Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump

Residential heat pumps have advanced over the past decade to allow for operation at colder temperatures. However, the challenges of frost accumulation and defrosting the outdoor coil remain. The goal of this study was to evaluate the impact of the control algorithms that determine when a heat pump needs to defrost and when the base pan heater runs on the overall heating efficiency of the heat pump. In this study, which occurred during the 2023–2024 heating season, we measured the performance of a ductless air-source heat pump installed in Fairbanks, Alaska, USA. The heat pump was instrumented to measure the electrical input and the thermal output, as well as selected internal variables and indoor and outdoor environmental conditions. The heat pump was first operated with factory default control algorithms associated with the initiation of defrost and control of the base pan heater. These factory default algorithms focused on aggressively defrosting the outdoor coil and keeping the base pan ice-free. In the middle of the winter, these algorithms were changed to focus on reducing defrost cycles and increasing efficiency, while the heat pump continued to be operated and monitored. The results showed that significant increases in efficiency are possible by improving the defrost and base pan heater control algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization Considerations for Annular Linear Electromagnetic Pumps for Space Nuclear Power and Propulsion

The Need for High Performance Liquid Metal Pumps Testing Power and Efficiency Considerations Liquid metal cooled reactors is one option for space nuclear power for settlements and electric propulsion vehicles (Snap 10 A, SP100, Soviet Topaz reactors) • High heat capacity • High boiling point (NaK~1200K) • Simplified heat transfer loop • Good neutronics Liquid metal EM pumps are desired over conventional pumps owing to lack of seals, bearings elimination of cavitation issues, lower mass and eliminates mechanical impeller • Conduction pumps (typically DC-high current, low voltage; ~5% efficiency) • Induction pumps (typically AC, high efficiency ~40%) Annular linear induction pump is an EM pump with no moving parts and of cylindrical/tubular geometry which makes it straightforward to integrate in conventional piping architectures • Higher inherent reliability • Invented by Einstein and Szilard

ALIP↗

Virtual refrigerant charge sensing algorithm for residential CO₂ heat pumps

Natural refrigerants are increasingly adopted in next-generation heat pump systems, among which CO₂ heat pumps have attracted significant attention. However, due to their high operating pressures, the leakage risk is higher, resulting in undercharge conditions and degraded heat pump performance. Thus, developing an accurate refrigerant charge level detection technique is necessary to guarantee safe and efficient operation. Although virtual refrigerant charge (VRC) level calculation algorithms for CO₂ heat pumps exist, they typically rely on empirically selected features without a systematic selection framework, leading to multicollinearity and potential overfitting, which limit their prediction accuracy and generalizability. To address these issues, this study proposes a VRC algorithm framework with a systematic feature selection method that identifies physically meaningful and statistically significant features, and is applied using a residential CO₂ heat pump as a case study. The method is extended from previous work on conventional refrigerants to account for charge behavior in CO₂ gas coolers. The selected features include gas cooler outlet density, evaporator pressure, and superheat temperature. The results demonstrate that the proposed feature selection method significantly improves prediction accuracy compared to existing VRC approaches. A relatively small training dataset (∼30 samples) is sufficient for feature identification and model development. The developed algorithm achieves less than 3% prediction error under both undercharge and overcharge conditions, representing reductions of 46.7% and 35.3% compared to two recent reference VRC algorithms for transcritical CO₂ heat pumps reported in the literature. The proposed algorithm and feature selection method enhance leakage detection capability, facilitate the deployment of CO₂ heat pump systems, and contribute to reduced energy waste and maintenance costs.

