Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dc power systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Dynamically robust coordinated set point tracking of distributed DERs at point of common coupling

Low-inertia operation of small-scale power systems, such as a microgrid or a portion of a long feeder, requires careful coordination of the controller performance of the constituting devices. This challenge is exacerbated in microgrids serving the functionalities of a conventional synchronous-based generation unit while comprised of smaller DERs operating mainly interfaced through power electronics converters. This paper builds on the idea of set point modulation and proposes a two-level control strategy that aims to achieve superior performance at the point of common coupling (PCC) of microgrids by combining a local control level with a distributed and coordinated level. Several case studies on both AC and DC systems, the CIGRE low-voltage benchmark system as the AC system and a test DC microgrid, validate the performance of the proposed approach. The real-world applicability of the approach is established via a high-fidelity power hardware-in-the-loop (PHIL) experimental setup and an application case study on grid frequency regulation. The proposed approach enables a microgrid to participate in ancillary service provisions where speed and quality of regulation are critical.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Electronic Development Challenges for High Power Density Integrated Electric Drive Applications

The ever-increasing demand for compact, efficient, and high-performance traction drive systems for transportation applications has accelerated the development of integrated electric drives. In these systems, the electric machine and inverter are integrated within a single housing, offering significant advantages in electrical performance, volume, weight, cost, and overall system efficiency. Despite these benefits, such high levels of integration introduce a new set of challenges, particularly in power electronic design and component selection. This article presents an in-depth investigation of a highly integrated electric drive architecture with an internal stator-mounted inverter, highlighting key design considerations and trade-offs aimed exclusively at maximizing system power density.Based on a comprehensive review of the literature, the power density of a voltage-source-inverter-driven electric drive is primarily governed by the volumetric contributions of the power modules, heat sinks, and DC-link capacitors. Accordingly, this work focuses on the optimization of these three critical components to enhance the inverter's overall power density. The proposed design achieves a power density of 100 kW/L, demonstrating the effectiveness of the presented approach for next-generation integrated electric drive systems.

33 ADVANCED PROPULSION SYSTEMS↗

CCM vs. CRM Design Optimization of a Boost-derived Parallel Active Power Decoupler for Microinverter Applications

Single-phase inverter or rectifier systems often make use of an auxiliary active power decoupler (APD) to balance the mismatch between steady DC power and fluctuating AC power. This paper deals with efficiency and size optimization of a parallel boost-type APD circuit for PV microinverter applications. Specifically, design of an eGaNFET-based, 400 W APD circuit, employing planar inductor and operating in either continuous conduction mode (CCM) or critical conduction mode (CRM) is considered. Available design variables including inductance value, inductor core geometry, capacitor voltage, switching frequency, and modulation scheme (CCM vs. CRM) are explored to identify Pareto-optimal configurations, which can achieve low California Energy Commission (CEC) efficiency drop while also reducing the footprint area of the inductor. The theoretical study predicts that the optimal CRM design can achieve 37% reduced inductor size, while operating with similar efficiency drop, compared to the optimal CCM design. Experimental results, obtained using two separate 40 V, 400 W hardware prototypes for CCM and CRM, are presented to verify the analyses.

14 SOLAR ENERGY↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimized Highly Efficient SSCB Using Organic Substrate Packaging for Electric Vehicle Applications

Solid State Circuit Breakers (SSCBs) are an attractive protection solution for their arcless current interruption and fast actuation speeds over mechanical breakers. This paper proposes a Bidirectional SSCB (BSSCB) with a thermally defined and digitally controlled current time profile for fault protection in EV and other low-voltage DC systems. The paper proposes an organic packaging approach utilizing flex circuitry to develop a reliable, cost-effective power module for BSSCBs. The paper studies transient heat transfer in the power modules using finite element analysis (FEA). An RC themal ladder network is extracted to define a fusing curve. To demonstrate and verify the design, a 1kV/50 A SiC MOSFET BSSCB prototype is fabricated and tested, having a power density of 60 W/cm3 and 4x reduction in form factor over presently researched breakers. Also, given are results for 750 V/150 A operation showing interruption in 2.4 μs.

organic power packaging↗

2022 Component Innovation Awardee: Windurance

Combining battery energy storage with distributed wind energy systems can increase production, ability to meet local electricity demands, interconnection capacity, and potential sales of surplus energy back to the grid, while reducing demand charges and the overall levelized cost of energy (LCOE). Energy storage options for distributed wind energy systems can vary widely in terms of power level and energy storage capacity, and their potential benefits depend on factors including wind resource, turbine design, connection requirements, use patterns, utility rates, and regulations. Windurance received a 2022 Competitiveness Improvement Project (CIP) funding award to add battery energy storage capabilities to the company's bidirectional DC converter. The energy storage component will complete a comprehensive portfolio of power conversion and control electronics that can be seamlessly integrated with distributed wind systems. The company received earlier CIP awards to fund prototype design and construction of wind turbine pitch actuators, inverters, and controllers.

