Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Error response test system and method using test mask variable

An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

Gender, Thomas K.↗

Investigating Response from Attached and Separated Flow Excitations on a Real Launch Vehicle using SEA

Statistical Energy Analysis (SEA) response has been fairly well anchored to test observations for Diffuse Acoustic Field (DAF) loading by others. Meanwhile, not many examples can be found in the literature anchoring the SEA vehicle panel response results to Turbulent Boundary Layer (TBL) fluctuating pressure excitations. This deficiency is especially true for supersonic trajectories such as those required by this nation s launch vehicles. Response and excitation data from vehicle flight measurements gathered during the development flight era of the Space Shuttle have been used in a trial to assess the sensitivity of response analysis to certain known and unknown parameters of the flight. This assessment compares vibration response predictions for TBL excitations produced by the SEA tool to flight measurements. A secondary, but perhaps more important objective, is to provide more clarity concerning the accuracy and conservatism that can be expected from response estimates to TBL-excited vehicle models in SEA. What range of parameters must be included in such an analysis in order to land on the conservative side in response predictions? What is the variability produced in the results with changes in these parameters? The TBL fluid structure loading model used for this study is provided from the SEA module of the commercial code VA One.

Harrison, Phil↗

Exploring Modeling Options and Conversion of Average Response to Appropriate Vibration Envelopes for a Typical Cylindrical Vehicle Panel with Rib-stiffened Design

Although applications for Statistical Energy Analysis (SEA) techniques are more widely used in the aerospace industry today, opportunities to anchor the response predictions using measured data from a flight-like launch vehicle structure are still quite valuable. Response and excitation data from a ground acoustic test at the Marshall Space Flight Center permitted the authors to compare and evaluate several modeling techniques available in the SEA module of the commercial code VA One. This paper provides an example of vibration response estimates developed using different modeling approaches to both approximate and bound the response of a flight-like vehicle panel. Since both vibration response and acoustic levels near the panel were available from the ground test, the evaluation provided an opportunity to learn how well the different modeling options can match band-averaged spectra developed from the test data. Additional work was performed to understand the spatial averaging of the measurements across the panel from measured data. Finally an evaluation/comparison of two conversion approaches from the statistical average response results that are output from an SEA analysis to a more useful envelope of response spectra appropriate to specify design and test vibration levels for a new vehicle.

Harrison, Phil↗

Magnetic-Field-Response Measurement-Acquisition System

A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a response inflection. The "transmit-receive-compare" of sequential harmonics is repeated until the inflection is identified. The harmonic producing the amplitude inflection is the sensor resonant frequency. Resonant frequency and response amplitude are stored and then correlated to calibration data.

Woodward, Stanley E.↗

Improved Lunar Lander Handling Qualities Through Control Response Type and Display Enhancements

A piloted simulation that studied the handling qualities for a precision lunar landing task from final approach to touchdown is presented. A vehicle model based on NASA's Altair Lunar Lander was used to explore the design space around the nominal vehicle configuration to determine which combination of factors provides satisfactory pilot-vehicle performance and workload; details of the control and propulsion systems not available for that vehicle were derived from Apollo Lunar Module data. The experiment was conducted on a large motion base simulator. Eight Space Shuttle and Apollo pilot astronauts and three NASA test pilots served as evaluation pilots, providing Cooper-Harper ratings, Task Load Index ratings and qualitative comments. Each pilot flew seven combinations of control response types and three sets of displays, including two varieties of guidance and a nonguided approach. The response types included Rate Command with Attitude Hold, which was used in the original Apollo Moon landings, a Velocity Increment Command response type designed for up-and-away flight, three response types designed specifically for the vertical descent portion of the trajectory, and combinations of these. It was found that Velocity Increment Command significantly improved handling qualities when compared with the baseline Apollo design, receiving predominantly Level 1 ratings. This response type could be flown with or without explicit guidance cues, something that was very difficult with the baseline design, and resulted in approximately equivalent touchdown accuracies and propellant burn as the baseline response type. The response types designed to be used exclusively in the vertical descent portion of the trajectory did not improve handling qualities.

