Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A Study of Breakdown Limits in Microstrip Gas Counters with Preamplification Structures

We have studied the charge and breakdown limits of Microstrip Gas Counters (MSGCs) with 2 different preamplification structures: the Gas Electron Multiplier (GEM) and the Parallel-Plate Avalanche Counter (PPAC). It was found that in both cases the breakdown limit was increased by 1-2 orders of magnitude compared to the bare MSGC that this is due to the spread of the primary electron cloud during pre-amplification. This spreading reduces the charge density in the final MSGC avalanche, permitting much higher total gains before streamers form. The real practical gain limitations in these two-stage detectors arose not from sparking, but from a loss of proportionality due to space charge effects.

Fonte, P.↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗

Fabrication of a focusing soft X-ray collector payload

A large area X-ray focusing collector with arc minute resolution and a position sensitive detector capable of operating in the soft X-ray region was developed for use on sounding rockets in studying stellar X-ray sources. The focusing payload consists of the following components, which are described: (1) a crossed paraboloid mirror assembly; (2) an aspect camera and star tracker; (3) a focal plane assembly containing an imaging proportional counter and its preamplifiers, high voltage power supplies and gas system; (4) a fiducial system; and (5) housekeeping, data handling, instrumentation and telemetry electronics. The design, tests, and operation are described.

Davis, J. M.↗

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.↗

Micromachined electron tunneling infrared sensors

The development of an improved Golay cell is reported. This new sensor is constructed entirely from micromachined silicon components. A silicon oxynitride (SiO(x)N(y)) membrane is deflected by the thermal expansion of a small volume of trapped gas. To detect the motion of the membrane, an electron tunneling transducer is used. This sensor detects electrons which tunnel through the classically forbidden barrier between a tip and a surface; the electron current is exponentially dependent on the separation between the tip and the surface. The sensitivity of tunneling transducers constructed was typically better than 10(exp -3) A/square root of Hz. Through use of the electron tunneling transducer, the scaling laws which have prevented the miniaturization of the Golay cell are avoided. This detector potentially offers low cost fabrication, compatibility with silicon readout electronics, and operation without cooling. Most importantly, this detector may offer better sensitivity than any other uncooled infrared sensor, with the exception of the original Golay cell.

Kenny, T. W.↗

The University of Chicago cosmic ray electrons and nuclei experiment on the H spacecraft

The University of Chicago instrument on the Heliocentric spacecraft (MEH experiment) will measure the energy spectrum of cosmic electrons in the range 5-400 MeV. In addition, the energy spectra and relative abundances of nuclei from protons to the iron group, with energies ranging from 30 MeV/n to 15 GeV/n, will be determined. Primary scientific objectives involve the study of the long and short term variability of these components as a probe of the structure of the heliosphere. Particles are identified by multiparameter analysis using the pulse height analyzed signals from eight active detectors - silicon solid state, plastic and crystal scintillators are solid and gas Cerenkov counters. Data return is optimized by a three level priority logic scheme.

Meyer, P.↗

Soft X-ray bremsstrahlung and fluorescent line production in the atmosphere by low energy electrons

The effect of low energy quasi-trapped or precipitating electrons which impact on the counter windows of soft X-ray detectors are discussed. The errors caused by X-rays produced in the residual atmosphere above a rocket-borne detector because of the resemblance to X-rays of cosmic origin are examined. The design and development of counter windows which make it possible to identify the atmospherically produced X-rays are described. Curves are presented to show the following: (1) preliminary low energy electron data from Atmospheric Explorer C, (2) X-ray flux in electron-excited nitrogen and oxygen, (3) typical proportional counter response to low energy cosmic rays, and (4) proportional counter response to X-radiation produced by electrons incident upon a gas of oxygen to nitrogen number of 0.4.

Kraushaar, W. L.↗

Prototype X-ray and Gamma Detection with Cyclotron Radiation Emission Spectroscopy

Cyclotron radiation emission spectroscopy, or CRES, is a novel approach to measuring the energy of an electron. By trapping a free electron in a high magnetic field, it undergoes cyclotron motion and emits radiofrequency (RF) waves. The frequency of this RF radiation is directly related to the energy of the electron. Because many cycles of the RF emission are recorded, the energy resolution of the CRES system is on the order of a single electron volt. To make a CRES system sensitive to photons, a target gas is used to induce a photoelectric effect, producing the electron that is subsequently trapped. By adding the binding energy of the target atom, the energy of the incident photon may be reconstructed. Using a xenon target gas, photoelectric interactions dominate up to approximately 300 keV, covering not only all atomic shell X-rays of the elements, but many low-lying nuclear states as well, including key transuranic elements related to nuclear security. CRES holds the potential of maintaining single-eV resolution up to this 300-keV range, thereby surpassing current state-of-the-art detectors by a factor of 10-100. The instrumental resolution of the system is limited by the uniformity of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Science Symposium, 29th, and Symposium on Nuclear Power, 14th, Washington, DC, October 20-22, 1982, Proceedings

