Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltammetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Label-Free Detection of Cardiac Troponin-I Using Carbon Nanofiber Based Nanoelectrode Arrays

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. A carbon nanofiber (CNF) multiplexed array has been fabricated with 9 sensing pads, each containing 40,000 carbon nanofibers as nanoelectrodes. Here, we report the use of vertically aligned CNF nanoelectrodes for the detection of cardiac Troponin-I for the early diagnosis of myocardial infarction. Antibody, antitroponin, probe immobilization and subsequent binding to human cardiac troponin-I were characterized using electrochemical impedance spectroscopy and cyclic voltammetry techniques. Each step of the modification process resulted in changes in electrical capacitance or resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific antigen. This sensor demonstrates high sensitivity, down to 0.2 ng/mL, and good selectivity making this platform a good candidate for early stage diagnosis of myocardial infarction.

cardiac output↗

Study of Stable Cathodes and Electrolytes for High Specific Density Lithium-Air Battery

Future NASA missions require high specific energy battery technologies, greater than 400 Wh/kg. Current NASA missions are using "state-of-the-art" (SOA) Li-ion batteries (LIB), which consist of a metal oxide cathode, a graphite anode and an organic electrolyte. NASA Glenn Research Center is currently studying the physical and electrochemical properties of the anode-electrolyte interface for ionic liquid based Li-air batteries. The voltage-time profiles for Pyr13FSI and Pyr14TFSI ionic liquids electrolytes studies on symmetric cells show low over-potentials and no dendritic lithium morphology. Cyclic voltammetry measurements indicate that these ionic liquids have a wide electrochemical window. As a continuation of this work, sp2 carbon cathode and these low flammability electrolytes were paired and the physical and electrochemical properties were studied in a Li-air battery system under an oxygen environment.

cathodes↗

Carbon Nanostructures in Biological Sensors for Space and Terrestrial Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

Carbon Nanomaterials for Biosensing Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

Printed Electrochemical Sensor for Quantifying Bone Density Loss in Microgravity

Printed electrochemical biosensors have been developed for astronaut point-of-care testing. Our fabrication approach is complimentary with in-space manufacturing for an on-demand and hands-free fabrication process. These sensors are developed using a combination of thin film materials printing and 3D printing and are comprised of carbon nanotube, gold nanoparticle, silver nanoparticle and dielectric inks to make traditional electrochemical sensor devices. Initial prototyped printed electrochemical sensors demonstrate good electrochemical performance while also displaying low batch to batch variability. Here we report the development of a printed sensor to monitor bone turnover. The absence of load bearing forces experienced in microgravity causes a reduction of overall bone mass and results in the development of space osteopenia/osteoporosis.(1,2) Our approach to identify space osteopenia/osteoporosis is to monitor the change in bone mass indirectly through an excreted biomarker of bone remodeling, amino-terminal collagen crosslinks (NTX). Antibodies specific to NTX are added to the sensor’s electrode ink and applied during the manufacturing process. NTX is measured from a urine sample by changes in voltammetry and electrochemical impedance as it binds to the antibody modified electrode surface. The measurement is rapid, quantitative and requires only small handheld electronics to perform the measurement. By this process, ground and flight physicians will receive frequent and real-time insight into the development of space osteopenia/osteoporosis to guide appropriate countermeasures. REFERENCES [1] Nabavi, N. et al (2011) Bone 49, 965-974. [2] Tamma, R. et al (2009) FASEB J 23, 2549-2554.

in-space manufacturing↗

Electrochemical Life Detection Methods for Ocean World Exploration

Ubiquitous across terrestrial life is cellular machinery that allows chemical energy flow by facilitating and regulating electron-transfer and chemical modification pathways. Key classes of energy transport molecules enable this movement of electrons for a variety of biological purposes. Additionally, biological enzymes function to add or remove functional groups such asphosphate moieties to redox biomolecules. Presumably, extraterrestrial life is likely to rely on similar energy transport mechanisms. With the search for life in our solar system focused on the icy satellites of Jupiter and Saturn, Europa and Enceladus, developing instrumentation capable of measuring electrochemical redox signatures representative of biomolecules or enzymatic activity in seawater appears a promising and novel means of life detection. Here, we report our adaptation of the Mars Phoenix Wet Chemistry Laboratory (WCL) electroanalytical voltammetry capabilities to assay life-critical redox molecules in synthetic seawater representative of a saline alkaline solution similar to what has been predicted from the Cassini mission data of Enceladus’ sub-surface ocean. In addition, we employ a well-established electrochemical assay that indicates phosphatase activity by comparing substrate and product redox signatures. Our study demonstrated a 10 nM limit of detection for biological redox molecules and a 3 aM limit of detection for alkaline phosphatase in seawater. Incorporation of these methods into next generation WCL payloads aimed at ocean world life detection will enable the search for biological redox-active species and enzymatic activity as indicators of life.