Mueller, Eric Richard↗

Methods of Using a Magnetic Field Response Sensor Within Closed, Electrically Conductive Containers

Magnetic field response sensors are a class of sensors that are powered via oscillating magnetic fields, and when electrically active, respond with their own magnetic fields with attributes dependent upon the magnitude of the physical quantity being measured. A magnetic field response recorder powers and interrogates the magnetic sensors [see Magnetic-Field-Response Measurement- Acquisition System, NASA Tech Briefs Vol. 30, No, 6 (June 2006, page 28)]. Electrically conductive containers have low transmissivity for radio frequency (RF) energy and thus present problems for magnetic field response sensors. It is necessary in some applications to have a magnetic field response sensor s capacitor placed in these containers. Proximity to conductive surfaces alters the inductance and capacitance of the sensors. As the sensor gets closer to a conductive surface, the electric field and magnetic field energy of the sensor is reduced due to eddy currents being induced in the conductive surface. Therefore, the capacitors and inductors cannot be affixed to a conductive surface or embedded in a conductive material. It is necessary to have a fixed separation away from the conductive material. The minimum distance for separation is determined by the desired sensor response signal to noise ratio. Although the inductance is less than what it would be if it were not in proximity to the conductive surface, the inductance is fixed. As long as the inductance is fixed, all variations of the magnetic field response are due to capacitance changes. Numerous variations of inductor mounting can be utilized, such as providing a housing that provides separation from the conductive material as well as protection from impact damage. The sensor can be on the same flexible substrate with a narrow throat portion of the sensor between the inductor and the capacitor, Figure 1. The throat is of sufficient length to allow the capacitor to be appropriately placed within the container and the inductor placed outside the container. The throat is fed through the orifice in the container wall (e.g., fuel tank opening) and connects to the inductor and capacitor via electrical leads to form a closed circuit, Figure 2. Another embodiment is to have the inductor and capacitor fabricated as separate units. In this embodiment, the inductor is mounted external to the container, and the capacitor is mounted internal to the container, Figure 1. Electrical leads are fed through the orifice to connect the inductor and capacitor, Figure 2. When a container holding multiple sensors is made of a conductive material, an antenna can be placed internal to the container. An internal antenna allows all components of the sensors to reside inside the container. The antenna must be separated from the container wall s conductive surface. Additionally, the inductors must be maintained in a fixed position relative to and separated from the container

Woodward, Stanley E.↗

Calculation of Coupled Vibroacoustics Response Estimates from a Library of Available Uncoupled Transfer Function Sets

The design and theoretical basis of a new database tool that quickly generates vibroacoustic response estimates using a library of transfer functions (TFs) is discussed. During the early stages of a launch vehicle development program, these response estimates can be used to provide vibration environment specification to hardware vendors. The tool accesses TFs from a database, combines the TFs, and multiplies these by input excitations to estimate vibration responses. The database is populated with two sets of uncoupled TFs; the first set representing vibration response of a bare panel, designated as H(sup s), and the second set representing the response of the free-free component equipment by itself, designated as H(sup c). For a particular configuration undergoing analysis, the appropriate H(sup s) and H(sup c) are selected and coupled to generate an integrated TF, designated as H(sup s +c). This integrated TF is then used with the appropriate input excitations to estimate vibration responses. This simple yet powerful tool enables a user to estimate vibration responses without directly using finite element models, so long as suitable H(sup s) and H(sup c) sets are defined in the database libraries. The paper discusses the preparation of the database tool and provides the assumptions and methodologies necessary to combine H(sup s) and H(sup c) sets into an integrated H(sup s + c). An experimental validation of the approach is also presented.

Smith, Andrew↗

Decadal-Scale Responses in Middle and Upper Stratospheric Ozone From SAGE II Version 7 Data

Stratospheric Aerosol and Gas Experiment (SAGE II) version 7 (v7) ozone profiles are analyzed for their decadal-scale responses in the middle and upper stratosphere for 1991 and 1992-2005 and compared with those from its previous version 6.2 (v6.2). Multiple linear regression (MLR) analysis is applied to time series of its ozone number density vs. altitude data for a range of latitudes and altitudes. The MLR models that are fit to the time series data include a periodic 11 yr term, and it is in-phase with that of the 11 yr, solar UV (Ultraviolet)-flux throughout most of the latitude/ altitude domain of the middle and upper stratosphere. Several regions that have a response that is not quite in-phase are interpreted as being affected by decadal-scale, dynamical forcings. The maximum minus minimum, solar cycle (SClike) responses for the ozone at the low latitudes are similar from the two SAGE II data versions and vary from about 5 to 2.5% from 35 to 50 km, although they are resolved better with v7. SAGE II v7 ozone is also analyzed for 1984-1998, in order to mitigate effects of end-point anomalies that bias its ozone in 1991 and the analyzed results for 1991-2005 or following the Pinatubo eruption. Its SC-like ozone response in the upper stratosphere is of the order of 4%for 1984-1998 vs. 2.5 to 3%for 1991-2005. The SAGE II v7 results are also recompared with the responses in ozone from the Halogen Occultation Experiment (HALOE) that are in terms of mixing ratio vs. pressure for 1991-2005 and then for late 1992- 2005 to avoid any effects following Pinatubo. Shapes of their respective response profiles agree very well for 1992-2005. The associated linear trends of the ozone are not as negative in 1992-2005 as in 1984-1998, in accord with a leveling off of the effects of reactive chlorine on ozone. It is concluded that the SAGE II v7 ozone yields SC-like ozone responses and trends that are of better quality than those from v6.2.

