Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isolation protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Treadmill Exercise with Increased Body Loading Enhances Post Flight Functional Performance

The goals of the Functional Task Test (FTT) study were to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. Ultimately this information will be used to assess performance risks and inform the design of countermeasures for exploration class missions. We have previously shown that for Shuttle, ISS and bed rest subjects functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. These changes in functional performance were paralleled by similar decrements in sensorimotor tests designed to specifically assess postural equilibrium and dynamic gait control. The bed rest analog allows us to investigate the impact of axial body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance and then compare them with the results obtained in our space flight study. These results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. Given the importance of body-support loading we set out to determine if there is a relationship between the load experienced during inflight treadmill exercise (produced by a harness and bungee system) and postflight functional performance. ISS crewmembers (n=13) were tested using the FTT protocol before and after 6 months in space. Crewmembers were tested three times before flight, and on 1, 6, and 30 days after landing. To determine how differences in body-support loading experienced during inflight treadmill exercise impacts postflight functional performance, the loading history for each subject during inflight treadmill (T2) exercise was correlated with postflight measures of performance. Crewmembers who walked on the treadmill with higher pull-down loads had less decrement in postflight postural stability and dynamic locomotor control than those subjects who exercised with lighter loads. These data point to the importance of providing significant body loading during inflight treadmill exercise. This and the addition of specific balance training may further mitigate decrements in critical mission tasks that require dynamic postural stability and mobility. Inflight treadmill exercise provides a multi-disciplinary platform to provide sensorimotor, aerobic and bone mechanical stimuli benefits. Forward work will focus on the development of an inflight training system that will integrate aerobic, resistive and balance training modalities into a single interdisciplinary countermeasure system for exploration class missions.

Bloomberg, J. J.↗

Technology Applicable to Remote Hazardous Constituents and Waste Stream Grouping

Originally, Rocky Flats transuranic (TRU) waste was managed from waste streams that were composed of similar chemical constituents and were generated from identical processes. Early waste processing at Idaho National Laboratory (INL) maintained the Rocky Flats record until INL began generating their own item description codes (IDCs). Ultimately TRU waste management at INL was driven to combine wastes from all IDCs that were assigned by Rocky Flats to a summary category group regardless of whether the chemical constituents in the waste were known or not. At this point, the Waste Isolation Pilot Plant (WIPP) certified program requirements to process the TRU waste according to waste streams was nearly eliminated. In April 2018, operations in the Sludge Repackage Project (SRP) area were halted by a radiological materials release accident in which drums containing waste experienced a loss of containment after over-pressurization occurred. Four SRP drums, repackaged in the Accelerated Retrieval Project (ARP) V area, had an adverse, delayed chemical reaction event occur when prohibited materials from one container were mixed with chemically-incompatible materials from other containers in the repackaging process. This incident was the direct result of processing unknowns under a protocol where the components of the waste were added to incompatible materials resulting in a run-away reaction. After a Difficult Waste Team (DWT) and Los Alamos National Laboratory – Carlsbad Operations (LANL-CO) subject matter expert (SME) visit in September 2019, it was determined by the team that all of the work observed on the September visit was performed upstream of the certified program and that the Visual Examination (VE) and other methods typically used by the certified program were being used for Acceptable Knowledge (AK) augmentation. This augmentation was needed in order to determine what the constituents in the waste might be, and is based primarily on collections of VE results. The waste at INL that is being processed in what is considered to be the Priority 2 (yellow) and Priority 3 (red) lists either needs AK to be completed before certified characterization can occur or is waiting to be processed because the waste has been mixed with unknown wastes resulting in a lack of information that could have impact of the ability to certify and ship the waste to the WIPP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A hierarchically distributed architecture for fault isolation expert systems on the space station

