Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Development of local-power-free, remote α -particle detection using optical fibers

We demonstrate the application of fluorescence optical fiber coupled to a telecom grade fiber as a sensor for alpha particles using alpha-specific ZnS(Ag) scintillation materials whose wavelength is down-shifted into a low-loss region of the telecom grade fiber transmission band. Telecom-grade fiber optics offer a solution for sensing alpha radiation in deep repositories and cask storage for radioactive materials due to the stability of SiO 2 under normal environmental conditions and its relative radiation hardness at low radiation doses. Long-term nuclear waste storage facilities require sensors for the detection of leakage of radioactive materials that are maintenance-free, do not require power and can survive with no ‘wear out’ mechanisms for decades. By accomplishing the wavelength transformation, we maximize efficiencies in the detection of α-particles and signal transport and can detect alpha scintillation at distances on the order of >1 km with a sensor that is ~3% efficient and can be easily scaled as a sensor array. This paper describes the construction and testing of the sensor including manufacture of the controlled thickness films, verification of the wavelength shift from 450 to 620 nm and optimization of the sensitivity as a function of thickness. We also model the relative sensitivity of the film as a function of film thickness, and we demonstrate a signal-to-noise ratio of 10 at a range of greater than 1 km.

alpha particles↗

Magnetic Calorimeter Arrays with High Sensor Inductance and Dense Wiring

We describe prototype arrays of magnetically coupled microcalorimeters fabricated with an approach scalable to very large format arrays. The superconducting interconnections and sensor coils have sufficiently low inductance in the wiring and sufficiently high inductance in the coils in each pixel, to enable arrays containing greater than 4000 sensors and 100,000 X-ray absorbers to be used in future astrophysics missions such as Lynx. We have used projection lithography to create submicron patterns (e.g., 400-nanometer-lines and spaces) in our niobium sensor coils and wiring, integrated with gold-erbium sensor films and gold X-ray absorbers. Our prototype devices will explore the device physics of metallic magnetic calorimeters as feature sizes are reduced to nanoscale.

Magnetism↗

Active Control of Noise Using Actuator/Sensor Arrays

Current research in smart structures is directed toward the integration of many actuators and sensors into a material. In this paper we investigate the possibility of using this instrumentation for active noise control from a vibrating structures. Current technology for reducing radiated sound is limited by the instrumentation for the control system. These control systems employ relatively small numbers of sensors and actuators. Hence, these control systems must rely on a model of the structure to estimate and control the global vibrations that contribute to the far field pressure. For complex, realistic structures the development of such a model is a formidable task. The model is a limiting factor in the continuing development of structural acoustics. In this paper we propose to increase the number of actuators and sensors of a smart material to offset the complexity of the model used for control design. The sensor arrays will be used to directly sense the shape of the structure rather than using a model of the structures to indirectly sense the shape of the structure. The actuator array is used to apply distributed forces to the structure, rather than using the structure itself as a load path. A control system for the active cancellation of sound is derived from standard control system methodologies.

Lindner, Douglas K.↗

Instrumentation for vector electric field measurements from DE-B

Instrumentation has been developed, using the symmetric double-floating probe technique, to make vector electric field measurements from the low-altitude Dynamics Explorer (DE-B) spacecraft. Six 11-m cylindrical antennas are deployed along three orthogonal axes to form the sensor array. The outer two meters of each element are used as sensors, which results in a baseline of 21.4 m for the dc measurement for each axis. Efforts have been made to provide straight antennas and antennas that will not bend from thermal stresses as sun angles are changed. Measurements of the dc electric field will be made 16 times/sec or every half-kilometer along the orbit. Sensitivity will be 0.1 mV/m with a range of + or - 1 V/m. A 20-channel comb filter spectrometer will monitor ac electric fields, concentrating on frequencies below 1 kHz. Electric fields from any single axis or two axes may be sampled by the spectrometer within the range of 1 microvolt/m to 10 mV/m

Maynard, N. C.↗

Cross-correlation and image alignment for multi-band IR sensors

We present the development of a cross-­‐correlation algorithm for correlating objects in the long wave, mid wave and short wave Infrared sensor arrays. The goal is to align the images in the multi-­‐ sensor suite by correlating multiple key features in the images. Due to the wavelength differences, the object appears very differently in the sensor images even the sensors focus on the same object. In order to perform accurate correlation of the same object in the multi-­‐band images, we perform image processing on the images so that the features of the object become similar to each other. Fourier domain band pass filters are used to enhance the images. Mexican Hat and Gaussian Derivative Wavelets are used to further enhance the features of the object. A Python based QT graphical user interface has been implemented to carry out the process. We show reliable results of the cross-­‐correlation of the objects in multiple band videos.

