Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fouling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Slippery Omniphobic Covalently Attached Liquids for Extreme Anti-Scaling

Fouling is amajor unresolved problem in a varietyof industries including power generation, water desalination,and hydrometallurgy. In a heat exchanger, the accumulated salt scale could lead to a decrease in heat transfer, corrosion, blockage of flow and increasedpressure drop, resulting in higher operation costsand shortened equipment lifetime. The added operational costs due to active scale removal techniques such as mechanical abrasion and chemical inhibitors are responsible for 0.25% of the GDP in industrialized nations.Herewe utilize slippery omniphobic covalently attached liquids (SOCAL) dip coating on aluminum substrates to minimize surface energyand surface roughness, hence maximizingthe energy barrier for scale formation. To enable SOCAL surfacebinding on aluminum, we started by depositinga nanoscale(500 nm thick)adhesion layer of SiO2using scalable and cost-effective electrophoretic deposition (EPD), followed by SOCAL grafting to the SiO2.The EPD SiO2coating chemistry was tailored to achieve a smoothsurface finish which, combined with the low surface energyof the SOCAL coating, translated to extreme anti-scaling performance. Thermal degradation testing in an ambient environment revealed the covalently bonded SOCAL coatingswithstand temperatures of 100°C. To characterize scaling, we utilized CaSO4and CaCO3scale tests, showing up to 20X less scaling than uncoated aluminum. Descaling tests revealed that our SOCAL coatings dramatically decrease scale adhesion, resulting in rapid removal of scale buildup in highly supersaturated conditions. To investigate manufacturability, two alternate methods of SiO2deposition were tested, including physical vapor deposition and spin-on glass, with great success in coating smooth metallic substrates, but limited success due to the inability to coat arbitrarily shaped surfaces. Our work not only demonstrates a facile method of tailoring interfacial energy and roughness to control fouling, it develops cost-effective, scalable,and high performing anti-fouling coating applicable to aluminum surfacesfor a variety of applications.

Zhao, Hanyang↗

Cryogenic Carbon Capture Development (Final Report)

