Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A hybrid model for simulation of secondary electron emission in plasma immersion ion implantation under different pulse rise time

A hybrid fluid Particle in Cell–Monte Carlo Collision (PiC–MCC) model is presented to study the effect of secondary electron emission on the plasma immersion ion implantation process under different pulse rise time. The model describes the temporal evolution of various parameters of plasma such as ion density, ion velocity, secondary electron density, and secondary electron current for different rise times. A 3D–3 V PiC–MCC model is developed to simulate the secondary electrons which are emitted from the sample surface while the plasma ions and electrons are treated using a 1D fluid model. The simulation results indicate that the secondary electron density and secondary electron current increase as the rise time decreases. The main differences between the results for different rise times are found during the initial phase of the pulse. The results are explained through studying the fundamental parameters of plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Origins of low resistivity and Ge donor level in Ge ion-implanted ZnO bulk single crystals

The energy level of Ge in Ge-ion implanted ZnO single crystals is studied by Hall-effect and photoluminescence (PL) methods. The variations in resistivity from ∼10{sup 3} Ωcm for un-implanted samples to ∼10{sup −2} Ωcm for as-implanted ones are observed. The resistivity is further decreased to ∼10{sup −3} Ωcm by annealing. The origins of the low resistivity are attributed to both the zinc interstitial (Zn{sub i}) related defects and the electrical activated Ge donor. An activation energy of Ge donors estimated from the temperature dependence of carrier concentration is 102 meV. In PL studies, the new peak at 372 nm (3.33 eV) related to the Ge donor is observed in 1000 °C annealed samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of trap properties in high-k/metal gate p-type metal-oxide-semiconductor field-effect-transistors with aluminum ion implantation using random telegraph noise analysis

In this study, the impact of aluminum ion implantation (Al I/I) on random telegraph noise (RTN) in high-k/metal gate (HK/MG) p-type metal-oxide-semiconductor field-effect-transistors (pMOSFETs) was investigated. The trap parameters of HK/MG pMOSFETs with Al I/I, such as trap energy level, capture time and emission time, activation energies for capture and emission, and trap location in the gate dielectric, were determined. The configuration coordinate diagram was also established. It was observed that the implanted Al could fill defects and form a thin Al{sub 2}O{sub 3} layer and thus increase the tunneling barrier height for holes. It was also observed that the trap position in the Al I/I samples was lower due to the Al I/I-induced dipole at the HfO{sub 2}/SiO{sub 2} interface.

36 MATERIALS SCIENCE↗

Influence of the chemical nature of implanted ions on the structure of a silicon layer damaged by implantation

The influence of the implantation of silicon single crystals by fluorine, nitrogen, oxygen, and neon ions on the distribution of strain and the static Debye-Waller factor in the crystal lattice over the implanted-layer depth has been investigated by high-resolution X-ray diffraction. The density depth distribution in the surface layer of native oxide has been measured by X-ray reflectometry. Room-temperature implantation conditions have ensured the equality of the suggested ranges of ions of different masses and the energies transferred by them to the target. It is convincingly shown that the change in the structural parameters of the radiation-damaged silicon layer and the native oxide layer depend on the chemical activity of the implanted ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrical and optical properties of nitrile rubber modified by ion implantation

Implantation of N{sup +} ion beams are performed on to a non-conjugated elastomer, acrylonirtle butadiene rubber (NBR) with energy 60 keV in the fluence range of 10{sup 14} to 10{sup 16} ions/cm{sup 2}. A decrease in the resistivity of the sample by about eight orders of magnitude is observed in the implanted samples along with color changes. The ion exposed specimens were characterized by means of UV/Vis spectroscopy which shows a shift in the absorption edge value for the as deposited polymer towards higher wavelengths. The band gap is evaluated from the absorption spectra and is found to decrease with increasing fluence. This study can possibly throw light on ion induced changes in the polymer surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion implanted junctions for silicon space solar cells

This paper reviews the application of ion implantation to emitter and back surface field formation in silicon space solar cells. Experiments based on 2 ohm-cm boron-doped silicon are presented. It is shown that the implantation process is particularly compatible with formation of a high-quality back surface reflector. Large area solar cells with AM0 efficiency greater than 14 percent are reported.

