Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Diaboloidal mirrors: algebraic solution and surface shape approximations

A new type of optical element that can focus a cylindrical wave to a point focus (or vice versa) is analytically described. Such waves are, for example, produced in a beamline where light is collimated in one direction and then doubly focused by a single optic. A classical example in X-ray optics is the collimated two-crystal monochromator, with toroidal mirror refocusing. The element here replaces the toroid, and in such a system provides completely aberration free, point-to-point imaging of rays from the on-axis source point. We present an analytic solution for the mirror shape in its laboratory coordinate system with zero slope at the centre, and approximate solutions, based on bending an oblique circular cone and a bent right circular cylinder, that may facilitate fabrication and metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency reproducibility of solid-state thorium-229 nuclear clocks

Solid-state thorium-229 ( 229 Th) nuclear clocks are set to provide new opportunities for precision metrology and fundamental physics. Taking advantage of inherent low sensitivity of a nuclear transition to its environment, orders of magnitude more emitters can be hosted in a solid-state crystal compared with current optical lattice atomic clocks. Furthermore, solid-state systems needing only simple thermal control are key to the development of field-deployable compact clocks. Here we explore and characterize the frequency reproducibility of the 229 Th:CaF 2 nuclear clock transition, a key performance metric for all clocks. We measure the transition linewidth and centre frequency as a function of the doping concentration, temperature and time. We report the concentration-dependent inhomogeneous linewidth of the nuclear transition, limited by the intrinsic host crystal properties. We determine an optimal working temperature for the 229 Th:CaF 2 nuclear clock at 196(5) K, at which the first-order thermal sensitivity vanishes. This would enable in situ temperature co-sensing using different quadrupole-split lines, reducing the temperature-induced systematic shift below the 10 −18 fractional frequency uncertainty level. At 195 K, the reproducibility of the nuclear transition frequency is 220 Hz (fractionally 1.1 × 10 −13 ) for two differently doped 229 Th:CaF 2 crystals over 7 months. Furthermore, these results form the foundation for understanding, controlling and harnessing the coherent nuclear excitation of 229 Th in solid-state hosts and for their applications in constraining temporal variations of fundamental constants.

Atomic and molecular physics↗

Establishing temperature from radiance of dynamically compressed metals

Precise temperature determination is a significant challenge in extreme environments of dynamic compression studies. How can radiance measurements taken in high-pressure shock experiments constrain temperature in a meaningful and physically consistent way? Experiments maintaining sample compression against a transparent window can be tailored to present a uniform measurement area with uncertain spectral emissivity. We compare several methods to analyze radiance collected at multiple wavelengths, applying statistical methods and physical principles to improve temperature inference. With proper radiance collection and analysis, dynamic temperature uncertainties become comparable to thermomechanical ambiguities of the emitting surface.

36 MATERIALS SCIENCE↗

Cross-Cutting Metrology Tools for In Operando Characterization of Carrier Dynamics in Photovoltaic Devices (Final Technical Report)

Understanding the nature of recombination and its dependence on defects and interfaces is essential for engineering materials and contacts for higher V oc and photovoltaic (PV) efficiency. Time-resolved photoluminescence (TRPL) has conventionally been used to evaluate recombination, but not all materials are strongly emissive or otherwise suitable. Time-resolved terahertz spectroscopy is a pump – probe method that presents valuable complementary information, wherein an optical pump pulse photoexcites carriers within the absorber and the transient photoconductivity is probed with a terahertz pulse. Until now, experimental constraints have prohibited the use of terahertz probes to interrogate full device stacks, and measurements were instead made on exfoliated films or films grown on unconventional substrates. However, interfaces are critical to the behavior of photoexcited carriers in solar cells, and the substrates themselves often influence the film growth and bulk properties. Therefore, it is important to probe the behavior of PV absorbers as close as possible to their normal operating conditions. Here we have developed cross-cutting metrology that enable in operando characterization of carrier dynamics and recombination mechanisms in working PV devices. Through a combination of complementary non-contact TRTS and TRPL experiments and modeling, we have obtained key parameters including photoexcited carrier bulk lifetime and interface and back surface recombination velocities with greater precision and accuracy than can be achieved with conventional TRPL alone. By varying pulsed photoexcitation conditions, the contributions of interface and bulk recombination mechanisms can be determined. We have developed and refined this characterization approach by investigating CdTe PVs, which is a well-established technology but with significant margin for further improvements in efficiency. Results were published in Journal of Applied Physics (DOI: 10.1063/5.0064730) and Proceedings of the IEEE PVSC (DOI: 10.1109/PVSC43889.2021.9518559). After validating the approach, we have applied it to correlate recombination rates to processing conditions and material properties, including composition and defects as well as interfaces and surface treatments. Such feedback can inform processing and design choices to enable higher PV efficiency, not only for CdTe, but also CdSe x Te 1-x , CIGS, perovskites, kesterites, and future technologies. A perspective on predicting solar cell performance from terahertz spectroscopy was published in Advanced Energy Materials (DOI: 10.1002/aenm.202102776). The cross-cutting metrology tools developed here will enable determination of the locus and mechanism of performance-limiting recombination in thin film PV devices. This feedback can guide the engineering of PV devices with higher V oc and efficiency, thereby leading to reductions in levelized cost of electricity to meet the SunShot 2030 target of $0.03/kWh for utility-scale PV. Lower costs will enable rapid expansion of renewable electricity generation that is nearly free of carbon emissions. Reducing carbon emissions of the electricity sector is one of the most important solutions to climate change. The project’s specific focus on CdTe PV can benefit First Solar, the US company that is the global leader in CdTe technology, through both technology and workforce development.