This project extends and leverages the work completed under funding from ARPA-E and other sources by exploring aspects of the Cryogenic Carbon Capture™ (CCC) process and issues discovered during those projects, but that were not within the scope or budget of previous projects or that became apparent during field tests. Our successful completion of the tasks outlined in this project has increased the reliability, efficiency, and scalability of the CCC process and we are better prepared for pilot-scale testing. The first phase of this project improved key areas of the process through iterative design and experiment, culminating with recommendations for improvements to the existing skid-scale system developed under non-federal funding. The second phase of this project implemented the improved unit operations into the Cryogenic Carbon Capture External Cooling Loop (CCC ECL™) skid and field tests the improved system at a coal-fired power plant. The specific areas of work in this project are: Budget Period 1: 1) Selection of the most energy-efficient drying system for ambient-pressure flue gas. Sustainable Energy Solutions, LLC (SES) has successfully demonstrated a dryer that removes bulk water using a low-temperature brine to remove about 99% of the water followed by a mol sieve 3A desiccant dryer to remove the remaining 1% water; 2) Selection and demonstration of efficient solution to fouling due to dissolved CO 2 . SES has tested several commercial heat exchangers that purport to be able to handle fouling issues similar to those experienced in the contact liquid chiller. Replicated tests using the CCC ECL™ skid and dimpled brazed plate heat exchangers demonstrate that quick throttling of refrigerant combined with a burst of clean gas mitigate the fouling caused by CO 2 solubility in contact liquid with only minor increases in parasitic load. SES models indicate that parasitic load would increase by approximately 0.0125 GJ/tonne, an order of magnitude less than what was determined to be the maximum allowable additional parasitic load caused by this system; 3) Selection and demonstration of efficient and scalable solid–liquid separation system. The screw press technology met or exceeded the 70% solids loading benchmark during several test runs exceeding 24 hours on the CCC ECL™ skid. The average solids loading during the entire 50-hour run was 67%. The energy demand for this system is less than 0.1 GJ e /tonne of CO 2 processed; 4) Optimize design and demonstration of patented desublimating heat exchangers. We designed and built a hybrid spray tower that was tested over many hundreds of hours and a 50-hour continuous test run was completed capturing over 0.5 tonne CO 2 /day at >90% capture; (5) Plan for safe dilution of oxygen-depleted, cleaned flue-gas stream. The AERSCREEN simulator developed by the EPA modeled the dispersion of oxygen-depleted flue gas from the CCC process at a commercial plant. The results indicate that this plan effectively mitigates the flue gas hazards; (6) Simulation of and experimental work related to multi-pollutant capture. SES programmed an upgrade to its solid/vapor/liquid equilibrium (SVLE) algorithm. This enables simultaneous modeling of multiple pollutants (i.e., CO 2 , SO x , NO x , Hg, HCl). Budget Period 2; (7) Modify the CCC ECL™ skid for field testing and complete shakedown testing. The plans for modifying the CCC ECL™ skid were finalized and put into place. Shakedown testing of the updated CCC ECL™ skid occurred at SES using closed-loop mode (i.e., using a synthetic flue gas consisting of only N 2 and CO 2 ) and at the Hunter Power Plant using flue gas from the coal-fired boiler. Shakedown testing took longer than expected due to delays in receiving equipment and unexpected equipment performance in the field; (8) Operate the CCC ECL™ skid in the field. Longer testing of the CCC ECL™ skid occurred at the Hunter Power Plant. Multiple tests exceeding 35 hours were completed, with a total of over 600 hours of CO 2 capture completed using flue gas at the Hunter Power Plant with an average CO 2 capture rate of over 91% during those hours. Extensive notes and documentation were acquired informing improved methods for controls, startup, operation, and shut down; (9) Determine figures of merit and quantify process improvement. SES defined figures of merit for unit operation performance and overall CCC ECL™ process performance. All figures of merit were achieved or surpassed, except for 500 continuous hours of demonstration at the Hunter Power Plant; (10) Complete an Environmental Health and Safety Risk assessment by a third party. Tri-State completed an Environmental Health and Safety Risk assessment; (11) Update techno-economic analysis with third-party validation. The techno-economic analysis has been completed. It confirms the potential large reduction in energy and cost of the CCC process compared with leading alternatives and that the estimates and estimation techniques are reliable.

20 FOSSIL-FUELED POWER PLANTS↗

TEAMER Technical Support on Biofouling and Corrosion for E-Wave Technologies LLC Novel (Abstract)

National Technology & Engineering Solutions of Sandia (NTESS) in collaboration with the Pacific Northwest National Laboratory (PNNL), and with guidance from E-Wave, will assess corrosion and biofouling challenges specific to E-Wave’s innovative WEC designed to retrofit into and power existing aquaculture farm infrastructure from ocean waves. The teams will examine coatings via a static raw seawater test and determine the efficacy of coatings for E-Wave’s applications. Samples will include panels of materials provided by E-Wave and coated with three different paint treatments. Fouling will be determined using a staining technique followed by photographic analysis to evaluate fouling intensity on the surface. Materials will also be weighed before and after submersion to facilitate weight change analysis resulting from fouling organisms aggregating on the materials.

16 TIDAL AND WAVE POWER↗

Water vapor diffusion membrane development

A total of 18 different membranes were procured, characterized, and tested in a modified bench-scale vapor diffusion water reclamation unit. Four membranes were selected for further studies involving membrane fouling. Emphasis was placed on the problem of flux decline due to membrane fouling. This is discussed in greater details under "Summary and Discussion on Membrane Fouling Studies" presented in pages 47-51. The system was also investigated for low temperature application on wash-water where the permeated water is not recovered but vented into space vacuum.

Tan, M. K.↗

Design optimization of a brush turbine with a cleaner/water based solution

Recently, a fluid turbine which has a brush attached to it has been designed and tested with water as fluid. The purpose of the turbine-brush is to clean up fouling in a tube. The Montreal Protocol prohibits the use of CFC products from refrigeration industry or from industry in general as a cleanser in 1996. Alternatives for the cleansers, devices or a combination of alternative devices with a cleanser should be found. One of the methods is to develop a device which cleans fouling with a cleaning medium. In this paper, we describe a turbine connected with a brush. However, the turbine with the brush should be simple and easy to install. This device is a combined small liquid turbine with a brush. The turbine is activated by the liquid flowing through the tube. Then the turbine turns the brush cleaning fouling along the tube. Based on the energy conservation and the Bernoulli equation along with an empirical relationship of drag force obtained from an experimental apparatus, a relationship of the rotational speed, the number of blades, and geometric variables of the turbine-brush was obtained. The predicted rotational speeds were compared with the experimental observations. Further work was recommended for improvements.