CIP↗

Resilient, Rural, and Revolutionary: Salisbury Square's Direct-Current Affordable Microgrid Community: Preprint

The technology to interconnect buildings with a dedicated direct-current (DC) power distribution network is in place today; what is missing is a turnkey approach to designing a DC microgrid - and the business models allowing such systems to be deployed, owned, and operated at scale. To close this gap, the Salisbury Square Development Team, comprising clean-energy experts, has engineered a resilient community DC microgrid for an affordable housing community in Randolph, Vermont. Ten single-family, occupant-owned residences and 12 multifamily rental units will share locally generated and stored solar energy via a DC power distribution bus capable of operating during extended grid outages. With a DC power distribution network in place, each home will be equipped with high-efficiency DC lighting and appliances, operating alongside alternating current (AC) appliances, even during an islanded mode of operation. To obtain a comprehensive understanding of what is possible and achievable, the Team collaborated with the local utility, regulatory agencies, a national laboratory, energy-as-service providers, and vendors. The collaborators evaluated microgrid typologies, business models, and energy modeling, and analyzed electrification and resilience. Further, the Team applied the URBANoptTM (Urban Renewable Building and Neighborhood optimization, NREL 2022) software development kit (SDK) to Salisbury Square's single-family and multifamily buildings to validate workflows and identify needs for advanced capability. This paper addresses the barriers to entry, scalability, and impact on residents and system ownership. It also examines the analysis that informed the design and engineering of the DC microgrid and the opportunities to streamline the process.

DER↗

Operation and Control of a Back to Back Modular Multilevel Converter System for Grid Forming Application with Advanced Grid Support Functionalities

The main focus of this paper is to investigate the possibility of using modular multilevel converter based back-to-back system for grid forming applications. A decentralized hierarchical control architecture with a modified local controller based on nonlinear techniques for grid forming application have been investigated. Grid functionalities based on IEEE 1547-2018 for grid forming converters have been utilized. The local controllers ensure distortion free balanced sinusoidal output voltage on the grid forming side with unbalanced or nonlinear loading condition. The grid following side ensures unity power factor currents under unbalanced grid voltage condition. The dc bus voltage control ensures oscillation free voltage under balanced conditions and control of the average voltage under unbalanced condition. Efficacy of the overall system is verified by modeling the system in MATLAB/Simulink and PLECS domain and the most important case studies are presented.

advanced grid support functionalities↗

Comparative Evaluation of the Single-Phase Shift and Extended-Phase Shift Control for Isolated DC-DC Converter

Abstract: This paper presents a comparative evaluation of the Single-Phase Shift (SPS) and Extended-Phase Shift (EPS) controls for the isolated DC-DC Converter. The analysis is based on the power regulation range, flexibility of operation, current stress on power devices, system efficiency while focusing on the issue of backflow power, control complexity, design and implementation overhead, and stability of the entire system. It is also examined how the backflow influences power circulation and increases current stress. Here, the Dual Active Bridge (DAB) Converter is employed to assess the performance of the control methods. Compared to SPS control, EPS offers a wider power regulation range, greater flexibility, lower current stress, and better system efficiency. However, EPS has increased control complexity, design and implementation overhead, and often requires sophisticated feedback control loops. The comparison is made through mathematical modeling of power transfer, backflow, and current stress. Simulation results validate the comparative analysis presented.

Amir, Aamir [The University of Alabama (UA)]↗

ExaGO v2

ExaGO is a high-performance computing power systems modeling suite providing models for different power flow analyses. It supports forward AC power flow, multiperiod AC and DC optimal power flow analyses, contingency analysis, as well as stochastic optimal power flow analysis. ExaGO can use HiOp and Ipopt optimization engines. It supports Matpower and PSS/E input file formats. ExaGO v2 includes code from ExaGO 1.6.0.

Peles, Slaven [Oak Ridge National Laboratory (ORNL↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Farm-level Interactions Study of a Novel Tri-port Soft-switching Medium-Voltage String Inverter (MVSI) based Large-scale PV-Plus-Storage Farms

A medium-voltage photovoltaic power conversion unit supported by battery based on a novel topology of soft switching solid state transformer is presented in this paper. It can reduce the Levelized Cost of Energy (LCOE) of PVS farm in an extended degree. However, its capability to provide grid-support services, such as frequency response, reactive power support, etc, have not been demonstrated. A series/parallel combination of these modules form a large 20 MVA solar farm. To validate them with reduced computation burden, a small-signal model of MVSI is firstly derived and validated in this paper. The model has been validated to match the full-switch model in both steady-state and dynamic conditions. Next, a farm-level simulation based on the proved small-signal model was implemented to demonstrate grid-support services. Real irradiation date from NREL is used to show the operational capabilities of the system. As a result, the overall farm is simulated based on MATLAB/Simulink domain to check the performance for various cases namely: power transfer from dc-ac side, reactive power support during grid voltage sag and utilization of battery during grid voltage disturbance or partial shading over PV panels.

