At least 217 records · Page 12

CT and Geophysical Data of Clinton Sandstone Cores from Ohio

Collection of computed tomography and multi-sensor core logger data of 12 wells in Ohio that intersect the Clinton Sandstone formation. This data is described along with well information in a technical report series document: Paronish, T.; Holleran, A.; Pohl, M.; Crandall, D.; Jarvis, K.; Workman, S.; Drosche, J.; McKisic, T.; Collins, C.; Thomas, M.; McDonald, J. Computed Tomography Scanning and Geophysical Measurements of the Clinton Sandstone in Ohio; DOE.NETL-2025.4949; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory, Morgantown, WV, 2025; p 68. https://doi.org/10.2172/2589262

AS↗

Impacts of irregularly-distributed acidified brine flow on geo-chemo-mechanical alteration in an artificial shale fracture under differential stress

The efficacy of geological carbon sequestration is reliant on the integrity of the caprock and its resistance to physical and chemical alteration. Caprocks with high abundance of reactive carbonates like calcite are susceptible to acid-promoted dissolution and can result in structural weakening. This work investigates the effect of acidified brine flow through an artificially fractured, high-carbonate (30 % by XRD) shale under differential compressive stress. Cylindrical samples were cut in half vertically and milled to create an artificial fracture with interlocking asperities and open channels. Samples were sheared with a single applied stress in a custom flow cell housed within an industrial CT scanner. Further, either acidic (pH 4) or reservoir-simulated (pH 9.5) brine was flowed through the artificial fracture for 7–8 days under reservoir pressure and room temperature. Model simulations indicate flow mainly occurred in open channels, with limited flow between overlapping asperities. Analysis of fracture surfaces by optical and scanning electron microscopy show increased surface alteration and roughness after exposure to pH 4 versus pH 9.5 brine indicating mineral dissolution/loss, and this effect is greater in areas that receive the highest brine flows. Similarly, surface analysis by scratch testing shows fracture toughness decreases more after exposure to acidic versus reservoir-simulated brine, with the greatest alteration in areas of highest acidic brine flows. Despite weakening, no shear slip occurred. Overall, the results indicate that acidified brine can result in significant physical and geomechanical alteration of irregular fracture surfaces in shale caprock, with greatest effects in preferential flow regions.

58 GEOSCIENCES↗

Automatic Detection of Defects in High-Reliability Components

Disastrous consequences can result from defects in manufactured parts—particularly the high consequence parts developed at Sandia. Identifying flaws in as-built parts can be done with nondestructive means, such as X-ray Computed Tomography (CT). However, due to artifacts and complex imagery, the task of analyzing the CT images falls to humans. Human analysis is inherently unreproducible, unscalable, and can easily miss subtle flaws. We hypothesized that deep learning methods could improve defect identification, increase the number of parts that can effectively be analyzed, and do it in a reproducible manner. We pursued two methods: 1) generating a defect-free version of a scan and looking for differences (PandaNet), and 2) using pre-trained models to develop a statistical model of normality (Feature-based Anomaly Detection System: FADS). Both PandaNet and FADS provide good results, are scalable, and can identify anomalies in imagery. In particular, FADS enables zero-shot (training-free) identification of defects for minimal computational cost and expert time. It significantly outperforms prior approaches in computational cost while achieving comparable results. FADS’ core concept has also shown utility beyond anomaly detection by providing feature extraction for downstream tasks.

47 OTHER INSTRUMENTATION↗

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗

CodEx: A Modular Framework for Joint Temporal De-Blurring and Tomographic Reconstruction

In many computed tomography (CT) imaging applications, it is important to rapidly collect data from an object that is moving or changing with time. Tomographic acquisition is generally assumed to be step-and-shoot, where the object is rotated to each desired angle, and a view is taken. However, step-and-shoot acquisition is slow and can waste photons, so in practice fly-scanning is done where the object is continuously rotated while collecting data. However, this can result in motion-blurred views and consequently reconstructions with severe motion artifacts. In this paper, we introduce CodEx, a modular framework for joint de-blurring and tomographic reconstruction that can effectively invert the motion blur introduced in sparse view fly-scanning. The method is a synergistic combination of a novel acquisition method with a novel non-convex Bayesian reconstruction algorithm. CodEx works by encoding the acquisition with a known binary code that the reconstruction algorithm then inverts. Using a well chosen binary code to encode the measurements can improve the accuracy of the inversion process. The CodEx reconstruction method uses the alternating direction method of multipliers (ADMM) to split the inverse problem into iterative deblurring and reconstruction sub-problems, making reconstruction practical to implement. Here we present reconstruction results on both simulated and binned experimental data to demonstrate the effectiveness of our method.