14 SOLAR ENERGY↗

Ptychographic X-ray speckle tracking with multi-layer Laue lens systems

The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilize their capability for imaging and probing biological cells, nano-devices and functional matter on the nanometre scale with chemical sensitivity. Hard X-rays are ideal for high-resolution imaging and spectroscopic applications owing to their short wavelength, high penetrating power and chemical sensitivity. The penetrating power that makes X-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques have enabled the fabrication of a series of highly focusing X-ray lenses, known as wedged multi-layer Laue lenses. Improvements to the lens design and fabrication technique demand an accurate, robust, in situ and at-wavelength characterization method. To this end, a modified form of the speckle tracking wavefront metrology method has been developed. The ptychographic X-ray speckle tracking method is capable of operating with highly divergent wavefields. A useful by-product of this method is that it also provides high-resolution and aberration-free projection images of extended specimens. Three separate experiments using this method are reported, where the ray path angles have been resolved to within 4 nrad with an imaging resolution of 45 nm (full period). This method does not require a high degree of coherence, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology.

36 MATERIALS SCIENCE↗

Two-frequency sub-Doppler spectroscopy of the caesium D{sub 1} line in various configurations of counterpropagating laser beams

Sub-Doppler resonances in caesium vapours are studied in a laser field produced by counterpropagating two-frequency light beams with mutually orthogonal linear polarisations. The beams are in resonance with optical transitions in the D{sub 1} line, the frequency difference of the field spectral components being equal to the hyperfine ground-state splitting in the Cs atom (∼9.2 GHz). It has already been shown that in this configuration, the hypercontrast effect can be observed for sub-Doppler resonances, which makes this configuration promising for the employment in new-generation miniature optical frequency standards. In the present work, two different two-frequency configurations are compared with each other and with the single-frequency configuration widely used in practice for observing saturated absorption resonances. The parameters of nonlinear resonances are measured at various temperatures of caesium vapours and at different optical field intensities. The results of the investigations performed make it possible to find an optimal two-frequency scheme for exciting nonlinear resonances and to estimate a potential of the scheme for its applications in quantum metrology. (laser spectroscopy of atoms)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin Squeezing by Rydberg Dressing in an Array of Atomic Ensembles

Here, we report on the creation of an array of spin-squeezed ensembles of cesium atoms via Rydberg dressing, a technique that offers optical control over local interactions between neutral atoms. We optimize the coherence of the interactions by a stroboscopic dressing sequence that suppresses super-Poissonian loss. We thereby prepare squeezed states of N = 200 atoms with a metrological squeezing parameter ξ 2 = 0.77⁢(9) quantifying the reduction in phase variance below the standard quantum limit. We realize metrological gain across three spatially separated ensembles in parallel, with the strength of squeezing controlled by the local intensity of the dressing light. Our method can be applied to enhance the precision of tests of fundamental physics based on arrays of atomic clocks and to enable quantum-enhanced imaging of electromagnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Universality of Dicke superradiance in arrays of quantum emitters

