Abstract

Cryogenic pumps are necessary for the operation of several neutrino experiments at Fermilab where some of the primary components of the detectors are liquid argon and liquid nitrogen. The pumps currently in use are centrifugal pumps with a small vortex impeller, manufactured by Barber Nichols. This pump has an average lifetime of 8000 hours. Such a short lifetime means that each pump requires maintenance multiple times a year, which is not optimal. The goal of this project was to determine what aspects of the current pump design could be modified to improve the lifetime of the pump such that it would only require maintenance once a year. In this poster I present on the different areas of design improvement that were identified.