Integrated Optic Frequency Shifters for Space Heterodyne Interferometry
Heterodyne interferometer laser gauges are used in space-based astronomical interferometers to very accurately measure and compensate for variations in starlight pathlength.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Heterodyne interferometer laser gauges are used in space-based astronomical interferometers to very accurately measure and compensate for variations in starlight pathlength.
Floquet engineering offers a compelling approach for designing the time evolution of periodically driven systems. We implement a periodic atom-light coupling to realize Floquet atom optics on the strontium 1 S 0 - 3 P 1 transition. These atom optics reach pulse efficiencies above 99.4% over a wide range of frequency offsets between light and atomic resonance, even under strong driving where this detuning is on the order of the Rabi frequency. Moreover, we use Floquet atom optics to compensate for differential Doppler shifts in large momentum transfer atom interferometers and achieve state-of-the-art momentum separation in excess of 400 ℏk. In conclusion, this technique can be applied to any two-level system at arbitrary coupling strength, with broad application in coherent quantum control.
SIM Planetquest (SIM) is a large optical interferometer for making microarcsecond measurements of the positions of stars, and to detect Earth-sized planets around nearby stars. To achieve this precision, SIM requires stability of optical components to tens of picometers per hour. The combination of SIM s large size (9 meter baseline) and the high stability requirement makes it difficult and costly to measure all aspects of system performance on the ground. To reduce risks, costs and to allow for a design with fewer intermediate testing stages, the SIM project is developing an integrated thermal, mechanical and optical modeling process that will allow predictions of the system performance to be made at the required high precision. This modeling process uses commercial, off-the-shelf tools and has been validated against experimental results at the precision of the SIM performance requirements. This paper presents the description of the model development, some of the models, and their validation in the Thermo-Opto-Mechanical (TOM3) testbed which includes full scale brassboard optical components and the metrology to test them at the SIM performance requirement levels.
Picometer scale optical metrology specifications for the Space Interferometry Mission require precision calibration functions involving the optical and orientation characteristics of corner cube.
A closed loop phase control system using an all-fiber optical configuration has been developed for use in phase-stepping interferometry. This system drives the relative phase of two interfering beams through a sequence of pi/2 rad increments so that the initial relative phase of these beams can be determined. This phase-stepping system uses optical fibers to provide spatially uniform phase steps from a flexible, easily aligned optical configuration. In addition, this system uses phase feedback to eliminate phase modulator errors and to compensate for phase drifts caused by environmental disturbances.
The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.
Optical and infrared interferometry will open new vistas for astronomy over the next decade.
At micro- and nanoscales, momentum transfer between surfaces is influenced by various physical mechanisms, including quantum fluctuations, electromagnetic interactions, electric charges, and the dynamics of (rarefied) gases. Under non-isothermal conditions, rarefied gases give rise to thermal Knudsen forces whose magnitudes strongly depend on the gas species and surface characteristics. Knudsen forces are particularly relevant in nanotechnology, optical manipulation, and aerospace systems, where gas rarefaction occurs due to highly confined geometries, sub-micrometer length scales, and reduced particle densities. Despite their significance, predictive modeling of Knudsen forces is limited by a lack of comprehensive experimental data across diverse materials and surface morphologies. Here, in this work, we present a highly sensitive and adaptable measurement platform capable of directly quantifying Knudsen forces using a suspended, interchangeable micro-cantilever within controlled rarefied helium and nitrogen environments. The system integrates optical fiber interferometry to precisely capture out-of-plane displacements at sub-micrometer resolution, driven by Knudsen forces. From the empirical data, we derive a robust correlation linking the magnitudes of Knudsen forces to energy accommodation coefficients, offering deeper insights into the underlying gas–surface interaction mechanisms.
Multi-photon Bragg diffraction is a powerful method for fast, coherent momentum transfer of atom waves. However, laser noise, Doppler detunings, and cloud expansion limit its efficiency in large momentum transfer (LMT) pulse sequences. We present simulation studies of robust Bragg pulses developed through numerical quantum optimal control. Optimized pulse performance under noise and cloud inhomogeneities is analyzed and compared to analogous Gaussian and adiabatic rapid passage pulses in simulated LMT Mach–Zehnder interferometry sequences. The optimized pulses maintain robust population transfer and phase response over a broader range of noise, resulting in superior contrast in LMT sequences with thermal atom clouds and intensity inhomogeneities. Large optimized LMT sequences use lower pulse area than Gaussian pulses, making them less susceptible to spontaneous emission loss. The optimized sequences maintain over five times better contrast with tens of momentum separation and offer more improvement with greater LMT. Such pulses could allow operation of Bragg atom interferometers with unprecedented sensitivity, improved contrast, and hotter atom sources.
Explore the source record for details and available documents.
An exemplary apparatus can provide radiation to a sample(s), which can include, for example, a radiation source arrangement configured to provide radiation, a beam splitter configured to split the radiation into (i) a first radiation, and (ii) a second radiation. An optical element can also be provided which, in operation, can, e.g., (a) receive the first radiation and the second radiation, (b) reflect the first radiation as a reference radiation, (c) provide the second radiation as illumination for the sample(s), (d) receive a resultant radiation from the sample(s) that can be based on the illumination from the second radiation, and (e) provide the reference radiation and the resultant radiation to be detected and used for interferometric imaging or spectroscopy.