Torres, Gilbert↗

Investigation and modification of a commercially available tactile sensor suited for robotic applications

Active (dynamic) tactile sensing was explored using a commercially available tactile array sensor. This task requires the redesign of the sensor interface and a full understanding of the old sensor hardware implementation. There were different stages to this research; the first stage involved the reverse engineering of the old tactile sensor. The second stage had to do with the exploration of the characteristics and behavior of the tactile sensor pad. The next stage dealt with the redesign of the sensor interface using the knowledge gained from the previous two stages. Finally, in the last stage, software to control the tactile sensor was developed to aid in the data acquisition process.

Creus, Carolina↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

Thermo-Hydro-Mechanical Modeling of Brine Migration in a Heated Borehole Test in Bedded Salt

Abstract This research paper focuses on the thermo-hydro-mechanical (THM) modeling of brine migration in a heated borehole test conducted as part of the ongoing Brine Availability Test in Salt (BATS) at the Waste Isolation Pilot Plant (WIPP) in New Mexico. It is a component of the international collaboration project DECOVALEX-2023 (DEvelopment of COupled models and their VALidation against EXperiments), which aims to understand the THM processes governing brine flow in heated rock salt repositories through collaborative analysis by multiple research teams. Using the TOUGH–FLAC simulator, THM simulations were performed and compared with data from the BATS phase 1a. This experiment involved two identical horizontal-borehole arrays, one heated and one serving as a control, both equipped with sensor arrays. Analysis of measurements revealed water flow rate surges during heater power transitions, with the highest jump observed during cooling. Acoustic emission activity exhibited distinct patterns in response to heater power changes, suggesting that damage to rock salt is particularly pronounced during the cooling phase. The THM simulations successfully captured these phenomena, highlighting the significance of thermal effects, brine migration, and mechanical behavior in predicting brine availability in heated and damaged rock salt. Our modeling also revealed the critical interplay between heating and cooling-induced damage and its influence on flow properties, particularly affecting brine inflow estimation. Notably, we found that cooling-induced brine inflow spikes result from increased permeability due to tensile dilatancy. These findings have important implications for the development of robust containment strategies and enhance our understanding of the complex processes involved in repository performance.

58 GEOSCIENCES↗

Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The recent discovery of high temperature ceramic superconductors with transition temperatures above 90 K has opened the possibilities for new space applications. One application is the fabrication of an electrically conducting and thermally isolating electronic link to connect IR detectors to data acquisition electronics on remote sensing platforms. The Spectroscopy of the Atmosphere using Far Infra-Red Emission (SAFIRE) mission is an example of a platform which employs hybrid dewars and combines both mechanical and cryogenic liquid cooling. This new technology is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). This link must be made of material that has high electrical conductivity and high thermal resistance. The YBa2Cu3O(x) superconductor with a transition temperature, T(sub c), of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. A reduction of the thermal load due to the link by a factor of four will increase the lifetime of a seven year mission by about one year.

Selim, Raouf L.↗

Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The discovery of a new class of ceramic superconductors with transition temperatures above the boiling point of liquid nitrogen has opened the doors for several space applications. One important space application is the fabrication of an electrically conducting and thermally isolating link to replace manganin wires used in connecting IR detectors to data acquisition electronics on remote sensing platforms like SAFIRE and SIRTF. These NASA platforms designed to monitor the earth's atmosphere from space use infrared detectors which operate at liquid helium temperature (4.2K) for optimum performance. The SAFIRE mission employs hybrid dewars which combine both mechanical and cryogenic liquid cooling. The lifetime of such a mission is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). Currently these remoter sensing systems use manganin wires to connect the IR detectors to the data acquisition electronics. This link between a detector operating at 4 K and electronics operating at 80 K must be made of material that has high electrical conductivity and high thermal resistance. The YBCO superconductor with a transition temperature, Tc, of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. The fabrication of an electrically conducting and thermally isolating link that replaces the manganin wires is an important application that will improve thermal isolation of IR detectors and will increase the lifetime of the cryogen. The link is made by screen printing superconducting lines on a low thermal conductivity ceramic substrate. Developing, modeling, and testing this high temperature superconducting link is a collaborative effort among NASA-Langley Research Center, Christopher Newport University (CNU), Clemson University and the industrial companies that have joined the Commercialization of Space Program for the purpose of developing and testing this link. CNU's effort in the development of this superconducting link included the following major efforts: (1) Development of a thermal conductivity measurement system for high temperature superconductors and ceramic materials which are potential candidates for use as substrates in this link. (2) Development of a mathematical model for the superconducting link that studies the effect of materials and geometry on the heat load and life time of missions. (3) Characterization of high Tc materials and assemblies made for space applications. Properties studied include humidity effects and aging effects on high Tc materials. This report summarizes the results of the research studies that were completed. Copies of publications detailing these findings are attached to this report.

Selim, Raouf R.↗

Durable Tactile Glove for Human or Robot Hand

A glove containing force sensors has been built as a prototype of tactile sensor arrays to be worn on human hands and anthropomorphic robot hands. The force sensors of this glove are mounted inside, in protective pockets; as a result of this and other design features, the present glove is more durable than earlier models.