Remsberg, E. E.↗

Tropospheric Column Ozone Response to ENSO in GEOS-5 Assimilation of OMI and MLS Ozone Data

We use GEOS-5 analyses of Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS) ozone observations to investigate the magnitude and spatial distribution of the El Nino Southern Oscillation (ENSO) influence on tropospheric column ozone (TCO) into the middle latitudes. This study provides the first explicit spatially resolved characterization of the ENSO influence and demonstrates coherent patterns and teleconnections impacting the TCO in the extratropics. The response is evaluated and characterized by both the variance explained and sensitivity of TCO to the Nino 3.4 index. The tropospheric response in the tropics agrees well with previous studies and verifies the analyses. A two-lobed response symmetric about the Equator in the western Pacific/Indonesian region seen in some prior studies and not in others is confirmed here. This two-lobed response is consistent with the large-scale vertical transport. We also find that the large-scale transport in the tropics dominates the response compared to the small-scale convective transport. The ozone response is weaker in the middle latitudes, but a significant explained variance of the TCO is found over several small regions, including the central United States. However, the sensitivity of TCO to the Nino 3.4 index is statistically significant over a large area of the middle latitudes. The sensitivity maxima and minima coincide with anomalous anti-cyclonic and cyclonic circulations where the associated vertical transport is consistent with the sign of the sensitivity. Also, ENSO related changes to the mean tropopause height can contribute significantly to the midlatitude response. Comparisons to a 22-year chemical transport model simulation demonstrate that these results from the 9- year assimilation are representative of the longer term. This investigation brings insight to several seemingly disparate prior studies of the El Nino influence on tropospheric ozone in the middle latitudes.

ML↗

Systemic Microgravity Response: Utilizing GeneLab to Develop Hypotheses for Spaceflight Risks

Biological risks associated with microgravity is a major concern for space travel. Although determination of risk has been a focus for NASA research, data examining systemic (i.e., multi- or pan-tissue) responses to space flight are sparse. The overall goal of our work is to identify potential master regulators responsible for such responses to microgravity conditions. To do this we utilized the NASA GeneLab database which contains a wide array of omics experiments, including data from: 1) different flight conditions (space shuttle (STS) missions vs. International Space Station (ISS); 2) different tissues; and 3) different types of assays that measure epigenetic, transcriptional, and protein expression changes. We have performed meta-analysis identifying potential master regulators involved with systemic responses to microgravity. The analysis used 7 different murine and rat data sets, examining the following tissues: liver, kidney, adrenal gland, thymus, mammary gland, skin, and skeletal muscle (soleus, extensor digitorum longus, tibialis anterior, quadriceps, and gastrocnemius). Using a systems biology approach, we were able to determine that p53 and immune related pathways appear central to pan-tissue microgravity responses. Evidence for a universal response in the form of consistency of change across tissues in regulatory pathways was observed in both STS and ISS experiments with varying durations; while degree of change in expression of these master regulators varied across species and strain, some change in these master regulators was universally observed. Interestingly, certain skeletal muscle (gastrocnemius and soleus) show an overall down-regulation in these genes, while in other types (extensor digitorum longus, tibialis anterior and quadriceps) they are up-regulated, suggesting certain muscle tissues may be compensating for atrophy responses caused by microgravity. Studying these organtissue-specific perturbations in molecular signaling networks, we demonstrate the value of GeneLab in characterizing potential master regulators associated with biological risks for spaceflight.

