Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Semiconductor Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Thin film cadmium telluride charged particle sensors for large area neutron detectors

Thin film semiconductor neutron detectors are an attractive candidate to replace {sup 3}He neutron detectors, due to the possibility of low cost manufacturing and the potential for large areas. Polycrystalline CdTe is found to be an excellent material for thin film charged particle detectors—an integral component of a thin film neutron detector. The devices presented here are characterized in terms of their response to alpha and gamma radiation. Individual alpha particles are detected with an intrinsic efficiency of >80%, while the devices are largely insensitive to gamma rays, which is desirable so that the detector does not give false positive counts from gamma rays. The capacitance-voltage behavior of the devices is studied and correlated to the response due to alpha radiation. When coupled with a boron-based neutron converting material, the CdTe detectors are capable of detecting thermal neutrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonant third harmonic generation of KrF laser in Ar gas

Investigations of emission of harmonics from argon gas jet irradiated by 700 fs, 5 mJ pulses from a KrF laser are presented. Harmonics conversion was optimized by varying the experimental geometry and the nozzle size. For the collection of the harmonic radiation silicon and solar-blind diamond semiconductor detectors equipped with charge preamplifiers were applied. The possibility of using a single-crystal CVD diamond detector for separate measurement of the 3rd harmonic in the presence of a strong pumping radiation was explored. Our experiments show that the earlier suggested 0.7% conversion efficiency can really be obtained, but only in the case when phase matching is optimized with an elongated gas target length corresponding to the length of coherence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of Materials to Single Ion Events

Response of materials to single radiation events is fundamental to research and many technological applications that involve energetic particles. Ion-solid interactions lead to energy loss of ions, production of electron-hole pairs, and light emission from excitation-induced luminescence. Employing a unique time-of-flight system, material response to single ion irradiation has been utilized to measure electronic energy loss, and to evaluate materials performance for radiation detection. Measurements of electronic energy loss of single ions in a thin ZrO2 foil over a continuous energy range exhibit good agreement with SRIM predictions for He and Be ions. For O and F ions, slight over- and under-estimation of SRIM prediction is evident at energies around 250 (near the stopping maximum) and above 800 keV/nucleon, respectively. For a Si semiconductor detector, its response to single ion irradiation shows that pulse height defect is clear for elements heavier than Si, and nonlinear energy response is significant for all elements at energies below ~ 150 keV/nucleon. For a single crystal CsI:Tl scintillator, the response to H ion events is used to determine relative light yield and absolute energy resolution over a wide energy region, where energy resolution of ~ 5.3% is achieved at 2 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of the underwater collimated spectrometric system for survey of storage ponds of research VVR-2 and or reactors - 15118

Spent nuclear fuel removal activities in the National Research Centre 'Kurchatov Institute' were resumed in 2004. During the last two years, removal was performed of the spent nuclear fuel from the VVR-2 and OR reactor installations, whose storage facilities are located within the Gas Plant complex. The Gas Plant complex is the experimental base of the Institute of Nuclear Reactors, which is part of the 'Kurchatov Institute'. The complex features four storage facilities for spent nuclear fuel, one in a dedicated building for storage of spent nuclear fuel and solid rad-waste and three in the reactor building. They are sub-surface vessels filled with water (the volume of water in each is about 6 m{sup 3}), closed with top shielding slabs. Some spent fuel assemblies and fuel elements stored are resized, deformed, or have defective claddings. In the course of works on removal from ponds of the spent nuclear fuel, its fragments could get to water. The bottoms of ponds storage are covered with a deposit. The bottom of ponds and water are possible to be pollution by fission products. The survey objective was to find uranium-containing materials (elements of irradiated nuclear fuel) at the bottom of the ponds and evaluation of surface activity of fission products. To solve this problem was used the underwater collimated spectrometric system on the basis of a semiconductor detector CdZnTe (volume of a crystal of 20 mm{sup 3}) and a multichannel analyzer InSpector 2000. The detector with the collimator is placed in the waterproof case on which the video camera fastens. The principle of detection of uranium-containing materials is based on the identification of the characteristic peaks in the spectra of uranium radiation measurements in the energy range 95 - 115 keV. The results of the most representative measurements at the bottom of reactor ponds are given. The received results are discussed; comparison of results between in-site pond measurements and gamma spectrometric and radiochemical analysis of the water in the lab is carried out. The received results will be used for scheduling on pond cleaning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-322: A Comparison of Two Si Detectors for in Vivo Dosimetry

