Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS COMPOSITION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution

The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.

Counterfeit refrigerants↗

Projecting the Performance of a Continuous Bosch Carbon Dioxide Reduction System

Kinetic studies using a subscale reactor were used to develop power-law rate equations for the two primary reactions contributing to the Bosch carbon dioxide reduction process: the reverse water-gas shift reaction and the carbon monoxide hydrogenation reaction. An alloy catalyst in bead form was used in these studies, which investigated both the dependence on gas composition and the dependence on time as the beads gradually disintegrate during carbon formation. Bead disintegration impacts both the rates and the relative activities of the two primary reactions. Although the kinetic testing was conducted in a single-pass mode, the target Bosch application requires operation in a recycle mode to achieve high conversion. Further, the proposed design concept for a full-scale carbon dioxide reduction system would allow carbon to be removed continuously in contrast to previous Bosch processes that required replacement of expendable catalyst cartridges. The developed power-law kinetic rate equations were used in conjunction with a reactor model to project the operating conditions, performance, and sizing of a continuous Bosch system.

carbon dioxide reduction↗

Life Cycle Analysis of Natural Gas Extraction and Power Generation: U.S. 2020 Emissions Profile

This analysis expands upon previous life cycle analyses (LCAs) of natural gas systems performed by the National Energy Technology Laboratory (NETL). It provides a complete inventory of emissions to air and water, water consumption, and land use change. These environmental burdens are detailed for all supply chain steps from natural gas production through natural gas distribution. This package includes the report, the NETL Natural Gas Model, and appendices that include several Excel workbooks and a python script to provide transparent access to the calculations and resulting data. This is revision 1 of the 2024 study (published December 17, 2024 and updated on January 24, 2025) and corrects a modeling error in natural gas composition. See the errata on page 2 for more information.

03 NATURAL GAS↗

UT-GOM2-2 Preliminary Report: Terrebonne Basin Northern Gulf of Mexico, 30 July-28 September 2023

In the summer and fall of 2023, the Gulf of Mexico Deepwater Hydrate Coring Expedition (UT-GOM2-2) drilled, cored, made downhole measurements, and analyzed samples from the seafloor to the base of the gas hydrate stability zone in one location (Site H, WR313) in the Terrebonne basin, deepwater Gulf of Mexico. Analyses of data and samples from the expedition will inform biological, geochemical, and geomechanical models to constrain the role of gas hydrates in the carbon cycle and the potential for gas hydrates as an energy resource. Pressure and conventional cores were collected continuously to a depth of 155.1 meters below the seafloor (mbsf). At deeper depths, cores were taken periodically from hydrate-bearing sands and their bounding muds to a total depth of 861.3 mbsf. 162.6 m of conventional core and 54.8 m of pressure core were obtained. Twelve temperature measurements were made between 27.1 and 144.5 mbsf to determine the geothermal gradient. At the seafloor, more than 4 m of sandy silt of unknown origin was encountered. Beneath this sand, to a depth of ~200 mbsf, the section was composed of interbedded mud and biogenic carbonate ooze. The biogenic ooze correlated to low density and high porosity intervals observed in the previously acquired logging while drilling (LWD) data and as measured. Calcareous nannofossil biostratigraphy constrains the entire record to the Pleistocene (< 0.91 million years) with a pronounced increase in sedimentation rate with depth. Beneath 200 mbsf, the section was predominantly composed of mud with two thicker, hydrate-bearing coarse-grained intervals, which are commonly known as the Blue and Orange sands. The dissolved gas concentration was quantified from pressure cores. In the shallow section, dissolved methane concentration increased below the sulfate-methane transition zone (SMTZ) and reaches saturation (the limit of solubility for methane) at 147 mbsf. Gas expansion was very common in conventional and depressurized pressure (conventionalized) cores below the SMTZ. At deeper depths, the methane concentration within muds bounding the Blue and Orange reservoirs was generally found to be less than saturation. The dissolved and hydrate gas composition is consistent with a microbial source, containing greater than 99.99% methane and only trace concentrations of ethane, propane, and butane. The methane to ethane ratio (C 1 /C 2 ) and the methane to ethane plus propane (C 1 /(C 2 +C 3 )) decrease with depth down to at least 678 mbsf, mainly driven by the increase in ethane with depth. It is unclear if this trend continues through the Orange sand interval. The δ 13 C isotopic signature of methane ranges between -69.9 and -78.5 ‰ Vienna Pee Dee Belemnite (VPDB). Pressure core recovery of all sandy intervals was poor. However, pressure core logs of the Orange sand show intervals of low density and high velocity, which are indicative of high hydrate saturation. One core from within the Orange sand was composed of interbedded graded sandy silt and mud. The sandy silts from this core are composed of mainly quartz and feldspar with some lithics. Most of the recovered pressure core samples are maintained at near in-situ pressure and temperature (within the hydrate stability field) at the University of Texas Pressure Core Center awaiting analysis. In the shallow section, samples will be used to determine the flux of organic carbon through the basin system, find the rate at which that carbon was consumed, and understand the microbial population responsible for these processes. In the deeper section, samples from in and around the hydrate reservoirs will be used to determine the petrophysical properties of the reservoir and bounding seals in these systems.