High-energy radiation detectors suitable for balloon-borne or space-based radiation event studies are described. The employment of NaI(Tl) scintillator bars for gamma ray detection is outlined, and the development of a fluorescent gated gas-filled scintillation proportional counter is reported. A high throughput nondispersive hard X ray spectrograph with angular resolution for cosmic bursts, transients, and sources has been constructed. Features of a sealed high pressure xenon filled imaging proportional counter with a 30 sq cm sensitive area are explored. Finally, the various radiation effects on electronic circuitry in a space environment are defined, and an MOS dosimeter for assaying the cumulative radiation flux in a spacecraft due to ambient conditions is characterized.

Davis, W. D.↗

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗

Laboratory Simulation of Impacts upon Aluminum Foils of the Stardust Spacecraft: Calibration of Dust Particle Size from Comet Wild 2

Metallic aluminium alloy foils exposed on the forward, comet-facing surface of the aerogel tray on the Stardust spacecraft are likely to have been impacted by the same cometary particle population as the dedicated impact sensors and the aerogel collector. The ability of soft aluminium alloy to record hypervelocity impacts as bowl-shaped craters offers an opportunistic substrate for recognition of impacts by particles of a wide potential size range. In contrast to impact surveys conducted on samples from low Earth orbit, the simple encounter geometry for Stardust and Wild 2, with a known and constant spacecraft-particle relative velocity and effective surface-perpendicular impact trajectories, permits closely comparable simulation in laboratory experiments. For a detailed calibration programme we have selected a suite of spherical glass projectiles of uniform density and hardness characteristics, with well-documented particle size range from 10 microns to nearly 100 microns. Light gas gun buckshot firings of these particles at approximately 6km s)exp -1) onto samples of the same foil as employed on Stardust have yielded large numbers of craters. Scanning electron microscopy of both projectiles and impact features has allowed construction of a calibration plot, showing a linear relationship between impacting particle size and impact crater diameter. The close match between our experimental conditions and the Stardust mission encounter parameters should provide another opportunity to measure particle size distributions and fluxes close to the nucleus of Wild 2, independent of the active impact detector instruments aboard the Stardust spacecraft.

Kearsley, A. T.↗

Chemochromic Detector for Sensing Gas Leakage and Process for Producing the Same

A chemochromic sensor for detecting a combustible gas, such as hydrogen, includes a chemochromic pigment and a textile polymer. The textile material includes a chemochromic pigment operably responsive to a combustible gas. The combustible gas sensing textile material can be made by melt spinning, solution spinning, or other similar techniques. In a preferred embodiment carbon nanotubes are used with the textile material which will increase the material strength and alter the thermal and/or electrical properties. These textiles woven into fabrics can provide garments not only with hydrogen sensing capabilities but the carbon nanotubes will allow for a range of sensing capabilities to be embedded (i.e. gas, health, and electronic monitors) within the garments.

Roberson, Luke B.↗

Miniature Gas Chromatograph (GC): Penning Ionization Electron Spectroscopy (PIES) Instrument for the Trace Analyses of Extraterrestrial Environments

In situ exploration of the solar system to identify its early chemistry as preserved in icy bodies and to look for compelling evidence of astrobiology will require new technology for chemical analysis. Chemical measurements in space flight environments highlight the need for a high level of positive identification of chemical compounds, since re-measurement by alternative techniques for confirmation will not be feasible. It also may not be possible to anticipate all chemical species that are observed, and important species may be present only at trace levels where they can be masked by complex chemical backgrounds. Up to now, the only techniques providing independent sample identification of GC separated components across a wide range of chemical species have been Mass Spectrometry (MS) and Ion Mobility Spectrometry (IMS). We describe here the development of a versatile and robust miniature GC detector based on Penning Ionization Electron Spectroscopy (PIES), for use with miniature GC systems being developed for planetary missions. PIES identifies the sample molecule through spectra related to its ionization potential. The combination of miniature GC technology with the primary identification capabilities of PIES provides an analytical approach ideal for planetary analyses.

