Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid quality power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A microgrid deployment framework to support drayage electrification

The electrification of heavy-duty commercial vehicles (HDCVs) is key to enhancing air quality and reducing urban air pollution, but it also imposes significant demands on an electric grid not designed for such high loads. Without complementary infrastructure, electrification may yield limited air quality improvements. This article explores the critical role of microgrids—integrating solar photovoltaics and battery storage—in supporting HDCV electrification. We present an integrated framework to identify viable microgrid sites in a given region, estimate deployment costs, and optimize power use to reduce dependence on the grid. As a case study, we apply the framework to the region around the Port of Savannah, GA, USA, demonstrating how targeted microgrid deployment can enhance grid capacity, improve energy resiliency, and support electrified freight transport.

Electrical engineering↗

Scenario Creation and Power-Conditioning Strategies for Operating Power Grids with Two-Stage Stochastic Economic Dispatch: Preprint

A significant difficultly associated with the use of stochastic programming to solve optimal power flow problems on a 5-minute timescale is the quality of renewable energy scenarios input by the user. This is especially true when considering power systems with high penetrations of renewable energy, e.g. wind power. This paper introduces the use of stochastic programming to solve the DCOPF problem with scenarios drawn directly from high-fidelity data sets. Hence, the proposed method avoids the problem of lost physics by finding high-fidelity analogs that can describe future states of the system. Furthermore, this method can be simply extended to output multi-period scenarios to the stochastic program. We demonstrate the effectiveness of this technique on simulated dispatch operations of the RTS-GMLC over a week.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Iterative Multi-site Hosting Capacity Analysis for Distribution Systems With Search Space Pruning

Interconnection studies for distributed energy resources (DERs) is a time-intensive process, primarily due to the necessity of solving large number of power flow scenarios. Hosting capacity analysis (HCA) is a time-consuming aspect of interconnection studies that is divided into single-site HCA (SHCA) and multi-site HCA (MHCA). From a computational and understandable standpoint, the industry seeks iteration-based solutions for SHCA, although it doesn't maximize the total DER hosting capacity (DERHC) of the grid, as MHCA does. While non-iterative solutions are available for MHCA, they involve a trade-off between the modeling accuracy of the distribution system, solution quality, and ease of understanding. In this work, we present a fast iterative solution for MHCA, reducing computational complexity by eliminating the need to solve power flows for a large amount of search space, thus making iterative solutions feasible. This iterative approach guarantees both a global optimal solution with sufficient time and a fast, close-to-optimal solution through efficient search space pruning. It also easily integrates with existing utility HCA tools. The results are demonstrated on select locations in the IEEE-123 bus system for community-scale interconnection studies. We highlight the benefits of skipping the need to solve millions of power flows, all while maximizing the grid's total DERHC.

Guddanti, Kishan Prudhvi↗

Regional Energy Deployment System (ReEDS)

The Regional Energy Deployment System (ReEDS) is a deterministic optimization model of the deployment of electric power generation technologies and transmission infrastructure throughout the contiguous United States into the future. The model, developed by the National Renewable Energy Laboratory's Strategic Energy Analysis Center, is designed to analyze the critical energy issues in the electric sector, especially with respect to potential energy policies, such as clean energy and renewable energy standards or carbon restrictions. ReEDS provides a detailed treatment of electricity-generating and electrical storage technologies and specifically addresses a variety of issues related to renewable energy technologies, including accessibility and cost of transmission, regional quality of renewable resources, seasonal and diurnal generation profiles, variability of wind and solar power, and the influence of variability on the reliability of the electrical grid. ReEDS addresses these issues through a highly discretized regional structure, explicit statistical treatment of the variability in wind and solar output over time, and consideration of ancillary services' requirements and costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗

Wind Turbine Generator System Duration Test Report for the ARE 442 Wind Turbine

This test is being conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. In total, four turbines are being tested at the NWTC as a part of this project. Duration testing is one of up to 5 tests that may be performed on the turbines, including power performance, safety and function, noise, and power quality tests. The results of the testing provide manufacturers with reports that may be used for small wind turbine certification. The test equipment includes a grid connected ARE 442 wind turbine mounted on a 30.5 meter (100 ft) lattice tower manufactured by Abundant Renewable Energy. The system was installed by the NWTC Site Operations group with guidance and assistance from Abundant Renewable Energy.