14 SOLAR ENERGY↗

HEMP Transformer Defense Through Power Electronics

High altitude electromagnetic pulses and geo-magnetic disturbances have the potential to severely impact the electric power grid by damaging large power transformers and causing severe power quality issues. This impact comes as a result of a quasi-static bias induced on transmission lines by geomagnetically induced currents which saturate magnetic components in the electric power system. This paper introduces the concept of utilizing a h-bridge inverter on the neutral of a LPT to inject a DC bias equivalent voltage onto the neutral side of the transformer windings. This biasing floats the transformer windings, eliminating the effect of the DC current and keeping the transformer from saturating. Schematic diagrams will be presented, along with simulation model data using Typhoon and PLECS, and finally test results from a benchtop hardware test.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning-Accelerated ADMM for Distributed DC Optimal Power Flow

We suggest a novel data-driven method to accelerate the convergence of Alternating Direction Method of Multipliers (ADMM) for solving distributed DC optimal power flow (DC-OPF) where lines are shared between independent network partitions. Using previous observations of ADMM trajectories for a given system under varying load, the method trains a recurrent neural network (RNN) to predict the converged values of dual and consensus variables. Given a new realization of system load, a small number of initial ADMM iterations is taken as input to infer the converged values and directly inject them into the iteration. We empirically demonstrate that the online injection of these values into the ADMM iteration accelerates convergence by a significant factor for partitioned 14-, 118-and 2848-bus test systems under differing load scenarios. The proposed method has several advantages: it maintains the security of private decision variables inherent in consensus ADMM; inference is fast and so may be used in online settings; RNN-generated predictions can dramatically improve time to convergence but, by construction, can never result in infeasible ADMM subproblems; it can be easily integrated into existing software implementations. While we focus on the ADMM formulation of distributed DC-OPF in this paper, the ideas presented are naturally extended to other distributed optimization problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating commutation failures in HVDC systems with SFCL deployment

Commutation failures represent a prevalent issue encountered in line-commutated-converter high voltage direct current (LCC-HVDC) systems. As the widespread deployment of HVDC systems continues, the risk associated with commutation failures increases, posing a growing threat to power grids due to their potential to trigger severe consequences, including cascading failures and widespread blackouts. This research paper aims to address the significant issue of commutation failure within direct current (DC) systems through advocating for the use of resistive-type Superconducting Fault Current Limiters (R-SFCLs). To substantiate the efficacy of this proposed strategy, an array of simulations are executed using the PSCAD/EMTDC software. This comprehensive study investigates the performance characteristics of R-SFCLs configured with varying resistance values, scrutinizing their response under diverse fault resistance scenarios and distinct fault initiation times within the LCC-HVDC system. The outcomes of these simulations are that SFCLs confer significant advantages for mitigating commutation failures, surpassing traditional mitigation methods in terms of effectiveness. Consequently, SFCLs emerge as an optimal solution to prevent commutation failures in the HVDC systems.

Commutation failure↗

Modeling and Analysis of a Polyphase Wireless Power Transfer System for EV Charging Applications

Extreme fast charging is an emerging technology targeting to significantly decrease charging times of electric vehicles to 10–20 minutes, similar to an interstate gas refueling practice. High-power wireless power transfer (WPT) systems with polyphase electromagnetic couplers can be an attractive solution for these applications due to the very high surface power density of polyphase coils with reduced ripple current characteristics on both the primary and secondary sides that result in more compact designs with reduced dc bus bar capacitor requirements. In addition, WPT systems offer automated charging process, which can be an enabling technology for connected and automated vehicles, with high-efficiency, convenience, safety, and flexibility. This study presents a matrix representation of a mathematical model for a three-phase WPT system with series-series connected three-phase resonant compensation networks. Nonzero interphase mutual inductances between the same side phase windings are considered for tuning to obtain a circuit model for parametric sensitivity. Simulation and experimental results presented for a 50-kW experimental prototype to demonstrate the operation of the polyphase WPT system.

Zeng, Rong↗

Multiphysics Modeling of Hydrokinetic Turbine Energy Conversion System

Hydrokinetic turbines (HKTs) hold great promise as a renewable energy source, but high maintenance costs and limited energy output hinder their widespread adoption. The lack of comprehensive research on HKT drivetrain designs creates a knowledge gap in enhancing generation efficiency and cost reduction. A model of the HKT system with a focus on electric drivetrains and power converters is required to address this knowledge gap. This paper first introduces a MATLAB-averaged model integrating electrical-mechanical-thermal domains and aging behaviors within multi-time frames. Then a PLECS model, which incorporates maximum power point tracking and dq reference framed control for AC-DC-AC power converters, is enriched by a dynamic thermal model to predict fast transients accurately. These models optimize the design at the component level, resulting in improved integrated system performance. Furthermore, the validation of the models is carried out through hardware experiments for the averaged model and hardware-in-the-loop testing for the dynamic model.

ADVANCED PROPULSION SYSTEMS,HYDRO ENERGY↗