Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Plug-and-Play Environmental Monitoring Spacecraft Subsystem

A Space Environment Monitor (SEM) subsystem architecture has been developed and demonstrated that can benefit future spacecraft by providing (1) real-time knowledge of the spacecraft state in terms of exposure to the environment; (2) critical, instantaneous information for anomaly resolution; and (3) invaluable environmental data for designing future missions. The SEM architecture consists of a network of plug-and- play (PnP) Sensor Interface Units (SIUs), each servicing one or more environmental sensors. The SEM architecture is influenced by the IEEE Smart Transducer Interface Bus standard (IEEE Std 1451) for its PnP functionality. A network of PnP Spacecraft SIUs is enabling technology for gathering continuous real-time information critical to validating spacecraft health in harsh space environments. The demonstrated system that provided a proof-of-concept of the SEM architecture consisted of three SIUs for measurement of total ionizing dose (TID) and single event upset (SEU) radiation effects, electromagnetic interference (EMI), and deep dielectric charging through use of a prototype Internal Electro-Static Discharge Monitor (IESDM). Each SIU consists of two stacked 2X2 in. (approximately 5X5 cm) circuit boards: a Bus Interface Unit (BIU) board that provides data conversion, processing and connection to the SEM power-and-data bus, and a Sensor Interface Electronics (SIE) board that provides sensor interface needs and data path connection to the BIU.

Patel, Jagdish↗

Miniature Variable Pressure Scanning Electron Microscope for In-Situ Imaging and Chemical Analysis

NASA Marshall Space Flight Center (MSFC) is leading an effort to develop a Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for in-situ imaging and chemical analysis of uncoated samples. This instrument development will be geared towards operation on Mars and builds on a previous MSFC design of a mini-SEM for the moon (funded through the NASA Planetary Instrument Definition and Development Program). Because Mars has a dramatically different environment than the moon, modifications to the MSFC lunar mini-SEM are necessary. Mainly, the higher atmospheric pressure calls for the use of an electron gun that can operate at High Vacuum, rather than Ultra-High Vacuum. The presence of a CO2-rich atmosphere also allows for the incorporation of a variable pressure system that enables the in-situ analysis of nonconductive geological specimens. Preliminary testing of Mars meteorites in a commercial Environmental SEM(Tradmark) (FEI) confirms the usefulness of lowcurrent/low-accelerating voltage imaging and highlights the advantages of using the Mars atmosphere for environmental imaging. The unique capabilities of the MVP-SEM make it an ideal tool for pursuing key scientific goals of NASA's Flagship Mission Max-C; to perform in-situ science and collect and cache samples in preparation for sample return from Mars.

Gaskin, Jessica A.↗

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

New Insights on Subsurface Imaging of Carbon Nanotubes in Polymer Composites via Scanning Electron Microscopy

Despite many studies of subsurface imaging of carbon nanotube (CNT)-polymer composites via scanning electron microscopy (SEM), significant controversy exists concerning the imaging depth and contrast mechanisms. We studied CNT-polyimide composites and, by threedimensional reconstructions of captured stereo-pair images, determined that the maximum SEM imaging depth was typically hundreds of nanometers. The contrast mechanisms were investigated over a broad range of beam accelerating voltages from 0.3 to 30 kV, and ascribed to modulation by embedded CNTs of the effective secondary electron (SE) emission yield at the polymer surface. This modulation of the SE yield is due to non-uniform surface potential distribution resulting from current flows due to leakage and electron beam induced current. The importance of an external electric field on SEM subsurface imaging was also demonstrated. The insights gained from this study can be generally applied to SEM nondestructive subsurface imaging of conducting nanostructures embedded in dielectric matrices such as graphene-polymer composites, silicon-based single electron transistors, high resolution SEM overlay metrology or e-beam lithography, and have significant implications in nanotechnology.