42 ENGINEERING↗

WARE 1-9 Well

Computed tomography and core logger data described in Technical Report "Computed Tomography Scanning and Geophysical Measurements of the J. F. WARE Gas Unit 1-9 Well in Smith County, Texas" by Brinza et al. , 2024.

CoreCM↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Computed Tomography Automation Architecture Developed from a Comprehensive Literature Review

This paper presents a literature review on techniques related to the computed tomography procedure that incorporate automation elements in their research investigations or industrial applications. Computed tomography (CT) is a non-destructive testing (NDT) technique in that the imaging and inspection are performed without damaging the sample, allowing for additional or repeated analysis if necessary. The reviewed literature is organized based on the steps associated with a general NDT task in order to define an end-to-end computed tomography automation architecture. The process steps include activities prior to image collection, during the scan, and after the data are collected. It further reviews efforts related to repeating this process based on a previous scan result. By analyzing the multiple existing but disparate efforts found in the literature, we present a framework for fully automating NDT procedures and discuss the remaining technical gaps in the developed framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Morphology and composition of Goldeye (Hiodontidae; Hiodon alosoides) otoliths

In this work, we provide up-todate morphological and compositional data on otoliths of the osteoglossomorph Goldeye (Hiodon alosoides). Using computed tomography (CT) X-ray, we documented the location of each of the three pairs of otoliths (lapilli, sagittae, and asterisci) in relation to the swim bladder, which extended forward in close proximity to the sagittae and asterisci. The lappili were the largest otoliths in terms of surface area and volume, but the sagittae were highly modified, appearing spiral in shape when viewed dorsally, with a surface area to volume ratio more than double that of the lapilli. Using scanning electron microscopy, the surface of each otolith was viewable in great detail, and small otoconia (~10.5 μm diameter) were observed on each, but were most numerous on the sagittae. Additionally, on scanning electron micrographs, the sagittae appeared to be bi-lobed, with asymmetrical lobes each oriented in the same general direction. Using neutron and X-ray diffraction methods, we found three polymorphs of calcium carbonate crystals (aragonite, vaterite, and calcite), sometimes all within the same otolith. However, in general, lapilli and sagittae were composed predominately of aragonite whereas asterisci were composed chiefly of vaterite. With these results, we provide information on a unique species, whose inclusion in future studies would benefit our understanding of fish hearing, fish evolution, and fisheries ecology.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of gradation on failure mode of saturated sand at particle scale

Extensive research has been reported in the literature to characterize the failure mode of dry sand using various experimental techniques such as surface optical imaging, photo-elastic materials, three-dimensional (3D) computed tomography (CT), and 3D synchrotron micro-computed tomography (SMT). However, there is a limited literature about the behavior of saturated sand. This paper presents the results of axisymmetric triaxial compression (ATC) experiments that were conducted on saturated sand specimens. The behavior of specimens composed of a uniform sand with grain size between US sieves #40 and #50 is compared to specimens conducted on the same sand that has a wider gradation. 3D SMT technique was used to acquire 3D scans while shearing the specimens to probe localized events that are completely missed or misinterpreted when analyzing ATC measurements based on global standard measurements. The results show a higher effective principal stress ratio (EPSR) for the non-uniform specimen and a thicker shear band when compared to uniform specimen.

Elnur, Mohammed [University of Tennessee]↗

Surface Local Impurity Scattering as a Probe for Topological Kondo Insulators

Shortly after the discovery of topological band insulators, topological Kondo insulators (TKIs) is also theoretically predicted. The latter has ignited revival interest in the properties of Kondo insulators. Currently, the feasibility of topological nature in SmB 6 is intensively analyzed by several complementary probes. Here by starting with a minimal-orbital Anderson lattice model, the local electronic structure is explored in a Kondo insulator. It is showed that the two strong topological regimes sandwiching the weak topological regime give rise to a single Dirac cone, which is located near the center or corner of the surface Brillouin zone. It is further found that, when a single impurity is placed on the surface, low-energy resonance states are induced in the weak scattering limit for the strong TKI regimes and the resonance level moves monotonically across the hybridization gap with the strength of impurity scattering potential; while low energy states can only be induced in the unitary scattering limit for the weak TKI regime, where the resonance level moves universally toward the center of the hybridization gap. These impurity-induced low-energy quasiparticles will lead to characteristic signatures in scanning tunneling microscopy/spectroscopy, which has recently found success in probing into exotic properties in heavy fermion systems.

