Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Athena-I CUBIT Journal Files

The Monte Carlo N-Particle (MCNP)1 transport code version 6 (also known as MCNP6) has the capability for tracking particles on unstructured mesh (UM) geometry models embedded into con structive solid geometry (CSG) cells. This feature has been developed for performing calculations of complex geometry models because manually creating CSG models is a time-consuming and error prone process as the complexities of geometries increase. The UM capability was originally designed to work with UM models created with the Abaqus software and ASCII input files that it generates. The MCNP code version 6.0 and later can process UM models formatted as Abaqus input files. Starting with version 6.3, MCNP can also process HDF5 mesh input files. External codes must be used to generate Abaqus input files for MCNP UM calculations. CUBIT, the Sandia National Laboratory automated mesh generation toolkit, can generate a UM model formatted as an Abaqus input file. However, the Abaqus input files exported from CUBIT cannot be used for MCNP simulations because it lacks the proper syntax. A Python script was developed to convert an Abaqus file created by CUBIT to an Abaqus file format that MCNP can process. Creating UM models for complex geometries is not an easy task. The process of creating UM models in CUBIT for MCNP simulations is detailed in. CUBIT provides several user interface options including a graphical user interface (GUI) and a command line interface. A GUI provides an easy way to use CUBIT without learning the CUBIT command syntax. When using CUBIT with either interface option, command lines are written into an ASCII file known as a journal file; this journal file can be edited and archived so that it can be played back in CUBIT to automatically generate a UM model. This report describes the CUBIT journal files of the UM models developed for Athena-I. The Athena platform, an energy-tuning assembly, was developed to spectrally shape the National Ignition Facility (NIF) deuterium-tritium fusion neutron source to a thermonuclear (fusion) plus prompt fission neutron spectrum with capability to act as a short-pulse neutron source. MCNP6 was used for the Athena experiment design analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Scattering in High Magnetic Fields: Community Recommendations to Seize the Moment for Scientific Breakthroughs

Oak Ridge National Laboratory (ORNL) operates the world’s two most powerful neutron sources: the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS). These form a national user facility that provides neutron scattering instruments to probe and image static and dynamic properties of materials down to the atomic scale. Because the neutron carries a magnetic moment and the energies and wavelengths of neutrons match energy and length scales associated with magnetic materials, these facilities provide unique sensitivity to magnetism.

36 MATERIALS SCIENCE↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Advanced Modeling and Simulation Methods for Evaluation of Thermal Neutron Scattering Materials

With the rise of interest in thermal neutron scattering data for advanced reactor, criticality safety, and shielding applications, new experimental data are required for evaluation of new materials or for re-evaluation (or validations) of previously evaluated materials. New experimental data are evaluated in a three-step process: (1) computing the phonon characteristics, (2) computing the dynamic structure factor (DSF) from the data, and (3) using the experimental setup to simulate the experimental data. All three steps have challenges, ranging from the need for a sufficiently general material simulation code—a processing code that can compute the corresponding DSF—to having a detailed layout of the instrument/beamline/facility where the data were measured. Whereas phonon characteristics of materials can be computed using various methods (molecular dynamics, density functional theory, etc.), a high-fidelity computation of the DSF and the simulation of the experiment based on the DSF is vital to the accuracy of the evaluation. The latter two steps can be achieved by using the two corresponding code systems developed by instrument scientists at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory: (1) OCLIMAX, a program that calculates the dynamic structure factor from DFT and MD simulation results, and (2) MCViNE, a Monte Carlo neutron ray-tracing program designed to simulate neutron scattering experiments. Recently, polyethylene and yttrium hydride were measured at the Wide Angular-Range Chopper (ARCS) and SEQUOIA instrument stations of the SNS. These experiments are simulated using the density functional theory code, the Cambridge Serial Total Energy Package (CASTEP), to compute its phonon characteristics (eigenvalues/vectors and PDOS), which is then processed using OCLIMAX to yield the DSF, and finally the data at each instrument station are simulated by the MCViNE for comparison to the measured data for evaluation. For comparison to conventional evaluation methods, the scattering data processed from OCLIMAX are compared against those processed from the LEAPR module of NJOY, and the results from MCViNE simulations are compared against previously used simplified beamline models implemented in the Monte Carlo N-Particle (MCNP) code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three scintillators and a hydrogen-based EJ-309 scintillator to evaluate the effects of boron loading in comparison with a common commercially-available scintillator and feasibility for future neutron spectroscopy measurements. Finally, the detection of shielded neutron sources was explored to capitalize on the 10B thermal neutron capture reaction. The results showed loading the scintillators with boron deteriorated the PSD performance slightly compared to the unloaded deuterated scintillator and resulted in a relative light yield loss of 26% and 41% for the 10B enriched and natural boron BLDLS, respectively. Lastly, the BLDLS have a higher relative detection efficiency than the unloaded deuterated scintillator for shielded neutron sources, based on total count rate, a desirable characteristic for missions related to finding and characterizing illicitly-trafficked special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Reversible CO 2 Hydrogenation, Neutron Crystallography, and Hydride Reactivity of a Triiridium Heptahydride Complex