Butzer, Melissa↗

Multi-Functional Distributed Fiber Sensors for Pipeline Monitoring and Methane Detections. Final Report

As an abundant and cheap fossil energy source, natural gas has become a significant energy supply to support the United States’ economy. However, the large-scale extraction and utilization of natural gas also impose significant challenges on methane leakage. This problem is exacerbated by aging gas utility delivery systems, including interstate high-pressure pipelines, storage, and transmission facilities. This project aims to develop a cost-effective fiber optical sensing method that can perform multi-parameter real-time measurements of natural gas pipelines across long interrogation distances up to 100 km with 1-meter spatial resolution. This sensing tool can evaluate overall pipeline efficiency and reduce methane emissions for mid-stream methane infrastructures. To accomplish this objective, research and development efforts funded by this project have resulted in the following accomplishments: This project successfully has developed new functional sensory polymer materials using Metal-Organic Frameworks (MOFs) that can be coated on optical fiber through the reel-to-reel coating process. Functional polymer-coated optical fibers can perform sensitive methane detection through evanescence wave interaction and strain-based measurements to achieve 1% detection sensitivities. The new sensors fibers support both distributed measurements and multiplexed fiber sensors array for multi-point measurements. This project developed and optimized a new multi-core optical fiber that supports simultaneous and distributed measurements of strain and temperatures with 1-meter spatial resolutions across up to 100-km interrogation distance. This new fiber, combined with sensory polymercoated fiber, could perform both distributed temperature and methane detections. This project developed a new artificial intelligence big data algorithm approach that can effectively analyze high-resolution data harnessed by distributed fiber sensors to protect natural gas pipelines against external threats and detect internal defects induced by corrosion. Working with our industry partner, this project developed new optical fibers that support fiber sensor fabrications through polymer coating after the fibers are drawn. These new fibers eliminate the need for direct sensor fabrication when the fiber is fabricated on a fiber draw tower, which drastically expands fiber sensors' applicability. This research project has significantly advanced the distributed fiber sensing technology. It will dramatically increase the applicability and adaptability of distributed fiber sensors for a wide array of applications in energy, sustainability, and environmental science, including structural health monitoring of natural gas pipelines, oil infrastructures, hydrogen facilities, and environmental monitoring of carbon storage sites, water supply systems, and others.

03 NATURAL GAS↗

Investigation of optical/infrared sensor techniques for application satellites

A method of scanning an optical sensor array by acoustic surface waves is discussed. Data cover detailed computer based analysis of the operation of a multielement acoustic surface-wave-scanned optical sensor, the development of design and operation techniques that were used to show the feasibility of an integrated array to design several such arrays, and experimental verification of a number of the calculations with discrete sensor devices.

Kaufman, I.↗

Static calibration for measurement of loads in wind tunnel tests on Shuttle surface tiles

A description is given of the procedures used for the static calibrations of the Coe (1981) sensor array to determine normal force, pitching moment, and rolling moment from the ensemble of sensor outputs. The use of independent data to confirm the validity of the calibration is also described. Two methods are used in calibrating the Coe sensors. In the first, calibration loads and readings are arranged in matrix form and are assumed to be related in a linear fashion. In the second, each Coe sensor reading is regarded as a sum of contributions from each of the calibration loads. It is shown that the Coe load sensors, in conjunction with either of two data analysis methods, can be used to determine the forces and moments experienced by a Shuttle TPS tile.

Rummler, D. R.↗

Seismoacoustic Data Fusion for Ground Coupled Airwaves: a FACT Case Study for Calibration and Array Processing

This report covers an inquiry into seismoacoustic array processing using infrasound arrivals combined with resulting Ground Coupled Airwaves (GCA) that are present on collocated seismic sensors. In preparation, data calibration and denoising is completed for a seismoacoustic sensor array that was deployed at the Facility for Acceptance, Calibration, and Testing on Kirtland Airforce Base from August through September of 2021. The events of interest for this study are small, local explosive sources that lead to short duration, impulsive signals on the instruments. The goal is to determine if combining infrasound signals with the corresponding GCAs on collocated seismic sensors can be used to improve the results returned by automated signal detection and characterization (e.g., back azimuth estimates). Preparation for seismic and infrasound data involves removing the instrument response so that sensors have flat power spectra over the frequency range 0.1-10 Hz, where signal from events of interest may be detected. After instrument response removal, deployment conditions specific to this array require a retrospective noise analysis to determine station emplacement characteristics. Once all data is calibrated, a manual search is performed for possible GCA arrivals across the seismoacoustic network. These arrivals are then processed through beamforming and subsequent event identification, resulting in a catalogue of seismoacoustic GCA arrivals with corresponding back azimuth and trace velocity estimations.

47 OTHER INSTRUMENTATION↗