At least 199 records · Page 11

Grazing incidence reflection coefficients of rhodium, osmium, platinum, and gold from 50 to 300 A

Reflectance measurements were made of several metals illuminated from various angles with light at 14 wavelengths in the interval 46.5-283 A. The metals, Rh, Os, Pt and Au were deposited as 125 A films on a binding substrate through electron beam epitaxy. Measurements were made with a grazing incidence monochromator and a reflectometer. The data generally showed lowered reflectance with increasing angles of illumination and shorter wavelengths. The reflectance peak, however, was located at wavelengths of 100-160 A, particularly at large grazing incidences. The wavelengths correspond with the 5p to epsilon-d transition in all of the elements. Rh displayed the highest overall reflectance, and both Rh and Os were more efficient than Au or Pt.

Hettrick, M. C.↗

OH radical measurements by optical absorption spectroscopy

The long path absorption spectroscopy (LPA) measurement of OH utilizes the strong UV absorption spectrum of the molecule with well resolved rotational lines around 308 nm. The light source consists of an Ar ion laser pumped CW dye laser, the output of which is frequency doubled to emit a spectrally smooth light profile of 0.1 nm FWHM at 308 nm. This is considerably broader than the sharp (0.0018 nm wide) absorption features of OH and also wider than the total spectral region (0.06 nm) scanned around the OH lines. For field measurements a Cassegrain-type telescope expands the small diameter of the original laser beam by a factor of 50 to about a 0.25-m diameter in order to reduce the divergence of the beam as well as its mean photon flux density, thus reducing the maximum self-generated OH concentration to 40,000 cu. cm. The light is passed into the open atmosphere and reflected at about 5 km distance resulting in a 10-km light path length. A telescope focuses the returning light onto the entrance slit of a monochromator the single exit slit of which is replaced by a mechanical scanning device operating at a scan repetition rate of 6.6 KHz. For a typical measurement (1h duration) some 20,000,000 scans are averaged, rendering the contribution of atmospheric turbulence to the spectral noise negligible.

Platt, U.↗

Holographic gratings for spectrographic applications: Study of abberations

A computer program was developed that determines the optimum holographic grating recording parameters as a function of optical instrumental parameters and desired wavelength range for Seya-Namioka monochromator mountings. The theory and basic equations for designing holographic concave gratings such that minimization of aberrations of astigmatism or coma over a desired wavelength range may be achieved are presented. The computer program is described, including all of the subroutines. The input data, definitions of terms, and data card description are presented. An example is summarized for using the program and the output data is described in detail.

Bhatia, Manjit S.↗

TAE Plus: A conceptual view of TAE in the space station era

The use of the Transportable Applications Executive (TAE) for prototyping user interfaces has been the prime force behind the new TAE research and development work. The Data Systems Technology Division at GSFC is developing prototypes of user interfaces for different functions involved in the operation, analysis and data communication of space station payloads. TAE is a valuable prototyping tool because it enables a developer to build an entire application user interface model and run it without writing a single line of application code. One force driving new development is the need to update TAE's user interface to support the latest interactive graphic device technology. The current TAE, TAE Classic, uses interface techniques designed for an 80x24 character monochrome alphanumeric terminal, but does not effectively utilize features such as windowing, graphics, color, and selection devices available on newer workstations. To meet our needs, development of a TAE Plus began in FY-86 and involves augmenting TAE with three different sets of tools: a user interface toolkit; an application toolkit; and run-time service subroutines. A phased approach is being used to develop TAE Plus. In the first phase, we have met the needs of the user community and provided some support for rapid prototyping by developing a TAE Facelift, which adds an enhanced TAE interface (with windowing, mouse interaction, pull-down menus, etc.) to a select set of graphic workstations. The TAE Facelift allows many new concepts to be tested quickly for feedback and performance. In the second phase, a fully-integrated user interface management system, TAE Plus, will be built that supports the separation of interface from application, with the concomitant ability to prototype and rapidly change interfaces. This robust functionality will support, in an integrated manner, an application's development cycle from the prototype step through to the fully operational system.