03 NATURAL GAS↗

Expedition UT-GOM2-2 Site H

Pressure and conventional cores were collected at Site H of the Walker Ridge Protracted Area Block 313 in the Terrebonne Basin, deepwater Gulf of America (Gulf of Mexico) during the University of Texas (UT) Deepwater Hydrate Coring Expedition (UT-GOM2-2). Pressure and conventional cores were collected continuously to a depth of 155.1 meters below the seafloor (mbsf). At deeper depths, cores were taken periodically from hydrate-bearing sands and their bounding muds to a total depth of 861.3 mbsf. 162.6 m of conventional core and 54.8 m of pressure core were recovered. Twelve temperature measurements were made between 27.1 and 144.5 mbsf to determine the geothermal gradient. At the seafloor, more than 4 m of sandy silt of unknown origin was encountered. Beneath this sand, to a depth of about 200 mbsf, the section was composed of interbedded mud and biogenic carbonate ooze. The ooze correlated to low density and high porosity intervals observed in the previously acquired logging while drilling (LWD) data and as measured. These ooze intervals also correspond to lighter sediment color, increased Ca content based on X-ray florescence (XRF) core scanning, and increased calcareous nannofossil abundance. Calcareous nannofossil biostratigraphy constrains the entire record to the Pleistocene (< 0.91 million years), with a pronounced increase in sedimentation rate with depth. Below 200 mbsf, the section was predominantly composed of mud with two thicker, hydrate-bearing coarse-grained intervals, which are commonly known as the Blue and Orange sands. The dissolved gas concentration was quantified from pressure cores. In the shallow section, dissolved methane concentration increased below the sulfate-methane transition zone (SMTZ) and reaches saturation (the limit of solubility for methane) at 147 mbsf. Gas expansion was very common in conventional and depressurized pressure (conventionalized) cores below the SMTZ. At deeper depths, the methane concentration within muds bounding the Blue and Orange reservoirs was generally found to be less than saturation. The dissolved and hydrate gas composition is consistent with a microbial source, containing greater than 99.99% methane and only trace concentrations of ethane, propane, and butane. The methane to ethane ratio (C1 /C2 ) and the methane to ethane plus propane (C1 /(C2 +C3 )) decrease with depth down to at least 678 mbsf, mainly driven by the increase in ethane with depth. It is unclear if this trend continues through the Orange sand interval. The δ13C isotopic signature of methane ranges between -69.9 and -78.5 ‰ relative to the Vienna Pee Dee Belemnite (VPDB) standard. Pressure core recovery in sandy intervals was poor. However, pressure core logs of the Orange sand show intervals of low density and high velocity, which are indicative of high hydrate saturation. One pressure core was degassed and the average hydrate saturation in the core was determined to be 24%. One core from within the Orange sand was composed of interbedded graded sandy silt and mud. The sandy silts from this core are composed of mainly quartz and feldspar with some lithics. Most of the recovered pressure core samples are maintained at near in-situ pressure and temperature (within the hydrate stability field) at the University of Texas Pressure Core Center awaiting analysis. In the shallow section, samples will be used to determine the flux of organic carbon through the basin system, find the rate at which that carbon was consumed, and understand the microbial population responsible for these processes. In the deeper section, samples from in and around the hydrate reservoirs will be used to determine the petrophysical properties of the reservoir and bounding seals in these systems.