Abstract The authors report the structure, reactivity, and catalytic utility of a triiridium complex, [Ir 3 H 6 ( μ 3 ‐H)(PN) 3 ] 2+ ( 2‐H , PN = (2‐pyridyl)CH 2 PBu t 2 ). Despite its unusual stability to unsaturated organics, electrophiles, and even CF 3 SO 3 D, they find that complex 2‐H catalyzes hydrogenation of CO 2 to formate (TON Ir = 9600) and reverse formic acid dehydrogenation (TON Ir = 54 400). The hydrogenation operates via a reactive intermediate [Ir 3 H 4 ( μ ‐H) 4 (PN) 3 ] + ( 5 ). Neutron crystallography and DFT‐supported neutron vibrational spectroscopy of 2‐H reveal Ir─H bond lengths and elucidate the vibration modes within the Ir 3 H 7 core. Stoichiometric oxidation of 2‐H produces four classes of iridium complexes of varied nuclearity and hydride structure: tetra‐ and pentanuclear clusters [Ir 3 H 6 ( μ 3 ‐AuPPh 3 )(PN) 3 ] 2+ ( 2‐Au ) and [Ag{Ir 2 H 4 ( μ ‐OAc)(PN) 2 } 2 ] 3+ ( 6 ) are generated using AuPPh 3 + and AgOAc, respectively. Further oxidation to class [Ir 2 H 3 ( μ ‐X) 2 (PN) 2 ] + is possible with AgOAc, Hg(OAc) 2 , or I 2 . Finally, a TEMPO/HCl system completely oxidizes the hydrides and gives [Ir 2 Cl 4 ( μ ‐Cl) 2 (PN) 2 ] ( 11 ).

Cherepakhin, Valeriy [Loker Hydrocarbon Research I↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Soft Matter Sample Environments for Time-Resolved Small Angle Neutron Scattering Experiments: A Review

With the promise of new, more powerful neutron sources in the future, the possibilities for time-resolved neutron scattering experiments will improve and are bound to gain in interest. While there is already a large body of work on the accurate control of temperature, pressure, and magnetic fields for static experiments, this field is less well developed for time-resolved experiments on soft condensed matter and biomaterials. We present here an overview of different sample environments and technique combinations that have been developed so far and which might inspire further developments so that one can take full advantage of both the existing facilities as well as the possibilities that future high intensity neutron sources will offer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of the cryogenic moderator system for the second target station

The Second Target Station (STS) at Oak Ridge National Laboratory will be a 700 kW pulsed spallation neutron source designed to provide the world's highest brightness cold neutron beams. In order to produce the required neutron performance, two compact liquid hydrogen moderators are located adjacent to the tungsten spallation target and must be supplied with less than 20 K hydrogen and a para hydrogen fraction of 99.8% or greater. The Cryogenic Moderator System (CMS) will consist of a single hydrogen loop feeding the two moderators in series cooled by a helium refrigerator with a cooling capacity of 2.5 kW at 17 K. The hydrogen loop consists of a hydrogen circulator, hydrogen helium heat exchanger, ortho-para converter, accumulator, transfer lines and heater. The design of the hydrogen loop is based on the CMS design of the First Target Station at the Spallation Neutron Source and some of the component designs may be reused. General hydrogen temperature control is provided by controlling the flowrate of helium to the heat exchanger. The hydrogen loop will have a constant flowrate of 0.5 L/s and remove a nuclear heat load of about 850 W from the two moderators, which is deposited both directly in the hydrogen and the adjacent hydrogen containing structures. Because the nuclear heat load is accelerator driven, the hydrogen system must remain stable when the heat load is removed instantaneously during beam trips. System stability is maintained passively with the accumulator and actively with the heater. Ionizing radiation which interacts with the liquid hydrogen drives backconversion of the hydrogen from parahydrogen to orthohydrogen. The STS moderator performance is very sensitive to small fractions of orthohydrogen requiring an ortho-para converter to maintain the hydrogen supplied to the moderators at near equilibrium parahydrogen concentration. STS CMS is in the early stage of preliminary design and current focus is evaluating component sizing and system stability during beam transients.

