Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Constraints on directionality effect of nuclear recoils in a liquid argon time projection chamber

The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils produced in a target material from the WIMP elastic scattering. The experimental identification of the direction of the WIMP-induced nuclear recoils is a crucial asset in this field, as it enables unmistakable modulation signatures for dark matter. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity in argon dual-phase time projection chambers (TPC), that are widely considered for current and future direct dark matter searches. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud. Data were taken with nuclear recoils of known directions and kinetic energy of 72 keV, which is within the range of interest for WIMP-induced signals in argon. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is $R < 1.072$ with 90 % confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reweighting simulated events using machine-learning techniques in the CMS experiment

Data analyses in particle physics rely on an accurate simulation of particle collisions and a detailed simulation of detector effects to extract physics knowledge from the recorded data. Event generators together with a GEANT -based simulation of the detectors are used to produce large samples of simulated events for analysis by the LHC experiments. These simulations come at a high computational cost, where the detector simulation and reconstruction algorithms have the largest CPU demands. This article describes how machine-learning (ML) techniques are used to reweight simulated samples obtained with a given set of parameters to samples with different parameters or samples obtained from entirely different simulation programs. The ML reweighting method avoids the need for simulating the detector response multiple times by incorporating the relevant information in a single sample through event weights. Results are presented for reweighting to model variations and higher-order calculations in simulated top quark pair production at the LHC. This ML-based reweighting is an important element of the future computing model of the CMS experiment and will facilitate precision measurements at the High-Luminosity LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $ ^{136}\mathrm Xe$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83\text {m}}\textrm{Kr}$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83\text {m}}\textrm{Kr}$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta \beta }$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

Martínez-Lema, G. [Donostia Intl. Phys. Ctr., San ↗

Multi-modal Free-moving Data Fusion (MFDF) v1.0

Multi-modal Free-moving Data Fusion (MFDF) is a python package that implements low and high-level functionality for performing qualitative and quantitative gamma-ray imaging analyses. Such analyses enable the use of gamma-ray spectrometers and/or imagers to estimate the distribution and quantity of radiological materials in an environment. Free-moving 3D imaging requires additional information about the 3D trajectory and orientation of the system, however all of these methods can be applied to 2D static gamma-ray imaging as well. The package includes methods (MLEM and MAP) for distributed source reconstruction, methods (PSL) for point source reconstruction, the ability to ingest and utilize quantitative detector response functions (for absolute analyses), and the ability to perform 3D estimation of dose-rates from quantitative reconstructions.

Joshi, Tenzing↗

radkit v1.2

The radkit software suite (python) consists of three primary libraries: stark, trajan, and curie. The trajan library provides the tools to analyze and manipulate data from lidar and inertial measurement unit (IMU) devices as well as trajectories from algorithms such as simultaneous localization and mapping (SLAM). These components allow reading and writing standard data formats, performing rigid affine transformations, discretizing three-dimensional space, and visualizing data products. The curie library comprises a standard set of object-oriented tools for radiation data and analysis in the following modules: (1) listmode and binmode data classes with methods for manipulation, plotting, slicing and file IO; (2) radiological/nuclear source detection/identification analysis results; (3) source encounters of correlated analyses and (4) energy-dependent angular detector response functions. The stark package provides low-level tools that are leveraged by both curie and trajan. The tools are flexible for offline analysis as well as performant for real-time integrations. The radkit libraries have associated Robot Operating System packages for use in real-time and robotic systems.

Joshi, Tenzing↗

RadSim: Particle Transport Wrapper

RadSim is being developed to provide the capability to simulate radiation source emissions, interpolate results from radiation transport tools into a common format to prepare incident flux, and model radiation detector response. This software package includes wrapper API code which is utilized in the development of the second (transport) task of the RadSim project. This software package only contains tools to interface RadSim with radiation transport tools (GEANT4 and MCNP) and does not include any part of the transport source code itself. The users will need prior access to the transport tools (GEANT4 and MCNP), and can use this software package to interface with the transport tool of their choice. This software package takes the geometry file for a radiation transport problem and converts it into an input deck for the transport tools (GEANT4 and MCNP). Additionally, it also contains filters that convert the output of the transport tools to a common flux format.