03 NATURAL GAS↗

High resolution variability in wet deposition in the southeastern United States

Rainwater chemistry is determined by atmospheric pollutants and particles which vary spatially and temporally. Industrial and agricultural activities and meteorological events (e.g. sea breezes, severe weather, blowing dust) alter atmospheric particle and trace gas compositions. These gases and particles are scavenged by cloud and rain droplets that drive wet deposition. During an Intensive Operation Period (IOP) from April to October 2021, rainwater was collected at higher frequency intervals, usually daily, after precipitation events at three locations on the Savannah River Site (SRS). The farthest locations were separated by approximately 20 km. The mean concentration (μeq/L) of seven ions followed the Cl⁻ > SO 4 2− > Na⁺ > NO 3 ⁻ > K⁺ > Mg 2+ > Ca 2+ downward trend. Ion concentrations were compared to background ion concentrations from the National Atmospheric Deposition Program (NADP). The high frequency monthly averaged SRS data compared well with the monthly averaged NADP background but demonstrated extensive variability. In some months in 2021, the high frequency data compared better to the NADP site near the coast while in other months inland sites compared better. Strong spatial variability for ion concentrations was observed across SRS which was attributed to localized impacts in rainfall spatial variability. High frequency measurements allowed for comparison to regional weather patterns indicating influences from the Atlantic Ocean, Gulf of Mexico, and cities. This can account for spatial variability in the wet deposition flux. Sea breezes, Saharan dust, and anthropogenic sources were shown to impact wet deposition flux variability. Higher frequency precipitation chemistry sampling at numerous locations better captures ion concentration variability and improves measurement representativeness.

54 ENVIRONMENTAL SCIENCES↗

Insights from Initial Engineering Designs of Point Source Capture at Industrial Facilities

Initial engineering design studies examining the application of state-of-the-art carbon capture technology at industrial plants contain generally overlooked real-world design considerations for near-term deployment of point source capture (PSC). The implementation of PSC across a wide range of industrial applications presents unique challenges associated with fluctuating CO<sub>2</sub> concentrations, flue gas composition, and utility and land availability. In this article, seven recent industrial retrofit PSC projects are reviewed to investigate the impact of site-specific factors on project design and cost. Across the seven projects, three capture technology classes and four industrial applications are considered, allowing insight into industry-specific opportunities for PSC technology synergy. Common challenges across projects and proposed design solutions are highlighted to propagate ideas and solutions to close the technology gaps and accelerate learning rates.

FEED Studies↗

Non-equilibrium plasma co-upcycling of waste plastics and CO 2 for carbon-negative oleochemicals

Mechanical recycling and chemical upcycling by thermochemical reactions have been the major approaches for recycling end-of-life plastics. Herein, we report an electrified approach to upcycle waste plastics into carbon-negative commodity chemicals using greenhouse gas CO 2 as the oxidant and additional carbon source. In this non-equilibrium plasma process, waste polyolefins were oxidatively depolymerized by plasma-activated CO 2 to produce oleochemicals and hydrocarbon chemicals in a single-step process at high reaction rates. In addition, a mixture of CO 2 and a small amount of O 2 was employed as plasma gases to selectively produce fatty alcohols from polyolefins. Based on this atmospheric pressure, non-solvent, and non-catalyst process, up to 97.6% of fatty alcohols could be produced within minutes. In this article, the co-conversion approach was demonstrated using common polyolefins and real-world mixed waste plastics to obtain comparable results. The techno-economic analysis estimates the internal rate of return to be 42.2% and 43.5% for the plasma-based conversion of waste plastics, depending on the plasma gas composition. Lifecycle assessment indicates the global warming potential is between −3.33 and −3.07 kg CO 2e per kg of plastic.

