Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA ↗

Ultrahigh-precision Compton polarimetry at 2 GeV

Here we report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A precision of dP/P = 0.36% was achieved detecting the back-scattered photons from the Compton scattering process. This is the highest precision in a measurement of electron beam polarization using Compton scattering ever reported, surpassing the ground-breaking measurement from the SLD Compton polarimeter. Such precision reaches the level required for the future flagship measurements to be made by the MOLLER and SoLID Experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The contribution of Compton ionization to ultrafast x-ray scattering

We investigate the role of Compton ionization in ultrafast non-resonant x-ray scattering using a molecular model system, which includes the ionization continuum via an orthonormalized plane wave ansatz. Elastic and inelastic components of the scattering signal, as well as coherent-mixed scattering that arises from electron dynamics, are calculated. By virtue of a near-quantitative distinction between scattering related to electronic transitions into bound and continuum states, we demonstrate how Compton ionization contributes to the coherent-mixed component. Analogous to inelastic scattering, the contribution to the coherent-mixed signal is significant and particularly manifests at intermediate and high-momentum transfers. Strikingly, for molecules with inversion symmetry, the exclusion of bound or continuum transitions may lead to the prediction of spurious coherent-mixed signals. We conclude that qualitative and quantitative accuracies of predicted scattering signals on detectors without energy resolution require that elements of the two-electron density operator are used. This approach inherently accounts for all accessible electronic transitions, including ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of boundary conditions in quantum computations of scattering observables

Quantum computing may offer the opportunity to simulate strongly interacting field theories, such as quantum chromodynamics, with physical time evolution. This would give access to Minkowski-signature correlators, in contrast to the Euclidean calculations routinely performed at present. However, as with present-day calculations, quantum computation strategies still require the restriction to a finite system size, including a finite, usually periodic, spatial volume. In this work, we investigate the consequences of this in the extraction of hadronic and Compton-like scattering amplitudes. Using the framework presented in Briceño et al., we estimate the volume effects for various 1+1D Minkowski-signature quantities and show that these can be a significant source of systematic uncertainty, even for volumes that are very large by the standards of present-day Euclidean calculations. We then present an improvement strategy, based in the fact that the finite volume has a reduced symmetry. This implies that kinematic points, which yield the same Lorentz invariants, may still be physically distinct in the periodic system. As we demonstrate, both numerically and analytically, averaging over such sets can significantly suppress the unwanted volume distortions and improve the extraction of the physical scattering amplitudes. As the improvement strategy is based only in kinematics, it can be applied without detailed knowledge of the system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instrumental uncertainties in radiative corrections for the MUSE experiment

The MUSE experiment at the Paul Scherrer Institute is measuring elastic lepton-proton scattering cross sections in a four-momentum transfer range from Q 2 of approximately 0.002–0.08 GeV 2 using positively and negatively charged electrons and muons. The extraction of the Born cross sections from the experimental data requires radiative corrections. Estimates of the instrumental uncertainties in those corrections have been made using the ESEPP event generator. The results depend in particular on the minimum lepton momentum that contributes to the experimental cross section and the fraction of events with hard initial-state radiation that is detected in the MUSE calorimeter and is excluded from the data. Furthermore, these results show that the angular-dependent instrumental uncertainties in radiative corrections to the electron cross section are less than 0.4% and are negligible for the muon cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A model for radiative heating of a high-Z pusher

Several approaches to Inertial Confinement Fusion (ICF), including double-shell, pushered-single-shell, and the Revolver designs, have fuel surrounded by pushers made from high-Z materials. An advantage of these designs is that radiation emitted by the hot fuel will be absorbed and re-radiated into the fuel to reduce cooling. This process is referred to as radiation-trapping, and it lowers the fuel temperature required for ignition. To elucidate the physics of radiation trapping, a simplified model comprising a set of coupled differential equations has been developed to model the arbitrary time-dependent wall temperature from the Hammer and Rosen solution [J. H. Hammer and M. D. Rosen, Phys. Plasmas 10, 1829 (2003)] to a Marshak wave. The derivation of the model and a set of analytical power-law solutions will be presented. A discussion on numerical implementation of the differential equations into a model for burn in ICF capsules is also included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas scintillation mitigation in gas Cherenkov detectors for inertial confinement fusion (invited)

Gas Cherenkov detectors provide a time resolved measurement of the fusion burn in inertial confinement fusion experiments. The fusion rate delivers critical benchmark figures, such as burn width and bang time. Recent detector improvements pushed temporal resolution to 10 ps to make burn width measurements on igniting targets possible. First high temporal resolution measurements using CO 2 gas fills had a background signal with a long decay length (tail), which was caused by gas scintillation. This gas scintillation limits the ability of the detector to resolve short burn width and high frequency features in the fusion rate measurements. A thorough investigation of the cause of the tail and mitigation options for gas scintillation is presented here. As a near-term resolution, neon gas is being used to extract fusion burn histories. Paths forward for the next generation of gas Cherenkov detectors are identified including the usage of oxygen as a Cherenkov medium.