planetary instruments↗

Design Optimization of Energized Composite Using Simulation and Experimental Methods

As electric vehicles (EVs) are evolving, innovative technologies like “energized composite” that can store energy in the car's body helps extend its range per charge. The composite's unique ability to function as both structural body panel and charge storage medium stems from its unique pattern design between “electrochemical areas (EcA)” and “epoxy area (EpA)”. Herein, a design optimization study is presented to obtain a balanced ratio between EcA versus EpA to maximize the charge storage ability of the composite while maintaining a decent tensile and bending strength. Simulations using ANSYS software and experimental confirmation using universal testing machines and electrochemical analyzers are used to derive optimum ratios between EcA and EpA. Uniaxial tension test and 3-point bend test have been performed to optimize the tensile and bend strengths, whereas cyclic voltammetry, galvanic charge–discharge, and electrochemical impedance spectroscopy are used to determine the electrochemical performance of various design configurations by modulating the ratios of EcA versus EpA. Overall, the highest achieved energy storage per lamina is 2531 mWh m−2 for a maximum of 81.6% EcA with a tensile strength of 417.73 MPa and bending strength of 263.13 MPa. This study is highly beneficial for EVs and aerospace applications.

energy storage↗

In situ Monitoring of Lanthanide Reactions with Oxide Species via Combined Absorption Spectroscopy and Electrochemical Methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

absorption spectroscopy↗

In situ monitoring of lanthanide reactions with oxide species via combined absorption spectroscopy and electrochemical methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with cyclic voltammetry (CV). Reaction rates and extent of Pr3+ removal from solution as monitored by CV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Boron‐Doped Nano‐Crystalline Coated Carbon Fibers for Phasic Dopamine Sensing

Real time, chronic electrochemical detection of neurotransmitters will provide a positive step in the treatment and understanding of neurological disease. However, current electrodes using carbon fibers (CF) fail to perform chronically. While diamond-based coatings show promise in improving their longevity, achieving a uniform layer of such coatings on CFs is challenging, and the electrodes often lose sensitivity after coating. In this work, a complete and uniform boron-doped nanocrystalline material grown in a diamond reactor (B-NCD) was developed to coat CF microelectrodes for neurochemical sensing. The coating was characterized electrically, optically, mechanically, and chemically. The B-NCD coated CF electrodes were able to detect phasic dopamine at a sensitivity comparable to the most widely used alternatives (uncoated and PEDOT:Nafion coated CFs). During biofouling testing, the B-NCD coated CF electrodes demonstrated better stability than uncoated CFs and comparable performance to PEDOT:Nafion coated CFs. Moreover, B-NCD exhibited no signs of degradation during consecutive FSCV applications, while uncoated and PEDOT:Nafion coated CF electrodes degraded significantly over time. Furthermore, the B-NCD coating supported the survival and development of neurons and astrocytes in vitro, exhibited excellent adhesion and durability during mechanical bending testing, and enabled successful in vivo recording of phasic dopamine release in the rat brain. Overall, B-NCD coated CFs present as an ideal candidate for chronic, flexible neural implantable electrodes for long-term neurochemical monitoring.

carbon fiber↗

In Situ Electrochemistry of Buried Interfaces in Metal Halide Perovskites: Probing Energy Bands, Halide Redox Activity, and Kinetics

Control over charge injection and extraction processes across buried interfaces is fundamental for all (opto)electronic multilayer device platforms, necessitating detailed understanding of local structural and chemical differences that promote defect formation, distort energetic band-edge alignments, and alter charge transport processes. Herein, the implementation of a low-cost electroanalytical methodologies’ tool suite is described to quantitatively characterize buried interfaces and redox reactions in printable, mixed electrical–ionic, and redox-active metal halide perovskites and a prototypical hole-transporting nickel oxide (NiO x ) thin film. The objective is to demonstrate the power of electrochemical methodologies to improve the nanoscale understanding of complex interfaces within optoelectronic devices by providing case studies on how to: i) differentiate between electronic and chemical properties in NiO x contacts; ii) measure changes in reversibility of halide redox reactions via NiO x surface states; iii) assess energy alignment and charge transport across (modified) buried interfaces; and iv) quantify defects at buried interfaces that change with modifiers and differences in perovskite processing, including increasing defect concentrations when films are slot-die-coated versus spin-cast. The collective approach addresses major challenges in understanding the precise energy landscape and interface reactivity under relevant electric fields that mimic operando conditions (away from equilibrium) and across length scales in thin film device formats.

(spectro)electrochemistry↗

Kinetic Investigation by Batch Processing of Film Growth during the Electrodeposition of Titanium from Ethaline

Titanium electrodeposition as a technological advance has been out of reach due to the poor film quality obtained when using previously developed methods. This study shows that the electrodeposition of Ti is possible and feasible from the deep eutectic solvent ethaline. Moreover, this study shows through batch analysis that this deposition has temperature-dependent aspects that alter the film deposition kinetics upon modest heating. This ultraviolet–visible spectroscopic study is highlighting the more facile reduction of Ti 4+ to Ti 3+ and then to Ti 2+ at elevated temperatures. Understanding the underlying kinetics of electrodeposition opens up new venues for the application of this important metal.