Abstract Dicke superradiance is an example of emergence of macroscopic quantum coherence via correlated dissipation. Starting from an initially incoherent state, a collection of excited atoms synchronizes as they decay, generating a macroscopic dipole moment and emitting a short and intense pulse of light. While well understood in cavities, superradiance remains an open problem in extended systems due to the exponential growth of complexity with atom number. Here we show that Dicke superradiance is a universal phenomenon in ordered arrays. We present a theoretical framework – which circumvents the exponential complexity of the problem – that allows us to predict the critical distance beyond which Dicke superradiance disappears. This critical distance is highly dependent on the dimensionality and atom number. Our predictions can be tested in state of the art experiments with arrays of neutral atoms, molecules, and solid-state emitters and pave the way towards understanding the role of many-body decay in quantum simulation, metrology, and lasing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Integrated frequency-modulated optical parametric oscillator

Optical frequency combs have revolutionized precision measurement, time-keeping, and molecular spectroscopy. A substantial effort has developed around "microcombs": integrating comb-generating technologies into compact, reliable photonic platforms. Current approaches for generating these microcombs involve either the electro-optic (EO) or Kerr mechanisms. Despite rapid progress, maintaining high efficiency and wide bandwidth remains challenging. Here, we introduce a new class of microcomb -- an integrated optical frequency comb generator that combines electro-optics and parametric amplification to yield a frequency-modulated optical parametric oscillator (FM-OPO). In stark contrast to EO and Kerr combs, the FM-OPO microcomb does not form pulses but maintains operational simplicity and highly efficient pump power utilization with an output resembling a frequency-modulated laser. We outline the working principles of FM-OPO and demonstrate them by fabricating the complete optical system in thin-film lithium niobate (LNOI). We measure pump to comb internal conversion efficiency exceeding 93% (34% out-coupled) over a nearly flat-top spectral distribution spanning approximately 1,000 modes (approximately 6 THz). Compared to an EO comb, the cavity dispersion rather than loss determines the FM-OPO bandwidth, enabling broadband combs with a smaller RF modulation power. The FM-OPO microcomb, with its robust operational dynamics, high efficiency, and large bandwidth, contributes a new approach to the field of microcombs and promises to herald an era of miniaturized precision measurement, and spectroscopy tools to accelerate advancements in metrology, spectroscopy, telecommunications, sensing, and computing.

42 ENGINEERING↗

Infrared photon-number-resolving imager using a Skipper-CCD

Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an imaging device in the infrared wavelength range able to arbitrarily reduce the readout noise. We built a Measured Exposure Skipper-CCD Sensor Instrument equipped with a thick back-illuminated sensor, with photon-number-resolving capability in a wide dynamic range, spatial resolution, high quantum efficiency in the near-infrared and ultra-low dark counts. This device allows us to image objects in a broad range of intensities within the same frame and, by reducing the readout noise to less than 0.2e$^-$, to distinguish even those shapes with less than two photons per pixel, unveiling what was previously hidden in the noise. These results pave the way for building high-standard infrared imagers based on Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reporter-Spin-Assisted T 1 Relaxometry

A single-spin quantum sensor can quantitatively detect and image fluctuating electromagnetic fields via their effect on the sensor spin’s relaxation time, thus revealing important information about the target solid-state or molecular structures. However, the sensitivity and spatial resolution of spin relaxometry are often limited by the distance between the sensor and target. Here, we propose an alternative approach that leverages an auxiliary reporter spin in conjunction with a single-spin sensor, a diamond nitrogen-vacancy (N-V) center. We show that this approach can realize a 100-fold measurement sensitivity improvement for realistic working conditions and we experimentally verify the proposed method using a single shallow N-V center. Our work opens up a broad path of inquiry into a range of possible spin systems that can serve as relaxation sensors without the need for optical initialization and readout capabilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Sub-Hertz resonance by weak measurement

Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus has potential in precision measurement applications. Although frequency measurements offer the hitherto highest precision due to the stable narrow atomic transitions, it remains a long-standing interest to develop new schemes to further escalate their performance. Here, we demonstrate a WM-enhanced correlation spectroscopy technique capable of narrowing the resonance linewidth down to 0.1 Hz in a room-temperature atomic vapour cell. The potential of this technique for precision measurement is demonstrated through weak magnetic-field sensing. By judiciously pre- and post-selecting frequency-modulated input and output optical states in a nearly orthogonal manner, a sensitivity of 7 fT Hz -1/2 at a low frequency near DC is achieved using only one laser beam with 15 µW of power. Additionally, our results extend the WM framework to a non-Hermitian Hamiltonian and shed new light on metrology and bio-magnetic field sensing.