17 WIND ENERGY↗

Development and Validation of a SiC Based 50 kW Grid-Connected PV Inverter: Preprint

In this digest a 50kW string PV inverter formed using all SiC semiconductor devices is presented. The inverter design includes additively manufactured power block, symmetrical Y-core inductors for ac side filter, and advanced inverter functionality for grid support. This inverter utilizes the conventional three-phase Voltage Source Inverter topology and optimizes the design for SiC based devices. This paper presents the full functional validation of the designed inverter along with quantification of the efficiency and power density. The performance of the inverter for high dc-bus voltage without multi-level topology to exploit SiC advantages is also presented in this digest. The full paper will include details of inverter design, optimization and further experimental validation.

14 SOLAR ENERGY↗

Solid electrolyte for solid-state batteries: Have lithium-ion batteries reached their technical limit?

With increasing demand for electrical power on a distribution grid lacking storage capabilities, utilities and project developers must stabilize what is currently still intermittent energy production. In fact, over half of utility executives say “the most important emerging energy technology” is energy storage. Advanced, low-cost battery designs are providing promising stationary storage solutions that can ensure reliable, high-quality power for customers, but research challenges and questions lefts. Have lithium-ion batteries (LIBs) reached their technical limit? The industry demands are including high costs, inadequate energy densities, long recharge times, short cycle-life times and safety must be continually addressed. Safety is still the main problem on developing the lithium ion battery.The safety issue must be considered from several aspects, since it would become serious problems, such as an explosion in a Japan Airlines 787 Dreamliner’s cargo hold, due to the battery problem. The combustion is mainly due to the leakage or shortcut of the electrodes, caused by the liquid electrolyte and polymer separator. For this reason, the research on solid electrolyte for replacing the existing liquid electrolyte is very important. The materials used in existing lithium ion battery, such as a separator and liquid electrolyte must be replaced to new solid electrolytes, solid materials that exhibits high ionic conductivity. Due to these reasons, research on solid state ionics materials have been vastly growing worldwide, with the main aim not only to search new solid electrolyte to replace the liquid one, but also looking for low cost materials and environmentally friendly. A revolutionary paradigm is also required to design new stable anode and cathode materials that provide electrochemical cells with high energy, high power, long lifetime and adequate safety at competitive manufacturing costs. Lithium superionic conductors, which can be used as solid electrolytes, promise the potential to replace organic liquid electrolytes and thereby improve the safety of next-generation high-energy batteries. Li{sub 3}PO{sub 4} has been proved to be a good candidate for solid electrolyte, due to its easy in preparation, low cost, high melting temperature and good compatibility with the electrode materials. In the present work, Li{sub 3}PO{sub 4} has been prepared by wet chemical reaction, a simple method with the advantage of recycling a waste product H{sub 3}PO{sub 4}. The crystal structure has been characterized by both neutron and x-ray diffraction. The use of neutron scattering plays important role on observing the light atoms such as lithium ion. The x-ray diffraction results showed the crystal structure of orthorhombic phase P m n 21 (31), that belongs to the β-Li{sub 3}PO{sub 4}, with the lattice parameters are a = 6.123872, b = 5.250211, c = 4.876378. The conductivity of β-Li{sub 3}PO{sub 4} was around 10{sup −8} S/cm. Furthermore, the future application of the solid electrolyte layer in lithium ion battery will also be considered. It is concluded that the used of local resources on producing the solid electrolyte Li{sub 3}PO{sub 4} for lithium ion battery will give more added values to the researches and national industry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Powering Post-COVID-19 Resilient Recovery with Green Stimulus

As the coronavirus disease (COVID-19) pandemic spread globally in early 2020, many governments enacted lockdown measures as an initial containment response. These lockdowns, while effective in slowing infection rates, have also had substantial economic consequences. A series of supply and demand shocks, workforce and supply chain disruptions, and other impacts of the pandemic and ensuing lockdowns have upended the livelihoods for much of the world's population. This quick read spotlights how green stimulus plans and other recovery measures can support near-term recovery and enable longer-term power system resilience against future threats. The term “green stimulus” encompasses fiscal measures (i.e., governmental tax and spending actions) that support short-term economic activity that enhances environmental and natural resource quality over a longer term. The deployment of energy efficiency (EE) and renewable energy (RE) technologies, as well as associated initiatives (e.g., grid modernization, electrification of transport, and so on) have been demonstrably effective in providing this kind of short-run economic boost while simultaneously strengthening the resilience of the power sector. Along with green stimulus packages, concurrent action on the regulatory side—for example, the development of green building codes, updating grid interconnection standards, creating programs and marketplaces for demand-side efficiency, and others—can be a force multiplier in ensuring that public spending achieves maximum impact in near-term recovery and long-term power sector transformation

