Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Behavior of the Fused Quartz Suspended Core Acoustic Waveguide Sensor in Gamma Radiation

Previously, a fused-quartz acoustic waveguide named the suspended core waveguide with tight-field confinement in a small diameter was developed and its sensing potential in harsh environment was demonstrated with the fabricated periodic acoustic fiber Bragg grating. In this paper, the acoustic sensor was exposed to around 70 Gy/h gamma radiation at room temperature for 3550 h at Oak Ridge National Laboratory. For comparisons, a thermocouple and two optical fiber Bragg gratings were tested under the same conditions. The central frequency reading of the acoustic sensor was found to encounter a relatively fast decrease of 0.5 kHz in the first 800 hours. The reading then became stable, centering at 478.5 kHz with a fluctuation of ±0.2 kHz, and responded to small environmental temperature variations less than 1.2 °C. The major effect to the fluctuation was concluded to be radiation-induced material compaction and expansion. For optical fiber Bragg gratings, the same one-directional fast change of readings in the first 500 hours were observed as well. Although the optical gratings were able to track temperature changes, they also showed continuous drifts. The survivability and consistency of the acoustic sensor under long-term gamma radiation could lead to new sensing methods in nuclear applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Digital risk analysis in nuclear engineering projects: Designing for safety, performance, reliability, and security

Cyber-informed engineering and security-by-design frameworks are important in promoting the need to identify cybersecurity concerns early in the systems engineering lifecycle so risks from adversarial cyber-attacks can be eliminated or reduced through engineering design practices. In addition to adversarial risk, risk in operational technology systems also includes non-adversarial and unintentional risk from other factors such as human performance errors, environmental conditions, design flaws, and device degradation or failure. This paper introduces a new concept for characterizing digital risk, both adversarial and non-adversarial, and provides the basis for initial research into a novel digital risk analysis approach focused on incorporating attack difficulty into a multi-attribute analysis technique using robust decision-making. This digital risk characterization is also used to frame a discussion on the challenges of competing objectives and competing stakeholder requirements in an integrated energy system project that incorporates a small modular reactor and industrial facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Scientific Justification for a U.S. Domestic High-Performance Reactor-Based Research Facility

The Basic Energy Science Advisory Committee (BESAC) was charged with forming a subcommittee to assess the scientific justification for a U.S. domestic high-performance reactor-based research facility in order to continue providing the U.S scientific community with leading neutron capabilities in support of DOE's missions in science, energy, environment, and national security. The assessment included consideration of current international plans and existing domestic facility infrastructure. The subcommittee held a series of meetings from August 19, 2019 to April 24, 2020 that included DOE senior officials, leaders of national and international neutron facilities (SNS, HFIR, NIST, ILL, FRM-II), chairs of the NAS and POPA HEU-LEU committees, and outside experts on important areas of science, technology, and industry where high flux nuclear reactor facilities make important contributions. Also included were tours of neutron facilities (SNS, HFIR, NIST, BR2 reactor, and the planned Jules Horowitz Reactor). This July 2020 (revised 10-28-2020) report describes scientific use cases, brief summaries of existing and planned neutron facilities in the US and Europe, a comprehensive review of HFIR, a comprehensive discussion of the current state of progress on HEU-LEU conversion, user information from NIST and ORNL, and three recommendations to DOE for moving forward.

36 MATERIALS SCIENCE↗

Quantitative Determination of Total Cesium in Savannah River Site (SRS) Tank Waste by Inductively Coupled Plasma Emission Spectroscropy

Utilization of the significant and unique wavelength dynamic range (165 to 1100 nm) available on the Leeman Prodigy Inductively Coupled Plasma Emission Spectroscopy (ICP-ES) allows for quantification of cesium using the emission line 894.347 nm without the potential of Barium interference in nuclear waste samples. Samples are added to a Sodium Peroxide Fusion and Lithium Carbonate buffer in 2% nitric acid solution to increase sensitivity of the easily ionizable (<6 eV) cesium for quantitation to 5 pbb. Through direct comparison of analytical data results, the method is proven to be complementary to the Inductively Coupled Plasma Mass Spectrometry (ICP-MS) analysis (LOQ 100 ppt) in support of the Department of Energy’s (DOE) Nuclear Waste Mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

H-Canyon exhaust tunnel LiDAR data request for information review and release

This request is to release LiDAR data files acquired by SRNL R&D Engineering and H-Area Operations and Engineering while performing scans of the interior of the H-Canyon Exhaust tunnel. LiDAR data includes 3-dimensional (3D) point cloud data sets and panoramic digital images of the interior tunnel wall surfaces. Presently two deployments have been completed, the first in November 2019, Fig. 1, and the second in June of 2020. This request is for the release of the data collected during those two deployments. Detailed information on the deployment and data collected can be found in SRS document C-ESR-H-00072, “November 2019 Initial Deployment of LiDAR”. It is planned to perform ongoing scans at approximately 6-month intervals, the purpose of the deployments is to evaluate the usefulness of the data collected to enable quantitative measurements such as tunnel dimensions and rate of surface erosion and as a precursor to a potential deployment of a LiDAR system on the tunnel inspection crawler.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

November 2019 Initial Deployment of LiDAR in the H-Canyon Exhaust Tunnel

The H-Canyon Exhaust Tunnel (CAEX) structure is periodically inspected under the Structural Integrity Program using camera equipped crawlers or poles to remotely perform visual inspections. To explore the use of enhanced inspection methods a “Proof of Concept” using the Light Detection and Ranging (LiDAR) technology was performed over a 2-day period in November 2019. The purpose of the “Proof of Concept” deployment was to confirm whether a commercially available LiDAR unit could successfully operate and remotely transmit data from the tunnel CAEX environment and whether the data would provide quantitative information to establish baseline measurements. The LiDAR performance requirement was a measurement accuracy of ± 0.25-inches over a 30-foot distance. This report documents the work activities leading to the deployment, the deployment and processing of data, lessons learned from the deployment and the post data processing methods that will be applied to future deployments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large Surface Explosion Coupling Experiment - SNL Remote Optical.