The Space Station Axiomatic Fault Isolating Expert Systems (SAFTIES) system deals with the hierarchical distribution of control and knowledge among independent expert systems doing fault isolation and scheduling of Space Station subsystems. On its lower level, fault isolation is performed on individual subsystems. These fault isolation expert systems contain knowledge about the performance requirements of their particular subsystem and corrective procedures which may be involved in repsonse to certain performance errors. They can control the functions of equipment in their system and coordinate system task schedules. On a higher level, the Executive contains knowledge of all resources, task schedules for all systems, and the relative priority of all resources and tasks. The executive can override any subsystem task schedule in order to resolve use conflicts or resolve errors that require resources from multiple subsystems. Interprocessor communication is implemented using the SAFTIES Communications Interface (SCI). The SCI is an application layer protocol which supports the SAFTIES distributed multi-level architecture.

Miksell, Steve↗

Real-time evaluation of cybersecurity threats to DER inverter grid-support functions

In this project we aim to contribute to the understanding of the type and severity of potential cybersecurity attacks to the grid-support functionalities of DER systems interconnected to the AC distribution grid via inverters. Our preliminary work focused on developing a small-scale testbed allowing to study cybersecurity threats to an isolated photovoltaic-battery system using a real-time simulator (Typhoon HIL602+) with a real DNP3 communication connection over TCP/IP, allowing for safe and efficient monitoring and manipulation of data traffic between the simulated hardware and supervisory control and data acquisition (SCADA) system. In this project we propose to expand upon this development by utilizing a) a recently acquired NovaCor RTDS (Real Rime digital Simulator) to emulate the DER-inverter-grid topology including main grid-support functions as defined by IEEE Std. 1547-2018, and b) an industrial control and automation device to enable realistic evaluation of control functions and utilization of communication protocols for real-time data transmission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bridging Control and Deployment: A Cross-Layer Analysis of Scalable Building Cluster Control

Building cluster control has emerged as a promising approach for enabling flexible and coordinated operation of distributed building systems, yet its transition from pilot demonstrations to routine grid-interactive operation remains limited. This paper argues that this gap cannot be explained by control algorithms alone. Instead, it arises from interacting barriers in communication infrastructure, data and semantic interoperability, uncertainty management, stakeholder participation, market design, and policy support. Accordingly, the paper reviews both technical and non-technical barriers to building cluster control. Technical challenges include heterogeneous devices and protocols, communication latency and reliability, distributed decision-making, and uncertainty propagation across aggregated loads. Non-technical barriers include user participation, stakeholder coordination, incentive allocation, and data governance. Existing solution approaches are synthesized, including semantic interoperability frameworks, edge and hierarchical communication architectures, distributed and transactive control strategies, uncertainty-aware optimization, policy mechanisms, and market reforms. Based on this analysis, two research directions are identified: testing infrastructures that can evaluate control performance under realistic multi-building conditions, and abstraction methods that allow building clusters to interact with other energy sectors through standardized flexibility representations. Overall, the paper provides a structured review of how building cluster control can move from isolated demonstrations toward reproducible, market-compatible, and grid-relevant implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Pressure Long-Term Xenon Storage for Electric Propulsion

This Phase 2 effort demonstrated an alternative Xe storage and regulation system using activated carbon (AC) as a secondary storage media (ACSFR). This regulator system is nonmechanical, simple, inexpensive, and lighter. The ACSFR system isolates the thruster from the compressed gas tank, and allows independent multiple setpoint thruster operation. The flow using an ACSFR can also be throttled by applying increments in electrical power. Primary storage of Xe by AC is not superior to compressed gas storage with regard to weight, but AC storage can provide volume reduction, lower pressures in space, and potentially in situ Xe purification. With partial fill designs, a primary AC storage vessel for Xe could also eliminate problems with two-phase storage and regulate pressure. AC could also be utilized in long-term large quantity storage of Xe serving as a compact capture site for boil-off. Several Xe delivery ACSFR protocols between 2 and 45 sccm, and 15 min to 7 hr, were tested with an average flow variance of 1.2 percent, average power requirements of 5 W, and repeatability s of about 0.4 percent. Power requirements are affected by ACSFR bed sizing and flow rate/ duration design points, and these flow variances can be reduced by optimizing PID controller parameters.