Cheung, Hoi Sing↗

radkit base v1.6

The radkit (base) software suite (python) consists of three primary libraries: stark, trajan, and curie. The trajan library provides the tools to analyze and manipulate data from lidar and inertial measurement unit (IMU) devices, cameras, as well as trajectories from algorithms such as simultaneous localization and mapping (SLAM). These components allow reading and writing standard data formats, performing rigid affine transformations, discretizing three-dimensional space, and visualizing data products. The curie library comprises a standard set of object-oriented tools for radiation data and analysis in the following modules: (1) listmode and binmode data classes with methods for manipulation, plotting, slicing and file IO; (2) radiological/nuclear source detection/identification analysis results; (3) source encounters of correlated analyses and (4) energy-dependent angular detector response functions. The stark package provides low-level tools that are leveraged by both curie and trajan. The tools are flexible for offline analysis as well as performant for real-time integrations.

Salathe, Marco [Lawrence Berkeley National Laborat↗

Space to Air High-Altitude Region Adjoint Neutron Transport

Neutrons from an atmospheric nuclear explosion can be detected by sensors in orbit. Current tools for characterizing the neutron energy spectrum assume a known source and use forward transport to recreate the detector response. In realistic scenarios the true source is unknown, making this an inefficient, iterative approach. In contrast, the adjoint approach directly solves for the source spectrum, enabling source reconstruction. The time–energy fluence at the satellite and adjoint transport equation allow a Monte Carlo method to characterize the neutron source’s energy spectrum directly in a new model: the Space to High-Altitude Region Adjoint (SAHARA) model. A new adjoint source event estimator was developed in SAHARA to find feasible solutions to the neutron transport problem given the constraints of the adjoint environment. This work explores SAHARA’s development and performance for mono-energetic and continuous neutron energy sources. In general, the identified spectra were shifted towards energies approximately 5% lower than the true source spectra, but SAHARA was able to capture the correct spectral shapes. Continuous energy sources, including real-world sources Fat Man and Little Boy, resulted in identifiable spectra that could have been produced by the same distribution as the true sources as demonstrated by two-dimensional (2D) Kolmogorov–Smirnov tests.

LaMere, Zachary W.↗

Constraining Absolute Higgs Couplings using Vector Boson Fusion H to WW with FCC-hh

The absolute normalisation scale of Higgs couplings is difficult to determine in hadron colliders. An experimentally and theoretically clean way to establish the coupling scale is to measure the ratio of resonant Vector Boson Fusion $H \rightarrow WW^{*}$ production to non-resonant $qq \rightarrow qqWW$ because both the theoretical and detector response systematics all cancel to first order in the ratio. To set the scale of the sensitivity, a simple selection and fit is presented with gives a 1.8\% (1.9\%) statistical uncertainty on the ratio for a 100 (84) TeV FCC-hh at 30\,ab$^{-1}$, which would give a corresponding uncertainty on the $\kappa$ scale of 0.5-1\% depending on systematic effects and potential impacts of more sophisticated analysis.

Lipeles, Elliot [University of Pennsylvania] (ORCI↗

Search for low mass WIMP dark matter with DarkSide-50

DarkSide-50 is a direct dark matter detection experiment at Laboratori Nazionali del Gran Sasso that uses argon as the target material. Exploiting the ionization signal from a dual-phase time projection chamber filled with low-radioactivity argon, it has set the most stringent exclusion limit on WIMPs with a mass of few \mathrm{GeV}/c^2 G e V / c 2 . A new analysis has recently been carried out with a larger exposure, profiting from an improved understanding of the detector response and background model. An improvement of about a factor 10 in sensitivity is expected for a WIMP mass of 2 GeV/c ^2 2 .

Kimura, Masato↗

Dose Calculations from Source Models and Gamma-Ray Spectra

Gamma-ray dose rates computed by two radiation source model-based methods and five measured spectrum-based methods are compared. With the exception of a Detective DX-100, which reported dose rates that are about 25% less than the mean, dose rates are generally within 10% of mean values. Methods for computation of dose rates employed by the Gamma Detector Response and Analysis Software (GADRAS) are described and critically evaluated. Results are presented for a feasibility evaluation that seeks to use spectra recorded inside vehicles to estimate the minimum dose outside the vehicles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrated Data Analysis to Improve Te and Zeff Measurement on NSTX-U

