Achieving a robust grassy-ELM operation regime in CFETR

We have identified a robust grassy-edge localized mode (ELM) operation regime for future tokamak reactors. The regime exists within a pedestal top electron collisionality (ν*) window at high global poloidal beta (β p ). The existence of an upper ν* limit for grassy-ELMs is consistent with results previously reported in experiments (Oyama et al 2010 Nucl. Fusion 50 064014), while the existence of a lower ν* limit has not been reported previously. Using EPED and BOUT++, a theoretical model that quantitatively explains the physics of the grassy-ELMs within the window, which distinguishes them from the small mixed-ELMs at lower ν*, is presented for the first time. A peeling-ballooning stability boundary is obtained by scanning the operating density space. The change in density corresponds to a change in ν* that affects the pedestal bootstrap current. High β p leads to a strong Shafranov shift, which affects the flux surface averaged pressure drive. The two effects combine to create a peeling-dominated window in intermediate ν* buffered by ballooning-dominated regimes. Only the peeling-dominated regime shows a cyclic behavior in the perturbed pressure during the nonlinear simulation of an ELM crash, reminiscent of grassy-ELM dynamics. Similarly, the energy released across the separatrix is demonstrated to be significantly smaller. The quick recovery of the ELM crash is explainable by the rapid rise of a low n kink-peeling instability when the pedestal current I ped exceeds a threshold at high β p . It minimizes the excursion beyond marginal stability and is absent in the ballooning-dominated regime. Comparison with recent experiments over a range of β p and ν* strongly supports the physical picture proposed by the modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpreting dynamic-compression experiments to uncover the time dependence of freezing: Application to gallium

Using pulsed-power magnetic field sources to compress gallium to gigapascal pressures on nanosecond timescales, we report here experiments on shockless dynamic compression of a liquid metal. Time-resolved velocimetry data reveal signatures of rapid freezing from a metastable liquid state, and we demonstrate that the kinetics of this nonequilibrium solidification can be accurately simulated with a computational modeling framework we have developed in previous studies, where classical nucleation theory is coupled with hydrodynamics. Notably, velocity traces in some of our experiments show evidence of a phase transition, while others do not, even though other types of evidence suggest that solidification may be occurring in all of them. We explain how predictions made by our models regarding the presence or absence of these phase-transition signatures motivated additional experiments that later confirmed the theoretical predictions. Our analysis shows that due to the rapid, quasi-isentropic nature of the loading path, our experiments were able to compress liquid gallium to metastable states that are undercooled below the equilibrium melt temperature by more than 300 K and exhibit pressures that approach five times the equilibrium melt pressure. The understanding gained in this study should form the basis for future dynamic-compression experiments aimed at interrogating melt curves at high pressures.

gallium↗

Constraining self-interacting dark matter with the full dataset of PandaX-II

Self-interacting dark matter (SIDM) is a leading candidate proposed to solve discrepancies between predictions of the prevailing cold dark matter theory and observations of galaxies. Many SIDM models predict the existence of a light force carrier that mediates strong dark matter self-interactions. If the mediator couples to the standard model particles, it could produce characteristic signals in dark matter direct detection experiments. We report searches for signals of SIDM models with a light mediator using the full dataset of the PandaX-II experiment, basing on a total exposure of 132 tonne-days. No significant excess over background is found, and our likelihood analysis leads to a strong upper limit on the dark matter-nucleon coupling strength. We further combine the PandaX-II constraints and those from observations of the light element abundances in the early universe, and show that direct detection and cosmological probes can provide complementary constraints on dark matter models with a light mediator.