Zhao, Minhua↗

Characterization of Pu-238 Heat Source Granule Containment

The Milliwatt Radioisotopic Themoelectric Generator (RTG) provides power for permissive-action links. Essentially these are nuclear batteries that convert thermal energy to electrical energy using a doped silicon-germanium thermopile. The thermal energy is provided by a heat source made of 238 Pu, in the form of 238 PuO 2 granules. The granules are contained by 3 layers of encapsulation. A thin T-111 liner surrounds the 238 PuO 2 granules and protects the second layer (strength member) from exposure to the fuel granules. An outer layer of Hastalloy-C protects the T-111 from oxygen embrittlement. The T-111 strength member is considered the critical component in this 238 PuO 2 containment system. Any compromise in the strength member seen during destructive testing required by the RTG surveillance program is characterized. The T-111 strength member is characterized through Scanning Electron Microscopy (SEM), and Metallography. SEM is used in the Secondary Electron mode to reveal possible grain boundary deformation and/or cracking in the region of the strength member weld. Deformation and cracking uncovered by SEM are further characterized by Metallography. Metallography sections are mounted and polished, observed using optical microscopy, then documented in the form of microphotographs. SEM mat further be used to examine polished Metallography mounts to characterize elements using the SEM mode of Energy Dispersive X-ray spectroscopy (EDS).

07 ISOTOPE AND RADIATION SOURCES↗

Electricity Submetering on the Cheap: Stick-on Electricity Meters

We demonstrate a low-cost, 21 x 12 mm prototype Stick-on Electricity Meter (SEM) to replace traditional in-circuit-breaker-panel current and voltage sensors for building submetering. A SEM sensor is installed on the external face of a circuit breaker to generate voltage and current signals. This allows for the computation of real and apparent power as well as capturing harmonics created by non-linear loads. The prototype sensor is built using commercially available components, resulting in a production cost of under $10 per SEM. With no highvoltage install work requiring an electrician, home owners or other individuals can install the system in a few minutes with no safety implications. This leads to an installed system cost that is much lower than traditional submetering technology.. Measurement results from lab characterization as well as a real-world residential dwelling installation are presented, verifying the operation of our proposed SEM sensor. The SEM sensor can resolve breaker power levels below 10W, and it can be used to provide data for non-intrusive load monitoring systems at full sample rate.

Lanzisera, Steven↗

Advanced Characterization of Rare Earth Elements in Coal Utilization Byproducts

Rare earth elements (REE) in various forms (e.g., crystalline mineral phases; adsorbed/absorbed state on and into organic macerals, neoformed glass from flyash or bottom ash) from domestic feedstocks such as coal deposits to coal utilization byproducts (CUB) have the potential to reduce foreign REE dependence and increase domestic resource security. Characterization is critical for understanding environmental risks related to their fate and transport as well as determining the most practical and economical techniques for concentrating the REE and converting them into chemical stocks for manufacturing. Several complementary electron microscopy (SEM-EDS, EPMA-WDS, FIB-SEM, cathodoluminescence, and XRD) and post image processing techniques were used to understand REE transition from coal to CUB. Sites of interest were identified and imaged and respective elemental x-ray maps acquired and montaged. Pixel classification of SEM imagers was completed using image analysis techniques to quantify the distribution of REE associated features. Quantitative elemental analysis of phases were completed using EMPA-WDS followed by FIB-SEM. The FIB-SEM results were reconstructed into 3D volumes and features of interest (e.g. monazite) were analyzed to determine the structure and volumetric estimation of REEs and thus predict detrital REE phases to ICP-MS results. Trace minerals were identified as pyrite, zircon, REE-phosphates' (monazite, xenotime), and barite within the coal tailings. In CUB, amorphous aluminosilicates, iron oxide cenospheres, and calcium oxides were present; monazite appear to be unaltered and unaffected by the combustion process in these samples. Thermal decomposition may have occurred due to presence of detrital zircon and xenotime and subsequent thin Ca-oxide coating enriched in trace REEs.