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services

Flexible loads have great potential to improve the electric grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. This paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environmental impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

61 RADIATION PROTECTION AND DOSIMETRY↗

Aerodynamic and Aerothermal Simulations of Mars Concept Vehicles Using Overset DPLR

NASA's Descent System Studies (DSS) Program is studying various concept vehicles to enable landing of heavy payloads on the surface of Mars. While it is desirable to run high-fidelity CFD simulations to accurately assess the aerodynamic and aerothermal effects of various design changes during EDL, it is usually difficult to quickly generate high-quality grids suitable for such analyses. One approach to address this bottleneck in mesh generation is through the use oversetting grids. Although the overset approach is efficient and powerful in solving partial differential equations on complex geometries, new users often find it challenging to apply overset concepts for their simulations. For example, generating hyperbolic grids with sufficient overlap; priority in hole-cutting on multiple overlapping grids; and fixes to assemble overlapping viscous grids at the body surface. The objective of this presentation is to introduce a simple process that combines the advantages of near-body, point-matched, structured grids with oversetting background grids suitable for grid alignment. This approach allows for grids that can be sequenced, reclustering of mesh spacing at the wall, and grid alignment with the bow shock. The current methodology is tested on a Mid-L/D configuration using the overset DPLR code.

Overset Grids↗

PHEV Distribution Grid Integration and Smart Systems Testing: Cooperative Research and Development Final Report

To continue NREL's mission, which includes preparing technologies and markets with "speed and scale," NREL researchers will collaborate with Toyota on plug-in electric vehicle technology. Toyota will provide a collection of plug-in hybrid electric vehicles ("PHEVs" [and ultimately including PEVs], collectively, the "Vehicles") to conduct infrastructure interaction testing at NREL facilities. NREL will use available resources in the Vehicle Testing and Integration Facility (VTIF), its staff parking garage with numerous commercial Electric Vehicle Supply Equipment ("EVSEs"), and its Energy Systems Integration Facility (ESIF) to safely execute research experiments that highlight potential distribution system power quality challenges related to plug-in electric vehicles. The expected outcome of this project is a better understanding of the correlation of individual vehicle power quality attributes to a system of vehicles on a distribution network. The data collected and the simulations conducted will be used to guide future experiments and project development that aid in the deployment of plug-in electric vehicles ("PEV").

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vis-SAGA: Visual Analytics for Situational Awareness of Grid Anomalies: Preprint

We describe supporting near real-time situational awareness of the electric distribution system by visualizing novel data from voltage sensors deployed on existing broadband cable television network equipment. Our scalable web-based visual analytics platform supports interactive geospatial exploration, time-series analysis, and summarization of grid behavior during potentially anomalous events. The broadband cable television sensor network provides observability of the electrical distribution system at a higher local spatial resolution than is typically available to most utilities, revealing the operational state of the network and aiding in the detection of abnormal behaviors or deviations from expected patterns, particularly across electric utility service areas. We outline the design and development of interactive geospatial and time-series visualization components and the scalable data services that supply metadata, historical, and real-time streams of sensor data across the network. We evaluate our platform during periods of extreme weather, demonstrating its ability to assist in detecting patterns of operation that affect power availability, quality, resiliency, and service restoration.