Guo, Fangzhou [Lawrence Berkeley National Laborato↗

Stirring and peristaltic pumping alter flow electrode particle size and morphology

Flowable carbon-based electrodes are widely studied in electrochemical systems for energy storage and water treatment. Most laboratory- and pilot-scale studies employ active mixing for slurry preparation and handling and use peristaltic pumps for slurry circulation. Magnetic stirring is the most prevalent mixing method at the laboratory scale, and the combination of magnetic mixing and peristaltic pumping is favored for convenience and compatibility with particulate suspensions. However, these methods can strongly affect particle size and morphology (and therefore cell performance). In this study, we evaluate how mixing and pumping influence particle degradation in two commonly used carbon materials: spherical carbon black (CB) beads and powdered activated carbon (AC). We performed 24 h stirring-only experiments using magnetic, orbital, and overhead stirring. Separately, we conducted 32 h circulation experiments using a commercial peristaltic pump. Particle morphology and size were analyzed using optical microscopy and laser diffraction. The initially spherical CB beads (~580 μm, 1.5 wt%) exhibit rapid and extensive breakdown under both peristaltic pumping and magnetic stirring. By comparison, AC particles (initially ~31 μm) tested at 1.5 and 15 wt% showed measurable size reductions of up to ~25 % under either stirring or pumping. In conclusion, these findings highlight the need to account for and quantify morphological changes caused by both stirring and pumping in the design and associated evaluation of flowable electrode systems.

Chemistry↗

Influence of pump laser fluence on ultrafast myoglobin structural dynamics

High-intensity femtosecond pulses from an X-ray free-electron laser enable pump–probe experiments for the investigation of electronic and nuclear changes during light-induced reactions. On timescales ranging from femtoseconds to milliseconds and for a variety of biological systems, time-resolved serial femtosecond crystallography (TR-SFX) has provided detailed structural data for light-induced isomerization, breakage or formation of chemical bonds and electron transfer. However, all ultrafast TR-SFX studies to date have employed such high pump laser energies that nominally several photons were absorbed per chromophore. As multiphoton absorption may force the protein response into non-physiological pathways, it is of great concern whether this experimental approach allows valid conclusions to be drawn vis-à-vis biologically relevant single-photon-induced reactions. Here we describe ultrafast pump–probe SFX experiments on the photodissociation of carboxymyoglobin, showing that different pump laser fluences yield markedly different results. In particular, the dynamics of structural changes and observed indicators of the mechanistically important coherent oscillations of the Fe–CO bond distance (predicted by recent quantum wavepacket dynamics) are seen to depend strongly on pump laser energy, in line with quantum chemical analysis. Our results confirm both the feasibility and necessity of performing ultrafast TR-SFX pump–probe experiments in the linear photoexcitation regime. We consider this to be a starting point for reassessing both the design and the interpretation of ultrafast TR-SFX pump–probe experiments such that mechanistically relevant insight emerges.

59 BASIC BIOLOGICAL SCIENCES↗

SR19039 - All Metal Vacuum Scroll Pump Development for Tritium

Currently the Savannah River Site tritium gas processing mission relies on a pumping train combination of a Normetex scroll pump backed by a Metal Bellows MB-601 diaphragm pump. Both of these pumps have wetted components that are "all-metal" so that no polymers or elastomers that can degrade due to tritium gas exposure are exposed to the process fluid. Normetex, the original all-metal vacuum scroll pump manufacturer, has gone out of business. Another French based company, Eumeca, has "spun off" from the Normetex company and is now producing the original, 9 cfm all metal Normetex vacuum scroll pump. It should be noted that Normetex, now Eumeca, is currently the only supplier of a functional all metal vacuum scroll pump to meet the SRS tritium gas processing requirement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Model-based Design Optimization to Achieve the Performance Goals (16.0 SEER/9.5 HSPF), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Usage of low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Our research in previous milestone report has shown that using heat exchangers with 5 mm diameter tubes instead of 9 mm diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants. In addition, the 5mm tube heat exchangers can lead to lower system refrigerant charge and as a result, reduce environmental impact further. However, shifting to small tube diameters requires in-depth heat exchanger design optimization to adapt to the transition to low-GWP refrigerants. In the 2nd quarter of FY21, we conducted multi-objective optimizations using Particle Swarm Optimization algorithm on a residential 5-ton air source heat pump to investigate the potential system performance improvements and material savings. 4 low-GWP refrigerants, ARM20A, ARM20B, R454A and R454C are investigated in this study. The objectives of the optimization are to minimize the heat pump material cost and to maximize the system performance simultaneously. As a result, the HXs material cost is reduced by up to 77% according to the copper and aluminum material price in current market. Under heating mode operation, the smart 4-way valve guarantees that the optimal low-GWP systems maintain or outperform the heating performance of the R410A baseline system. The model-based design optimization yields 18.3-18.9 SEER and 10.6-11.9 HSPF for optimal systems using different low-GWP refrigerants. The initial performance goals (16.0 SEER/9.5 HSPF) are achieved. Furthermore, up to 50% system refrigerant charge reduction is possible in the optimized low-GWP heat pump system using ARM20B. And 91%-95% predicted life-time direct CO 2 emission reduction is achieved by using the optimal 5mm tube low-GWP heat pumps. The significant material saving, charge reduction and direct CO 2 emission reduction help in reducing the environmental impacts of heat pump systems. The optimal heat exchangers resulting from this research can fit into the original baseline indoor and outdoor fan-coil unit. This can reduce the retrofitting effort by minimizing the change in manufacturing and installation of the heat pumps and guarantee the compatibility with end-users’ house structure. Finally, the new products can be easily accepted by manufacturers and end-users.