42 ENGINEERING↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Photochemically induced acousto-optics in gases

Acousto-optics consists of launching acoustic waves in a medium (usually a crystal) in order to modulate its refractive index and create a tunable optical grating. Here, in this article, we present the theoretical basis of an alternative scheme to generate acousto-optics in a gas, where the acoustic waves are initiated by the localized absorption (and thus gas heating) of spatially modulated UV light, as was demonstrated by Michine and Yoneda [Commun. Phys. 3, 24 (2020)]. We identify the chemical reactions initiated by the absorption of UV light via the photodissociation of ozone molecules present in the gas, and calculate the resulting temperature increase in the gas as a function of space and time. Solving the Euler fluid equations shows that the modulated, isochoric heating initiates a mixed acoustic-entropy wave in the gas, whose high-amplitude density (and thus refractive index) modulation can be used to manipulate a high-power laser. We calculate that diffraction efficiencies near 100% can be obtained using only a few millimeters of gas containing a few percent ozone fraction at room temperature, with UV fluences of less than 100 mJ/cm 2 —consistent with the experimental measurements. Our analysis suggests possible ways to optimize the diffraction efficiency by changing the buffer gas composition. Gases have optics damage thresholds 2–3 orders of magnitude beyond those of solids; these optical elements should therefore be able to manipulate kilojoule-class lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toluene Adsorption and TPD

Raw data for toluene adsorption and TPD experiments on two different adsorbents using a custom flow-through, bench-top reactor capable of controlling gas compositions and temperature.

36 MATERIALS SCIENCE↗

Multi-Parameter Optical Fiber for Distributed Sensing of Humidity, CH4, CO2, and Corrosion

This work describes the use of the optical fiber sensor (OFS) for successful monitoring of humidity, CH4, and CO2 based on the strain produced along the single-mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases onto the commercially available polyacrylate coated jacketed portion of the fiber resulting in a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different relative humidity (RH) conditions. The strain response of the SMF under various mixed gas composition and different RH conditions were also measured and made calibration curves accordingly. Linear regression and principal component analysis of the strain datasets provided deconvolution of the impact of strain from H2O, N2, CH4, and CO2. Additionally, modified OFS comprised of the Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion of Fe occurs. Also, corrosion of Fe was studied under soil by installing the fiber in soil with protective measures which would prevent the sensor being mechanically disturbed or broken during installation. The corrosion rates were studied by monitoring the rate at which the intensity of backscattered light amplitude attains a steady state value when complete corrosion of Fe with a specific coating thickness occurs.

Mainali, Badri↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visible Arc Emission Spectrometry During Pulsed-Current GMAW [Slides]

GBE Shielding Gas Disturbance Metric (GBESGDM) is sensitive to shielding gas disturbances caused by: (1) lack of shielding due to decreasing gas flow rate; (2) change in shielding gas composition; (3) dirty/contaminated base plate; and (4) changes in welding parameters.

36 MATERIALS SCIENCE↗

Mechanistic and Kinetic Analysis of Complete Methane Oxidation on a Practical PtPd/Al 2 O 3 Catalyst