Verba, Circe↗

Particle Size Analysis and Distribution

Scanning Electron Microscope (SEM) is a instrument used for examining samples at magnifications from 32 X to 500,000 X (for our instrument). The SEM is attached with an electron gun and is directed onto the sample. The sample then produces an image where it is read on the monitor. The electron gun is positioned at the top because it needs to shoot at the sample that is being tested. The electrons are then shot in a downward motion traveling through several lenses, such as the condenser lens for a more precise reading. Once the samples have been read by the instrument, it will show a picture that has a certain number of particles. Particle size distribution have many uses that are essential to life habits (health) or even conventional use for example construction. Here are just a few examples of how particle size analysis and distribution are being used even today. This Standard Reference Material (SRM) is primarily intended for use in the calibration of equipment used to measure particle size distributions (PSD) in the 9 μm to 30 μm range. A unit of SRM 1984 consists of a single bottle containing approximately 14 g of tungsten carbide/cobalt powder. Certified values: The PSD values at five mass percentiles were measured by scanning electron microscopy (SEM) and laser light scattering (LLS). The NIST certified PSD values by SEM are listed. These certified values were determined by the measurement of over 10 000 individual particles from three bottles. Comparing the certified NIST SRM 1984 tungsten carbide/cobalt powder with our results are almost identical. This is great because more accurate work can be done and proves that our laboratory is able to reproduce NIST results. In conclusion, the scanning electron microscope is used to capture the sampled element and display it to be counted. Without the use of particle distribution, it would be a difficult time to get necessities such as medicine, asthma pumps, constructing materials, or as simple as ink. Overall, our study is an experimental comparison of the techniques we have in house, which are LLS and SEM (combined with the NIH ImageJ software) using the NIST SRM-1984 as a common, well characterized sample so that we have an idea of how the results from the techniques compare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tracer-Guided Characterization of Dominant Pore Networks and Implications for Permeability and Wettability in Shale

Pore network characterization is an important aspect in unconventional reservoir evaluation. While application of the technique of scanning electron microscope (SEM) brings substantial advances in pore characterization in shale, understanding the connected pore network that dominates flow in shale samples is limited by using SEM alone because of small fields of view and lack of views of connectivity in 3D. In this research, a technique integrating tracer imbibition, micro-computed tomography (CT) imaging, and SEM imaging was developed to provide a solution for multiscale imaging in shale. Tracer imbibition indicates pore connectivity; micro-CT imaging after tracer imbibition thus provides an overview of the connected pore network at the millimeter scale. With guidance from micro-CT images after tracer imbibition, a more accurate and detailed characterization of pore systems and related mineralogy can be conducted using higher-resolution SEM. The method was applied to five samples from Wolfcamp and Eagle Ford Formations. Results reveal the effectiveness of the integrated method by showing different patterns of distribution of the dominant pore network and different controlling mineralogy. Dominant porosity, estimated from grayscale analyses, displays a good correlation with permeability. This result indicates that dominant porosity is more relevant to permeability than is total porosity. Results from imbibition tests are also compared with that from contact angle measurement, and important implications on wettability can be obtained. The integrated method thus has the capacity to link the dominant pore network and wettability with microscale to submicroscale mineralogy, which can help better understand the pore systems and fluid flow in shale. Plain Language Summary Pore network characterization and wettability are two important aspects in unconventional reservoir evaluation and are crucial to understanding the nature of shale oil or gas storage and production. Here, a new technique integrating tracer imbibition, micro-computed tomography imaging, and scanning electron microscope imaging was developed for a more representative and effective pore characterization in shale. This integrated technique can provide a direct visualization of the dominant pore network in a millimeter-scale sample and, at the same time, can provide a guided pore network characterization under nanoscale resolution. This method thus can generate results that are more representative and more accurate in a more efficient way compared with the traditional scanning electron microscope method. The new technique can also reveal the local wettability in microscale. High-resolution analysis on the tracer imbibition or fluid displacement and mineralogy can shed light on the local wettability and the controlling mineralogy in shale.