Janney, Jim↗

HighNESS conceptual design report: Volume I

The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world’s most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron source located below the spallation target. Compared to the first source, designed for high cold and thermal brightness, the new source has been optimized to deliver higher intensity, and a shift to longer wavelengths in the spectral regions of cold (CN, 2–20 Å), very cold (VCN, 10–120 Å), and ultracold (UCN, >500 Å) neutrons. The second source comprises a large liquid deuterium moderator designed to produce CN and support secondary VCN and UCN sources. Various options have been explored in the proposed designs, aiming for world-leading performance in neutronics. These designs will enable the development of several new instrument concepts and facilitate the implementation of a high-sensitivity neutron-antineutron oscillation experiment (NNBAR). This document serves as the Conceptual Design Report for the HighNESS project, representing its final deliverable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Particulate Effluent Characterization (Final Report)

Understanding particulate emissions from nuclear facilities could help differentiate between normal nuclear operations and potential nuclear accidents or nuclear weapons tests. Oak Ridge National Laboratory (ORNL) is unique in that there are several types of nuclear facilities on site: an operating production reactor, radiochemical separation facilities, and a spallation neutron source. This project deployed a high-volume particulate air filter sampler to collect airborne particulate effluent from the nuclear facilities on site at ORNL. Collections occurred regularly from November 1, 2024, through June 30, 2025, and were analyzed via gamma spectroscopy in the laboratory. The radioisotope iodine-123 ( 123 I) was detected in several samples throughout the collection period. Detailed atmospheric transport modeling was performed on all detections for source attribution, and the most likely source of the 123 I was determined to be the Spallation Neutron Source. The project demonstrated the viability of ORNL as a test bed for effluent monitoring studies.

54 ENVIRONMENTAL SCIENCES↗

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code↗

Neutron Total Scattering Analysis of Materials for the Nuclear Fuel Cycle

Here, this paper reviews recent experimental efforts at the University of Tennessee and Oak Ridge National Laboratory to comprehensively characterize the structural details of materials relevant for the nuclear fuel cycle by employing advanced neutron scattering techniques. For the study of nuclear ceramics, neutron scattering offers distinct advantages over traditional laboratory or synchrotron X-ray diffraction, including enhanced sensitivity to elements with a low atomic mass, such as oxygen, nitrogen, and carbon. The key to these efforts is the recent advancement in the neutron scattering infrastructure at the high-flux diffractometers at the Spallation Neutron Source. The high neutron flux at these instruments enables neutron total scattering, a nondestructive bulk technique that simultaneously captures both short-range structural effects through pair distribution function analysis and long-range order through diffraction pattern analysis. This approach is particularly important for a comprehensive description of defective, disordered, or amorphous nuclear materials. The case studies presented here include analyses of the local defect structure in hyperstoichiometric uranium oxides and short-range order of ion-irradiated ceramics. This advanced analytical methodology will improve our understanding of the behavior of materials in extreme environments and contribute to the development of more resilient nuclear materials.

Neutron scattering↗

Mixed-Material Scintillators (MMSS Quarterly Report FY20Q2)

This project aims to invent, model, and prototype mixed-material scintillator systems (MMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (3D printing) of scintillator, a currently emerging application of additive manufacture technology. MMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising MMSS designs, this project will enable a new class of detectors to meet DNN’s mission needs for SNM detection. This quarter, we delivered one the MMSS Particle-ID Modeling report, a major deliverable of this project. This report describes our results on simulations of the particle-ID (PID) class of detectors. We found that these detectors outperform competing approaches for neutron-gamma discrimination, neutron source pointing, and neutron spectroscopy. Further highlights of the report are described below. During this quarter, We alerted HQ to a change in schedule for the remaining simulations planned for this project: we plan to put off further simulation and reporting of the position-resolving (PR) detector class until July. This change in schedule has allowed us to go into additional detail in the PID work that is both very promising and motivates our upcoming proposal. The other active task in this project is prototyping 3D-printed scintillators with the aim of realizing the designs we’ve simulated. On that front, we had three focuses: measuring the light output, increasing the size of printed parts, and combining blue and green scintillators. We succeeded in measuring the light output, showing an output of 30% of commercial standard. This result leaves room for improvement but is within striking distance of where we need to be. We were on track to demonstrate a key requirement for increasing the size of parts and also to show combined green/blue prints before the laboratory moved to a Minimum Safe (MinSafe) Operations posture as a result of local Shelter In Place orders due to Covid-19.

42 ENGINEERING↗

Impact of Irradiation and Decay Time on Chemical Speciation in Uranyl Sulfate Solution

A pH-1, 200-g U/L, highly enriched uranyl sulfate solution was neutron-irradiated using an accelerator-driven neutron source (the Universal Neutron Irradiator, UNI) to fission U-235 under conditions similar to those used by SHINE to produce Mo-99 in a subcritical assembly. We completed a series of five uranyl sulfate irradiations to assess the impact of irradiation and decay time on uranium precipitation and iodine speciation in solution. The duration of each irradiation was increased in order, with the shortest irradiation taking 2.9 hours and the longest, 64.5 hours. A total of 9.5E16 U-235 nuclei were fissioned in all irradiations, and a maximum fission power density of 0.26 W/mL was reached in the final irradiation. We observed no evidence of uranyl peroxide or other precipitates, demonstrating that the addition of Fe 2+ to a final Fe concentration of 200 ppm in the target solution was successful at preventing precipitation under representative irradiation conditions. Nonvolatile I - was found to be the dominant (>70%) iodine species in solution, both immediately after irradiation and after days to weeks of decay time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