Back, Dwight D.↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation: Preprint

Utilities have been installing microgrids due to the advancements in the distributed energy resources technologies. Microgrids also improve the resiliency of the system due to their capability to isolate themselves from the grid and run in islanded mode of operation. Microgrid controllers are management systems that can run the microgrids under varied operating condition and enable the smooth operation of microgrids under various system conditions. It is of high value to de-risk the installation of such controllers. Hardware-in-the-loop evaluation is used by controller developers and utilities to evaluate the controllers under stressful conditions to understand the performance and to understand the necessary improvements to the microgrid controller. In this research work, the team has leveraged the existing infrastructure of real-time simulation at the Energy Systems Integration Facility (ESIF) and the capability of the microgrid controller to control assets over the Internet Protocol (IP) to evaluate a university developed microgrid controller in an efficient and cost-effective manner. The full paper will provide the complete setup, the experimental use cases and the results. In this abstract, one use case will be expalined, and the results from the use case is provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Molecular Identification of Microbial Contaminants

Microorganisms can have significant impacts on the success of NASA’s missions, including the integrity of materials, the reliability of scientific results, and maintenance of crew health. Robust cleaning and sterilization protocols are currently in place in NASA facilities, but agency experts agree that microbial contamination is unavoidable and its impact on NASA’s missions and science must be minimized. Therefore, it is critical to understand: 1) what specific microorganisms are present, 2) how they may impact scientific objectives, and 3) how to select appropriate mitigation strategies. The Marshall Space Flight Center (MSFC) Planetary Protection (PP) microbiology lab historically relied solely upon enumeration of culturable microbial contamination associated with spacecraft materials or cleanrooms. However, this process is time consuming, many microbes cannot be cultured, and very few can be identified with any fidelity using NASA standard microbiological methods. The work described in this white paper includes the establishment of molecular identification capabilities at MSFC, including DNA isolation, amplification, purification, and Sanger sequencing. This capability will not only improve planetary protection efforts at MSFC (i.e. by identifying contaminating microorganisms in cleanrooms or on spacecraft) but also offers a service center-wide for the identification of contaminants that arise in other projects, processing locations, or during set up and roll out of spacecraft. This work also lays the foundation for higher throughput efforts to identify large populations of microbes across the lifetime of a project and serves as the starting point for future work into whole genome sequencing, non-culture based methods, or additional characterization studies. Ultimately, accurate identification informs appropriate mitigation strategies, increasing the chances of success for NASA’s missions and objectives.

C. D. Cassilly↗

Towards generic memory forensic framework for programmable logic controllers

A Programmable Logic Controller (PLC) is a microprocessor-based controller that is used to automate physical processes in critical infrastructure and various other industries and manufacturing sectors. Initially, PLCs were completely isolated from the Internet, and cyber security was not incorporated at the time of development. The introduction of industry 4.0 and the evolution of ICS systems to communicate over public IP addresses from the Internet enhanced productivity and efficiency, but Internet connectivity exposed the systems and their vulnerabilities, which led to an increase in cyber attacks. When a system is sabotaged/compromised, security analysts need to get to the root cause of the attack as quickly as possible to recover the system. To do so, memory forensic analysis is critical to provide a unique insight into the run-time memory activities and extract a reliable source of evidence. In this paper, we analyze the memory structure of the Schneider Electric Modicon M221 PLC. To build a memory profile, we reverse engineer the communication protocol and conduct differential analysis to gain knowledge about the structure of the memory and the low-level representation of control logic instructions. We then identify dynamic and static memory regions by modifying different project fields and conducting differential analysis, which allows us to identify boundaries of critical memory structures and extract important forensic artifacts that can be found in the memory. The Python implementation of the memory profile can help reduce the time and effort required for manual analysis in case of cyber incident or system failure.

