Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “muon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Low Energy Muon Capture and Transport from a Heavy Target

The MeV Test Area (MTA) secondary beamline is currently designed to produce and capture a low energy pion beam that then produces a tertiary muon beam via decay along the secondary line. The challenge presented in capturing muons from low-energy decay-in-flight pions, is the large decay angle that results from the low momentum. The current air-core quadruples lack the strength to bend/capture muons at large angles. Recently much stronger 400- MeV Linac quadrupoles have become available which are capable of strong focusing and large-angle capture. Initial results from this upgrade and reconfiguration indicate a major improvements in angle acceptance and transport ability for low-energy muons.

Winter, Wesley↗

Final Cooling with Thick Wedges for a Muon Collider

A muon collider is a particle accelerator that collides muons rather than protons or electrons. An important component of such a collider is cooling, in which the emittance of the muon beam is reduced to make it suitable for use in a collider. In the last stage of this process, called final 4D cooling, emittance in the transverse axes is reduced while emittance in the longitudinal axis is allowed to grow. In previous studies, Final 4-D cooling used absorbers within very high field solenoids to cool low-momentum muons. Simulations of the systems did not reach the desired cooling design goals. In this study, we develop and optimize a different conceptual design for the final 4D cooling channel, which is based on single thick wedges. We used G4Beamline to simulate the channel and Python to generate and analyze particle distributions. We characterized the effects of various parameters on the performance of this system, including the initial emittances and Twiss parameters, the length and angle of the wedges, the length of the drift channel, and the length, frequency, gradient, and phase of the RF cavities. We optimized the design parameters of the cooling channel and produced two conceptual designs (corresponding to two possible starting points for the input beam) which achieve transverse cooling in both x and y by a factor of ≈ 3.5. These channels achieve a lower transverse and longitudinal emittance than the best design previously published.

43 PARTICLE ACCELERATORS↗

Measurements of Pion and Muon Nuclear Capture at Rest on Argon in the LArIAT Test Beam Experiment

LArIAT is a liquid argon time projection chamber (LArTPC) experiment in a test beam at Fermilab from 2015 to 2017 to understand and characterize interactions of particles in LAr which are commonly observed in neutrino-Ar final-states. Tracks for pions and muons in LArTPCs are difficult to differentiate since both particles exhibit very similar ionization profiles for muon and pion that stop in the TPC. We are exploring unique new particle discrimination capabilities by exploiting information from small, isolated ionization depositions, referred to as "blips", reconstructed near the endpoint of stopping tracks. These blips are formed by gammas emitted when an at-rest pion or muon captures on the argon nucleus. The relatively low beam energy provided by LArIAT makes it uniquely suited for performing this demonstration. In this poster, we present an overview of event candidate selection, blip reconstruction, and background subtraction corresponding to our signal of interest, nuclear captures of pions and muons at rest inside LArIAT's TPC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Muon g-2 Experiment at Fermilab: Precision Measurements and Nonlinear Beam Dynamics

The Muon g-2 Experiment has achieved a significant milestone by measuring the positive muon anomalous magnetic moment to an unprecedented accuracy of 0.20 ppm, paving the way to a better understanding of particle physics, including beyond-the-Standard-Model possibilities. In the experiment, muons are circulated within a storage ring, and their anomalous precession frequency — the spin precession relative to momentum — is determined from decay positron time and energy data, captured using calorimeters. In support of accurate storage ring simulations, we performed high-order calculations of the field of the experiment's high-voltage quadrupoles. We also carried out accurate, transfer map–based calculations of the storage ring's chromaticity. These calculations are essential for understanding the beam dynamics effects in the Muon g-2 storage ring.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lost Muons Analysis

The Muon g-2 experiment at FermiLab represents a significant scientific endeavor aimed at measuring the anomalous magnetic moment of the muon, $a_µ$, with a precision of 140 parts per billion (ppb). During my internship at FermiLab, I focused on the simulation and analysis of Lost Muons, a critical aspect to ensure the accuracy of the experimental results. I conducted a detailed study of the beam dynamics using the existing simulation, I generated a new simulation sample enrich of events with lost muons, I analyzed it and compared the results I obtained with those from the Run-2 dataset acquired by the experiment. In this report I will briefly describe my work, discuss the results and suggest future improvements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The muon g-2 experiment at Fermilab

The E989 collaboration has recently published the most precise measurement of the muon anomalous magnetic moment $a_\mu$ with an uncertainty of $0.46\,\mathrm{ppm}$. The new experimental world average of $a_\mu$ deviates by 4.2 standard deviations from the Standard Model prediction provided by the Muon g-2 Theory Initiative. Emerging results from ab-initio lattice QCD calculations for hadron-physics contributions allow to scrutinize this tantalizing hint for physics beyond the Standard Model for the first time in a three way comparison. To extract the value of $a_\mu$ a frequency comparison experiment is performed with spin-polarized muons confined in a superbly controlled electric and magnetic field environment. A measurement of the difference between the Larmor and the cyclotron frequency, the so-called anomalous spin precession frequency, is combined with a high-precision measurement of the magnetic field environment which is performed using nuclear magnetic resonance techniques. I discussed the most recent result of the Fermilab Muon g-2 experiment's first physics data run performed in 2018. I reported on the experimental improvements implemented for the subsequent science runs that will allow the collaboration to achieve the ultimate goal of $0.14\,\mathrm{ppm}$ uncertainty on $a_\mu$.

