Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings

System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear

Huang, Sen↗

Energy savings and life cycle cost analysis of advanced double skin facade system applied to old apartments in South Korea

South Korea is one of the most densely populated countries in the world, and the population density in urban areas is much higher among others. Apartments are the most common form of residential buildings due to their high population density. More than 60% of domestic residential buildings are apartments, with more than 10 million households. The high population density is a problem that has long plagued South Korea because more than 45% of apartments are old apartments that are more than 20 years old. Old apartment buildings have low thermal performance that results in lots of energy consumption. Balconies, which worked as a thermal buffer, are also being removed by residents to expand indoor space. According to the green remodeling project supported by the Korean government, the typical retrofitting method is replacing external windows with the high-efficiency window in old apartments in South Korea. Here, this paper proposes a retrofitting method using an extended double-skin façade (DSF) system that replaces exterior windows and acts as a thermal buffer. The simulation model is developed with the EnergyPlus simulation program to conduct energy performance analyses. The simulation model has been calibrated using actual experimental data collected between October 1, 2019, and January 15, 2020. Results show that the cooling, heating, and lighting energy can be reduced up to 44.1% by fully utilizing electric energy generated by solar PV panels integrated with the DSF system. The payback period is about 15 years based on the energy price provided by the utility company. Although the payback period is long, it has great potential of energy savings and CO 2 emission reductions. The DSF system should be considered as a way of renovation, considering other factors such as increased real estate values and energy cost increases in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of window scheduler algorithm exploiting natural ventilation and thermal mass for building energy simulation and smart home controls

Building energy simulations often rely on abstract assumptions when it comes to natural ventilation, such as ‘windows always open [or closed]’ or ‘windows open when outdoor temperature is below a certain threshold.’ However, simulations based on these assumptions fail to fully exploit the cooling potential of natural ventilation, as its effectiveness can be enhanced or diminished by various factors, including the presence of thermal mass. This issue also extends to smart home controls, where determining the window schedule becomes challenging without information about the building's response to outdoor conditions. To address these issues, this study has developed an analytical model for window operation schedules that leverages the passive cooling from natural ventilation. The analytical model was validated against a Modelica simulation. A case study utilizing the BESTEST model of ANSI/ASHRAE Standard 140 underwent validation with EnergyPlus simulations, showing strong concordance. The algorithm provides window schedule recommendations adapted to various airflow rates, thermal masses, and climate variations. Notably, the case study demonstrated that proper window scheduling could reduce indoor temperature by up to 8 °C under the given simulation settings, thereby improving resilience and indicating potential energy savings. Furthermore, the paper explores the potential opportunities and challenges this approach presents, especially for building simulation and smart home applications.

42 ENGINEERING↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study

This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.

CO 2 GSHP↗

Examination of the technical potential of near-infrared switching thermochromic windows for commercial building applications

Current thermochromic windows modulate solar transmission primarily within the visible range, resulting in reduced space-conditioning energy use but also reduced daylight, thereby increasing lighting energy use compared to conventional static, near-infrared selective, low-emittance windows. To better understand the energy savings potential of improved thermochromic devices, a hypothetical near-infrared switching thermochromic glazing was defined based on guidelines provided by the material science community. In this paper, EnergyPlus simulations were conducted on a prototypical large office building and a detailed analysis was performed showing the progression from switching characteristics to net window heat flow and perimeter zone loads and then to perimeter zone heating, ventilation, and air-conditioning (HVAC) and lighting energy use for a mixed hot/cold climate and a hot, humid climate in the US. When a relatively high daylight transmission is maintained when switched (Tsol=0.10–0.50 and Tvis=0.30–0.60) and if coupled with a low-e inboard glazing layer (e=0.04), the hypothetical thermochromic window with a low critical switching temperature range (14–20 °C) achieved reductions in total site annual energy use of 14.0–21.1 kW h/m2-floor-yr or 12–14% for moderate- to large-area windows (WWR≥0.30) in Chicago and 9.8–18.6 kW h/m 2 -floor-yr or 10–17% for WWR≥0.45 in Houston compared to an unshaded spectrally-selective, low-e window (window E1) in south-, east-, and west-facing perimeter zones. Finally, if this hypothetical thermochromic window can be offered at costs that are competitive to conventional low-e windows and meet esthetic requirements defined by the building industry and end users, then the technology is likely to be a viable energy-efficiency option for internal load dominated commercial buildings.