Kim, Rhyn H.↗

Self-Cleaning Boudouard Reactor for Full Oxygen Recovery from CO2 Project

Oxygen recovery from respiratory CO2 is an important aspect of human spaceflight. Methods exist to sequester the CO2, but production of oxygen needs further development. The current ISS Carbon Dioxide Reduction System (CRS) uses the Sabatier reaction to produce water (and ultimately breathing air). Oxygen recovery is limited to 50% because half of the hydrogen used in the Sabatier reactor is lost as methane, which is vented overboard. The Bosch reaction is the only real alternative to the Sabatier reaction, but in the last reaction in the cycle (Boudouard) the resulting carbon buildup will eventually foul the nickel or iron catalyst, reducing reactor life and increasing consumables. To minimize this fouling, find a use for this waste product, and increase efficiency, we propose testing various self-cleaning catalyst designs in an existing MSFC Boudouard reaction test bed and to determine which one is the most reliable in conversion and lack of fouling. Challenges include mechanical reliability of the cleaning method and maintaining high conversion efficiency with lower catalyst surface area. The above chemical reactions are well understood, but planned implementations are novel (TRL 2) and haven't been investigated at any level.

Technology Portfolio System↗

Finding Balance Between Biological Groundwater Treatment and Treated Injection Water

At the U.S. Department of Energy’s Hanford Site, CH2M HILL Plateau Remediation Company operates the 200 West Pump and Treat which was engineered to treat radiological and chemical contaminants in groundwater as a result of the site’s former plutonium production years. Fluidized bed bioreactors (FBRs) are used to remove nitrate, metals, and volatile organic compounds. Increasing nitrate concentrations in the treatment plant effluent and the presence of a slimy biomass (a typical microorganism response to stress) in the FBRs triggered an investigation of nutrient levels in the system. Little, if any, micronutrient feed was coming into the bioreactors. Additionally, carbon substrate (used to promote biological growth) was passing through to the injection wells, causing biological fouling of the wells and reduced specific injectivity. Adjustments to the micronutrient feed improved microorganism health, but the micronutrients were being overfed (particularly manganese) plugging the injection wells further. Injection well rehabilitation to restore specific injectivity required repeated treatments to remove the biological fouling and precipitated metal oxides. A combination of sulfamic and citric acids worked well to dissolve metal oxides and sodium hypochlorite effectively removed the biological growth. Intensive surging and development techniques successfully removed clogging material from the injection wells. Ultimately, the investigation and nutrient adjustments took months to restore proper balance to the microbial system and over a year to stabilize injection well capacities. Carefully tracking and managing the FBRs and well performance monitoring are critical to balancing the needs of the treatment system while reducing fouling mechanisms in the injection wells.

Carlson, Mark A.↗

Complex Microfiltration Behavior of Metal Hydroxide Slurries

Crossflow filtration is to be a key process in the treatment and disposal of approximately 60,000 metric tons of high-level waste stored at the Hanford Site in Richland, Washington. Pacific Northwest National Laboratory is assessing filter performance against waste simulant materials that mimic the chemical and physical properties of Hanford tank waste. Prior simulant studies indicate that waste filtration performance may be limited by pore and cake fouling. To limit the shutdown of waste treatment operations, the pre-treatment facility plans to recover filter flux loses from cake formation and filter fouling by frequently backpulsing the filter elements. The objective of the current research is to develop an understanding of the roles of cake and pore fouling and potential flux recovery through backpulsing of the filters for Hanford waste filtration operations. Metal hydroxide wastes were tested to examine the role of particle-filter interaction on filter performance.