97 MATHEMATICS AND COMPUTING↗

A Data Exchange Interface for a Standards Based Data Integration Platform

The modern electrical grid is a complex and a data rich system, requiring several sub-systems to provide the capability and support needed to perform functions such as distributed energy resource management, outage management, and fault location and isolation, to name a few. There is a need to develop software solutions and platforms that provide an integrated infrastructure to allow interoperability between these subsystems, while leveraging the abundant data available from today’s grid. In this paper, we present the development and deployment of an application service to integrate GridAPPS-D which is an open source, standards-based software platform with SurvalentONE, a commonly used DNP3 based ADMS platform that allows operation, monitoring, analysis, restoration, and optimization of network operations. We present details of the integration architecture, including its implementation, and provide results from functional testing of the architecture on a 13 bus IEEE system. The results validate that the integration is successful and is able to provide a two-way exchange of communication and translation between different communication protocols.

Singh, Alka↗

Determining Partial Atomic Charges for Liquid Water: Assessing Electronic Structure and Charge Models

Partial atomic charges provide an intuitive and efficient way to describe the charge distribution and the resulting intermolecular electrostatic interactions in liquid water. Many charge models exist and it is unclear which model provides the best assignment of partial atomic charges in response to the local molecular environment. In this work, we systematically scrutinize various electronic structure methods and charge models (Mulliken, natural population analysis, CHelpG, RESP, Hirshfeld, Iterative Hirshfeld, and Bader) by evaluating their performance in predicting the dipole moments of isolated water, water clusters, and liquid water as well as charge transfer in the water dimer and liquid water. Although none of the seven charge models is capable of fully capturing the dipole moment increase from isolated water (1.85 D) to liquid water (about 2.9 D), the Iterative Hirshfeld method performs best for liquid water, reproducing its experimental average molecular dipole moment, yielding a reasonable amount of intermolecular charge transfer, and showing modest sensitivity to the local water environment. The performance of the charge model is dependent on the choice of the density functional and the quantum treatment of the environment. The computed molecular dipole moment of water generally increases with the percentage of the exact Hartree–Fock exchange in the functional, whereas the amount of charge transfer between molecules decreases. For liquid water, including two full solvation shells of surrounding water molecules (within about 5.5 Å of the central water) in the quantum chemical calculation converges the charges of the central water molecule. Furthermore, our final pragmatic quantum chemical charge-assigning protocol for liquid water is the Iterative Hirshfeld method with M06-HF/aug-cc-pVDZ and a quantum region cutoff radius of 5.5 Å.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pharmacokinetics, Metabolite Measurement, and Biomarker Identification of Dermal Exposure to Permethrin Using Accelerator Mass Spectrometry

Impregnating military uniforms and outdoor clothing with the insecticide permethrin is an approach to reduce exposure to insect borne diseases and to repel pests and disease vectors such as mosquitos and sandflies, but the practice exposes wearers to prolonged dermal exposure to the pesticide. Key metabolite(s) from a low dose dermal exposure of permethrin were identified using accelerator mass spectrometry. Metabolite standards were synthesized and a high performance liquide chromatography (HPLC) elution protocol to separate individual metabolites in urine was developed. Six human subjects were exposed dermally on the forearm to 25 mg of permethrin containing 1.0 µCi of 14 C for 8 h. Blood, saliva and urine samples were taken for 7d. Absorption/elimination rates and metabolite concentrations varied by individual. Average absorption was 0.2% of the dose. Serum concentrations rose until 12–24 h postdermal application then rapidly declined reaching predose levels by 72 h. Maximum saliva excretion occurred 6 h postdosing. The maximum urinary excretion rate occurred during 12–24 h; average elimination half-life was 56 h. 3-Phenoxybenzyl alcohol glucuronide was the most abundant metabolite identified when analyzing elution fractions, but most of the radioactivity was in still more polar fractions suggesting extensive degradative metabolism and for which there were no standards. Finally, analyses of archived urine samples with the ultra performance liquid chromatography-accelerator mass spectrometry-mass spectrometry (UPLC-AMS-MS) system isolated a distinct polar metabolite but it was much diminished from the previous analyses a decade earlier.

