S., because the regulations for storage and transport do not specify exactly how to classify damaged fuel. Instead the regulations license/certify packages that specify approved contents. Damaged fuel must be included in the approved contents to be a viable option. In many cases damaged SNF is encapsulated in a damaged fuel can to ensure it can confine gross fuel particles, debris, and or damaged assemblies to a known volume within a loaded cask. This damaged fuel can may then be utilized in the same way as an assembly in a storage and transportation design system. Some storage cask systems utilize top and bottom plugs to confine debris in damaged fuel. The most recent domestic documentation on damaged SNF was performed by the U.S. Energy Information Administration (EIA) and used data from U.S. reactors concluding in June 30th 2013 to produce Form GC-859, “Nuclear Fuel Data Survey”. Based on this form there were 136,821 boiling water reactor (BWR) spent nuclear fuel (SNF) assemblies and 104,647 pressurized water reactor (PWR) SNF assemblies for a total of 241,468 SNF assemblies in the U.S. Out of these 241,468 SNF assemblies, 4,521 assemblies were classified as failed. Some assemblies were also disassembled and the fuel rods or pieces of fuel rods were combined together to make a consolidated assembly. A consolidated assembly may include damaged fuel, or it could have been consolidated as part of a demonstration project. The GC-859 data includes 2,550 consolidated assemblies containing between 0 and 264 whole fuel rods. These consolidated assemblies could be placed in single assembly canisters and stored in the spent fuel pool. For dry storage and transportation, a single assembly canister is generally placed in a damaged fuel can. In addition to the consolidated assemblies, 2,391 uncanistered fuel rod pieces exist, which were removed from 494 assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Influence of Coating Method on the Performance of Roll-to-Roll Coated PEM Fuel Cell Catalyst Layers

As production of fuel cell vehicles and power systems increases there is a need to understand the process science of fuel cell manufacturing. Industrial production of polymer electrolyte membrane fuel cell (PEMFC) electrodes will rely on continuous roll-to-roll (R2R) coating methods to meet the rates needed for mass production. There are a variety of coating methods that could be used to coat catalyst layers. The different physics of each method may result in different morphologies and performance. Here we present the results of a study comparing fuel cell catalyst layers coated using two R2R coating methods: slot-die and gravure. These two methods were selected because the physics of applying the liquid to the substrate is very different between the two cases. Pt/C catalysts layers were coated directly onto carbon-fiber gas diffusion media to create gas diffusion electrodes (GDEs), without the use of a decal transfer process. These GDEs were assembled into membrane electrode assemblies (MEAs) by hot pressing to Nafion membranes. In situ performance and other electrochemical diagnostics were used to determine the influence of coating method on catalyst layer electrochemical properties. Electron microscopy was utilized to understand the influence of coating method on electrode morphology and its influence on electrochemical properties. We also explored the influence of solvent ratio to understand the potential coupling between ink formulation and coating methodology.

DIRECT ENERGY CONVERSION,MATERIALS SCIENCE↗

Optimizing branch re-wiring in a software instruction cache

A method includes a computer device receiving a branch instruction; the computer device managing two tables, where a first table relates to application blocks and a second table relates to available address slots; and the computer device calculating a target of the branch instruction using a branch-to-link register, the computer device optimizes re-wiring in a cache using the calculation and the managed two tables.

97 MATHEMATICS AND COMPUTING↗

Hermetic edge-connect headers and corresponding connectors

A hermetically-sealed edge-connect header that can withstand high temperatures, high pressures (or high vacuum levels), and high vibration environments, along with two corresponding connectors are disclosed. After brazing the edge-connect header components, the assembly is machined to form a slot with a portion of each of a plurality of electrical conductors removed in the machining process, resulting in a header with a high pin density. During the process of mating the first connector design to the edge-connect header, a plurality of wipers in the connector deflect, thereby causing the wipers to extend from the connector and contact the corresponding electrical conductors in the header. During the process of mating the second connector design to the edge-connect header, each of a plurality of wipers formed of low-mass, compliant metal wool, forms multiple contact points with a corresponding electrical conductor in the header.

Kellogg, Rick A.↗

Microfabricated ion trap chip with an integrated microwave antenna

An ion trap chip, which may be used for quantum information processing and the like, includes an integrated microwave antenna. The antenna is formed as a radiator connected by one of its ends to the center trace of a microwave transmission line and connected by its other end to a current return path through a ground trace of the microwave transmission line. The radiator includes several parallel, coplanar radiator traces connected in series. The radiator traces are connected such that they all carry electric current in the same direction, so that collectively, they simulate a single, unidirectionally flowing sheet of current. In embodiments, induced currents in underlying metallization planes are suppressed by parallel slots that extend in a direction perpendicular to the radiator traces.

Nordquist, Christopher↗

Curved seal for adjacent gas turbine components

A flexible seal for sealing between two adjacent gas turbine components includes a forward end, an aft end axially separated from the forward end, and an intermediate portion between the forward end and the aft end. The intermediate portion defines a continuous curve in the circumferential direction, such that the aft end is circumferentially offset from the forward end. In other cases, the forward and aft ends are axially, radially, and circumferentially offset from one another. A method of sealing using the flexible seal includes inserting, in an axial direction, the aft end of the flexible seal into a recess defined by respective seal slots of two adjacent gas turbine components; and pushing the flexible seal in an axial direction through the recess until the forward end is disposed within the recess.

Sarawate, Neelesh Nandkumar↗

Speculative instruction wakeup to tolerate draining delay of memory ordering violation check buffers

A technique for speculatively executing load-dependent instructions includes detecting that a memory ordering consistency queue is full for a completed load instruction. The technique also includes storing data loaded by the completed load instruction into a storage location for storing data when the memory ordering consistency queue is full. The technique further includes speculatively executing instructions that are dependent on the completed load instruction. The technique also includes in response to a slot becoming available in the memory ordering consistency queue, replaying the load instruction. The technique further includes in response to receiving loaded data for the replayed load instruction, testing for a data mis-speculation by comparing the loaded data for the replayed load instruction with the data loaded by the completed load instruction that is stored in the storage location.

Kalamatianos, John↗

Circumferential flow foam heat exchanger

A heat exchanger is disclosed that includes a cold heat exchange zone including a foam material having an annular geometry and having fluid distribution and collection slots configured to distribute a cooling fluid circumferentially through the foam material.

Youchison, Dennis L.↗

MCNP TREAT Core Model with Big-BUSTER

This MCNP model contains the Big-BUSTER experiment containment system within the TREAT core in a half slot configuration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Curved seal with relief cuts for adjacent gas turbine components

A flexible seal is used to seal between two adjacent gas turbine components. The flexible seal includes at least one metal ply having a forward end, an aft end axially separated from the forward end, and an intermediate portion between the forward end and the aft end. The intermediate portion defines a continuous curve in the circumferential direction, such that the aft end is circumferentially, and optionally radially, offset from the forward end. A plurality of relief cuts is defined through the at least one metal ply between the forward end and the aft end to increase flexibility and improve sealing in seal slots that are radially offset from one another.

Sarawate, Neelesh Nandkumar↗