Purpose: To compare two types of semiconductor detectors for in vivo dosimetry by their dependence from various parameters in different conditions. Methods: QED yellow (Sun Nuclear) and EDP (Scanditronix) Si detectors were radiated by a Varian Clinac 2300 ix with 6 and 18 MV energies. 10 cm thickness water equivalent phantom consisted of 30×30 cm{sup 2} squared plates was used for experiments. Dose dependencies for different beam angles (0 – 180°), field size (3–40 cm), dose (50 – 300 MU), and dose rates (50 – 300 MU/min) were obtained and calibrated with Standard Farmer chamber (PTW). Results: Reproducibility, linearity, dose rate, angular dependence, and field size dependence were obtained for QED and EDP. They show no dose-rate dependence in available clinical dose rate range (100–600 MU/min). Both diodes have linear dependence with increasing the dose. Therefore even in case of high radiation therapy (including total body irradiation) it is not necessary to apply an additional correction during in vivo dosimetry. The diodes have different behavior for angular and field size dependencies. QED diode showed that dose value is stable for beam angles from 0 to 60°, for 60–180° correction factor has to be applied for each beam angle during in vivo measurements. For EDP diode dose value is sensitive to beam angle in whole range of angles. Conclusion: The study shows that QED diode is more suitable for in vivo dosimetry due to dose value independence from incident beam angle in the range 0–60°. There is no need in correction factors for increasing of dose and dose rate for both diodes. The next step will be to carry out measurements in non-standard conditions of total body irradiation. After this modeling of these experiments with Monte Carlo simulation for comparison calculated and obtained data is planned.

60 APPLIED LIFE SCIENCES↗

Installation of a fast framing visible camera on KSTAR

Visible camera technologies have made remarkable progress in recent years, and the fast camera has proven itself to be a capable imaging diagnostic in studies of specific fusion plasma issues such as the start-up physics, plasma wall interactions, edge-localized modes, and disruptions. For the purpose of favorable visible imaging, a fast framing camera has recently been installed on the Korea Superconducting Tokamak Advanced Research (KSTAR) device. The camera uses a complementary metal-oxide semiconductor detector with a maximum resolution of 1280x1024 at 1000 frames/s (fps) and a minimum resolution of 1280x16 at 64 kfps. A 2-m-long viewport having a novel optical rail system was installed on a tangential port to view the tokamak interior. The system is fully controlled from the main control room and protected by a shutter from deposits. To verify that the camera electronics are safe from the high magnetic field and its rapid time variation, possible influences are considered theoretically and experimentally. In this work, we present the design and installation of the fast camera system on the KSTAR device with discussions on the field variation effect issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton emission from thin hydrogenated targets irradiated by laser pulses at 10{sup 16} W/cm{sup 2}

The iodine laser at PALS Laboratory in Prague, operating at 1315 nm fundamental harmonics and at 300 ps FWHM pulse length, is employed to irradiate thin hydrogenated targets placed in vacuum at intensities on the order of 10{sup 16} W/cm{sup 2}. The laser-generated plasma is investigated in terms of proton and ion emission in the forward and backward directions. The time-of-flight technique, using ion collectors and semiconductor detectors, is used to measure the ion currents and the corresponding velocities and energies. Thomson parabola spectrometer is employed to separate the contribution of the ion emission from single laser shots. A particular attention is given to the proton production in terms of the maximum energy, emission yield, and angular distribution as a function of the laser energy, focal position, target thickness, and composition. Metallic and polymeric targets allow to generate protons with large energy range and different yield, depending on the laser, target composition, and target geometry properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Study of an Easily Controlled Ultra-High-Resolution Pixel-Matched Parallel-Hole Collimator with a Small Cadmium Zinc Telluride Pixelated Gamma Camera System

The aim of this study was to develop an easily controlled, ultra-high-resolution, tungsten parallel-hole collimator based on a small pixelated gamma camera system. A small cadmium zinc telluride (CZT) pixelated semiconductor detector (eValuator-2500 detector [eV product, Saxonburg, PA]) was evaluated. This detector is composed of an array of 51.2 × 0.8 × 3-mm{sup 3} individual CZT crystal elements. The ultra-high-resolution, pixel-matched, parallel-hole collimators consisted of six layers, with the same between the hole and pixel size. The basic characteristics of the imaging system, such as sensitivity and spatial resolution, was measured using a {sup 57}Co point source. The measured averages of sensitivity and spatial resolution varied depending on the septal heights of the ultra-high-resolution parallel-hole collimator and source-to-collimator distances. When the 30-mm septal height was at 1-cm source-to-collimator distance, the spatial resolution was approximately 0.85 mm. Using 5-mm septal height, over 0.3 cps/kBq sensitivity was achieved. One advantage of our system is the use of stacked collimators that can select the best combination of system sensitivity and spatial resolution. Our results demonstrated that the developed CZT–pixelated gamma camera system using an ultra-high-resolution parallel-hole collimator of various collimator geometric designs has potential as an effective instrument.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation detector