59 BASIC BIOLOGICAL SCIENCES↗

Multidecadal Changes in Lower Stratospheric Ozone: Variability Vs. Trends

As upper stratospheric ozone appears to be recovering as a result of decreasing chlorine loading following the implementation of the Montreal Protocol and its amendments and in agreement with model projections, several recent studies report an apparent decline of ozone concentrations in the lower stratosphere in the last two decades, particularly in the extratropics. Our previous work as well as at least two other studies provide evidence that this decline results from transport changes rather than an intensification of chemical depletion. It remains unclear whether these changes represent long-term internal variability or are a consequence of a climate forcing. Here we perform free-running ensembles of the recent past (1980-2016) using the Goddard Earth Observing System Model (GEOS) at the cubed sphere C180 (approximately half degree) resolution. Two suites of 10-member ensembles are performed, one in which observed sea surface temperature (SSTs) are fully prescribed, and the other in which the linear SST trend over the recent past is removed so as to only retain internal variability. We evaluate the trends in both ozone as well as two idealized tracers with prescribed uniform loss that are used to isolate the role of transport from chemistry and emissions. Probability-distribution-functions of the trends in both ozone and idealized tracers are compared among ensemble members and with observed trends in order to evaluate the likelihood of recent observed declines in lower stratospheric ozone, relative to large internal variability. Moreover, comparisons among simulations with and without imposed SST trends indicate the extent to which dynamically-driven ozone trends reflect forced trends or internal variability in lower stratospheric dynamics.

Wargan, Krzysztof↗

Radiation Hardened Foam Cold Test Plan – Phase-I: Foam Adhesion, Contamination Fixation, Moisture Stresses, Pipe Cutting, and Thermal Profile Testing

This document outlines the Phase-I test objectives and implementation plan for a down-selective foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of an intumescent, fire-retardant foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed in FIU’s Outdoor Test and Evaluation Facility using a mock-up that replicates the operational conditions at the proposed hot test location at F/H labs. Results from the cold test plan will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the site and transported to a proper disposal facility. Phase-I testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of foam fixative in piping, (2) evaluation of the adhesion of the foam fixative in piping under varying moisture conditions, (3) determination of the heat profile of the foam fixative during curing, (4) determination of the relationship between pipe diameter and foam fixative quantity, (5) determination of the internal pipe pressure after foam deployment and curing, (6) development of a leak test standard operating procedure to test for the effectiveness of the foam plug, (7) initiation of a literature review to determine if using a hot tap is a viable method to deliver foam into piping, and (8) initiation of a 10-foot mock up test that will be used in Phase-II cold testing. The cold test will be conducted at FIU and all testing activities will comply with SRNL Conduct of R&D Protocols (SRNL-IM-2020-00019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Expanding Ketamine Application for Treatment of Acute Suicidality in Long-Duration Spaceflight

