Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Anomaly Detection in Radiation Sensor Data with Applications to Transportation Security

In this paper, we present a new approach for detecting trucks transporting illicit radioactive materials using radiation data. The approach is motivated by the high number of false alarms that typically results when using radiation portal monitors. Our approach is a three-stage anomaly detection process that consists of transforming the radiation sensor data into wavelet coefficients, representing the transformed data in binary form, and detecting anomalies among data sets using a proximity-based method. The approach is evaluated using simulated radiation data, and the results are encouraging. From a transportation security perspective, our results indicate that the concomitant use of gross count and spectroscopy radiation data improves identification of trucks transporting illicit radioactive materials. The results also suggest that the use of additional heterogeneous data with radiation data may enhance the reliability of the detection process. Further testing with real radiation data and mixture of cargo is needed to fully validate the results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new algorithm for estimating radioxenon concentrations

A new algorithm (Xcounts) is introduced for estimating the activity concentrations of the xenon isotopes 131m Xe, 133m Xe, 133 Xe, and 135 Xe using beta-gamma coincidence data. The algorithm simultaneously estimates the decay counts associated with the four xenon isotopes, background, and radon in contrast to the net-counts method that uses sequential residual removal to account for background and interreferences. Calibration data for background counts are determined from gas-background measurements and simulation. In Xcounts, the false positive count rates for 131m Xe and 133m Xe are lower than the false positive rates for 133 Xe and 135 Xe. This algorithm appears to reliably detect the metastable isotopes at lower activity levels than the net-counts method and have similar performance for the other isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The coincidence counting technique for orders of magnitude background reduction in data obtained with the magnetic recoil spectrometer at OMEGA and the NIF

A magnetic recoil spectrometer (MRS) has been built and successfully used at OMEGA for measurements of down-scattered neutrons (DS-n), from which an areal density in both warm-capsule and cryogenic-DT implosions have been inferred. Another MRS is currently being commissioned on the National Ignition Facility (NIF) for diagnosing low-yield tritium-hydrogen-deuterium implosions and high-yield DT implosions. As CR-39 detectors are used in the MRS, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). The coincidence counting technique was developed to reduce these types of background tracks to the required level for the DS-n measurements at OMEGA and the NIF. Using this technique, it has been demonstrated that the number of background tracks is reduced by a couple of orders of magnitude, which exceeds the requirement for the DS-n measurements at both facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a four-element Si drift detector for X-ray absorption fine-structure spectroscopy: resolution, maximum count rate, and dead-time correction with incorporation into the ATHENA data analysis software

The performance of a four-element Si drift detector for energy-dispersive fluorescence-yield X-ray absorption fine-structure measurements is reported, operating at the National Institute of Standards and Technology beamline X23A2 at the National Synchrotron Light Source. The detector can acquire X-ray absorption fine-structure spectra with a throughput exceeding 4 x 10{sup 5} counts per second per detector element (>1.6 x 10{sup 6} total counts per second summed over all four channels). At this count rate the resolution at 6 keV is approximately 220 eV, which adequately resolves the Mn K{sub {alpha}} and K{sup {beta}} fluorescence lines. Accurate dead-time correction is demonstrated, and it has been incorporated into the ATHENA data analysis program. To maintain counting efficiency and high signal to background, it is suggested that the incoming count rate should not exceed {approx}70% of the maximum throughput.

42 ENGINEERING↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

Fast correlation function calculator: A high-performance pair-counting toolkit

A novel high-performance exact pair-counting toolkit called fast correlation function calculator (FCFC) is presented. With the rapid growth of modern cosmological datasets, the evaluation of correlation functions with observational and simulation catalogues has become a challenge. High-efficiency pair-counting codes are thus in great demand. We introduce different data structures and algorithms that can be used for pair-counting problems, and perform comprehensive benchmarks to identify the most efficient algorithms for real-world cosmological applications. We then describe the three levels of parallelisms used by FCFC, SIMD, OpenMP, and MPI, and run extensive tests to investigate the scalabilities. Finally, we compare the efficiency of FCFC with alternative pair-counting codes. The data structures and histogram update algorithms implemented in FCFC are shown to outperform alternative methods. FCFC does not benefit greatly from SIMD because the bottleneck of our histogram update algorithm is mainly cache latency. Nevertheless, the efficiency of FCFC scales well with the numbers of OpenMP threads and MPI processes, even though speedups may be degraded with over a few thousand threads in total. FCFC is found to be faster than most (if not all) other public pair-counting codes for modern cosmological pair-counting applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Combining biomarker and virus phylogenetic models improves HIV-1 epidemiological source identification