Science & Technology - Other Topics↗

Continuous operation of a coherent 3,000-qubit system

Neutral atoms are a promising platform for quantum science, enabling advances in areas ranging from quantum simulations and computation to metrology, atomic clocks and quantum networking. Although atom losses typically limit these systems to a pulsed mode, continuous operation could substantially enhance cycle rates, remove bottlenecks in metrology and enable deep-circuit quantum evolution through quantum error correction. Here we demonstrate an experimental architecture for high-rate reloading and continuous operation of a large-scale atom-array system while realizing coherent storage and manipulation of quantum information. Our approach utilizes a series of two optical lattice conveyor belts to transport atom reservoirs into the science region, where atoms are repeatedly extracted into optical tweezers without affecting the coherence of qubits stored nearby. Using a reloading rate of 300,000 atoms in tweezers per second, we create over 30,000 initialized qubits per second, which we leverage to assemble and maintain an array of over 3,000 atoms for more than 2 hours. Furthermore, we demonstrate persistent refilling of the array with atomic qubits in either a spin-polarized or a coherent superposition state while preserving the quantum state of stored qubits. Our results pave the way for the realization of large-scale continuously operated atomic clocks, sensors and fault-tolerant quantum computers.

atomic and molecular physics↗

Data-driven modeling and control of an X-ray bimorph adaptive mirror

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Topography restoration in white-light interferometry using an instrument transfer function evaluated with binary pseudo-random arrays

Accurate knowledge of the instrument transfer function (ITF) is vital for topography measurements using white-light interferometry (WLI). To this end, we derive a complete set of analytical expressions for the power spectral density (PSD) of a discretely sampled binary pseudo-random array (BPRA) as a theoretical benchmark. We then determine the ITF by comparing this theoretical PSD with the measured PSD of the BPRA. For the Zygo ZeGage Pro HR with a objective, the determined ITF closely matches the nominal modulation transfer function (MTF). Accordingly, we integrate the nominal MTF into Fourier-domain restoration filters and apply them to practical WLI topography data, yielding restored topographies that show improved agreement with atomic force microscopy measurements. Overall, our integrated BPRA-based ITF measurement and filtering methodology offers a robust yet practical means of characterizing WLI performance and enhancing the accuracy of surface measurements.

Hirose, Shigenobu [Japan Agency for Marine Earth S↗

Machine-learning-based automatic small-angle measurement between planar surfaces in interferometer images: A 2D multilayer Laue lenses case

Here, we report a new machine-learning-based approach to automatically measure the small angle between multiple planar surfaces characterized by white light interferometers. By applying an unsupervised clustering algorithm, DBSCAN (Density-Based Spatial Clustering of Applications with Noise), the multiple surfaces in an interferometer image are automatically identified as distinct surfaces. The angles between every two surfaces are then calculated through the surface fitting. This method can be applied to multiple surfaces regardless of their shapes and locations and significantly simplifies the angle measurement procedure. Using the developed method, we have demonstrated a quick and precise angle measurement for the alignment of 2D Multilayer Laue Lenses (MLLs) for the development of high-resolution x-ray microscopy. This automatic, accurate, and robust small-angle measurement method is compatible with widely used white light interferometers and can be further applied to other metrology applications of interferometer results.

36 MATERIALS SCIENCE↗

Temperature-dependent x-ray fluorescent response from thermographic phosphors under x-ray excitation

Phosphor thermometry has been successfully applied within several challenging environments. Typically, the thermographic phosphors are excited by an ultraviolet light source, and the temperature-dependent spectral or temporal response is measured. However, this is challenging or impossible in optically thick environments. In addition, emission from other sources (e.g., a flame) may interfere with the optical phosphor emission. Furthermore, a temperature dependent x-ray excitation/emission could alleviate these issues as x-rays could penetrate obscurants with no interference from flame luminosity. In addition, x-ray emission could allow for thermometry within solids while simultaneously x-ray imaging the structural evolution. In this study, select thermographic phosphors were excited via x-ray radiation, and their x-ray emission characteristics were measured at various temperatures. Several of the phosphors showed varying levels of temperature dependence with the strongest sensitivity occurring for YAG:Dy and ZnGa 2 O 4 :Mn. This approach opens a path for less intrusive temperature measurements, particularly in optically opaque multiphase and solid phase combustion environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