Fertl, Martin↗

Muon Radiography with the NOvA Near Detector

Information on the geological and man-made structures, directly contributing to the overburden of the NOvA Near Detector, located 100 m underground at Fermilab, are extracted from the cosmic muon data accumulated in the period April 2015 - October 2016. Results of this radiographic analysis of cosmic data are obtained by exploiting the acceptance symmetries of the NOvA detector. Radiographic maps of the overburden variations are acquired without subtracting the surface muon flux (free sky data) and without MC simulation of the cosmic muons attenuation in the homogeneous and flat overburden. By directly subtracting the angular muon track data measured by the NOvA Near Detector, arriving from directions having the same attenuation length (in the flat-surface approximation) and belonging to the acceptance regions with the same reconstruction efficiency, one can efficiently obtain two-dimensional differential radiographic maps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small experiment, Big Data: the data production of the Muon $g-2$ Experiment

The Muon $g-2$ Experiment at Fermilab aims to measure the muon anomalous magnetic moment with the unprecedented precision of 140 parts per billion (ppb). In April 2021 the collaboration published the first measurement, based on the first year of data taking. The result confirmed the previous experiment at Brookhaven National Laboratory (BNL), and increased the long-standing tension with the Standard Model prediction to 4.2 $\sigma$. The experiment is now running the sixth year of data acquisition of positive muon data, having accumulated a total of $\sim$19 times the statistics of the BNL experiment. A collaboration-wide effort is now in place to help produce the multi-petabyte-sized data sets, a challenge typically faced by much bigger experiments. Having a quick production turnaround time is of critical importance in order to achieve a timely analysis and publication schedule. In this paper I will describe the production workflow, the former and current challenges, the resources, tools, and the future prospects of the Muon $g-2$ Experiment.

Girotti, Paolo↗

Design and construction of Cosmic Muon Veto for the mini-ICAL detector at IICHEP, Madurai

A 51-kiloton magnetised Iron Calorimeter (ICAL) detector, using Resistive Plate Chambers (RPCs) as active detector elements, aims to study atmospheric neutrinos. A prototype - 1/600 of the weight of ICAL, called mini-ICAL was installed in the INO transit campus at Madurai. A modest proof-of-principle cosmic muon veto detector of about 1 m×1 m×0.3 m dimensions was set up a few years ago, using scintillator paddles. The measured cosmic muon veto efficiency of 99.98% and simulation studies of muon-induced background events in the ICAL detector surrounded by an efficient veto detector were promising. This led to the idea of constructing a bigger cosmic muon veto around the mini-ICAL detector. Details of the design, fabrication, quality control, and construction of the detector including the electronics, trigger, and DAQ systems planned will be briefly presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Core-corona hadronization model and muon puzzle in extensive air showers

The discrepancy between models and measurements concerning the muon content in air showers produced by ultra-high energy cosmic rays, the so-called muon puzzle, remains unsolved. String fragmentation models currently used in hadronic interactions fail to reproduce the observations, while recent measurements at the LHC hint towards the existence of production mechanisms, such as collective statistical hadronization, which lead to an increase in the muon production after a hadronic interaction. The core-corona model of heavy ions implements both production mechanisms, where the large-density region of interaction (core) hadronizes statistically, while the low-density (corona) hadronizes following string fragmentation. In this contribution, we present a modification of the CONEX framework to implement the core-corona model in air shower simulations. We demonstrate a significant impact of the core effect, as observed at the LHC, on the muon content in air showers produced by ultra-high energy cosmic rays.

79 ASTRONOMY AND ASTROPHYSICS↗

United States Muon Collider Community White Paper for the European Strategy for Particle Physics Update

This document is being submitted to the 2024-2026 European Strategy for Particle Physics Update (ESPPU) process on behalf of the US Muon Collider community, with its preparation coordinated by the interim US Muon Collider Coordination Group. The US Muon Collider Community comprises a few hundred American scientists. The purpose of the document is to inform ESPPU about the US plans for Muon Collider research and development (R&D), explain how these efforts align with the broader international R&D initiatives, and present the US community vision for the future realization of this transformative project.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Material science and solid state physics studies with positive muon spin precession