14 SOLAR ENERGY↗

Typical and extreme weather datasets for studying the resilience of buildings to climate change and heatwaves

We present unprecedented datasets of current and future projected weather files for building simulations in 15 major cities distributed across 10 climate zones worldwide. The datasets include ambient air temperature, relative humidity, atmospheric pressure, direct and diffuse solar irradiance, and wind speed at hourly resolution, which are essential climate elements needed to undertake building simulations. The datasets contain typical and extreme weather years in the EnergyPlus weather file (EPW) format and multiyear projections in comma-separated value (CSV) format for three periods: historical (2001–2020), future mid-term (2041–2060), and future long-term (2081–2100). The datasets were generated from projections of one regional climate model, which were bias-corrected using multiyear observational data for each city. The methodology used makes the datasets among the first to incorporate complex changes in the future climate for the frequency, duration, and magnitude of extreme temperatures. These datasets, created within the IEA EBC Annex 80 “Resilient Cooling for Buildings”, are ready to be used for different types of building adaptation and resilience studies to climate change and heatwaves.

54 ENVIRONMENTAL SCIENCES↗

Issues in Bi-Directional Interoperability between BIM and BEM

The state-of-the-art interoperability between Building Information Modeling (BIM) and Building Energy Modeling (BEM) is mainly one-way. BEM software like EnergyPlus takes design input from BIM and simulates the energy consumption of the building. BIM, however, is unable to leverage energy simulation results from BEM smoothly. This lack of bi-directional interoperability between BIM and BEM prevents buildings from seeking more energy-efficient design options and limits BIM applications in optimal generative design. In this research, the authors have conducted the following activities related to two-way interoperability between BIM and BEM: (1) surveyed its current status through literature review, (2) investigated barriers to the bi-directional interoperability, and (3) suggested possible approaches to enable bi-directional interoperability and research outlook in the field. As a result, the authors have identified three main barriers to BIM BEM interoperability, namely, inefficient collaboration, limited scope in information transformation, and lack of BEM to BIM transformation. Future directions are suggested to address these barriers.

building design↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Evaluation of calibration efficacy under different levels of uncertainty

This study examines how calibration performs under different levels of uncertainty in model input data. It specifically assesses the efficacy of Bayesian calibration to enhance the reliability of EnergyPlus model predictions. A Bayesian approach can be used to update uncertain values of parameters, given measured energy-use data, and to quantify the associated uncertainty.We assess the efficacy of Bayesian calibration under a controlled virtual-reality setup, which enables rigorous validation of the accuracy of calibration results in terms of both calibrated parameter values and model predictions. Case studies demonstrate the performance of Bayesian calibration of base models developed from audit data with differing levels of detail in building design, usage, and operation.

97 MATHEMATICS AND COMPUTING↗

Energy savings modelling of re-tuning energy conservation measures in large office buildings

Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS’s capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This paper investigates the energy savings potential of several common HVAC system re-tuning measures on a typical large office building, using the Department of Energy’s building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply-air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated – each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All the individual measures and combinations were simulated in 16 climate locations representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual total HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy savings for most cities for all measures). Combining many of the re-tuning measures revealed deep savings potential. Some of the more aggressive combinations revealed 35-75% reductions in annual HVAC energy consumption, depending on climate and building vintage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A high-fidelity building performance simulation test bed for the development and evaluation of advanced controls

We present an open-source building performance simulation test bed, the Advanced Controls Test Bed (ACTB), that interfaces high-fidelity Spawn of EnergyPlus building models, with advanced controllers implemented in Python. Additionally, the ACTB leverages the Building Optimization Testing and Alfalfa platforms for managing simulations, providing an external clock, a representational state transfer (REST) application programming interface (API), and key performance indicators for evaluating the effectiveness of control strategies. The REST API allows the development of external controllers programmed in languages such as Python, which provides flexibility and a rich choice of scientific libraries for designing control sequences. We present three test cases based on the U.S. Department of Energy's Reference Small Office Building to demonstrate the ACTB's capabilities: (a) rule-based controls compliant with ASHRAE Guideline 36 control sequences; (b) an economic model predictive control implemented using do-mpc; and (c) a deep Q-network reinforcement learning agent implemented using OpenAI Gym.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MCP-enabled agentic AI workflow for building energy modelling: framework and use cases

Traditional building energy modelling workflows remain labor-intensive and error-prone, requiring specialized expertise that limits broader adoption. This paper introduces a novel Model Context Protocol (MCP)-enabled framework that connects AI assistants to EnergyPlus through MCP, a standardized interface for tool invocation and context management. Two complementary integration paradigms are presented and compared: conversational integration, where users interact through natural language while an AI assistant orchestrates MCP tools on demand, and agentic workflow integration, where specialized agents coordinate autonomously to complete multi-step tasks. Using an experimental testbed for residential buildings, the end-to-end workflows are demonstrated. The conversational approach reduced typical inspection and modification tasks from 1-2 h to under 15 min, while maintaining full transparency through visible tool invocations. The agentic approach automated parametric analysis. These demonstrations establish MCP as a foundational layer for AI-assisted building energy modelling, enabling natural language interactions with simulation tools while preserving professional oversight and decision-making authority.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-scenario Extreme Weather Simulator application to heat waves: Ko’olauloa community resilience hub

