SEARCH · Engineering Papers
Results for “housing”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Requirements for an in-house synchrotron radiation source at LANL
Synchrotron measurements for diffraction characterization and high resolution tomography require: (1) unable monochromatic X-ray incident energy from 65keV to 100keV. 65keV need is defined by Ta and W absorption edges at 67keV, 100keV need is defined by need to penetrate U/Pu sample thickness of 0.5 mm (2) focused flux density of the monochromatic beam on a beam spot of ~100 µm 2 greater than 10 10 photons per second to allow some slower kinetics experiments such as heating, cooling for CTE measurements (but not quenching, solidification etc. which require <0.1 s resolution) (3) Δλ/λ resolution of 0.3% or better across the energy spectrum. This can be achieved by monochromator as long as flux needs are met in the monochromatic beam.
Housing Energy Connection Project (Final Technical Report)
This project expanded existing medium-voltage distribution to 33 households, a daycare, a mechanical shop, irrigation pumps, and a sewer lift station, all of which previously received electric service from the local electric utility. As part of the project, automatic meter reading (AMR) and advanced metering infrastructure (AMI) was installed to allow the Tribe to set up its own electric metering like a utility. The primary objective of this project was to expand the Tribe-owned electrical distribution to provide highly reliable electrical service to these existing loads. The objective was successfully met after project completion. The project reduced high costs for electric energy previously supplied by the utility, by supplanting utility-supplied electric power with Tribe-generated electric power. The project gave the Tribe greater independence from traditional power sources and provided jobs for the community.
In House Synthesis of Barco Bond MB185 Precursor in a Continuous Process
Explore the source record for details and available documents.
In-House Manufacturing of New Generation Multijunction Thermal Converters at Sandia National Laboratories.
Abstract not provided.
Poly(dicyclopentadiene) (pDCPD) Coatings for the Mitigation of Surface Flashover in Gas Switch Housings.
Abstract not provided.
ResStock Communities LEAP Pilot Residential Housing Analysis - Detailed Methodology
This methodology document supports residential building analysis for some communities receiving technical assistance through the Department of Energy Communities LEAP (Local Energy Action Program). Communities LEAP supports community-wide economic and environmental benefits through technical assistance.
In-House Developed Multiphysics Simulation for the Performance of Solid Oxide Cells (SOCs)
Reversible solid oxide cells(rSOCs) are an enabling energy storage/production technology for a dynamic grid environment. Reversible operation requires strong working knowledge of fuel cell (SOFC) and electrolyzer (SOEC). Performance degradation of SOECs has been observed; however, the details of physical processes related to the performance degradation remain unknown. Multiphysics simulations were performed to investigate the performance degradation of solid oxide electrolysis cells under various working conditions.
North Birmingham Housing Energy Baseline and Upgrade Strategies [Slides]
The community of North Birmingham, Alabama, participated in the Communities LEAP pilot program. As part of this technical assistance pilot, residential buildings, energy efficiency, and electrification were analyzed. This slide deck details the baseline analysis of residential buildings in the community and potential upgrade strategies.
Microgrid Tiered Circuits Effects for a Planned Housing Community in Puerto Rico (AT-23-C059)
Explore the source record for details and available documents.
Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing
Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.
Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate
Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.
Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate
According to the 2020 residential energy consumption survey, there are 32 million multi-family buildings in the United States, and approximately 42% of these have poor or no insulation (US EIA 2020). Electrification of buildings with heat pump is one of the key strategies to achieve the goal of 90% reduction of greenhouse gas emissions in buildings by 2050 (U.S. Department of Energy 2024a). Building electrification will also enable greater penetration of variable renewable energy sources. However, replacing the natural gas dominated heating system by electrical appliance will increase the electrical load in heating dominated climate. It is crucial to well-insulate the building envelope to mitigate the stress in the grid from electrification. The hydronic shell (HS) system discussed next can achieve dual objective of envelope retrofit with space heating system electrification.
Establishing In-House Titration Capabilities: Part I. Hydroxyl Group Titration through Acetic Anhydride Acetylation
This lessons learned document provides a detailed analysis of the hydroxy termination titration methods employed for determining hydroxyl group content in various chemical samples. The primary focus is on the evaluation of techniques such as ASTM E222 and their practical applications in laboratory settings. Through examination of method selection, sample preparation, and titration execution, key insights have been identified that enhance the accuracy and reliability of results. Notable findings include the advantages of using pressure bottle methods for improved heating uniformity and reduced solvent loss, as well as the challenges associated with endpoint detection in dark-colored solutions. Recommendations for alternative sampling and titration techniques are proposed to address these challenges. This document serves as a valuable resource for enhancing the effectiveness and efficiency of hydroxy termination titration methods in chemical analysis.
Evidence for increased thermogenesis in female C57BL/6J mice housed aboard the international space station
Explore the source record for details and available documents.
Effects of Subthermoneutral Housing on Bone in Female C57BL/6J Mice
Explore the source record for details and available documents.
Cold stress during room temperature housing alters skeletal response to simulated microgravity (hindlimb unloading) in growing female C57BL6 mice
Explore the source record for details and available documents.