Microgravity↗

Connecting Regional Aerosol Emissions Reductions to Local and Remote Precipitation Responses

The unintended climatic implications of aerosol and precursor emission reductions implemented to protect public health are poorly understood. We investigate the precipitation response to regional changes in aerosol emissions using three coupled chemistry-climate models: NOAA Geophysical Fluid Dynamics Laboratory Coupled Model 3 (GFDL-CM3), NCAR Community Earth System Model (CESM1), and NASA Goddard Institute for Space Studies ModelE2 (GISS-E2). Our approach contrasts a long present-day control simulation from each model (up to 400 years with perpetual year 2000 or 2005 emissions) with 14 individual aerosol emissions perturbation simulations (160-240 years each). We perturb emissions of sulfur dioxide and/or carbonaceous aerosol within six world regions and assess the significance of precipitation responses relative to internal variability determined by the control simulation and across the models. Global and regional precipitation mostly increases when we reduce regional aerosol emissions in the models, with the strongest responses occurring for sulfur dioxide emissions reductions from Europe and the United States. Precipitation responses to aerosol emissions reductions are largest in the tropics and project onto the El Nino Southern Oscillation (ENSO). Regressing precipitation onto an Indo-Pacific zonal sea level pressure gradient index (a proxy for ENSO) indicates that the ENSO component of the precipitation response to regional aerosol removal can be as large as 20% of the total simulated response. Precipitation increases in the Sahel in response to aerosol reductions in remote regions because an anomalous interhemispheric temperature gradient alters the position of the Intertropical Convergence Zone (ITCZ). This mechanism holds across multiple aerosol reduction simulations and models.

Westervelt, Daniel M.↗

The Response of the Ozone Layer Under Abrupt 4xCO2 in CMIP6

Previous studies indicate a possible role of stratospheric ozone chemistry feedbacks in the climate response to 4xCO2, either via a reduction in equilibrium climate sensitivity (ECS) (Nowack et al., 2015), or via changes in the tropospheric circulation (Chiodo and Polvani, 2017). However, these effects are subject to uncertainty. Part of the uncertainty may stem from the dependency of the feedback on the pattern of the ozone response, as the radiative efficiency of ozone largely depends on its vertical distribution (Lacis et al., 1990). Here, an analysis is presented of the ozone layer response to 4xCO2 in chemistry–climate models (CCMs) which participated to CMIP intercomparisons. In a previous study using CMIP5 models, it has been shown that under 4xCO2, ozone decreases in the tropical lower stratosphere, and increases over the high latitudes and throughout the upper stratosphere. It was also found that a substantial portion of the spread in the tropical column ozone is tied to inter-model spread in tropical upwelling, which is in turn partly tied to ECS (Chiodo et al., 2018). Here, we revisit this connection using4xCO2 data from CMIP6, thereby exploiting the larger number of CCMs than in CMIP5. In addition, we explore the linearity of the ozone response, by complementing the analysis with simulations using transient CO2 forcing (1pc/year). We show that the pattern of the ozone response in is similar to CMIP5. In some models (e.g. WACCM), we find larger ozone responses in CMIP6 than in CMIP5, partly because of the larger ECS and thus larger upwelling response in the tropical pipe. In this presentation, we will discuss the relationship between radiative forcing, transport and ozone, as well as further implications for CMIP6 models.

Ozone layer↗

The Response of the Ozone Layer Under Abrupt 4xCO2 in CMIP6

Previous studies indicate a possible role of stratospheric ozone chemistry feedbacks in the climate response to 4xCO2, either via a reduction in equilibrium climate sensitivity (ECS) (Nowack et al.,2015), or via changes in the tropospheric circulation (Chiodo and Polvani, 2017). However, these effects are subject to uncertainty. Part of the uncertainty may stem from the dependency of the feedback on the pattern of the ozone response, as the radiative efficiency of ozone largely depends on its vertical distribution (Lacis et al., 1990). Here, an analysis is presented of the ozone layer response to 4xCO2 in chemistry–climate models (CCMs) which participated to CMIP intercomparisons. In a previous study using CMIP5 models, it has been shown that under 4xCO2, ozone decreases in the tropical lower stratosphere, and increases over the high latitudes and throughout the upper stratosphere. It was also found that a substantial portion of the spread in the tropical column ozone is tied to inter-model spread in tropical upwelling, which is in turn tied to ECS (Chiodo et al., 2018). Here, we revisit this connection using 4xCO2 data from CMIP6, thereby exploiting the larger number of CCMs than in CMIP5. In addition, we explore the linearity of the ozone response, by complementing the analysis with simulations using lower CO 2 forcing levels (2xCO2). We show that the pattern of the ozone response in is similar to CMIP5. In some models (e.g. WACCM), we find larger ozone responses in CMIP6 than in CMIP5, partly because of the larger ECS and thus larger upwelling response in the tropical pipe. In this presentation, we will discuss the relationship between radiative forcing, transport and ozone, as well as further implications for CMIP6 models.