36 MATERIALS SCIENCE↗

Citizen Green #1 Well: Drilling, Deviation, Mud, Whole Core, and Observation Logs

This submission includes drilling logs, mud log, deviation survey, site observation notes, and whole core scans from the Citizen Green #1 well drilled on King Island, CA (API 07720688) as part of the WESTCARB partnership basin characterization effort. These datasets were gathered by JAF but created and compiled by a variety of WESTCARB operations team members and contractors including Sandia Resources, Stratagraphic Corp, John Henry Beyer, Paul Graham Drilling, and Core Labs.

Core CT↗

Gas pore correlations in laser powder bed fusion of Al6061

Additive manufacturing (AM) of metal materials based on powder bed fusion technology is widely used now in many industries. A known limitation of this type of manufacturing is the formation of gas pores in the bulk material. Here we present a combined X-ray imaging and mid-infrared pyrometry study of pore formation in side-by-side tracks of Al6061 for different processing conditions using both in-situ and post-processing analysis. By carefully quantifying the distributions and correlations of pore positions, we show that an existing pore in one track often catalyzes the formation of another pore in an adjacent track. In a raster scan strategy commonly used to construct bulk material, this phenomenon has the result of forming subsurface perforations, or lines of pores transverse to the scanning direction in a rastered patch. If controlled, this effect can be eliminated to improve the yield strength of the build, or exploited to create programmable failures for specific purposes.

36 MATERIALS SCIENCE↗

Sleepy Hollow Reagan Unit 86A Well Data

Computed tomography data described in the technical report series "Computed Tomography Scanning and Geophysical Measurements of the Integrated Mid-Continent Stacked Carbon Storage Hub Sleepy Hollow Reagan Unit 86A Well" by Thomas Paronish; Mathias Pohl; Alexis Parker; Rhiannon Schmitt; Johnathan Moore; Richard Spaulding; Igor Haljasmaa; Dustin Crandall; Valarie Smith; Andrew Duguid; and R. M. Joeckel

AS↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

Simurgh: A Framework for Cad-Driven Deep Learning Based X-Ray CT Reconstruction

High-resolution X-ray computed tomography (XCT) is an important technique for the inspection of additively manufactured (AM) parts. While XCT is typically used off-line to inspect a subset of manufactured parts, significantly accelerating measurement speed while retaining accuracy would enable use of XCT for in-line inspection to rapidly identify defects in each part as it is manufactured. Here, we propose a deep learning (DL) based approach that uses computer aided design (CAD) models of the AM parts and physics-based information to rapidly produce high-quality reconstructions from sparse XCT measurements without high quality ground truth data. Our approach uses a generative adversarial neural network (GAN) to produced realistic training data from the CAD-based simulations and a deep neural network that is trained using data from the first stage to produce accurate 3D reconstructions. Using experimental XCT data of metal parts, we demonstrate enhanced defect detection capabilities while dramatically reducing the scan time.

Ziabari, Amir↗

The use of subchondral bone topography to approximate the center of rotation of the elbow joint in dogs

Abstract Objectives The aim of this study was to compare the approximate center of rotation in normal and diseased elbows in dogs. Study design Cross‐sectional study Sample population Computer tomography scans of nine dogs with unilateral fragmented medial coronoid process (FMCP). Methods A board certified radiologist confirmed that each dog had unilateral FMCP, and a normal contralateral elbow. Digital 3D models of all elbow joints were uploaded into a surgical planning software package. Four axes approximating the center of rotation (COR) of elbow joints were generated using five geometric shapes based on subchondral topography of the humeral condyle radius and ulna. Images showing the locations where axes exited the medial and lateral cortex of the humeral condyle were captured and imported into a second software package, for measurement of distances between exit points and the origin of a system of axes. Results In normal joints 20/27 (74%) axes exited the medial cortex, and 25/27 (93%) axes exited the lateral cortex cranial and distal to the medial and lateral epicondyles, respectively. In diseased joints 22/27 (81%) axes exited medial cortex and 19/27 (70%) axes exited the lateral cortex, caudal and distal to the medial and lateral epicondyles, respectively. Conclusion Based on CT‐ derived geometry, the COR of elbow affected with FMCP was generally more caudal than normal. Clinical significance External landmarks approximating the location of the elbow COR are provided, and while not validated, may assist in planning, creation, and assessment of procedures for FMCP.

Berger, Chen↗