Hanford Site↗

Curable polysiloxane compositions and slippery materials and coatings and articles made therefrom

The present teachings generally provide curable polysiloxane compositions including a base resin including a MQ vinyl siloxane. Articles of manufacture including the curable polysiloxane compositions and slippery coatings and materials also are provided. The compositions may be used to provide slippery, lubricious, or repellent materials and coatings and may provide anti-fouling function. The compositions can provide anti-fouling or foul-release function on open surfaces, internal surfaces, membranes; to provide pinning free or low contact angle hysteresis surfaces; to provide homogeneous interface to suppress nucleation; to provide a barrier layer such as anti-corrosion; to provide anti-stain, anti-smudge, anti-fingerprint, anti-soil function.

Kim, Philseok↗

Apparatus and method for intrachannel defouling of a heat exchanger using induction heaters

An apparatus comprising a heat exchanger and one or more induction heating elements is disclosed. The heat exchanger comprises a coolant side conduit and a process side conduit, the process side conduit being susceptible to fouling by at least partial desublimation, condensation, crystallization, deposition, or combinations thereof of a fouling component of a circulating process fluid. An electrically conductive first metal is disposed adjacent to the process side conduit. The one or more induction heating elements are disposed proximate to the heat exchanger. The one or more induction heating elements are connected to a source of electrical current. When the electrical current flows through the induction heating elements, eddy currents are induced in the first metal, heating the first metal such that the fouling component sublimates, melts, absorbs, or a combination thereof into the circulating process fluid.

42 ENGINEERING↗

Curable polysiloxane compositions and slippery materials and coatings and articles made therefrom

The present teachings generally provide curable polysiloxane compositions including a base resin including a surface active polymer. Articles of manufacture including the curable polysiloxane compositions and slippery coatings and materials also are provided. The compositions may be used to provide slippery, lubricious, or repellent materials and coatings and may provide anti-fouling function. The compositions can provide anti-fouling or foul-release function on open surfaces, internal surfaces, membranes; to provide pinning free or low contact angle hysteresis surfaces; to provide homogeneous interface to suppress nucleation; to provide a barrier layer such as anti-corrosion; to provide anti-stain, anti-smudge, anti-fingerprint, anti-soil function.

Kim, Philseok↗

Curable polysiloxane compositions and slippery materials and coatings and articles made therefrom

The present teachings generally provide curable polysiloxane compositions including a base resin including a surface active polymer. Articles of manufacture including the curable polysiloxane compositions and slippery coatings and materials also are provided. The compositions may be used to provide slippery, lubricious, or repellent materials and coatings and may provide anti-fouling function. The compositions can provide anti-fouling or foul-release function on open surfaces, internal surfaces, membranes; to provide pinning free or low contact angle hysteresis surfaces; to provide homogeneous interface to suppress nucleation; to provide a barrier layer such as anti-corrosion; to provide anti-stain, anti-smudge, anti-fingerprint, anti-soil function.

Kim, Philseok↗

Biofilm monitoring using complex permittivity.

There is strong interest in the detection and monitoring of bio-fouling. Bio-fouling problems are common in numerous water treatments systems, medical and dental apparatus and food processing equipment. Current bio-fouling control protocols are time consuming and costly. New early detection techniques to monitor bio-forming contaminates are means to enhanced efficiency. Understanding the unique dielectric properties of biofilm development, colony forming bacteria and nutrient background will provide a basis to the effectiveness of controlling or preventing biofilm growth. Dielectric spectroscopy measurements provide values of complex permittivity, {var_epsilon}*, of biofilm formation by applying a weak alternating electric field at various frequencies. The dielectric characteristic of the biofilm, {var_epsilon}{prime}, is the real component of {var_epsilon}* and measures the biofilm's unique ability to store energy. Graphically observed dependencies of {var_epsilon}{prime} to frequency indicate dielectric relaxation or dielectric dispersion behaviors that mark the particular stage of progression during the development of biofilms. In contrast, any frequency dependency of the imaginary component, {var_epsilon}{double_prime} the loss factor, is expressed as dielectric losses from the biofilm due to dipole relaxation. The tangent angle of these two component vectors is the ratio of the imaginary component to the real component, {var_epsilon}{double_prime}/{var_epsilon}{prime} and is referred to as the loss angle tangent (tan {delta}) or dielectric loss. Changes in tan {delta} are characteristic of changes in dielectric losses during various developmental stages of the films. Permittivity scans in the above figure are of biofilm growth from P. Fluorescens (10e7 CFU's at the start). Three trends are apparent from these scans, the first being a small drop in the imaginary permittivity over a 7 hours period, best seen in the Cole-Cole plot (a). The second trend is observed two hours after inoculation when the permittivity begins to increase slightly over the next 20 hours, best seen in the shift from 1000 Hz to 5000 Hz in tan {delta} at the high frequencies (c). Because of similar dielectric relaxation properties noted by the comparable size of the semicircles, plot (a), and the height of tan {delta}, plot (c), within the first 29 hours, cell activity levels did not appreciably change. The third trend is observed when the complex permittivity value drops by orders of magnitude between 29 hours and 37 hours, best seen in the log [E] plot (b), and in the drop of the dielectric loss, tan {delta}, to 0. This change in the dielectric properties in the bio environment is nearly independent of all frequencies (c) and dissimilar from the original condition when only bacteria and nutrient was present in the biofilm chambers. The semicircles in plot (a) for this period decreased below the resolution of the graph, implying a large difference in the dielectric behavior of the cells/biofilms consisting of low dielectric losses. We believe these large changes are related to the on-set of biofilms.