58 GEOSCIENCES↗

An Improved Microwave Semiempirical Model for the Dielectric Behavior of Moist Soils

Soil semiempirical dielectric models (SEMs) are powerful, and they are generally considered a useful hybrid of both empirical and physical models. In this work, the Wang-Schmugge dielectric model is improved to more accurately estimate the relative complex dielectric constants (CDCs) of moist soils. Instead of the Debye relaxation spectrum of liquid water located outside of the soil (i.e., free out-of-soil water) adopted in the Wang-Schmugge model, the Debye relaxation formula related to the free-water component inside the soil [i.e., free soil water (FSW)], which is correlated with the soil texture, is employed in the improved SEM. In addition, the effective conductivity loss term related to both soil texture and soil moisture is introduced to explain the ionic conductivity losses of FSW. Since the soil moisture influence is reduced at high frequencies, the effective conductivity loss term related to only the soil texture is also analyzed for 14-18 GHz. As in the Wang-Schmugge model, the relative CDC of bound soil water varies with the soil volumetric moisture content when the soil moisture is lower than the maximum bound water fraction in the new model, which takes a different approach than the Mironov mineralogy-based SEM. The proposed model obtains better fitting results than the three most widely employed SEMs. Lastly, the improved model exhibits a significantly improved accuracy with a higher correlation coefficient (R²), a closer 1:1 relationship, and a lower root-mean-square error, including in the L-band, and especially in the imaginary part of the L-band.

semiempirical dielectric model (SEM)↗

Exploring 3D leaf anatomical traits for C 4 photosynthesis: chloroplast and plasmodesmata pit field size in maize and sugarcane

Summary Volume and surface area of chloroplasts and surface area of plasmodesmata pit fields are presented for two C 4 species, maize and sugarcane, with respect to cell surface area and cell volume. Serial block face scanning electron microscopy (SBF‐SEM) and confocal laser scanning microscopy with the Airyscan system (LSM) were used. Chloroplast size estimates were much faster and easier using LSM than with SBF‐SEM; however, the results were more variable than SBF‐SEM. Mesophyll cells were lobed where chloroplasts were located, facilitating cell‐to‐cell connections while allowing for greater intercellular airspace exposure. Bundle sheath cells were cylindrical with chloroplasts arranged centrifugally. Chloroplasts occupied c. 30–50% of mesophyll cell volume, and 60–70% of bundle sheath cell volume. Roughly 2–3% of each cell surface area was covered by plasmodesmata pit fields for both bundle sheath and mesophyll cells. This work will aid future research to develop SBF‐SEM methodologies with the aim to better understand the effect of cell structure on C 4 photosynthesis.

3D leaf imaging↗

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Parameters for the Particle Size Distribution of TATB

Laser light scattering (LLS), manual counting of scanning electron microscopy (SEM) images, and reduction of SEM images using ImageJ (open source program) to determine Feret (caliper) diameters were applied to determine particle size distribution (PSD) of four preparations of 1,3,5‐triamino‐2,4,6‐trinitrobenzene (TATB) and yttria‐stabilized zirconia (YSZ), an SEM certified standard. Mie theory was used to reduce the LLS data. The spherical nature of the YSZ made it a good candidate for LLS. Variations in n , the refractive index, and iκ, the imaginary component, produced very little change in the PSD. However, changing the carrier liquid from H 2 O to a 40% aqueous sucrose solution, thereby changing the carrier refractive index, n 0 , substantially affected the PSD. The Mie complex refractive indices for the YSZ were n = 2.200, iκ = 0.100, with a 40% aqueous sucrose solution, n 0 = 1.400. The triclinic crystal structure of TATB made refractive index determinations more difficult, so a study was conducted varying Mie parameters and comparing them to the same data reduced using the Fraunhofer theory. Changing the n and κ parameters produced PSD with a small concentration of particles less than 1 µm in size or none in this range. SEM images, Feret data, manual counting, and Fraunhofer data reduction indicate particles less than 1 µm are probably < 5% in concentration. The final selection of Mie parameters for TATB was n = 2.283, iκ = 0.1, and suspension medium, n 0 = 1.330. Finally, computations, using density functional theory produced similar parameters.