Technologies are described for semiconductor radiation detectors. The semiconductor radiation detectors may comprise a semiconductor material. The semiconductor material may include a first surface and a second surface. The first surface may be opposite from the second surface. The semiconductor material may include at least one metal component. The semiconductor material may be effective to absorb radiation and induce a current pulse in response thereto. The semiconductor radiation detector may comprise an electrode contact. The electrode contact may include a metal doped oxide deposited on the first surface of the semiconductor material. The metal doped oxide may include the metal component element of the semiconductor material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CdZnTeSe: Recent advances for radiation detector applications

The quest for cost-effective, high performing room temperature semiconductor detector (RTSD) materials for high energy gamma rays has been continuing for more than three decades. The requirements for RTSD materials, however, are more stringent as compared to other applications unrelated to detection of X- and gamma-rays, mainly due to the requirement of thick detectors for sufficient absorption of high-energy electromagnetic radiation and excellent charge-transport properties. The II-VI compound CdZnTe (CZT) with the composition of 10 atomic % Zn (Cd0.9Zn0.1Te) has been the material of choice over the past several years, and it has dominated the commercial market for RTSD materials and detectors. Despite its commercial success as a room temperature radiation detection material, CZT suffers from a lack of compositional homogeneity on both a micro- and macro-scale and the presence of high concentrations of sub-grain boundary (dislocation walls) networks and secondary phases (Te-rich inclusions). This chapter focuses on the presence of performance-limiting defects in CZT that hinder the yield and elevate the cost of high-quality detectors. The presence of such performance-limiting defects has restricted widespread deployment of CZT for a variety of potential applications, particularly for uses of relatively large detectors where the demands on material perfection are significantly greater. In the recent past, replacing some of the tellurium with selenium in the CZT matrix was found to be very effective in drastically reducing the Te-rich secondary phases and dislocation networks, plus

Roy, Utpal N.↗

Response function and optimum configuration of semiconductor backscattered-electron detectors for scanning electron microscopes

A new highly efficient design for semiconductor detectors of intermediate-energy electrons (1-50 keV) for application in scanning electron microscopes is proposed. Calculations of the response function of advanced detectors and control experiments show that the efficiency of the developed devices increases on average twofold, which is a significant positive factor in the operation of modern electron microscopes in the mode of low currents and at low primary electron energies.

36 MATERIALS SCIENCE↗

X-ray photoemission analysis of chemically treated GaTe semiconductor surfaces for radiation detector applications

The surface of the layered III-VI chalcogenide semiconductor GaTe was subjected to various chemical treatments commonly used in device fabrication to determine the effect of the resulting microscopic surface composition on transport properties. Various mixtures of H{sub 3}PO{sub 4}:H{sub 2}O{sub 2}:H{sub 2}O were accessed and the treated surfaces were allowed to oxidize in air at ambient temperature. High-resolution core-level photoemission measurements were used to evaluate the subsequent chemistry of the chemically treated surfaces. Metal electrodes were created on laminar (cleaved) and nonlaminar (cut and polished) GaTe surfaces followed by chemical surface treatment and the current versus voltage characteristics were measured. The measurements were correlated to understand the effect of surface chemistry on the electronic structure at these surfaces with the goal of minimizing the surface leakage currents for radiation detector devices.

36 MATERIALS SCIENCE↗

Modifications developed to improve x-ray detection devices

Improvements in the development of x-ray detection devices are described. Emphasis is placed on lowering the temperature in order to achieve better x-ray response. A simplified charge integrator schematic is presented along with supporting tables. By using cryogenic operating temperatures, these x-ray detectors may eventually surpass the performance of the best semiconductor detectors.

Source record↗

CUORE opens the door to tonne-scale cryogenics experiments

The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution – comparable to semiconductor detectors – and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. In this work, a brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗

Methane Gas Sensing Technologies in Combustion: Comprehensive Review

Major methane (CH 4 ) gas sensing technologies for the application in a combustion environment are reviewed with many theoretical and practical aspects, as well as basic installation and operation details. A comprehensive CH 4 gas sensing technologies review is supported with the latest development trends. Performance and application options for methane measurements in the process using calorimetric, mixed potential electrochemical CH 4 sensor, semiconductor detector and tunable diode (TD) laser and quantum cascade (QC) laser spectroscopy are discussed for the possible application in power generation, chemical production, heating, process control, safety, and quality. Special attention is given to the technology application limits and analyzer’s system requirements.