36 MATERIALS SCIENCE↗

Nanofiltration/reverse osmosis for treatment of coproduced waters

Current high oil and gas prices have lead to renewed interest in exploration of nonconventional energy sources such as coal bed methane, tar sand, and oil shale. However oil and gas production from these nonconventional sources has lead to the coproduction of large quantities of produced water. While produced water is a waste product from oil and gas exploration it is a very valuable natural resource in the arid Western United States. Thus treated produced water could be a valuable new source of water. Commercially available nanofiltration and low pressure reverse osmosis membranes have been used to treat three produced waters. The results obtained here indicate that the permeate could be put to beneficial uses such as crop and livestock watering. However minimizing membrane fouling will be essential for the development of a practical process. Field Emission Scanning Electron Microscopy imaging may be used to observe membrane fouling.

01 COAL, LIGNITE, AND PEAT↗

Advancements in conventional and 3D printed feed spacers in membrane modules

Plate & frame and spiral-wound modules are used for gas separation, pervaporation, reverse osmosis, nanofiltration, ultrafiltration, microfiltration, electro-dialysis, electro-deionization, membrane distillation and forward osmosis membrane processes. Feed channel spacers are an integral part of both module types – providing mechanical support for a cross-flow channel through the module and, in most cases, promoting mixing to enhance mass transfer to reduce concentration polarization and fouling. However, enhanced mass transfer comes at a cost of increased hydraulic pressure losses and stagnant zones wherever a spacer filament touches a membrane surface. Further, these stagnant zones exacerbate membrane fouling and make cleaning more difficult. Efforts to improve feed spacer performance largely focus on adjusting the chemistry or geometry of the spacer to mitigate these challenges. Additive manufacturing (i.e. 3D printing) offers new degrees of freedom in feed spacer design and production, which opens up a new area of research in membrane technology. This review critically assesses the peer-reviewed literature on conventional net- or mesh-style feed spacers in addition to various novel spacer geometries and chemistries produced via 3D printing. We further review and evaluate conventional spacer manufacturing methods and discuss advantages and disadvantages of 3D printed spacers.

3D printing↗

Reactive transport modeling of the Aquifer Thermal Energy Storage (ATES) system at Stockton University, New Jersey during seasonal operations