To identify and stop active HIV transmission chains new epidemiological techniques are needed. Here, we describe the development of a multi-biomarker augmentation to phylogenetic inference of the underlying transmission history in a local population. HIV biomarkers are measurable biological quantities that have some relationship to the amount of time someone has been infected with HIV. To train our model, we used five biomarkers based on real data from serological assays, HIV sequence data, and target cell counts in longitudinally followed, untreated patients with known infection times. The biomarkers were modeled with a mixed effects framework to allow for patient specific variation and general trends, and fit to patient data using Markov Chain Monte Carlo (MCMC) methods. Subsequently, the density of the unobserved infection time conditional on observed biomarkers were obtained by integrating out the random effects from the model fit. This probabilistic information about infection times was incorporated into the likelihood function for the transmission history and phylogenetic tree reconstruction, informed by the HIV sequence data. To critically test our methodology, we developed a coalescent-based simulation framework that generates phylogenies and biomarkers given a specific or general transmission history. Testing on many epidemiological scenarios showed that biomarker augmented phylogenetics can reach 90% accuracy under idealized situations. Under realistic within-host HIV-1 evolution, involving substantial within-host diversification and frequent transmission of multiple lineages, the average accuracy was at about 50% in transmission clusters involving 5–50 hosts. Realistic biomarker data added on average 16 percentage points over using the phylogeny alone. Using more biomarkers improved the performance. Shorter temporal spacing between transmission events and increased transmission heterogeneity reduced reconstruction accuracy, but larger clusters were not harder to get right. More sequence data per infected host also improved accuracy. We show that the method is robust to incomplete sampling and that adding biomarkers improves reconstructions of real HIV-1 transmission histories. The technology presented here could allow for better prevention programs by providing data for locally informed and tailored strategies.

60 APPLIED LIFE SCIENCES↗

235 U Determination using In-Beam Delayed Neutron Counting Technique at the NRU Reactor

This paper describes a collaborative effort that saw the Royal Military College of Canada (RMC)’s delayed neutron and gamma counting apparatus transported to Canadian Nuclear Laboratories (CNL) for use in the neutron beamline at the National Research Universal (NRU) reactor. Samples containing mg quantities of fissile material were re-interrogated, and their delayed neutron emissions measured. This collaboration offers significant advantages to previous delayed neutron research at both CNL and RMC. This paper details the determination of 235 U content in enriched uranium via the assay of in-beam delayed neutron magnitudes and temporal behavior. 235 U mass was determined with an average absolute error of ± 2.7 %. This error is lower than that obtained at RMCC for the assay of 235 U content in aqueous solutions (3.6 %) using delayed neutron counting. Delayed neutron counting has been demonstrated to be a rapid, accurate, and precise method for special nuclear material detection and identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lessons learned on the presentation of scan data

Technicians performed a radiological survey of a surplus metal tank to support disposition planning at an Oak Ridge, Tennessee site. The survey included radiation scans to identify contamination and, if identified, define the boundary and magnitude of contamination. Fixed-point 1-minute measurements were also collected at randomly selected locations for comparison against the site's free release limit of 5,000 disintegrations per minute per 100 cm² (dpm/100 cm²) (0.83 Bq/cm²). Scan data were recorded using a data logger as a means to document surveyor observation - logged data captured at 1-second intervals and converted to counts per minute (cpm) by the data logger software were presented in the project report. Both the qualitative scan data (in cpm) and the quantitative direct measurement (in dpm/100 cm²) were reported for completeness, so stakeholders had all available information to support disposition decisions. However, a new stakeholder - introduced to the project at the reporting phase of work - used the instrument efficiency and background data to convert the scan data from cpm to dpm/100 cm², then compared the converted results to the site limit. Many of the converted values exceeded 5,000 dpm/100 cm². This resulted in delays in tank disposition and additional project costs which could have been avoided if the proper use and interpretation of scan data, and implications of radon progeny buildup on oxidized metal surfaces, had been better communicated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Galaxy Count Correlation Function in Redshift Space Revisited

In the near future, cosmology will enter the wide and deep galaxy survey era, enabling high-precision studies of the large-scale structure of the universe in three dimensions. To test cosmological models and determine their parameters accurately, it is necessary to use data with exact theoretical expectations expressed in observational parameter space (angles and redshift). The data-driven, galaxy number count fluctuations on redshift shells can be used to build correlation functions ξ(θ,z{sub 1},z{sub 2}) on and between shells to probe the baryonic acoustic oscillations and distance-redshift distortions, as well as gravitational lensing and other relativistic effects. To obtain a numerical estimation of ξ(θ,z{sub 1},z{sub 2}) from a cosmological model, it is typical to use either a closed form derived from a tripolar spherical expansion or to compute the power spectrum C{sub ℓ}(z{sub 1},z{sub 2}) and perform a Legendre polynomial P{sub ℓ}(cos θ) expansion. Here, we present a new derivation of a ξ(θ,z{sub 1},z{sub 2}) closed form using the spherical harmonic expansion and proceeding to an infinite sum over multipoles thanks to an addition theorem. We demonstrate that this new expression is perfectly compatible with the existing closed forms but is simpler to establish and manipulate. We provide formulas for the leading density and redshift-space contributions, but also show how Doppler-like and lensing terms can be easily included in this formalism. We have implemented and made publicly available software for computing those correlations efficiently, without any Limber approximation, and validated this software with the CLASSgal code. It is available at https://gitlab.in2p3.fr/campagne/AngPow.