36 MATERIALS SCIENCE↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High-throughput measurements of CO 2 permeance and solubility in ionic liquid reveal a synergistic role of ionic interactions and void fractions

The factors that govern CO 2 solubility in ionic liquids (ILs) are of great interest for the development of new materials for CO 2 capture and utilization. The cationic functional group (i.e., imidazolium, pyrrolidinium, pyridinium, etc.), alkyl chain length of cation, degree of fluorination of anion, anion size, and the void fraction in IL are known to influence CO 2 solubility. However, a comprehensive explanation of how these factors collectively affect CO 2 solubility has not been developed yet. This knowledge gap is largely attributed to the lack of CO 2 solubility data for IL structures other than imidazolium based ILs. We report here an automated high-throughput (HT) setup for the measurement of CO 2 solubility in room-temperature ILs (RTILs) combining six different anions and nine different cations for a total of 19 different specific ranges of RTILs. The HT setup first dispenses up to 200 µL of RTILs in a 96-well microtiter plate and then utilizes a robotic arm to measure cyclic voltammogram (CV) in each well using maneuverable Ag electrodes. The Cottrell analysis of the CO 2 reduction CV peak provides a direct measurement of CO 2 permeance in RTILs, which yields Henry’s constant from the estimated diffusion coefficient of CO 2 . Henry’s constants thus obtained are in very good agreement with those reported earlier. The measured CO 2 permeance and Henry’s constant of all RTILs seem to follow a first-order dependence on void fraction and a second-order dependence on electrostatic interaction between anion and cation of IL, with some synergistic dependence on the product of a void fraction and electrostatic interaction, making them two important descriptors for the design of novel ILs.

CO2 Solubility↗

Mitigation of polysulfide shuttle effect in Li-S batteries through catalytic disproportionation reaction

Polysulfides are poorly retained within porous cathodes and readily diffuse into the electrolyte over time, leading to the well-known shuttle effect that undermines the reversibility of Li-S batteries. Here, in this study, we demonstrate that catalytic disproportionation of polysulfides provides an effective pathway to suppress this process by rapidly converting dissolved species into solid sulfur and sulfides, thereby preventing their migration into the electrolyte. Fundamentally, the sluggish kinetics of sulfur redox reactions are responsible for the accumulation and redistribution of soluble polysulfides in the bulk electrolyte. By accelerating these kinetics, catalyzed disproportionation not only confines sulfur within the conductive cathode matrix but also promotes the homogeneous precipitation of Li₂S₂/Li₂S, which enhances electrochemical reversibility and cycling stability. Using nitrogen-doped carbon (NC800) as a model catalyst, we reveal its ability to drive a pseudo-16-electron reduction pathway, leading to a single dominant Li₂S product and uniform deposition within the porous framework. In contrast, a non-catalytic carbon (KB) yields multiple polysulfide intermediates and heterogeneous deposition. The mechanistic insights provided here highlight the pivotal role of catalytic disproportionation in reshaping sulfur redox pathways and offer a rational strategy for mitigating polysulfide shuttling in practical Li-S pouch cells.

25 ENERGY STORAGE↗

Uncovering Backbone Conformation for Rigid DPP-Based Donor–Acceptor Conjugated Polymer Using Deuterium Labeling and Neutron Scattering

The conjugated polymer’s backbone conformation dictates the delocalization of electrons, ultimately affecting its optoelectronic properties. Most conjugated polymers can be viewed as semirigid rods with their backbone embedded among long alkyl side chains. Thus, it is challenging to experimentally quantify the conformation of a conjugated backbone. Here, we performed contrast variation neutron scattering on rigid conjugated donor–acceptor (D–A) diketopyrrolopyrrole (DPP) polymers with selectively deuterated side chains to measure the conjugated backbone conformation. We first synthesized DPPbased polymers with deuterated side chains, confirmed by NMR and FTIR. Using contrast variation neutron scattering, we found that the DPP-based conjugated polymers are much more rigid than poly(3-alkylthiophenes), with persistence length (L p ) at 16–18 nm versus 2–3 nm. More importantly, in contrast to the relatively flexible poly(3-alkylthiophenes) whose backbone is more flexible than the whole polymer, we found that the backbone of DPP-based polymers has the same L p value compared to the whole polymer chain. This indicates that side chain interference on backbone conformation is not present for the semirigid polymer, which is further confirmed by coarse-grained molecular dynamics (CG-MD) simulations. Our work provides a novel protocol to probe polymer’s backbone conformation and paradigm-shifting understanding of the backbone conformation of semirigid conjugated polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