Spitzer, M. B.↗

30 GHz monolithic balanced mixers using an ion-implanted FET-compatible 3-inch GaAs wafer process technology

An all ion-implanted Schottky barrier mixer diode which has a cutoff frequency greater than 1000 GHz has been developed. This new device is planar and FET-compatible and employs a projection lithography 3-inch wafer process. A Ka-band monolithic balanced mixer based on this device has been designed, fabricated and tested. A conversion loss of 8 dB has been measured with a LO drive of 10 dBm at 30 GHz.

Bauhahn, P.↗

Oxygen plasma immersion ion implantation treatment to enhance data retention of tungsten nanocrystal nonvolatile memory

Data retention characteristics of tungsten nanocrystal (W-NC) memory devices using an oxygen plasma immersion ion implantation (PIII) treatment are investigated. With an increase of oxygen PIII bias voltage and treatment time, the capacitance–voltage hysteresis memory window is increased but the data retention characteristics become degraded. High-resolution transmission electron microscopy images show that this poor data retention is a result of plasma damage on the tunneling oxide layer, which can be prevented by lowering the bias voltage to 7 kV. In addition, by using the elevated temperature retention measurement technique, the effective charge trapping level of the WO{sub 3} film surrounding the W-NCs can be extracted. This measurement reveals that a higher oxygen PIII bias voltage and treatment time induces more shallow traps within the WO{sub 3} film, degrading the retention behavior of the W-NC memory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical absorption in silicon layers in the presence of charge inversion/accumulation or ion implantation

We determine the optical losses in gate-induced charge accumulation/inversion layers at a Si/SiO{sub 2} interface. Comparison between gate-induced charge layers and ion-implanted thin silicon films having an identical sheet resistance shows that optical losses can be significantly lower for gate-induced layers. For a given sheet resistance, holes produce higher optical loss than electrons. Measurements have been performed at λ = 1550 nm.

36 MATERIALS SCIENCE↗

Investigation of Ion-Implanted Photosensitive Silicon Structures by Electrochemical Capacitance–Voltage Profiling

The method of electrochemical capacitance–voltage profiling is used to study boron-implanted silicon structures for CCD matrices with backside illumination. A series of specially prepared structures with different energies and doses of ion implantation and also with various materials used for the coating layers (aluminum, silicon oxide, and their combinations) is studied. The profiles of the depth distribution of majority charge carriers of the studied structures are obtained experimentally. Also, using the Poisson equation and the Fredholm equation of the first kind, the distributions of the charge-carrier concentration and of the electric field in the structures are calculated. On the basis of the analysis and comparison of theoretical and experimental concentration profiles, recommendations concerning optimization of the structures’ parameters in order to increase the value of the pulling field and decrease the effect of the surface potential on the transport of charge carriers are suggested.

36 MATERIALS SCIENCE↗

MAGNESIUM PRECIPITATION AND DIFUSSION IN Mg+ ION IMPLANTED SILICON CARBIDE

As a candidate material for fusion reactor applications, silicon carbide (SiC) undergoes transmutation reactions under high-energy neutron irradiation with magnesium as the major metallic transmutant; the others include aluminum, beryllium and phosphorus in addition to helium and hydrogen gaseous species. Calculations by Sawan et al. predict that at a dose of ~100 dpa (displacements per atom), there is ~0.5 at.% Mg generated in SiC. The impact of these transmutants on SiC structural stability is currently unknown. This study uses ion implantation to introduce Mg into SiC. Multiaxial ion-channeling analysis of the as-produced damage state indicates a lower dechanneling yield observed along the <100> axis. The microstructure of the annealed sample was examined using high-resolution scanning transmission electron microscopy. The results show a high concentration of likely non-faulted tetrahedral voids and possible stacking fault tetrahedra near the damage peak. In addition to lattice distortion, dislocations and intrinsic and extrinsic stacking faults are also observed. Magnesium in 3C–SiC prefers to substitute for Si and it forms precipitates of cubic Mg2Si and tetragonal MgC2. The diffusion coefficient of Mg in 3C–SiC single crystal at 1573 K has been determined to be 3.8 ± 0.4E-19 m2/s.