79 ASTRONOMY AND ASTROPHYSICS↗

LDRD final report : managing shared memory data distribution in hybrid HPC applications.

MPI is the dominant programming model for distributed memory parallel computers, and is often used as the intra-node programming model on multi-core compute nodes. However, application developers are increasingly turning to hybrid models that use threading within a node and MPI between nodes. In contrast to MPI, most current threaded models do not require application developers to deal explicitly with data locality. With increasing core counts and deeper NUMA hierarchies seen in the upcoming LANL/SNL 'Cielo' capability supercomputer, data distribution poses an upper boundary on intra-node scalability within threaded applications. Data locality therefore has to be identified at runtime using static memory allocation policies such as first-touch or next-touch, or specified by the application user at launch time. We evaluate several existing techniques for managing data distribution using micro-benchmarks on an AMD 'Magny-Cours' system with 24 cores among 4 NUMA domains and argue for the adoption of a dynamic runtime system implemented at the kernel level, employing a novel page table replication scheme to gather per-NUMA domain memory access traces.

99 GENERAL AND MISCELLANEOUS↗

Data acquisition system with pulse height capability for the TOFED time-of-flight neutron spectrometer

A new time-of-flight neutron spectrometer TOFED has been constructed for installation at Experimental Advanced Superconducting Tokamak. A data acquisition system combining measurements of flight time and energy from the interaction of neutrons with the TOFED scintillators has been developed. The data acquisition system can provide a digitizing resolution better than 1.5% (to be compared with the >10% resolution of the recoil particle energy in the plastic scintillators) and a time resolution <1 ns. At the same time, it is compatible with high count rate event recording, which is an essential feature to investigate phenomena occurring on time scales faster than the slowing down time (≈100 ms) of the beam ions in the plasma. Implications of these results on the TOFED capability to resolve fast ion signatures in the neutron spectrum from EAST plasmas are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Geant4’s G4NRF module against nuclear resonance fluorescence data from 238 U and 27 Al

G4NRF (Jordan and Warren, 2007; Vavrek et al., 2018a,b) is a simulation module for modeling nuclear resonance fluorescence (NRF) interactions in the Geant4 framework (Allison et al., 2016). In this work, we validate G4NRF against both absolute and relative measurements of three NRF interactions near 2.2 MeV in 238 U and 27 Al using the transmission NRF data from the experiments described in Jayson et al. (2018). Agreement between the absolute NRF count rates observed in the data and predicted by extensive Geant4+G4NRF modeling validate the combined Geant4+G4NRF to approximately 15–20% in the 238 U NRF transitions and 10% in 27 Al, for an average 14% discrepancy across the entire study. The difference between simulation and experiment in relative NRF rates, as expressed as ratios of count rates in various NRF lines, is found at the level of ≲3%, and is statistically identical to zero. Finally, inverting the analysis, approximate values of the absolute level widths and branching ratios for 238 U and 27 Al are also obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction of Mass Spectral Response Factors from Predicted Chemometric Data for Druglike Molecules

A method is developed for the prediction of mass spectral ion counts of drug-like molecules using in silico calculated chemometric data. Various chemometric data, including polar and molecular surface areas, aqueous solvation free energies, and gas-phase and aqueous proton affinities were computed, and a statistically significant relationship between measured mass spectral ion counts and the combination of aqueous proton affinity and total molecular surface area was identified. In particular, through multilinear regression of ion counts on predicted chemometric data, we find that log{sub 10}(MS ion counts) = –4.824 + c{sub 1}•PA + c{sub 2}•SA, where PA is the aqueous proton affinity of the molecule computed at the SMD(aq)/M06-L/MIDI!//M06-L/MIDI! level of electronic structure theory, SA is the total surface area of the molecule in its conjugate base form, and c{sub 1} and c{sub 2} have values of –3.912 × 10{sup –2} mol kcal{sup –1} and 3.682 × 10{sup –3} Å{sup –2}. On a 66-molecule training set, this regression exhibits a multiple R value of 0.791 with p values for the intercept, c{sub 1}, and c{sub 2} of 1.4 × 10{sup –3}, 4.3 × 10{sup –10}, and 2.5 × 10{sup –6}, respectively. Application of this regression to an 11-molecule test set provides a good correlation of prediction with experiment (R = 0.905) albeit with a systematic underestimation of about 0.2 log units. This method may prove useful for semiquantitative analysis of drug metabolites for which MS response factors or authentic standards are not readily available. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION↗

