Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “enclosure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Supplementary Shielding Specifications for the NSLS-II Booster Enclosure

Bulk shielding at NSLS-II has been designed to reduce the ambient dose rates to < 5.0 μSv/h (0.5 mrem/h) at the exterior surface of the concrete shielding, during typical operation. This limits the maximum exposure to < 10 mSv/y (1,000 mrem/y) at the occupied areas, assuming 2,000 hours ofoccupancy per year.

36 MATERIALS SCIENCE↗

Transmittal of the Sandia National Laboratories/New Mexico Five-Day Report for the Accidental Slug Discharge at the Albuquerque Bernalillo County Water Utility Authority (ABCWUA) Industrial Wastewater Permit No. 2069 Outfall [Letter and Enclosure]

This letter represents the five-day written notification for elevated fluoride levels at the Building 858N, Acid Waste Neutralization (AWN) System in accordance with the ABCWUA Sewer Use and Wastewater Ordinance § 3-6-5(B), Reports of Potential Problems. This AWN System is covered under the ABCWUA Industrial Wastewater Permit No. 2069G. The immediate notification to the ABCWUA occurred at 21:42 on August 1, 2019.

54 ENVIRONMENTAL SCIENCES↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Condenser Enclosure Vibration Isolation Mount Selection

A mini split cooling system will be used to maintain temperature requirements in a mobile secure transport system. While the split cooling system was designed to be used in static residential or commercial applications, it was selected for this transportation application due to a unique set of security requirements. However, the system’s ability maintain reliability and survive prolonged long-term shock and vibration is a significant concern. The mitigation strategy is to select vibration isolation mounts and perform lifetime shock and vibration testing to demonstrate survivability. The goal of this study is to generate a finite element model of the system and perform modal analysis to inform selection of vibration mounts to minimize the amount of vibrational energy transferred to the split cooling system. The scope of this report is limited to study of the condensing unit only, and geometric variation of the assembly will not be allowed.

42 ENGINEERING↗

Oak Ridge National Laboratory Thermoplastic Composite Joining of Pultruded Continuous Fiber Spars for Multi-Functional Battery Enclosure

Oak Ridge National Laboratory (ORNL) worked with DowAksa Industry to investigate the potential of using PA66 material to produce larger composite parts, transcending the limitations of traditional presses. The project aimed to develop a suitable material for printing battery boxes using Nylon 66 infused with 40 wt.% carbon fiber, compatible with the ORNL Additive Manufacturing and Compression Molding (AM-CM) system. However, even with extensive work, it was concluded that the material is not compatible with the AMCM process and suitable for joining using compression technique. Main reason for the incompatibility were found to be very high crystallinity of the PA66 grade chosen for this work. To improve printability, a modifier (proprietary) was added to decrease crystallinity, but this led to reduced thermal stability and adhesion issues.

36 MATERIALS SCIENCE↗

Methods and recommendations for large-scale deflagration testing of battery energy storage system enclosures

UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.

Gaudet, Benjamin [UL Solutions] (ORCID:00090006419↗

Absorption and Emission Characteristics of Diffuse Spherical Enclosures

The thermal radiation characteristics of spherical cavities are of practical interest in connection with the absorption of radiant energy for both space-vehicle and terrestrial applications. Also, spherical cavities are of potential use as sources of black-body energy. The purpose of this brief paper is to determine both the absorption and emission characteristics of spherical cavities which are diffuse reflectors and emitters.

EMISSION↗

Absorption and Emission Characteristics of Diffuse Spherical Enclosures

An analysis was made to determine the energy absorbed when radiation from an external source enters a spherical cavity with diffusely reflecting walls. It was found that both the overall energy absorbed in the cavity and the local distribution of absorbed energy could be expressed in terms of simple algebraic equations that are valid for any arbitrary spatial and directional distribution of the incoming radiation. In addition, the characteristics of an isothermal spherical cavity as a possible source of near black-body radiation were investigated. This information was also expressed by simple algebraic relations.

ABSORPTION↗