The multi-energy soft x-ray (ME-SXR) camera is a new concept for a fusion plasma diagnostic based on a pixelated detector with adjustable photon cutoff thresholds. It is a single, compact, solid-state detector which combines spatial and spectral sensitivity and can be configured remotely at run time, making it ideal for a fusion environment. The detector can be configured for application to a wide range of physics problems including impurity transport, electron temperature profiles, and non-thermal effects. The detector has been installed on the Madison Symmetric Torus (MST) as part of a collaboration between Princeton Plasma Physics Laboratory and the University of Wisconsin–Madison to develop the technology and analysis techniques. A full diagnostic forward model of the ME-SXR diagnostic has been developed to enable analysis of the raw photon count data. This model incorporates the atomic physics underlying the plasma emission, diagnostic geometry, and detector response characteristics. Employing this model, a Bayesian analysis approach is used to extract electron temperature from the raw data. This analysis approach uses all available information, clearly quantifies prior information, and handles uncertainties transparently. The ME-SXR camera is being used to study the 3D (helical, stellarator-like) state that forms in the MST device. This helical core structure has improved energy confinement. The transition to the helical state is accompanied by a rise in electron temperature in the central part of the helical structure, but then this enhancement fluctuates. The characteristics of this fluctuation are being compared to a magneto-hydrodynamics model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subcritical Multiplication Ex-Core Calculations with Shift

This report details the development and testing of Virtual Environment for Reactor Applications (VERA) as applied to full core subcritical multiplication ex-core calculations with Shift. The limiting factor in being able to run these detector calculations with Monte Carlo is the amount of computational memory used by a fully-loaded full core problem. The main development features added to VERA in this effort were enabling source biasing and separable weight windows and integrating multithreading in Shift. With these capabilities, a subcritical multiplication detector response calculation on a full core Watts Bar Nuclear Plant Unit 1 (WBN1) ex-core model was successfully run on a moderately sized computing cluster.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a High-Energy Neutron Sniffer and Subsequent Dose Quantification for High-Energy Particle Accelerator Shielding Surveys

The objective of this research is to design a portable neutron detector that is lightweight and responds to neutrons with energies of 20 MeV and greater. The instrument will be used as a ‘sniffer’ probe for identifying shielding weaknesses at high-energy particle accelerators and be paired with a plastic scintillator to quantify the high-energy neutron dose equivalent. The sniffer probes are two different sizes and comprised of either cesium iodide or sodium iodide, all doped with thallium, making a total of four detectors. The probes were calibrated to respond only to radiations with 8 MeV electron equivalent energy or higher, vastly reducing detector response from background and lower energy radiations. The sniffer probes were tested using californium- 252 and americium-beryllium sources, followed by high-energy (up to 800 MeV) neutron exposures at the Los Alamos Neutron Science Center Weapons Neutron Research (WNR) facility. The sniffer probes were then used to identify areas around the accelerator facility where elevated levels of high-energy radiation was present and the plastic scintillators were placed in these locations to determine the high-energy neutron dose equivalent. The dose equivalent is calculated by measuring the 12 C(n,2n) 11 C reaction, which has a 20.4 MeV neutron threshold. Two locations behind the WNR facility were identified with the probes and the dose equivalent rates from neutron energies above 20 MeV were calculated to be 1.24 mrem/h behind flightpath 30-left and 1.53 behind flightpath 30-right. Of the four sniffer probes, the 2-inch x 2-inch cesium iodide is the recommended probe for performing high-energy shielding surveys. The larger crystal size yields higher sensitivity at lower count rates and the more dense material increases the likelihood of interaction within the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time data reduction at 100 Tbps: Challenge and opportunity for AI-based data reduction for next-generation large-scale nuclear physics collider experiment

The modern large-scale nuclear physics (NP) experiments in high-energy particle colliders utilize streaming-readout electronics to digitize detector response at O(100) Tbps bandwidth. Prominent examples at Brookhaven National Lab (BNL) include the sPHENIX experiment at Relativistic Heavy Ion Collider (RHIC), which is under construction, and the experiments proposed for the Electron-Ion Collider (EIC), planned for the 2030s . One of the main challenges for these streaming readout systems is to manage the data rate with sufficient data reduction in real time so the end-data fit persistent storage for offline analysis, which is typically at O(1000) times smaller and O(100) Gbps. Such data reduction traditionally is achieved via real-time high level triggers, which select and save a small subset of collisions of interest. Although triggering is applicable to high energy collider experiments such as those at the Large Hardron Collider at CERN, it is insufficient for these nuclear physics experiments which study diverse collision topologies. And traditional triggering approach is inefficient to preserve the max information harvested from the operation of colliders that costs O(100)M per year to DOE. Meanwhile, in recent years, ML-based high-throughput data reduction has emerged as a promising approach to efficiently preserve max information for a given space of persistent storage, e.g. via AI data compression, feature extraction, and noise filtering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