Recent Advances in Analytical Electron Microscopy for Irradiated Materials

Analytical electron microscopy (AEM) in the scanning transmission electron microscope (STEM) has long been a staple of post-irradiation examination (PIE) and materials development campaigns. Recently, new advances in both STEM hardware and post-processing data-analysis software, along with ancillary advances such as in focused ion beam (FIB) sample preparation, has led to exciting advances in the quantity and quality of data that can be obtained. This talk will summarize recent experiments performed at Oak Ridge National Laboratory (ORNL), especially work on neutron-irradiated materials and fuels taking advantage of a newly-installed latest-generation AEM tool in the ORNL irradiated materials laboratories. ORNL installed a new FEI Talos F200X microscope, a 200 keV, high-brightness Schottky emission AEM system optimized for high-speed, high-efficiency X-ray mapping experiments. The F200X features the FEI 'SuperX' four-sector silicon drift detector (SDD) X-ray detector, which provides 0.9 sr solid angle of collection. By combining the high-brightness electron source, latest-generation electron optics, and fast computers and pulse processors, X-ray mapping speed is increased by a factor of 50-100 x compared to the previous-generation instruments. In addition to improvements in hardware, data mining via multivariate statistical analysis (MVSA) allows for maximum insight to the data obtained from the new hardware. MVSA data mining of the X-ray maps allows, for instance, unbiased computational identification of the phases present, and discovery of small phases or precipitates not expected by the human analyst. This talk will present examples of experiments performed using the most modern AEM tools and software. Silicon carbide is a major candidate for next-generation nuclear applications. Nano-infiltration by transient eutectic (NITE) SiC requires low sintering temperatures. X-ray mapping of the NITE structure find pockets of different oxides, such as Zr-Y-oxide, Y-Al-oxide, and yttria. MVSA data mining finds the regions where different oxides are present and indicates that Y additions preferentially wet grain boundaries, where Zr additions are preferentially concentrated at grain triple points. SiC coatings from AGR-I experiment TRISO particles were found to contain significant quantities of fission products (e.g., Pd) as well as actinides (U, Pu). MVSA data mining found complex precipitates and grain boundary films of the fission products and actinides deep (∼several microns) into the SiC layer. Advanced AEM methods, combined with MVSA data mining, makes possible both rapid and detailed PIE. Ferritic alloys, such as accident-tolerant FeCrAl grades, benefit greatly from advanced AEM examination. Neutron-irradiated FeCrAl precipitates the detrimental Cr-rich α' phase. Because the SuperX SDD system has four detectors, it is possible to obtain high X-ray count rates even on a highly tilted specimen, as might be needed to obtain STEM images of dislocation loops. Results on neutron-irradiated FeCrAl indicates that α' size and number density can be obtained by AEM, and MVSA results determine that minor elements (such as Si) has complex radiation-induced segregation behavior at grain boundaries. We have also developed and validated computer models of the AEM experiment, allowing different microstructures' X-ray map results to be simulated for different STEM instruments. This allows X-ray mapping to be more quantitative, such as by estimating what size nanoclusters in an oxide-dispersion strengthened steel would be visible or invisible in STEM. In summary, new advanced AEM technology provides a major leap forward in experiments possible in PIE of irradiated materials. (authors)

36 MATERIALS SCIENCE↗

THE CHANDRA SURVEY OF THE COSMOS FIELD. II. SOURCE DETECTION AND PHOTOMETRY

The Chandra COSMOS Survey (C-COSMOS) is a large, 1.8 Ms, Chandra program that covers the central contiguous {approx}0.92 deg{sup 2} of the COSMOS field. C-COSMOS is the result of a complex tiling, with every position being observed in up to six overlapping pointings (four overlapping pointings in most of the central {approx}0.45 deg{sup 2} area with the best exposure, and two overlapping pointings in most of the surrounding area, covering an additional {approx}0.47 deg{sup 2}). Therefore, the full exploitation of the C-COSMOS data requires a dedicated and accurate analysis focused on three main issues: (1) maximizing the sensitivity when the point-spread function (PSF) changes strongly among different observations of the same source (from {approx}1 arcsec up to {approx}10 arcsec half-power radius); (2) resolving close pairs; and (3) obtaining the best source localization and count rate. We present here our treatment of four key analysis items: source detection, localization, photometry, and survey sensitivity. Our final procedure consists of a two step procedure: (1) a wavelet detection algorithm to find source candidates and (2) a maximum likelihood PSF fitting algorithm to evaluate the source count rates and the probability that each source candidate is a fluctuation of the background. We discuss the main characteristics of this procedure, which was the result of detailed comparisons between different detection algorithms and photometry tools, calibrated with extensive and dedicated simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