Two surface chemical explosive tests were observed for the Large Surface Explosion Coupling Experiment (LSECE) at the Nevada National Security Site in October 2020. The tests consisted of two one-ton explosions, one occurring before dawn and one occurring mid- afternoon. LSECE was performed in the same location as previous underground tests and aimed to explore the relationship between surface and underground explosions in support of global nonproliferation efforts. Several pieces of remote sensing equipment were deployed from a trailer 2.02 km from ground zero including high-speed cameras, radiometers and a spectrometer. The data collected from these tests will increase the knowledge of large surface chemical explosive signatures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Experiments at TA-55 have used optical pyrometry to measure temperatures of shocked plutonium on the 40mm gun

Researchers at LANL, along with collaborators from MSTS, have worked for more than a decade to develop and implement an optical pyrometry method to measure the temperature of metals shocked to the high pressures and temperatures. Because traditional shock wave measurements only provide information on the mechanical state of the material, temperature measurements are required to validate and improve equation-of-state (EOS) models for materials. The conditions sampled are complex; commenserate with those found in planetary impacts, and accressed by conventional and nuclear weapons. Optical pyrometry is currently the best available method for inferring the temperature of shocked metals, by careful measurement of the calibrated radiance emitted by a surface at finite temperature. These measurements are difficult often complicated by the short time scales associated with shock wave experiments (<1 µs) coupled with the many sources of non-thermal light (impact flash, fracture light, etc.) that pollutes the radiant light measured from the sample.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Template size and proper overlap detection in Laser Confocal Microscope (LCM) images [Slides]

The LCM has been used to interrogate the inside of hazardous material 3013 storage containers resulting in many LCM images. Joining these images together to create one large image allows one to see features, potential cracking and potential pitting, that extend from one image to another. The images have been found to cover some (5% – 10% at the edges) of the same sample area. This overlap appears to change slightly from image to image so that a global overlap value does not solve the stitching problem. It will be necessary to determine the proper overlap for two adjacent, horizontal or vertical, images. The methodology presented here shows how to estimate the overlap.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-ray diffraction and scanning electron microscope characterizations of the salt waste processing facility tank 101 and tank 104 solid samples

The “as-received” Salt Waste Processing Facility (SWPF) Tank 101 and two Tank 104 samples (pre-wash and washed solids) have been characterized using x-ray diffraction (XRD) and scanning electron microscope/energy dispersive x-ray (SEM/EDX) techniques to address the concerns for the existence of solids, which may interfere with the operational performance of the SWPF crossflow filtration process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electroanalytical Sensors for Liquid Fueled Fluoride Molten Salt Reactor

ThorCon is developing a thermal thorium / uranium molten salt fueled reactor that uses a fuel salt consisting of NaF - BeF 2 - ThF 4 - UF 4 - UF 3 , which uses 19.75% enriched uranium. It is not a breeder reactor but requires regular additions of fissile material. On-site fuel processing is limited to adding make-up fuel, and adding beryllium to maintain redox balance in the fuel salt. The fluoride salt is an excellent flux that will strip the protective oxygen away from all metal surfaces it contacts. In order to protect the metal surfaces in the primary loop, no free fluorine is allowed. Maintaining a ratio of UF 4 to UF 3 provides a chemical buffer that can absorb any free fluorine released during the fission process before it can harm the structure. Periodic additions of metallic beryllium to the fuel salt will react with UF 4 to form BeF 2 and UF 3 , which will maintain the desired UF 4 /UF 3 ratio. A means to measure the UF 4 /UF 3 ratio is important to maintain the fuel salt in a non-corrosive state and could also provide additional insight into the corrosion behavior and chemical constitution of the system. A promising measurement technique is based on electrochemistry.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Forensics

Nuclear forensics is a key part of the nuclear security strategy for the United States and the international community. The NACS Division is central to the leadership role that LLNL has had in nuclear forensics over the past 25 years. Our current nuclear forensic program includes conducting R&D on provenance and attribution signatures, collaborating with international partners, training the next generation of nuclear forensic experts, developing test materials for verification and validation exercises, and providing expert advice to national and international policy makers. Key to our success in these areas has been the strong and continuing involvement in nuclear forensic casework obtained through law enforcement and intelligence channels as well as our outstanding analytical capabilities. NACS must continue to conduct forward-thinking R&D in nuclear forensics that supports operational programs and addresses intelligence gaps. To maintain leadership in nuclear forensics, we must attract, develop, and retain the best talent. The NNSA has a central leadership role in developing educational initiatives for nuclear forensics. In concert with the Glenn T. Seaborg Institute, the NACS Division will continue to participate in all nuclear forensic educational initiatives (undergraduate, graduate, postdoctoral) and incorporate LLNL’s D&I vision into its student and postdoc recruitment efforts. We will continue to build formal relationships with key academic partners and institutions with active and emerging nuclear forensic research interests. We will also strengthen relationships with NNSA DNN and SSAA funded university consortia (e.g. NSSC, ACE, CNEC, CVT, ETI, MTV), helping them conduct research of interest and relevance to nuclear forensics, while at the same time evaluating and recruiting promising talent from these programs.

07 ISOTOPE AND RADIATION SOURCES↗