47 OTHER INSTRUMENTATION↗

International Workshop on Next Generation Gamma-Ray Source

A workshop on The Next Generation Gamma-Ray Sources , sponsored by the Office of Nuclear Physics at the Department of Energy, was held November 17--19, 2016 in Bethesda, Maryland. The goals of the workshop were to identify basic and applied research opportunities at the frontiers of nuclear physics that would be made possible by the beam capabilities of an advanced laser Compton beam facility. To anchor the scientific vision to realistically achievable beam specifications using proven technologies, the workshop brought together experts in the fields of electron accelerators, lasers, and optics to examine the technical options for achieving the beam specifications required by the most compelling parts of the proposed research programs. An international assembly of participants included current and prospective $\gamma$-ray beam users, accelerator and light-source physicists, and federal agency program managers. Sessions were organized to foster interactions between the beam users and facility developers, allowing for information sharing and mutual feedback between the two groups. The workshop findings and recommendations are summarized in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cherenkov Telescope Array sensitivity to the putative millisecond pulsar population responsible for the Galactic Centre excess

ABSTRACT The leading explanation of the Fermi Galactic Centre γ-ray excess is the extended emission from an unresolved population of millisecond pulsars (MSPs) in the Galactic bulge. Such a population would, along with the prompt γ-rays, also inject large quantities of electrons/positrons (e±) into the interstellar medium. These e± could potentially inverse-Compton (IC) scatter ambient photons into γ-rays that fall within the sensitivity range of the upcoming Cherenkov Telescope Array (CTA). In this article, we examine the detection potential of CTA to this signature by making a realistic estimation of the systematic uncertainties on the Galactic diffuse emission model at TeV-scale γ-ray energies. We forecast that, in the event that e± injection spectra are harder than E−2, CTA has the potential to robustly discover the IC signature of a putative Galactic bulge MSP population sufficient to explain the Galactic Centre excess for e± injection efficiencies in the range of ≈2.9–74.1 per cent, or higher, depending on the level of mismodelling of the Galactic diffuse emission components. On the other hand, for spectra softer than E−2.5, a reliable CTA detection would require an unphysically large e± injection efficiency of ${\gtrsim} 158{{\ \rm per\ cent}}$. However, even this pessimistic conclusion may be avoided in the plausible event that MSP observational and/or modelling uncertainties can be reduced. We further find that, in the event that an IC signal were detected, CTA can successfully discriminate between an MSP and a dark matter origin for the radiating e±.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced quantum radiation with flying-focus laser pulses

The emission of a photon by an electron in an intense laser field is one of the most fundamental processes in electrodynamics and underlies the many applications that utilize high-energy photon beams. This process is typically studied for electrons colliding head-on with a stationary-focus laser pulse. Here, we show that the energy lost by electrons in the quantum regime and the yield of emitted photons can be substantially increased by replacing a stationary-focus pulse with an equal-energy flying-focus pulse whose focus co-propagates with the electrons. Furthermore, these advantages of the flying focus result from the energy loss and the photon yield scaling more favorably with the interaction time than the laser intensity in the quantum regime, with the latter also holding in the classical regime. Monte Carlo simulations of electrons colliding with equal-energy stationary and flying-focus laser pulses demonstrate these advantages.

Compton scattering↗

Axion constraints from quiescent soft gamma-ray emission from magnetars

We report axion-like-particles (ALPs) emitted from the core of a magnetar can convert to photons in its magnetosphere. The resulting photon flux is sensitive to the product of (i) the ALP-nucleon coupling G an which controls the production cross section in the core and (ii) the ALP-photon coupling g aγγ which controls the conversion in the magnetosphere. We study such emissions in the soft-gamma-ray range (300 keV to 1 MeV), where the ALP spectrum peaks and astrophysical backgrounds from resonant Compton up scattering are expected to be suppressed. Using published quiescent soft-gamma-ray flux upper limits in five magnetars obtained with CGRO COMPTEL and INTEGRAL SPI/IBIS/ISGRI, we put limits on the product of the ALP-nucleon and ALP-photon couplings. We also provide a detailed study of the dependence of our results on the magnetar core temperature. We further show projections of our result for future Fermi-GBM observations. Our results motivate a program of studying quiescent soft-gamma-ray emission from magnetars with the Fermi-GBM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Longer-lived mediators from charged mesons and photons at neutrino experiments

Since many of the dark-sector particles interact with Standard Model (SM) particles in multiple ways, they can appear in experimental facilities where SM particles appear in abundance. In this study, we explore a particular class of longer-lived mediators that are dominantly produced from photons and charged mesons that arise in proton-beam fixed-target-type neutrino experiments. This class of mediators encompasses light scalars that appear in theories like extended Higgs sectors, muon(electro)philic scalars, etc. We evaluate the sensitivities of these mediators at beam-based neutrino experiments such as the finished ArgoNeuT, ongoing MicroBooNE, SBND, ICARUS, and the upcoming DUNE experiment. We find that muonphilic scalars are more enhanced while produced from three-body decay of charged mesons. The above-mentioned experiments can probe unexplored regions of parameter space that can explain the current discrepancy in the anomalous magnetic moment of muons. We further find that Compton-like scattering of photons is the largest source of electrophilic scalars. By utilizing this, the DUNE Near Detector can explore new regions in the sensitivity space of electrophilic scalars. We also show that Bethe-Heitler scattering processes can be used to probe flavor-specific lepton final states even for the mediator masses below twice the lepton mass. Published by the American Physical Society 2024

Astronomy & Astrophysics↗