Hydrogeochemical processes associated with Aquifer Thermal Energy Storage (ATES) operations can often impact the system performance owing to mineral precipitation either at the wellbore or in the aquifer owing to changes in temperature and fluid disequilibria. Although failure of ATES systems due to mineral precipitation ("fouling") is common, predictive reactive-transport models have rarely been applied to plan their design and operation. Here, the objective of this study is to develop a reactive-transport model by coupling thermal, hydrological, and chemical (THC) processes to evaluate effects of introduced atmospheric oxygen on water chemistry, mineral precipitation/dissolution, porosity, and permeability changes associated with an ATES system at Stockton University (New Jersey, USA). The THC model builds on a Thermal-Hydrological-Mechanical (THM) model of the site that evaluated system failure owing to possible fracturing in the caprock or around the wellbore. The causes of the system failure are not known – potential causes include hydraulic fracturing owing to elevated pump pressures that took place, a flow pathway created by one of the boreholes, or a pre-existing natural hydrologic connection between the upper unconfined aquifer and the ATES aquifer, any of which could have led to oxygenated water entering the reservoir and causing the observed Fe-oxide fouling on well screens. The THC model is used to evaluate some of the hypotheses and observations regarding system failure owing to geochemical processes. The reactive-transport code TOUGHREACT V4 was used to model the THC processes during seasonal heating and cooling operations at the Stockton ATES site over 6 years of operation. In the THC simulations, the primary effects on geochemistry were observed when the injection water is saturated with atmospheric oxygen. Simulations show greater precipitation of goethite near the cold wells as compared to the warm wells. Although volume fractions of Fe-hydroxides were relatively small, the model was aimed at processes in the aquifer at the scale of meters and larger rather than at the scale of mm or cm (i.e., a well screen). Kaolinite is the dominant precipitating phase, also around the cold wells. Illite dissolves near the cold wells and precipitates near the warm wells. There is a net decrease in the porosity near the cold wells and increase near the warm wells, although a slight amount of thermal contraction near the cold wells and expansion near the warm wells is responsible for a significant proportion of the porosity change. Owing to the coarse discretization of the numerical grid near the wells (compared to the screen thickness) the magnitude of permeability changes at the wellbore are likely underestimated. The reactive transport model in this study can be used for characterization of aquifers, optimizing the operational parameters (temperature, pressure, pH etc.), and planning of mitigation strategies for ATES systems.

15 GEOTHERMAL ENERGY↗

Experimental investigation on the coolability of nuclear reactor debris beds using seawater

During the Fukushima nuclear reactor accident, seawater was injected into the reactor core to cool the decay heat from the heat generating porous debris bed. However, the impact of dissolved salts in water on the coolability of a debris bed is not well understood. This paper is one of the first works to investigate the cooling mechanisms for debris bed using seawater. An experimental system was built where the packed bed test section was volumetrically heated via a high frequency induction heater. The temperature along the axis of the test section was measured using a high resolution temperature sensor based on Optical Frequency Domain Reflectometry. Experimental results show that the dryout heat flux increases with an increase in concentration, with pure water having a dryout volumetric heat flux of 1.8 MW/m and salt water of concentration 7% having a dryout volumetric heat flux of 2.8 MW/m. However, this enhanced coolability using salt water is short term, as the crystallization fouling mechanism becomes significant over time and leads to gradual temperature excursion in the bed. The fouling mechanism eventually leads to a cross section of the debris bed to plug with the deposited salts, and this leads to a pressure build up in the lower regions of the debris bed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Orientation matters: Measuring the correct surface of polyamide membranes with quartz crystal microbalance

The surface of polyamide reverse osmosis (RO) membranes which regulates interface-dominated phenomena, such as partitioning and fouling, is the one facing the feed during operation. However, the opposite surface of the polyamide selective layer, the one facing the permeate and in contact with the polysulfone porous support, is commonly analyzed in quartz crystal microbalance (QCM) measurements due to limitations of state-of-the-art transfer methodologies. Such measurements on the back surface cannot be generalized because the polyamide layer is chemically and morphologically asymmetric. Herein, we introduce a simple method to coat QCM sensors with polyamide active layers in the correct orientation (i.e., exposing their front surface) and show that interface-dominated phenomena differ significantly between orientations. We start by describing a transfer protocol to coat any surface with a polyamide layer on its front surface orientation. We then systematically analyze the chemical and morphological differences between the two surfaces of the polyamide layer of a commercial RO membrane. Finally, we demonstrate that interface-dominated phenomena depend on the orientation by showing that NaCl partitioning at pH 6 was 1.3 to 2.3-fold higher on the front surface and that organic fouling with humic acid occurred at a lower rate on this surface. The new method presented herein enables measurements on the front surface of polyamide RO membranes, which should be the standard in any future QCM studies.

Fouling behavior↗