The hyperfine field on the muon, B sub hf, at interstitial sites in dilute Fe(Al) alloys was measured for four different concentrations of Al and as a function of temperature by the muon spin rotation method. The magnitude of B sub hf, which is negative, decreases at rates ranging from 0.09 + or - 0.03% per at.% Al at 200 K to an asymptotic limit of 0.35 + or - far above 440 K. This behavior shows that sites near the Al impurity are weakly repulsive to the muon, with an interaction potential of 13 + or - 3 meV. In order to fit the temperature dependence of the hyperfine field, it is necessary to hypothesize the existence of a small concentration of unidentified defects, possibly dislocations, which are attractive to the muon. Although the Al impurity acts as a non-magnetic hole in the Fe lattice, the observed decrease in B sub hf is only 35% of the decrease in the bulk magnetization. It is concluded that B sub hf is determined mainly by the enhanced screening of conduction electrons in Fe and Fe(Al). Since the influence of the Al impurity on the neighboring Fe monents is very small, most of the change in B sub hf is therefore attributed to the increase in conduction electron polarization of the Al impurity.

Stronach, C. E.↗

Measurement of energy muons in EAS at energy region larger thean 10(17) eV

A measurement of low energy muons in extensive air showers (EAS) (threshold energies are 0.25, 0.5, 0.75 and 1.38 GeV) was carried out. The density under the concrete shielding equivalent to 0.25 GeV at core distance less than 500 m and 0.5 GeV less than 150 m suffers contamination of electromagnetic components. Therefore the thickness of concrete shielding for muon detectors for the giant air shower array is determined to be 0.5 GeV equivalence. Effects of photoproduced muons are found to be negligible in the examined ranges of shower sizes and core distances. The fluctuation of the muon density in 90 sq m is at most 25% between 200 m and 600 m from the core around 10 to the 17th power eV.

Matsubara, Y.↗

Muons in gamma showers

Muon production in gamma-induced air showers, accounting for all major processes. For muon energies in the GeV region the photoproduction is by far the most important process, while the contribution of micron + micron pair creation is not negligible for TeV muons. The total rate of muons in gamma showers is, however, very low.

Stanev, T.↗

A large area cosmic muon detector located at Ohya stone mine

The chemical composition of the primary cosmic rays between 10 to the 15th power eV and 10 to the 18th power eV were determined by a Large Area Cosmic Muon Detector located at Ohya stone mine. The experimental aims of Ohya project are; (1) search for the ultra high-energy gamma-rays; (2) search for the GUT monopole created by Big Bang; and (3) search for the muon bundle. A large number of muon chambers were installed at the shallow underground near Nikko (approx. 100 Km north of Tokyo, situated at Ohya-town, Utsunomiya-city). At the surface of the mine, very fast 100 channel scintillation counters were equipped in order to measure the direction of air showers. These air shower arrays were operated at the same time, together with the underground muon chamber.

Nii, N.↗

An upper limit of muon flux of energies above 100 TeV determined from horizontal air showers observed at Akeno

Muon energy spectrum above 100 TeV was determined by observing the extensive air showers (EAS) from the horizontal direction (HAS). No definite muon originated shower of sizes above 100,000 and zenith angles above 60 deg was observed. The upper limits of HAS intensity is 5x10/12 m/2 s/1 sn/1 above 100,000. It is indicated that the upper limit of muon flux above 100 TeV is about 1.3x10/8 m/2 s/1 sr/1 and is in agreement with that expected from the primary spectrum with a knee assuming scaling in the fragmentation region and 40% protons in the primary beam. The critical energy at which muon flux from prompt processes take over that from the conventional process is higher than 100 Tev at horizontal direction.

Nagano, M.↗

On method of muon spectrum measurements by the scintillation detectors of a large thickness T4t sub o

Various methods for the study of muon spectrum are presented. The direct ones include the muon energy measurements by magnetic spectrometers. The indirect ones deal with the reconstruction of the muon spectrum from the spectrum of secondary particles obtained by burst or calorimeter technique. The burst technique is based on the measurement of the number of cascade particles, mainly in the cascade maximum, by the detectors of small thickness T sub 0. The calorimeter method consist in determination of the cascade energy with help of the cascade curve shape. The multilayer detectors are used for this purpose. They are usually comprised of proportional counters, X-ray emulsion chambers or scintillation counters with the target material placed between them. The scintillation detectors of a large thickness measures the total cascade energy directly and the detector works as a true calorimeter. When the total energy is detected, the cascade spectrum differs from the muon one.

Ryazhskaya, O. G.↗

Multiple muons of conventional and exotic origin in DUMAND

A first summary of results from a theoretical analysis, based on hadron - muon cascade calculations, that yield relative intensities of very high energy multiple muons originating from ultra high energy interactions initiated by primary protons and iron nuclei in the atmosphere, under consideration of normal as well as direct and exotic production channels is presented. Lateral density distributions and target diagrams will be presented which show that only very large detectors, such as DUMAND, will be able to record multiple muons of conventional origin reliably. This, however, is a prerequisite for any primary mass determination based on multiple muon data.

Grieder, K. F.↗