42 ENGINEERING↗

Investigating Cryogenic Pump Lifetime and Exploring Alternative Designs

Cryogenic pumps are necessary for the operation of several neutrino experiments at Fermilab where some of the primary components of the detectors are liquid argon and liquid nitrogen. The pumps currently in use are centrifugal pumps with a small vortex impeller, manufactured by Barber Nichols. This pump has an average lifetime of 8000 hours. Such a short lifetime means that each pump requires maintenance multiple times a year, which is not optimal. The goal of this project was to determine what aspects of the current pump design could be modified to improve the lifetime of the pump such that it would only require maintenance once a year. In this poster I present on the different areas of design improvement that were identified.

Baakkonen, Katie↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗

An evaluation of a hubless inducer and a full flow hydraulic turbine driven inducer boost pump

The purpose of the study was to compare the performance of several configurations of hubless inducers with a hydrodynamically similar conventional inducer and to demonstrate the performance of a full flow hydraulic turbine driven inducer boost pump using these inducers. A boost pump of this type consists of an inducer connected to a hydraulic turbine with a high speed rotor located in between. All the flow passes through the inducer, rotor, and hydraulic turbine, then into the main pump. The rotor, which is attached to the main pump shaft, provides the input power to drive the hydraulic turbine which, in turn, drives the inducer. The inducer, rotating at a lower speed, develops the necessary head to prevent rotor cavitation. The rotor speed is consistent with present main engine liquid hydrogen pump designs and the overall boost pump head rise is sufficient to provide adequate main pump suction head. This system would have the potential for operating at lower liquid hydrogen tank pressures.

Lindley, B. K.↗

Chemical pump study for Pioneer Venus program

Two chemical pumps were designed for the Pioneer Venus large probe mass spectrometer. Factors involved in the design selection are reviewed. One pump is designed to process a sample of the Venus atmosphere to remove the major component, carbon dioxide, so that the minor, inert components may be measured with greater sensitivity. The other pump is designed to promote flow of atmospheric gas through a pressure reduction inlet system. This pump, located downstream from the mass spectrometer sampling point, provides the pressure differential required for flow through the inlet system. Both pumps utilize the reaction of carbon dioxide with lithium hydroxide. The available data for this reaction was reviewed with respect to the proposed applications, and certain deficiencies in reaction rate data at higher carbon dioxide pressures noted. The chemical pump designed for the inert gas experiment has an estimated volume of 30 cu cm and weight of 80 grams, exclusive of the four valves required for the operation. The chemical pump for the pressure reduction inlet system is designed for a total sample of 0.3 bar liter during the Venus descent.

Rotheram, M.↗

ECC ozonesonde performance at high altitudes: Pump efficiency

The ECC ozonesonde sampling behavior was examined at pressures ranging from 60 to 6 hPa with the objective of evaluating uncertainties in high altitude ozone data caused by variations in pumping efficiency. The averaged pump efficiency correction curve for a 43 sample set of 3A type ECC pumps showed a 2-3% bias from the curve provided by the manufacturer. In addition, random pump to pump variations (2 sigma) + or - were 5% at 6 hPa. These values probably represent minimum errors since the pumps were from the same production batch. A seven sample set of the newer 4A type ECC pumps was examined, with similar findings as for the 3A types.