Szczur, Martha↗

Soft X-ray photoemission with the SSX-100 spectrometer

Photoemission and SEXAFS experiments were conducted using a double crystal monochromator at the Stanford Synchrotron Radiation Laboratory. Photoelectrons were detected using a Surface Science Laboratories SSX-100 electron analyzer, which employs a magnetic/electrostatic lens, hemispherical geometry, and a two-dimensional position-sensitive detector. In the kinetic energy range of interest (1000-2000 eV), a significant improvement in count rate was observed over a single channel cylindrical mirror analyzer system. Ten second scans of the KLL silicon Auger peak manifold were recorded at a large number of photon energies for subsequent determination of SEXAFS spectra.

Hecht, M. H.↗

Subroutines For Image Processing

Image Processing Library computer program, IPLIB, is collection of subroutines facilitating use of COMTAL image-processing system driven by HP 1000 computer. Functions include addition or subtraction of two images with or without scaling, display of color or monochrome images, digitization of image from television camera, display of test pattern, manipulation of bits, and clearing of screen. Provides capability to read or write points, lines, and pixels from image; read or write at location of cursor; and read or write array of integers into COMTAL memory. Written in FORTRAN 77.

Faulcon, Nettie D.↗

A simplified CARS measurement system for rapid determination of temperature and oxygen concentration

A new spectroscopic concept for the rapid determination of temperature and oxygen concentration by CARS (Coherent Anti-Stokes Raman Spectroscopy) was described. The ratio of two spectral regions in the broadband Q-branch spectrum was detected by photomultipliers in a monochromator, which ratio depends on temperature and species concentration. The comparison of the measured data with theory was made using a flat flame burner and an electric furnace, with reasonable results. Various optical techniques for alignment were introduced including a highly efficient, stable dye oscillator. The combination of the spectroscopic concept and the optical techniques will make the CARS measurement system rapid in data processing and simple in optical parts.

Fujii, Shoichi↗

A Penning discharge source for extreme ultraviolet calibration

A Penning discharge lamp for use in the calibration of instruments and components for the extreme ultraviolet has been developed. This source is sufficiently light and compact to make it suitable for mounting on the movable slit assembly of a grazing incidence Rowland circle monochromator. Because this is a continuous discharge source, it is suitable for use with photon counting detectors. Line radiation is provided both by the gas and by atoms sputtered off the interchangeable metal cathodes. Usable lines are produced by species as highly ionized as Ne IV and Al V. The wavelength coverage provided is such that a good density of emission lines is available down to wavelengths as short as 100A. This source fills the gap between 100 and 300A, which is inadequately covered by the other available compact continuous radiation sources.

Finley, David S.↗

Calibration of the thin film filters to be used on the Extreme Ultraviolet Explorer Satellite

The methods of calibrating the filters used on the Extreme Ultraviolet Explorer (EUVE) astronomical satellite are described. EUVE will conduct the first all-sky survey in the entire EUV band. The measurement of the filters' transmission properties from the soft X-ray to the far UV using a grazing incidence monochromator is discussed. A particle ingress test to determine the ability of the filters to inhibit energetic particles in earth orbit from entering the detector and increasing the background is described. Problems encountered in calibrating these four filters are also presented.

Vallerga, John↗

Normal incidence reflectance of ion beam deposited SiC films in the EUV

Results are presented from an experimental investigation of the normal-incidence reflectance at 58.4, 92.0, and 121.6 nm wavelength of 30- and 80-nm-thick SiC films produced by ion-beam deposition on unheated 5 x 5-cm microscope slides. The films were deposited in the 2-m evaporator described by Bradford et al. (1969) with chamber base pressure 1 microtorr, operating pressure 40 microtorr, and a 50-62-mA 750-eV Ar ion beam; the reflectance measurements were obtained in the reflector-monochromator system described by Osantowski (1974). Reflectances of over 30 percent were found at 92 and 121.6 nm, almost equal to those of polished CVD films of SiC and degrading only slightly after aging for 4 months. It is suggested that ion-beam deposition may be the best low-temperature technique for coating EUV optics for space astronomy.