Kojiro, Daniel R.↗

NASA Tech Briefs, January 2008

Topics covered include: Induction Charge Detector with Multiple Sensing Stages; Generic Helicopter-Based Testbed for Surface Terrain Imaging Sensors; Robot Electronics Architecture; Optimized Geometry for Superconducting Sensing Coils; Sensing a Changing Chemical Mixture Using an Electronic Nose; Inertial Orientation Trackers with Drift Compensation; Microstrip Yagi Antenna with Dual Aperture-Coupled Feed; Patterned Ferroelectric Films for Tunable Microwave Devices; Micron-Accurate Laser Fresnel-Diffraction Ranging System; Efficient G(sup 4)FET-Based Logic Circuits; Web-Enabled Optoelectronic Particle-Fallout Monitor; SiO2/TiO2 Composite for Removing Hg from Combustion Exhaust; Lightweight Tanks for Storing Liquefied Natural Gas; Hybrid Wound Filaments for Greater Resistance to Impacts; Making High-Tensile-Strength Amalgam Components; Bonding by Hydroxide-Catalyzed Hydration and Dehydration; Balanced Flow Meters without Moving Parts; Deflection-Compensating Beam for Use inside a Cylinder; Four-Point-Latching Microactuator; Curved Piezoelectric Actuators for Stretching Optical Fibers; Tunable Optical Assembly with Vibration Dampening; Passive Porous Treatment for Reducing Flap Side-Edge Noise; Cylindrical Piezoelectric Fiber Composite Actuators; Patterning of Indium Tin Oxide Films; Gimballed Shoulders for Friction Stir Welding; Improved Thermal Modulator for Gas Chromatography; Nuclear-Spin Gyroscope Based on an Atomic Co-Magnetometer; Utilizing Ion-Mobility Data to Estimate Molecular Masses; Optical Displacement Sensor for Sub-Hertz Applications; Polarization/Spatial Combining of Laser-Diode Pump Beams; Spatial Combining of Laser-Diode Beams for Pumping an NPRO; Algorithm Optimally Orders Forward-Chaining Inference Rules; Project Integration Architecture; High Power Amplifier and Power Supply; Estimating Mixing Heights Using Microwave Temperature Profiler; and Multiple-Cone Sunshade for a Spaceborne Telescope.

Source record↗

Low-loss Si-based Dielectrics for High Frequency Components of Superconducting Detectors

Silicon-based dielectric is crucial for many superconducting devices, including high-frequency transmission lines, filters, and resonators. Defects and contaminants in the amorphous dielectric and at the interfaces between the dielectric and metal layers can cause microwave losses and degrade device performance. Optimization of the dielectric fabrication, device structure, and surface morphology can help mitigate this problem. We present the fabrication of silicon oxide and nitride thin film dielectrics. We then characterized them using Scanning Electron Microscopy, Atomic Force Microscopy, and spectrophotometry techniques. The samples were synthesized using various deposition methods, including Plasma-Enhanced Chemical Vapor Deposition and magnetron sputtering. The film's morphology and structure were modified by adjusting the deposition pressure and gas flow. The resulting films were used in superconducting resonant systems consisting of planar inductors and capacitors. Measurements of the resonator properties, including their quality factor, were performed.

low-loss dielectrics↗

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O↗

The neutral mass spectrometer on Dynamics Explorer B

A neutral gas mass spectrometer has been developed to satisfy the measurement requirements of the Dynamics Explorer mission. The mass spectrometer, a quadrupole, will measure the abundances of neutral species in the region 300-500 km in the earth's atmosphere. These measurements will be used in concert with other simultaneous observations on Dynamics Explorer to study the physical processes involved in the interactions of the magnetosphere-ionosphere-atmosphere system. The instrument, which is similar to that flown on Atmosphere Explorer, employs an electron beam ion source operating in the closed mode and a discrete dynode multiplier as a detector. The mass range is 22 to 50 amu. The abundances of atomic oxygen, molecular nitrogen, helium, argon, and possibly atomic nitrogen will be measured to an accuracy of about + or - 15% over the specified altitude range, with a temporal resolution of one second.

Carignan, G. R.↗

Noble Liquid Test Facility at Fermilab

The Noble Liquid Test Facility (NLTF) at Fermilab is a liquid argon detector R\&D facility open to the national and international HEP community. The facility consists of 4 permanent cryostats, ranging from 250L up to 3000L, open space for small open dewar testing, and an optical test stand facility capable of measuring the optical properties of materials and characterizing photon detectors. NLTF’s strongest advantage is its capability to provide ultra-pure LAr in a reliable manner. Its inline filters are capable of filtering all of the three biggest contaminants for standard LAr detectors, O$_2$ and H$_2$O down to $< 1$ppb and N$_2$ $< 1$ppm. This is critical for the users of the test stands as small levels of impurities can dramatically change the efficiency of LArTPCs for the collection of charge and light. The smallest cryostat is mainly used for material testing, a service provided to the international HEP community interested in understanding how the introduction of a specific material might affect the electron lifetime in LAr. The test stands can be equipped with a purity monitor, which allows measuring the electron lifetime in real time, as well as gas sampling and analyzing, and in the near future, local recirculation and filtering. The facility has hosted many successful R\&D projects, which have published their results in well-known journals and talks. A few examples of such projects are: NIR light production in LAr and GAr, the characterization of VUV metalenses, the testing of new filter media capable of filtering N$_2$ from LAr, high voltage studies and direct charge amplification in LAr, and various doping studies.

Blaszczyk, Flor María [Fermilab]↗