Heat waves are increasing in severity, duration, and frequency. The Multi-Scenario Extreme Weather Simulator (MEWS) models this using historical data, climate model outputs, and heat wave multipliers. In this study, MEWS is applied for planning of a community resilience hub in Hau'ula, Hawaii. The hub will have normal operations and resilience operations modes. Both these modes were modeled using EnergyPlus. The resilience operations mode includes cutting off air conditioning for many spaces to decrease power requirements during emergencies. Results were simulated for 300 future weather files generated by MEWS for 2020, 2040, 2060, and 2080. Shared socioeconomic pathways 2-4.5, 3-7.0 and 5-8.5 were used. The resilience operations mode results show two to six times increase of hours of exceedance beyond 32.2 °C from present conditions, depending on climate scenario and future year. The resulting decrease in thermal resilience enables an average decrease of energy use intensity of 26% with little sensitivity to climate change. The decreased thermal resilience predicted in the future is undesirable, but was not severe enough to require a more energy-intensive resilience mode. Instead, planning is needed to assure vulnerable individuals are given prioritized access to air-conditioned parts of the hub if worst-case heat waves occur.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Evaluation of Occupancy-Aware Model Predictive Control for Residential Building Energy Efficiency and Occupant Comfort

The residential sector accounts for 25% of global primary energy consumption. Two methods have previously been proposed to reduce residential energy use associated with the provision of occupant thermal comfort: 1. Occupancy-based HVAC control, operating systems only during confirmed occupancy, and 2. model predictive control (MPC), harnessing a mathematical model and forecasts to find optimal operating strategies. Previous studies estimate the average energy savings of the two methods individually in the range of 21% and 16%, respectively. The research presented herein was carried out to evaluate the energy savings potential in residential buildings by combining both approaches across different climates, house vintages, and occupancy patterns. Occupancy and eight different physical modalities (e.g. CO2 and VOC) data were collected from five homes for time periods of 4–9 weeks. Collected data sets were used to train occupancy prediction models suggested by an extensive literature survey of occupancy model types. The trained prediction models were combined with MPC and detailed EnergyPlus building simulation models to evaluate residential building performance in terms of annual energy savings and thermal comfort, along with discomfort exceedance metrics. Multiple home types and regions were analyzed to understand regional and climate-dependent potential. Based on actual field data, the occupancy models had a prediction inaccuracy between 8% and 35% across the investigated homes. Average occupancy for the collected data ranged from 56% to 86%, a typical range reported in the literature. Building simulations were conducted for three control scenarios: conventional thermostatic control, occupancy-based, and occupancy-based MPC. The results indicate that all advanced strategies improve upon the conventional control, with some scenarios cutting energy use in half with only occasional incurrence of discomfort. The findings indicate that occupancy-aware model predictive residential building control has the potential to drastically reduce energy use and associated emissions while maintaining occupant comfort for both new and existing buildings.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A Data-Driven Approach to Nation-Scale Building Energy Modeling

In 2019, 125 million U.S. residential and commercial buildings consumed $412 billion in energy bills. These buildings currently consume 40% of the nation's primary energy, 73% of electricity, 80% of energy during peak electric grid use, and responsible for 39% of greenhouse gas emissions [14]. Urban-scale building energy modeling has grown significantly in the past decade, allowing individual campuses or communities of buildings to be modeled, simulated, and cost-effective solutions for intelligent management to be identified and implemented. While traditionally limited to individual counties and usually less than 2,000 buildings, the Automatic Building Energy Modeling (AutoBEM) soft-ware suite has been developed to process unconventional, nation-scale data sources to generate unique OpenStudio and EnergyPlus models of each building. Through the use of High Performance Computing (HPC) resources, every U.S. building has been simulated. This paper showcases the data layout, node partitioning, algorithmic approaches, and analytic results that were used to create, share, and analyze 124.4 million U.S. building models.

Berres, Andy↗

Leveraging Fine-Grained Occupancy Estimation Patterns for Effective HVAC Control

As occupancy sensing technologies become mature, various occupancy sensors are increasingly deployed in commercial buildings for pervasive occupancy monitoring. These sensors provide occupant-count data, which contains rich spatiotemporal information about occupancy patterns. With long-term occupant-count data collected from a commercial building, we design three different predictive models that capture the occupancy dynamics and examine how a model predictive control of the HVAC system benefits from actual occupancy count prediction. Our analysis reveals that mispredictions of occupancy states, especially false positives and false negatives, may introduce inefficient control that leads to energy waste or user discomfort. To address this issue, we take a step further to design an adaptive model predictive controller that minimizes inefficient control actions according to misprediction types and distributions. A comprehensive evaluation is performed in OpenBuild and EnergyPlus simulators to study the effectiveness of the proposed end-to-end control strategy. The evaluation shows that the proposed solution reduces energy consumption by 29.5% while improving the average weighted occupants comfort by 86.7% in Predicted Mean Vote (PMV) over the fixed schedule strategy.

97 MATHEMATICS AND COMPUTING↗