Keski-Kuha, Ritva A. M.↗

Spectrograph Measures Contamination Of Optical Elements

Scanning-monochromator spectrograph designed to measure contamination on surfaces of optical elements as function of time. Repeatedly exposes samples to environment, then measures their transmittances or reflectances over range of wavelengths. Intended for use at vacuum-ultraviolet wavelengths to evaluate effects of outgassing, heating, and cooling on optical instruments. Principle of operation also applicable to spectral monitoring of time-dependent contamination at other wavelengths and in laboratory, industrial, or other settings.

Flint, Bruce K.↗

Electronic data generation and display system

The Electronic Data Generation and Display System (EDGADS) is a field tested paperless technical manual system. The authoring provides subject matter experts the option of developing procedureware from digital or hardcopy inputs of technical information from text, graphics, pictures, and recorded media (video, audio, etc.). The display system provides multi-window presentations of graphics, pictures, animations, and action sequences with text and audio overlays on high resolution color CRT and monochrome portable displays. The database management system allows direct access via hierarchical menus, keyword name, ID number, voice command or touch of a screen pictoral of the item (ICON). It contains operations and maintenance technical information at three levels of intelligence for a total system.

Wetekamm, Jules↗

Orbital maneuvering vehicle teleoperation and video data compression

The Orbital Maneuvering Vehicle (OMV) and concepts of teleoperation and video data compression as applied to OMV design and operation are described. The OMV provides spacecraft delivery, retrieval, reboost, deboost and viewing services, with ground-control or Space Station operation, through autonomous navigation and pilot controlled maneuvers. Communications systems are comprised of S-band RF command, telemetry, and compressed video data links through the TDRSS and GSTDN networks. The control console video monitors display a monochrome image at an update rate of five frames per second. Depending upon the mode of operation selected by the pilot, the video resolution is either 255 x 244 pixels, or 510 x 244 pixels. Since practically all video image redundancy is removed by the compression process, the video reconstruction is particularly sensitive to data transmission bit errors. Concatenated Reed-Solomon and convolution coding are used with helical data interleaving for error detection and correction, and an error-containment process minimizes the propagation of error effects throughout the video image. Video sub-frame replacement is used, in the case of a non-correctable error or error burst, to minimize the visual impact to the pilot.

Jones, Steve↗

Growth and characterization of large YBa2Cu3O(7-x) single crystals

Centimeter-sized crystal plates of YBa2Cu3O(7-x) have been obtained using a bulk composition and method described by Schneemeyer at al. (1987) modified for growth in a pure oxygen atmosphere. A porous MgO crucible and long soak time promote large crystals. Mg was not detectable in the crystals. Electron microbeam analysis using a 60 A monochromator crystal for the oxygen determination gave the composition Y(1.05)Ba(2.02)Cu(2.94)O(6.52 + or - 0.06). As-grown crystals from the melt surface exhibit a fairly sharp Tc with zero resistance at 80 K, and show complex twinning and crack patterns. Optical micrographs of a lightly polished surface normal to the c-axis of a 3-mm crystal delineate twinning and fine scale microcracking; this crystal surface now has a zero resistance at 68 K. Microhardness measurements and microfracture observations indicate intrinsic properties that may inhibit or impede large scale manufacture of electronic ceramics.