A PtPd/Al 2 O 3 catalyst developed for the complete oxidation of methane from the ventilation air of underground coal mines is compared against a model PdO/Al 2 O 3 catalyst. Although the PtPd/Al 2 O 3 catalyst is substantially more active and stable than the model catalyst, the nature of active sites between the two catalysts is deemed to be fundamentally the same based on their response to different feed gas compositions and the evolution of surface CO adsorption complexes during time-resolved CO adsorption DRIFTS experiment. For both catalysts, coordinatively unsaturated Pd sites are considered the active centers for methane activation and the subsequent oxidation reaction. H 2 O competes with CH 4 for the same active sites, resulting in severe inhibition. Additionally, the CH 4 oxidation reaction also causes self-inhibition. Taking both inhibition effects into consideration, a relatively simple kinetic model is developed. The model provides a good fit of the 72 sets of kinetic data collected on the PtPd/Al 2 O 3 catalyst under practically relevant reaction conditions with CH 4 concentration in the range of 0.05–0.4%, H 2 O concentration of 1.0–5.0%, and reaction temperatures of 450–700 °C. Kinetic parameters based on the model suggest that the CH 4 activation energy on the PtPd/Al 2 O 3 catalyst is 96.7 kJ/mol, and the H 2 O adsorption energy is –31.0 kJ/mol. Both values are consistent with the parameters reported in the literature. The model can be used to develop catalyst sizing guidelines and be incorporated into the control algorithm of the catalytic system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Leveraging Observations of Untrained Panelists to Screen for Quality of Fresh-Cut Romaine Lettuce

Fresh-cut romaine lettuce’s high perishability challenges ready-to-eat (RTE) salad production. Selecting cultivars less prone to browning and decay is crucial for extending shelf life. Traditional quality evaluation methods using instrumentation and trained panelists are time-consuming and logistically complex. This study investigated the effectiveness of untrained volunteers in assessing fresh-cut romaine lettuce quality. Given that the average consumer in the USA is familiar with the flavor characteristics of romaine lettuce, this study proposed to investigate the value of having untrained volunteers discern the quality of fresh-cut romaine lettuce. Therefore, six romaine lettuce accessions (Green Forest, King Henry, Parris Island Cos, PI 491224, SM13-R2, and Sun Valley) were assessed for sensory quality attributes (browning, green color, decay, and overall quality) and compared with instrumentation analyses (gas composition including O2 and CO2, electrolyte leakage, and color). The results showed significant quality differences (p < 0.05) among the accessions, with some seasonal variability. Very importantly, the consumers’ (n = 159) assessments revealed similar results to those produced by either instrumentation or a trained panel. The consumers provided sensory scores that allowed for the grouping of accessions based on their postharvest quality, which efficiently matched their pedigree relationship. In conclusion, ad hoc consumer panels can be an effective way to characterize the quality of romaine lettuce for RTE salads.

Agriculture↗

Impact of Hydrogen on Methane and Pollutant Emissions over Three-Way Catalysts with Natural Gas–Hydrogen Blends

Blending natural gas (NG) with hydrogen (H₂) can improve combustion and engine performance while potentially facilitating the catalytic conversion of methane and other pollutants, resulting in cleaner tailpipe emissions. This study evaluates the impact of H2 on the conversion of methane, CO, and NOx emissions on a commercial three-way catalyst (TWC) in a flow reactor using synthetic gas mixtures that simulate stoichiometric engine exhausts with NG or NG+H₂ combustion. The work examines whether, and how, the additional amount of H₂ in the exhaust stream affects the conversion efficiency of methane and other pollutants. Experiments were conducted with both degreened and aged catalysts under controlled conditions, systematically varying temperature, the air-to-fuel equivalence ratio (λ), and λ modulation. Test conditions covered λ values from 0.996 to 1.000 to represent nominally stoichiometric engine operation with different λ modulation amplitudes, as well as a range of temperatures to inform control strategies for effective CH₄, CO, and NOₓ reduction. Overall, the results show that hydrogen addition significantly improves the conversion efficiency of CH₄ and NOₓ, particularly at temperatures below 500 °C. More significantly, this study highlights that exhaust gas composition, operating temperature, λ management, and the oxygen storage capacity of the TWC all play major roles in affecting the tailpipe emissions from NG and NG+H₂ combustion.

Prikhodko, Vitaly [ORNL] (ORCID:0000000244685836)↗