Fast-running Model of Thermal Runaway Propagation with Heat and Mass Transfer Within an Enclosure

Abstract

This material will be presented at the Interagency Advanced Power Group (IAPG) Chemical Working Group and Safety Panel Meeting. IAPG serves as the premier organization coordinating the collaboration and information exchange of advanced power research and development within the U.S. government.

Keep this discovery

BibTeXRIS

Meehan, Michael Alexander [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)] (ORCID:000000015102035X), Kurzawski, Andrew Joseph [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)] (ORCID:0000000232396244), Hewson, John Christopher [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)] (ORCID:0000000340535774). 2025-09-01. Fast-running Model of Thermal Runaway Propagation with Heat and Mass Transfer Within an Enclosure. https://doi.org/10.2172/3740893

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

NASA Alternative Orion Small Cell Battery Design Support

The NASA Orion Crew Module Reference Design was produced to address large scale thermal runaway (TR) hazard with specific safety controls for the Orion Spacecraft. The design presented provides the description of a full scale battery design reference for implementation as a drop in replacement to meet all spacecraft energy requirements with compatible 120 Vdc electrical and mechanical interface using small cell technology (18650) packaging. The 32V SuperBrick incorporates unique support features and an electrical bus bar arrangement that allows cells negative can insertion into heat sink that is compressively coupled to the battery enclosure to promote good thermal management. The housing design also provides an internal flame suppression "filter tray" and positive venting path internal to the enclosure to allow hot effluent ejecta to escape in the event of single cell TR. Virtual cells (14P Banks) that are supported to provide cell spacing with interstitial materials to prevent side can failures that can produce cell to cell TR propagation. These features were successfully test in four separate TR run with the full scale DTA1 test article in February 2016. Successfully Completed Test Objectives - Four separate TR test runs with Full-Scale DTA1 housing with Two SuperBricks, Two SuperBrick Emulators All Tests resulted in "clean" gas with less than 6 C rise at Battery vent All Tests resulted in less than 2 C temperature rise on cold-plate outlet All Tests resulted in less than 6 psi pressure rise in the battery housing Test Run 1 -One neighbor cell TR, highest remaining neighbor 139 C. Ejecta shorted to bus caused prolonged additional heating, One shorted cell did experience TR after 12 minutes, remaining cells had adequate thermal margin Test Run 2 - No cell to cell propagation, highest neighbor cell 112 C; Test Run 3 - No cell to cell propagation, highest neighbor cell 96 C; Test Run 4 - No cell to cell propagation, highest neighbor cell 101 C; Primary TR testing and analysis were completed and reviewed for endorsement by NASA Engineering and Safety Center team members. All Key Test Objectives were met and the small cell design alternative was demonstrated and selected to be a feasible drop in replacement for the MPCV Orion CM Battery for EM2 mission.

Haynes, Chuck

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries

A Case Study of View-Factor Rectification Procedures for Diffuse-Gray Radiation Enclosure Computations

The view factors which are used in diffuse-gray radiation enclosure calculations are often computed by approximate numerical integrations. These approximately calculated view factors will usually not satisfy the important physical constraints of reciprocity and closure. In this paper several view-factor rectification algorithms are reviewed and a rectification algorithm based on a least-squares numerical filtering scheme is proposed with both weighted and unweighted classes. A Monte-Carlo investigation is undertaken to study the propagation of view-factor and surface-area uncertainties into the heat transfer results of the diffuse-gray enclosure calculations. It is found that the weighted least-squares algorithm is vastly superior to the other rectification schemes for the reduction of the heat-flux sensitivities to view-factor uncertainties. In a sample problem, which has proven to be very sensitive to uncertainties in view factor, the heat transfer calculations with weighted least-squares rectified view factors are very good with an original view-factor matrix computed to only one-digit accuracy. All of the algorithms had roughly equivalent effects on the reduction in sensitivity to area uncertainty in this case study.

Robert P Taylor