Torres, A. L.↗

Small centrifugal pumps for low thrust rockets

This paper presents the results of a combined analytical and experimental investigation of low specific speed pumps for potential use as components of propellant feed systems for low thrust rocket engines. Shrouded impellers and open face impellers were tested in volute type and vaned diffuser type pumps. Full- and partial-emission diffusers and full- and partial-admission impellers were tested. Axial and radial loads, head and efficiency versus flow, and cavitation tests were conducted. Predicted performance of two pumps are compared when pumping water and liquid hydrogen. Detailed pressure loss and parasitic power values are presented for two pump configurations. Partial-emission diffusers were found to permit use of larger impeller and diffuser passages with a minimal performance penalty. Normal manufacturing tolerances were found to result in substantial power requirement variation with only a small pressure rise change. Impeller wear ring leakage was found to reduce pump pressure rise to an increasing degree as the pump flowrate was decreased.

Gulbrandsen, N. C.↗

Direct solar-pumped iodine laser amplifier

This semiannual progress report covers the period from April 1, 1985 to Sept. 30, 1985 under NASA grant NAS1-441 entitled direct solar pumped iodine laser amplifier. During this period the parametric studies of the iodine laser oscillator pumped by a Vortek simulator was carried out before the amplifier studies. The amplifier studies are postponed to the extended period following completion of the parametric studies. In addition, the kinetic modeling of a solar pumped iodine laser amplifier, and the experimental work for a solar pumped dye laser amplifier are in progress. This report contains three parts: (1) the radiation characteristics of solar simulator and the parametric characteristics of photodissociation iodine laser continuously pumped by a Vortek solar simulator; (2) kinetic modeling of a solar pumped iodine laser amplifier; and (3) the study of the dye laser amplifier pumped by a Tamarack solar simulator.

Han, K. S.↗

A review of laser-pumped infrared lasers

The lasing mechanisms are reviewed of molecules that have demonstrated laser action in the laboratories with laser emissions in the spectral range from 3 to 35 microns. A list of lasants and laser mechanisms are defined. The pumping sources for these lasers are mainly infrared lasers; however, the case in which excitation of bromine atoms at 2.71 microns by a flashlamp as energy input is also included in the review. A conceptual drawing of lasing mechanisms is shown. Three pumping mechanisms are shown, the first being the direct-pumped system in which the lasant molecule absorbs the infrared radiation from pump laser directly, and it is excited into the upper laser level from the ground state. The second system is the indirect-pumped system where the infrared-pump laser first excites an absorbing molecule which stores its vibrational energy. Through collision this energy is transferred to the lasant molecule, populating the upper laser level. In the third system, i.e., in a Br2-CO2 mixture, a flashlamp replaces the infrared laser as the pump source for the absorbing molecule.

Chen, K. Y.↗

The Capillary Pumped Loop (CPL) GAS experiment G-471

The Capillary Pumped Loop (CPL) experiment, 6-471 is a thermal control system with high density heat acquisition and transport capability. The CPL consists of two capillary pumped evaporators with integral heaters, a fluid loop charged with ammonia (NH3), a condenser plate (heat sink), and various control electronics. The purpose of the experiment is to demonstrate the capability of a capillary pumped system under zero gravity conditions for use in the thermal control of large scientific instruments, advanced orbiting spacecraft, and space station components. A unique feature of the CPL is the capillary pumps, which contain no moving parts. Each pump contains a wick of porous material which is saturated with the working fluid (anhydrous ammonia). As heat is added to the fluid, it evaporates and travels to the condenser, thus transporting the heat (via the latent heat of vaporization) from the heat source to its sink at nearly a constant temperature. The evaporation process produces the pressure gradient or pumping action that circulates the fluid. This is the same principal that plants and trees use to transport water and nutrients from their roots to their leaves against gravity. The difference is that the CPL employs a closed system to return the fluid directly to the pumps, whereas "Mother Nature'' has an open system where the fluid is indirectly returned to the roots by condensation of water from the clouds in the form of rain. It should be noted that the CPL experiment was the first flight of a thermal control system of this type. It was also the first shuttle experiment from the Space Station Advanced Development Program.

Dan Butler↗