79 ASTRONOMY AND ASTROPHYSICS↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Integral Experiment Execution (CED-3b Report)

This report documents the experimental configurations and measurements for IER-518: Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments. These measurements involved a series of subcritical configurations at the Sandia Critical Experiments (SCX) facility at Sandia National Laboratories (SNL). The purpose of these measurements was to produce time tagged neutron count data of configurations that exceed a subcritical multiplication of 20, which is the high end of the fundamental physics benchmarks currently available in the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP). These measurements leverage experimental configurations 1 and detector systems 2 from previously accepted ICSBEP benchmark evaluations, allowing evaluations of these measurements to be performed at greatly reduced cost.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IER-580 CED-3b: Experiment Execution Summary for the Pulsed-Neutron Die-Away Experiments (PNDA) with H 2 O

This report summarizes new experiments performed with H 2 O for IER-580, a testbed for pulsed-neutron die-away (PNDA) experiments at Lawrence Livermore National Laboratory (LLNL). The experiments will become high-quality benchmarksthat serve to optimize and validate thermal neutron scattering laws (TSLs) of H 2 O, which are high-priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). The report presents the details of the measurements conducted in October of 2023, including the experimental set-up (PNDA equipment and H 2 O targets) and all experimentally measured data. The report gives the fitted decay constants for the die-away curves of each target sample. It also provides the tabulated data for the die-away curves in the appendices.

42 ENGINEERING↗

Report on progress in physics: observation of the Breit–Wheeler process and vacuum birefringence in heavy-ion collisions

This report reviews the effort over several decades to observe the linear Breit–Wheeler process ($\gamma\gamma \rightarrow e^+e^-$) and vacuum birefringence (VB) in high-energy particle and heavy-ion collider experiment. This report, motivated by the STAR collaboration's recent observations, attempts to summarize the key issues related to the interpretation of polarized $\gamma\gamma \rightarrow l^+l^-$ measurements in high-energy experiments. To that end, we start by reviewing the historical context and essential theoretical developments, before focusing on the decades of progress made in high-energy collider experiments. Special attention is given to the evolution in experimental approaches in response to various challenges, to the demanding detector capabilities required to unambiguously identify the linear Breit–Wheeler process, and to the connections with VB. Finally, we close the report with a discussion, followed by a look at near-future opportunities for utilizing these discoveries and for testing quantum electrodynamics in previously unexplored regimes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integral Experiment Request 523 Feasibility Study (Summary Report)

This report documents the feasibility phase of the Critical Experiment Design (CED) conducted as part of integral experiment request (IER) 523. The purpose of IER-523 is to explore the effects of using 35 weight percent enriched uranium dioxide-beryllium oxide (UO 2 -BeO) material on critical configurations using the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories (Sandia). Preliminary experiment design concepts, neutronic analysis results, and proposed paths for continuing the CED process are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Criticality Accident Alarm System Shielding Benchmark: Integral Experiment Request 498, Critical Engineering Decision 2 Report

A workable design to perform a CAAS benchmark experiment is detailed herein. Key dimensions, materials, source intensity levels, and detectors are listed in this report. Sensitivity to 21 perturbations was determined to be acceptable. The next step will be for NCSP management to determine whether procurement should occur and if the experiment should proceed. The perturbation study suggests that the room return shield cavity radius and runout should be maintained to within a millimeter, the room return shield should be positioned carefully (perhaps with a laser range finder), and that the detectors should be mounted in a lightweight fixture such as aluminum, so their positioning is assured. Using a 3D scanner or photogrammetry to record part shapes may be beneficial. Further work is also needed to verify source reproducibility.

36 MATERIALS SCIENCE↗

Enhanced Component Performance Study: Air Operated Valves 1998–2022

This report presents an enhanced performance evaluation of air operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The AOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for AOVs for the most recent 10 year period: • Low demand AOV frequency of FTOC demands (demands per reactor year) • High demand AOV frequency of FTOC demands. The following decreasing trends were identified for AOVs for the most recent 10 year period: • Low demand AOV FTOC failure probability • Low demand AOV FTOP failure rate • Low demand AOV frequency of FTOC events (failures per reactor year) • Low demand AOV frequency of FTOP events.

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Turbine Driven Pumps 1998–2022

This report presents an enhanced performance evaluation of turbine driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10 year period: The following decreasing trends were identified for TDPs for the most recent 10 year period: • Standby TDP FTR>1H failure rate • Normally running TDP FTR failure rate • Standby TDP unavailability • Standby MDP total unreliability (8-hour mission) • Standby TDP frequency of start demands (demands per reactor year) • Standby TDP frequency of FTR=1H hours (hours per reactor year) • Standby TDP frequency of FTR>1H events (failures per reactor year) • Normally running TDP frequency of start demands • Normally running TDP frequency of run hours • Normally running TDP frequency of FTR events.