cable television↗

Power System Resilience Metrics Augmentation for Critical Load Prioritization

One of the major goals of new grid operation regimes, such as transactive energy systems (TESs), is to make the power grid more resilient to withstand natural or man-made disasters and potential reliability events, and to continue to serve the maximum number of its customers. But it is a well-known fact to system operators that not all customers are the same. This implies that any discussion of TESs’ impacts on the resilience of the power system should consider the needs of its critical customers (such as the power system operation centers, fire and police stations, and hospitals) over those of other customers. When evaluating the resilience of the system, bonus points must be awarded to any system that could maintain its power supply to critical customers during a disturbance that may cause an outage. This report discusses critical infrastructure (CI) as found in the literature and then categorizes it based on the field to which the operations belong (such as human life/safety-related, operations management, necessary city operation, industrial customers, etc.). Each of these CI categories is further divided into types of critical customers (e.g., the human life/safety-related category has different types of customers like hospitals, fire and police stations, etc.). The entire demand of each of the critical customer types is not categorized as critical load (CL); instead, only a portion of the total load of these critical customers is characterized as critical load. This is done based on the categories of equipment, the function of which is crucial in the operation of the overall facility. CL categorization is performed to provide the ratio of the critical load portion to the overall load , so that it can serve as a parameter in the resilience evaluation of the grid through a metrics-based approach. Such categorization is important as it helps to augment the existing quantifiable resilience metrics with CL categorization. The metrics for a power system need to not only consider how well a system performed during a disturbance event, but also how it reduced strain and supplied power to its CLs. The first step in this process is characterize CLs in the system. After CL characterization, the next step is the inclusion of these loads in the resilience metrics. To that end, in this report weight-based augmentation of resilience metrics is proposed, where certain customers (the ones that are categorized as critical) are assigned higher weights than others. Though an overview of assigning weights to customers is discussed, there is no one-size-fits-all approach for every power system. The decisions made about assigning such weights to customers vary greatly from one operator to another, based on their unique systems and the current and predicted states of critical customers. This decision-making can include the type of disturbance event, which might only affect certain parts of the system. In general, analyzing critical customers before an event helps understand system vulnerabilities. It also helps in planning and conducting operations during the event, evaluating system performance after the event, and supporting better planning for future events. An alternative to the current practices of managing the grid for outages is an innovative TES, which has the potential to provide a platform for including distributed energy resources for managing CLs. This report also describes how TES qualities can help (1) to maintain power supply to critical customers for uninterrupted operations and (2) to restore lost power supply to the critical customers rapidly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Koopman-based Differentiable Predictive Control for the Dynamics-Aware Economic Dispatch Problem

The dynamics-aware economic dispatch (DED) problem embeds low-level generator dynamics and operational constraints to enable near real-time scheduling of generation units in a power network. DED produces a more dynamic supervisory control policy than traditional economic dispatch (T-ED) that reduces overall generation costs. However, the incorporation of differential equations that govern the system dynamics makes DED an optimization problem that is computationally prohibitive to solve. In this work, we present a new data-driven approach based on differentiable programming to efficiently obtain offline parametric solutions to the underlying DED problem. In particular, we employ the recently proposed differentiable predictive control (DPC) for offline learning of explicit neural control policies based on identified Koopman operator (KO) model of the system dynamics. We demonstrate the high solution quality and five orders of magnitude computational-time savings of the DPC method over the original optimization-based DED approach on a 9-bus test power grid network.

King, Ethan↗

Metric-discontinuous zonal grid calculations using the Osher scheme

Computations on zonal grids - in particular, grids with metric discontinuities resulting from the interspersion of highly clustered regions with coarse regions - are possible using a fully conservative form of the Osher upwind scheme. These zonal grids can result from an abrupt clustering of points near solution discontinuities or near other flow features that require improved resolution. The zonal approach is shown to capture shocks with almost 'shock-fitting' quality but with minimal effort. Results for inviscid flow, including quasi-one-dimensional nozzle flow, supersonic flow over a cylinder, and blast-wave diffraction by a ramp, are presented. These calculations demonstrate the powerful capabilities of the Osher scheme used in conjunction with zonal grids in simulating flow fields with complex shock patterns.

Rai, M. M.↗

Integrating air quality and health considerations into power sector decarbonization strategies

Climate change and public health are two interconnected societal challenges. Curbing fossil-based electricity generation reduces the emissions of both CO 2 and air pollutants, which brings tangible health benefits from improved air quality. The potential health benefits from decarbonizing the grid are enormous, immediate, and widespread. From renewable portfolio standards to carbon market, the health co-benefits from clean electricity policies often outweigh their policy costs. As climate action goes local, framing decarbonization around health benefits also makes it more personally relevant and economically attractive. Yet, to date, the health impacts have largely been viewed as ancillary benefits from decarbonization, rather than as a core consideration when energy strategies are formed, assessed and implemented. When strategic choices are made about retiring old infrastructure and building new ones, bringing public health to the center of the discussion can generate greater health benefits with more equitable distribution. Here we identify concrete ways to incorporate air quality and health considerations into power sector decarbonization strategies. We draw insights mainly from empirical and modeling evidence for the United States. These insights are generally applicable and could guide health-oriented decarbonization efforts in other countries as well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