Ozone layer↗

Impact of Cyber Threat Awareness on Driver Response to an Unexpected Vehicle Cyberattack

Here, the integration of advanced cyber-physical systems in heavy vehicles introduces new vulnerabilities by expanding the possibility of cyberattacks. The objective of this study is to evaluate (1) how threat awareness influences driver response to an unexpected cyberattack, (2) how the provision of a basic cyberattack response protocol influences driver performance, and (3) how professionally trained versus standard drivers compare in their responses to a cyberattack. An on-road driving study (N = 50) was conducted using a medium heavy-duty vehicle. Participants were divided into three groups: Control, which remained unaware of any potential cyberattack; Aware, which was informed about the potential cyberattack; and Aware + Protocol, which received the same warning as the Aware group with the addition of a basic cyberattack response protocol. An instrument cluster cyberattack was executed at the same location for all participants. The findings highlight the essential role of awareness and response protocol in enhancing driver response to an unexpected vehicle cyberattack. The Aware + Protocol group had the highest stop rate (100%) and the shortest stopping distances (224 m for standard drivers and 254 m for professionals), compared to the Control group (828 and 520 m, respectively). Aware + Protocol also had the fastest reaction time, averaging 7.53 s, versus 16.12 s (Aware) and 30.29 s (Control). These results emphasize that awareness alone is insufficient. Providing drivers with clear, actionable protocols significantly improves their ability to react quickly and safely to cyberattacks, enhancing overall road safety.

Cybersecurity↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗

Effects of equilibrium pressure on plasma response to RMPs in a spherical tokamak

This study presents a comprehensive analysis of the equilibrium pressure on the plasma response to resonant magnetic perturbations (RMPs) in the spherical tokamak (ST) MAST-U, employing both single-fluid and MHD-kinetic hybrid models (implemented via the MARS-F/K codes). As a key finding, the study identifies two different pressure-driven eigenmodes, exhibiting Sturmian property, that affect the Troyon no-wall limits for the onset of the n = 1 and n = 2 ( n is the toroidal mode number) ideal external kink instabilities as well as the corresponding plasma response to the applied RMP. With increasing equilibrium pressure, the plasma response to RMPs is significantly enhanced in the ST plasma, particularly in the high-pressure regime where kinetic effects strongly stabilize the external kink instability. The Troyon no-wall limit divides the plasma response into two regions: well below the limit, the response amplitudes and trends (versus pressure) are similar between the fluid and kinetic models; as the equilibrium pressure approaches the Troyon limit, the kinetic model predicts significant amplification of the RMP field, up to 30 times for cases considered. A relatively weak dependence of the optimal coil phasing on the equilibrium pressure is computed in this ST plasma, similar to the trend obtained for the conventional aspect ratio devices. These findings underscore the importance of incorporating kinetic effects in accurate prediction of the plasma response to RMPs in high-pressure ST tokamak plasmas and provide a theoretical basis for optimizing RMP-based control of the edge-localized modes in future ST devices.

RMP↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Heterogeneous responses of human limbs to infused adrenergic agonists: a gravitational effect?

Unlike quadrupeds, the legs of humans are regularly exposed to elevated pressures relative to the arms. We hypothesized that this "dependent hypertension" would be associated with altered adrenergic responsiveness. Isoproterenol (0.75-24 ng x 100 ml limb volume-1 x min-1) and phenylephrine (0.025-0.8 microg x 100 ml limb volume-1 x min-1) were infused incrementally in the brachial and femoral arteries of 12 normal volunteers; changes in limb blood flow were quantified by using strain-gauge plethysmography. Compared with the forearm, baseline calf vascular resistance was greater (38.8 +/- 2.5 vs. 26.9 +/- 2.0 mmHg x 100 ml x min x ml-1; P < 0.001) and maximal conductance was lower (46.1 +/- 11.9 vs. 59.4 +/- 13.4 ml x ml-1 x min-1 x mmHg-1; P < 0.03). Vascular conductance did not differ between the two limbs during isoproterenol infusions, whereas decreases in vascular conductance were greater in the calf than the forearm during phenylephrine infusions (P < 0.001). With responses normalized to maximal conductance, the half-maximal response for phenylephrine was significantly less for the calf than the forearm (P < 0.001), whereas the half-maximal response for isoproterenol did not differ between limbs. We conclude that alpha1- but not beta-adrenergic-receptor responsiveness in human limbs is nonuniform. The relatively greater response to alpha1-adrenergic-receptor stimulation in the calf may represent an adaptive mechanism that limits blood pooling and capillary filtration in the legs during standing.

Clinical Trial↗