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor Operated Valves 1998–2022

This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following decreasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • Low-demand MOV frequency of FTOC events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of turbine driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10 year period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Motor Driven Pumps 1998–2022

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP frequency of start demands (demands per reactor year), (2) Standby MDP frequency of FTR=1H hours (hours per reactor year), (3) Standby MDP frequency of FTR>1H hours, and (4) Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP FTR=1H failure probability, (2) Normally running MDP FTR failure rate, (3) Standby MDP unavailability, (4) Standby MDP total unreliability (8-hour mission), and (5) Normally running MDP total unreliability (8-hour mission).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2018

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2018 as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The TDP failure modes considered are failure to start (FTS), failure to run less than or equal to one hour (FTR≤1H), failure to run more than one hour (FTR>1H), and normally running systems FTS and failure to run (FTR). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. A highly statistically significant decreasing trend was identified in the standby TDP unavailability estimates.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational Fluid Dynamics Analysis of a 12 MW Circulating Fluidized Bed Rise

A three-dimensional (3D) two fluid model (TFM) model of the 12 MW circulating fluidized bed (CFB) riser at Chalmers University was developed using the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The hydrodynamic behavior of the riser was validated by comparing axial pressure profiles from experimental measurements with the results from the simulations. Under some of the operating conditions where there was no external circulation of solids, the pressure profiles from the simulation matched well with the experimental measurements. For the cases where there was external circulation of solids, the pressure profiles with the monodisperse solid phase modeling underpredicted the solids concentration in the freeboard region. With the inclusion of polydispersity in the model, the predicted pressure profiles agreed well with the experimental measurements. A two-dimensional (2D) model of the riser was used to perform simulations of coal combustion. The predicted flue gas outlet compositions of oxygen and carbon dioxide compared reasonably to experiments. The experiments also reported some concentration of carbon monoxide which was overpredicted in the simulations. Additional experimental data such as axial oxygen concentration profile and pressure profiles were also compared with the experiment. It was observed that the oxygen concentration in the bottom bed from the simulations was higher than in the experiments, which suggested that most of the oxidation reactions occurred in the bottom bed. The concentration of volatiles and char in the simulations was lower in the bottom bed than in the experiments, which suggest that there is not sufficient penetration of the solid phase species into the bed.

20 FOSSIL-FUELED POWER PLANTS↗

Enhanced Component Performance Study: Air-Operated Valves 1998–2020

This report presents an enhanced performance evaluation of air-operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The AOV failure modes considered are failure-to-open/close (FTOC), failure to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following trends were identified for the most recent 10-year period: o Extremely statistically significant increasing trend for the frequency of FTOC demands (demands per reactor year) for low-demand (= 20 demands per year) AOVs o Extremely statistically significant increasing trend for the frequency of FTOC demands for high-demand (> 20 demands per year) AOVs o Highly statistically significant decreasing trend for the failure rate of FTOP for low-demand AOVs o Highly statistically significant decreasing trend for the frequency of FTOP events (failures per reactor year) for low-demand AOVs o Statistically significant decreasing trend for the failure rate of SO for low-demand AOVs o Statistically significant decreasing trend for the frequency of SO events (failures per reactor year) for low-demand AOVs.

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10-year period: The following decreasing trends were identified for TDPs for the most recent 10-year period: • Standby TDP FTR>1H failure rate • Standby TDP unavailability • Standby MDP total unreliability (8-hour mission) • Standby TDP frequency of FTR>1H events (failures per reactor year) • Normally running TDP frequency of start demands (demands per reactor year) • Normally running TDP frequency of run hours (hours per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP frequency of start demands (demands per reactor year) • Standby MDP frequency of FTR≤1H hours (hours per reactor year) • Standby MDP frequency of FTR>1H hours • Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP FTR≤1H failure probability • Normally running MDP FTR failure rate • Standby MDP unavailability • Normally running MDP total unreliability (8-hour mission) • Standby MDP frequency of FTR≤1H events (failures per reactor year) • Normally running MDP frequency of FTR events.

99 GENERAL AND MISCELLANEOUS↗