diffusion↗

Synthesis and properties of ferromagnetic nanostructures embedded within a high-quality crystalline silicon matrix via ion implantation and nanocavity assisted gettering processes

Integrating magnetic functionalities with silicon holds the promise of developing, in the most dominant semiconductor, a paradigm-shift information technology based on the manipulation and control of electron spin and charge. Here, we demonstrate an ion implantation approach enabling the synthesis of a ferromagnetic layer within a defect free Si environment by exploiting an additional implant of hydrogen in a region deep below the metal implanted layer. Upon post-implantation annealing, nanocavities created within the H-implanted region act as trapping sites for gettering the implanted metal species, resulting in the formation of metal nanoparticles in a Si region of excellent crystal quality. This is exemplified by the synthesis of magnetic nickel nanoparticles in Si implanted with H{sup +} (range: ∼850 nm; dose: 1.5 × 10{sup 16 }cm{sup −2}) and Ni{sup +} (range: ∼60 nm; dose: 2 × 10{sup 15 }cm{sup −2}). Following annealing, the H implanted regions populated with Ni nanoparticles of size (∼10–25 nm) and density (∼10{sup 11}/cm{sup 2}) typical of those achievable via conventional thin film deposition and growth techniques. In particular, a maximum amount of gettered Ni atoms occurs after annealing at 900 °C, yielding strong ferromagnetism persisting even at room temperature, as well as fully recovered crystalline Si environments adjacent to these Ni nanoparticles. Furthermore, Ni nanoparticles capsulated within a high-quality crystalline Si layer exhibit a very high magnetic switching energy barrier of ∼0.86 eV, an increase by about one order of magnitude as compared to their counterparts on a Si surface or in a highly defective Si environment.

36 MATERIALS SCIENCE↗

Nuclear radiation detectors based on a matrix of ion-implanted p-i-n diodes on undoped GaAs epilayers

Samples of nuclear detectors which represent matrices of p-i-n diodes were fabricated based on undoped gallium arsenide epitaxial layers by ion implantation technology. The detectors have a size of the active area of 0.4 Multiplication-Sign 0.4 and 0.9 Multiplication-Sign 0.9 cm{sup 2}. Electrical characteristics of fabricated detectors and results of measurements of fast neutrons spectra of {sup 241}Am-Be source by the recoil protons method are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silver migration and trapping in ion implanted ZnO single crystals

Potentially, group-Ib elements (Cu, Ag, and Au) incorporated on Zn sites can be used for p-type doping of ZnO, and in the present paper, we use ion implantation to introduce Ag atoms in wurtzite ZnO single crystals. Monitoring the Li behavior, being a residual impurity in the crystals, as a tracer, we demonstrate that Zn interstitials assist the Ag diffusion and lead to Ag pile-up behind the implanted region after annealing above 800 °C. At even higher temperatures, a pronounced Ag loss from the sample surface occurs and concurrently the Ag atoms exhibit a trap-limited diffusion into the crystal bulk with an activation energy of ∼2.6 eV. The dominant traps are most likely Zn vacancies and substitutional Li atoms, yielding substitutional Ag atoms. In addition, formation of an anomalous multipeak Ag distribution in the implanted near-surface region after annealing can be attributed to local implantation-induced stoichiometry disturbances leading to trapping of the Ag atoms by O and Zn vacancies in the vicinity of the surface and in the end-of-range region, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A feasibility study of ion implantation techniques for mass spectrometer calibration

An experimental study was undertaken to examine the feasibility of using ion-implanted filaments doped with either an alkali metal or noble gas for in situ recalibration of onboard mass spectrometers during extended space missions. Implants of rubidium and krypton in rhenium ribbon filaments were subsequently tested in a bakeable 60 deg sector mass spectrometer operating in the static mode. Surface ionization and electron impact ion sources were both used, each yielding satisfactory results. The metallic implant with subsequent ionization provided a means of mass scale calibration and determination of system operating parameters, whereas the noble gas thermally desorbed into the system was more suited for partial pressure and sensitivity determinations.

Koslin, M. E.↗