47 OTHER INSTRUMENTATION↗

TH-CD-201-02: A Monte Carlo Investigation of a Novel Detector Arrangement for the Energy Spectrum Measurement of a 6MV Linear Accelerator

Purpose: Direct measurement of the energy spectrum of a 6MV linear accelerator has not been successful due to the high fluence rate, high energy nature of these photon beams. Previous work used a Compton Scattering (CS) spectrometry setup with a shielded spectrometer for spectrum measurements. Despite substantial lead shielding, excessive pulse pile-up was seen. MCNP6 transport code was used to investigate the feasibility and effectiveness of performing measurements using a novel detector setup. Methods: Simulations were performed with a shielded high-purity germanium (HPGe) semiconductor detector placed in the accelerator vault’s maze, with a 2 cm diameter collimator through a 92 cm thick concrete wall. The detector was positioned 660 cm from a scattering rod (placed at isocenter) at an angle of 45° relative to the central axis. This setup was compared with the shielded detector positioned in the room, 200 cm from the scattering rod at the same CS angle. Simulations were used to determine fluence contributions from three sources: (1) CS photons traveling through the collimator aperture, the intended signal, (2) CS scatter photons penetrating the detector shield, and (3) room-scattered photons penetrating the detector shield. Variance reduction techniques including weight windows, DXTRAN spheres, forced collisions, and energy cutoffs were used. Results: Simulations showed that the number of pulses per starting particle from an F8 detector tally for the intended signal decreased by a factor of 10{sup 2} when moving the detector out of the vault. This reduction in signal was amplified for the unwanted scatter signal which decreased by up to a factor of 10{sup 9}. Conclusion: This work used MCNP6 to show that using a vault wall to shield unwanted scatter and increasing isocenter-to-detector distance reduces unwanted fluence to the detector. This study aimed to provide motivation for future experimental work using the proposed setup.

07 ISOTOPE AND RADIATION SOURCES↗

Fabrication of Low-Cost Large-Volume Ceramic A 2 HfX 6 (A= Cs or Tl, X = Cl, Br, or I) Scintillators for Gamma Ray Detection (SBIR Phase I Final Technical Report)

Scintillator crystals play an important role in the radiation detection field. Widespread use of scintillators as gamma-ray detectors is largely generated by their extensive availability and tunable properties, such high light output, high stopping power (Z eff ), fast decay time, and good proportionality. Additionally, the cost for manufacturing a scintillation detector like NaI:Tl is usually considerably lower than the cost for manufacturing a semiconductor detector like CdZnTe. Because there is no such thing as an ideal scintillation material, an application requiring certain detection characteristics may incorporate a scintillator tailored to its specific properties. The vast variety of applications and requirements necessitates more research into new scintillation materials and/or better methods of producing existing materials.The goal of this project was to grow low cost and environmentally stable inorganic transparent ceramic scintillators with excellent gamma ray resolution, excellent energy proportionality, excellent detection efficiency due to high density (>5 g/cm 3 ) and very high Z eff (55-80), and good light yields (>40,000 ph/MeV). In Phase I Xtallized Intelligence, Inc. (XI, Inc) developed a novel ceramic fabrication technique to produce low cost and environmentally stable highly efficient inorganic transparent ceramic scintillators of various dimensions. XI, Inc., collaborating with Fisk University (Fisk), investigated the scintillation properties of these new ceramic scintillators and compared them to in their single crystal counterparts. The results of this Phase I project show that successful production of high-quality inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Both ceramic CHC and THC scintillators have achieved good performance close to the performance of their single crystal counterparts. Fabricating these inorganic ceramic scintillators mitigate many issues encountered during conventional bulk crystal growth by melt methods. Additional benefits of the ceramic fabrication technique include high production yield, low production cost, fast production time, and no material waste Inorganic transparent ceramic scintillators produced in this project will enhance cost effectiveness at the instrument level based on low projected cost of the proposed compounds, as much smaller crystal sizes would be required to achieve similar efficiency as current radioisotope identification devices (RIID’s) used in homeland security applications as well as spectrometers in high energy physics applications.

36 MATERIALS SCIENCE↗