Introduction. The transition to exploration missions places a heightened risk on behavioral health in spaceflight. Although serious psychiatric emergencies during spaceflight have been rare, longer duration missions increase the possibility of emergence in latent mental health disorders due to genetic predisposition, increased autonomy, isolation, helplessness, loss of family member, or catastrophic events. Complicated grief and bereavement have the highest rate of suicidal ideation. Recently, ketamine has been used as an emergent intervention for acute suicidality, promoting its stability, ease of administration, favorable safety profile, and outcomes for reduction of suicidal intent. The goal of this study was to review current literature and collate the understanding of ketamine as a safe, effective pharmacological adjunct for acute suicidality in spaceflight. Methods. This literature review was conducted to collate data on ketamine use for acute suicidality and inform on stability, limitations and utilization of ketamine within extreme environments. Results. 122 publications were reviewed for relevance including 23 randomized-control trials for ketamine use in behavioral emergencies. Discussion. Ketamine is a diverse pharmaceutical with multiple advantageous indications, including acute suicidality, pain, and sedation. Terrestrial use of ketamine suggests a rapidly efficacious medication for reduction in acute suicidality. As behavioral stressors expand related to extended missions, contingencies for behavioral emergencies become increasingly important. Although this review is not intended to re-develop current International Space Station (ISS) protocols, it is the first to discuss the benefits of ketamine in spaceflight as a potential safe, effective multifaceted tool for future exploration missions and treatment for acute suicidal ideation.

Ketamine, Suicidality, Spaceflight↗

Effect of second Si–O vibrational overtones/combinations on quantifying water in silicate and silica minerals using infrared spectroscopy, and an experimental method for its removal

Infrared spectroscopy (IR) is the most widely used analytical tool to quantify trace water in silicate and silica minerals. A prerequisite for highly accurate IR measurements of trace water is a good understanding of the effect of the second Si–O vibrational overtones/combination bands (2nd Si–O VOCBs) on the water peaks. Silicate and silica minerals can be divided as isolated (Q 0 ), paired (Q 1 ), ring (Q 2 ), chain (Q 1 or Q 2 ), sheet (Q 3 ) and framework (Q 4 ) structures according to the polymerization of their SiO 4 tetrahedral units, and the 2nd Si–O VOCBs of these different structural types attain different vibrational features which are expected to affect the water peaks to different extents. Here, we selected olivine (Q 0 ) and α-quartz (Q 4 ) as two endmember-like structural examples, performed extensive IR measurements on both pristine and heat-treated thin sections prepared for these two minerals, and explored the vibrational features of the 2nd Si–O VOCBs. In this work, we have found that the 2nd Si–O VOCBs are well separated from the water peaks in olivine, but severely overlap with the water peaks in α-quartz, confirming the different roles that the 2nd Si–O VOCBs play in quantifying trace water in silicate and silica minerals with different structural polymerizations. To remove the influence of the 2nd Si–O VOCBs (or any other species rather than water), an experimental protocol has been successfully developed, as approved by some fundamental equations and verified by the data of α-quartz in the literature. This development should lead to significant accuracy improvement in quantifying trace amounts of water in Earth and planetary materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploration Medical Capability Clinical Decision Support Use Cases for CDSS Test Bed

Long-duration, deep-space exploration missions present significant challenges to crew health and performance. These challenges include the individual and combined effects of microgravity, radiation exposure, isolation, limited resources (mass, volume, power, data, and crew time), limited options for evacuation, and those associated with delayed or constrained communications. Each of these challenges necessitates greater degrees of crew autonomy as our distance from Earth increases. Specifically, as communication delays intensify - and evacuation capability diminishes the further we explore space - the unqualified need for Earth-independent medical operations focused on autonomous diagnosis, treatment and prevention will become key to mission continuation and success. This need will be especially true should a crewmember become ill or injured wherein treatment and disposition “in-situ” ultimately falls to the crew itself to determine. To augment the requisite knowledge, skills, and abilities (KSAs) of a time-constrained exploration mission crew operating under stressful conditions, combatting fatigue, and facing a potential medical crisis, a robust clinical decision support system (CDSS) is a probable solution. A CDSS would facilitate, guide, and inform Earth-independent medical operations while assisting crewmembers through various clinical presentations. The CDSS would allow crewmembers to take advantage of pre-mission training tied to the in-flight/in-mission use of pre-planned protocols that offer both a range of diagnostic options and “just-in-time” (refamiliarization) training and assistance. CDSS will expand such capabilities by improving the utility and effectiveness of various available diagnostic, treatment, and health maintenance tools, techniques, and measures.

ExMC↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