Feret diameter↗

An Assessment of Radiologically Inserted Transoral and Transgastric Gastroduodenal Stents to Treat Malignant Gastric Outlet Obstruction

Introduction: Self-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our goal was to review the outcome of patients who underwent radiological SEMS insertion performed by a single consultant interventional radiologist. Methods: Patients were identified from a prospectively collected database held by one consultant radiologist. Data were retrieved from radiological reports, multidisciplinary team meetings, and the patients’ case notes. Univariate survival analysis was performed. Results: Between December 2000 and January 2011, 100 patients (63 males, 37 females) had 110 gastroduodenal stenting procedures. Median age was 73 (range 39–89) years. SEMS were inserted transorally (n = 66) or transgastrically (n = 44). Site of obstruction was the stomach (n = 37), duodenum (n = 50), gastric pull-up (n = 10), or gastroenterostomy (n = 13). Seven patients required biliary stents. Technical success was 86.4 %: 83.3 % for transoral insertion, 90.9 % for transgastric insertion. Eleven patients developed complications. Median GOO severity score: 1 pre-stenting, 2 post-stenting (p = 0.0001). Median survival was 54 (range 1–624) days. Post-stenting GOO severity score was predictive of survival (p = 0.0001). Conclusions: The technical success rate for insertion of palliative SEMS is high. Insertional technique can be tailored to the individual depending on the location of the tumor and whether it is possible to access the stomach percutaneously. Patients who have successful stenting and return to eating a soft/normal diet have a statistically significant increase in survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Expandable Biodegradable Stents Versus Self-Expandable Metallic Stents: A Comparison Study of Stent-Induced Tissue Hyperplasia in the Rat Urethra

Purpose: To compare the degrees of stent-induced tissue hyperplasia of balloon-expandable, biodegradable stents (BEBSs) with those of self-expandable metallic stents (SEMSs) in a rat urethral model. Materials and Methods: A total of 20 rats were randomized into two groups. The BEBS group (n = 10) received a poly-l-lactic acid (PLLA) biodegradable stent. The SEMS group (n = 10) received a nitinol bare stent. All rats were killed eight weeks after stent placement. The degree of stent-induced tissue hyperplasia was assessed by comparing the results of retrograde urethrography and histologic examination between the two groups. Results: Stent placement was technically successful in all rats. Two rats in the BEBS group were excluded due to procedure-related death. The mean luminal diameter of stented urethra on urethrograms was not significantly different at 4 and 8 weeks between the two groups. On histologic analysis, the percentage of granulation tissue area (p < 0.001) and the thickness of papillary projection (p < 0.001) were significantly higher in the BEBS group compared with the SEMS group. The inflammatory cell infiltration showed a clear tendency to significance (p = 0.050). There were no statistical differences in the number of epithelial layers and the thickness of submucosal fibrosis between the two groups. Conclusion: Formation of stent-induced tissue hyperplasia was significantly evident in the rat urethra with similar degrees between the BEBS and the SEMS. The BEBS was associated with a thicker papillary projection and larger granulation tissue area resulting from higher inflammation compared with the SEMS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formation of Al{sub 15}Mn{sub 3}Si{sub 2} Phase During Solidification of a Novel Al-12%Si-4%Cu-1.2%Mn Heat-Resistant Alloy and Its Thermal Stability

The formation of Al{sub 15}Mn{sub 3}Si{sub 2} phase in Al-12Si-4Cu-1.2Mn (wt.%) alloy during solidification was investigated by adopting CALPHAD method and microstructural observation by optical microscopy, SEM–EDS, TEM–EDS/SAD and XRD analysis; SEM fixed-point observation method was applied to evaluate its thermal stability. As-cast microstructural observation consistently demonstrates the solidification sequence of the studied alloy predicted by phase diagram calculation. Based on the phase diagram calculation, SEM–EDS, TEM–EDS/SAD and XRD analysis, as well as evidences on Al-Si-Mn-Fe compounds from the literature, the primary and eutectic Mn-rich phases with different morphologies in the studied alloy are identified to be Al{sub 15}Mn{sub 3}Si{sub 2} that has a body-centered cubic (BCC) structure with a lattice constant of a = 1.352 nm. SEM fixed-point observation and XRD analysis indicate that Al{sub 15}Mn{sub 3}Si{sub 2} phase has more excellent thermal stability at high temperature than that of CuAl{sub 2} phase and can serve as the major strengthening phase in heat-resistant aluminum alloy that has to face a high-temperature working environment. Results of tension test show that addition of Mn can improve the strength of Al-Si-Cu alloy, especially at elevated temperature.

36 MATERIALS SCIENCE↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