Keester, Kenneth L.↗

Satellite Data Processing System (SDPS) users manual V1.0

SDPS is a menu driven interactive program designed to facilitate the display and output of image and line-based data sets common to telemetry, modeling and remote sensing. This program can be used to display up to four separate raster images and overlay line-based data such as coastlines, ship tracks and velocity vectors. The program uses multiple windows to communicate information with the user. At any given time, the program may have up to four image display windows as well as auxiliary windows containing information about each image displayed. SDPS is not a commercial program. It does not contain complete type checking or error diagnostics which may allow the program to crash. Known anomalies will be mentioned in the appropriate section as notes or cautions. SDPS was designed to be used on Sun Microsystems Workstations running SunView1 (Sun Visual/Integrated Environment for Workstations). It was primarily designed to be used on workstations equipped with color monitors, but most of the line-based functions and several of the raster-based functions can be used with monochrome monitors. The program currently runs on Sun 3 series workstations running Sun OS 4.0 and should port easily to Sun 4 and Sun 386 series workstations with SunView1. Users should also be familiar with UNIX, Sun workstations and the SunView window system.

Caruso, Michael↗

A programmable image compression system

A programmable image compression system which has the necessary flexibility to address diverse imaging needs is described. It can compress and expand single frame video images (monochrome or color) as well as documents and graphics (black and white or color) for archival or transmission applications. Through software control, the compression mode can be set for lossless or controlled quality coding; the image size and bit depth can be varied; and the image source and destination devices can be readily changed. Despite the large combination of image data types, image sources, and algorithms, the system provides a simple consistent interface to the programmer. This system (OPTIPAC) is based on the TITMS320C25 digital signal processing (DSP) chip and has been implemented as a co-processor board for an IBM PC-AT compatible computer. The underlying philosophy can readily be applied to different hardware platforms. By using multiple DSP chips or incorporating algorithm specific chips, the compression and expansion times can be significantly reduced to meet performance requirements.

Farrelle, Paul M.↗

Ames vision group research overview

A major goal of the reseach group is to develop mathematical and computational models of early human vision. These models are valuable in the prediction of human performance, in the design of visual coding schemes and displays, and in robotic vision. To date researchers have models of retinal sampling, spatial processing in visual cortex, contrast sensitivity, and motion processing. Based on their models of early human vision, researchers developed several schemes for efficient coding and compression of monochrome and color images. These are pyramid schemes that decompose the image into features that vary in location, size, orientation, and phase. To determine the perceptual fidelity of these codes, researchers developed novel human testing methods that have received considerable attention in the research community. Researchers constructed models of human visual motion processing based on physiological and psychophysical data, and have tested these models through simulation and human experiments. They also explored the application of these biological algorithms to applications in automated guidance of rotorcraft and autonomous landing of spacecraft. Researchers developed networks for inhomogeneous image sampling, for pyramid coding of images, for automatic geometrical correction of disordered samples, and for removal of motion artifacts from unstable cameras.

Watson, Andrew B.↗

Helmet-mounted pilot night vision systems: Human factors issues

Helmet-mounted displays of infrared imagery (forward-looking infrared (FLIR)) allow helicopter pilots to perform low level missions at night and in low visibility. However, pilots experience high visual and cognitive workload during these missions, and their performance capabilities may be reduced. Human factors problems inherent in existing systems stem from three primary sources: the nature of thermal imagery; the characteristics of specific FLIR systems; and the difficulty of using FLIR system for flying and/or visually acquiring and tracking objects in the environment. The pilot night vision system (PNVS) in the Apache AH-64 provides a monochrome, 30 by 40 deg helmet-mounted display of infrared imagery. Thermal imagery is inferior to television imagery in both resolution and contrast ratio. Gray shades represent temperatures differences rather than brightness variability, and images undergo significant changes over time. The limited field of view, displacement of the sensor from the pilot's eye position, and monocular presentation of a bright FLIR image (while the other eye remains dark-adapted) are all potential sources of disorientation, limitations in depth and distance estimation, sensations of apparent motion, and difficulties in target and obstacle detection. Insufficient information about human perceptual and performance limitations restrains the ability of human factors specialists to provide significantly improved specifications, training programs, or alternative designs. Additional research is required to determine the most critical problem areas and to propose solutions that consider the human as well as the development of technology.