Improvements in the quality of synchrotron beamline x-ray optics required for next-generation light sources (e.g. the ALS Upgrade project) drive the need to improve the performance of the metrology instrumentation used to measure these components. The Long Trace Profiler (LTP) that is in use at many synchrotron metrology laboratories around the world has some known issues that affect the accuracy of its measurements. The main error source is optical path difference (OPD) phase error introduced into the probe beam by inhomogeneities in the glass components used in the optical head. We have developed a new optical head design, LTP-2020, that replaces the cube polarizing beamsplitter (PBS) with a thin wedge plate polarizing beamsplitter (WPBS) and replaces the cemented doublet lens with an aspheric singlet. Both of these components significantly reduce the glass volume traversed by the laser probe beam. Careful attention to ghost ray interference produced by back reflection from optical surfaces is necessary to minimize distortion in the primary image that translates into systematic error in the slope angle measurement. We make extensive use of a commercial raytracing program to model the back reflections and adjust component parameters as necessary to minimize distortion. Deliberate misalignment of components is necessary to make the system perform correctly. Stringent requirements are placed on the 45◦ incidence coatings on the WPBS and on the normal incidence coatings on the lens and camera window elements. We encourage our colleagues who wish to upgrade their current LTP systems to join us in the procurement of these custom optical components.
The long baselines of the next-generation ground-based optical stellar interferometers require optical delay lines which can maintain nm-level path-length accuracy while moving at high speeds. NASA-JPL is currently designing delay lines to meet these requirements. The design is an enhanced version of the Mark III delay line, with the following key features: hardened, large diameter wheels, rather than recirculating ball bearings, to reduce mechanical noise; a friction-drive cart which bears the cable-dragging forces, and drives the optics cart through a force connection only; a balanced PZT assembly to enable high-bandwidth path-length control; and a precision aligned flexural suspension for the optics assembly to minimize bearing noise feedthrough. The delay line is fully programmable in position and velocity, and the system is controlled with four cascaded software feedback loops. Preliminary performance is a jitter in any 5 ms window of less than 10 nm rms for delay rates of up to 28 mm/s; total jitter is less than 10 nm rms for delay rates up to 20 mm/s.
Recent advances in cold atom interferometry with optical and magnetic atom guides have set the stage for quantum inertial sensors capable of operating in dynamic environments. In this work, we present three key innovations—evanescent-field (EF) atom guides, optical nanofiber testbeds, and membrane-waveguide photonic integrated circuit (PIC) platforms—to advance EF-guided atom interferometry. First, we demonstrate EF atom guides on optical nanofiber testbeds, which serve as performance benchmarks for our membrane-waveguide PIC platforms. Second, we achieve low-power ( ~ 5 mW) guiding of freely moving, laser-cooled 133 Cs atoms in two-color, traveling-wave EF optical dipole traps at the novel, heat-efficient magic wavelengths of 793 and 937 nm (i.e., “793/937-nm EF atom guides”). Concurrently, we design and fabricate membrane-waveguide PIC platforms for these EF atom guides; in our prior work, we showed that these structures safely accommodate 4–6 times the required optical trap power under vacuum and enable dense cold atom generation via magneto-optical trapping in the vicinity of the optical wavguide for efficient loading. Third, we verify preserved atomic coherence via microwave fields and EF-coupled Doppler-free Raman beams; to our knowledge, this is the first report of coherence fringes driven by co-propagating EF-coupled Raman beams with only 150 nW of total optical power. By providing a direct comparison between optical nanofiber testbeds and membrane-waveguide PIC platforms, our results lay critical groundwork for the on-chip realization of EF-guided atom interferometry and the development of fully integrated, compact, lightweight, and low-power quantum accelerometers and gyroscopes.
A microwave–photonic low-coherence interferometry (MPLCI) system is proposed for fully distributed optical fiber sensing. Assisted by an unbalanced Michelson interferometer, a low-coherence laser source is used to interrogate cascaded Fabry–Perot interferometers along with an optical fiber for a dark zone free (or spatially continuous) distributed measurement. Here, by combining the advantages of microwaves and photonics, the MPLCI system can synergistically achieve high sensitivity and high spatial resolution. Our tests have confirmed a strain resolution of 95 nε at the spatial resolution of 10 cm.
The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.
Deep Space 3 will fly a stellar optical interferometer on three separate spacecraft in heliocentric orbit: one spacecraft for the Michelson beam combining optics, and two spacecraft for each of the starlight apertures.
A high-precision optical method is presented for aligning diffraction grating molds with the edges of specimens in moire interferometry. The alignment fixture is simple and convenient to operate. The conventional method of grating-mold alignment has a wide band of uncertainty in the range of error which is not compatible with the required precision of high-sensitivity moire interferometry. Following a description of the alignment technique, both the single-edge and parallel-edge guide bar optical alignment methods are introduced and compared.