Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CFD Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Modeling and analysis of heat emissions from buildings to ambient air

Heat emissions from buildings is a significant source of anthropogenic heat influencing the urban microclimate; however, they are usually oversimplified in urban climate and microclimate modeling. This study developed a bottom-up physics-based approach to calculate heat emissions from buildings to the ambient air and implemented the approach in EnergyPlus. In this work, a simple result verification was conducted by comparing the EnergyPlus simulated results against the spreadsheet calculations. Simulations covering 16 commercial building types, four climates, and two energy efficiency levels were conducted to understand and evaluate the building heat emissions and their temporal patterns as well as three major components: (1) building envelope (convective heat transfer to ambient air), (2) zones (air exfiltration and exhaust air), and (3) HVAC systems (relief air and heat rejection from condensers or cooling towers). The main findings are: (1) heat emissions are usually higher than the site energy use (about 2.5 times), and their dynamics should be considered; (2) building characteristics and their energy systems lead to differences in heat emission contributions from the three components, and their dynamics, for example, in the warehouse models, the envelope component accounts for 90.4%, while it is 12.7% for the large office models; (3) for most building typologies, the climate has a strong impact on heat emissions, for example, buildings with dominant heat emissions from the zone exhaust air and/or the HVAC reject heat, a general decrease in heat emissions in hotter climates is observed, while envelope-dominated buildings show the opposite; and (4) building technologies that reduce energy use in buildings may perform differently in reducing heat emissions. The developed heat emissions calculation method can be adopted in EnergyPlus and most other building energy modeling programs. It can provide dynamic building heat emissions as an input to urban climate computational fluid dynamics (CFD) models at a higher spatial and temporal resolution than is currently available, to improve the simulation accuracy of the urban microclimate and capture the urban heat island effect and urban overheating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Computational Fluid Dynamic Study on Polymer Heat Exchangers

Polymer heat exchangers have been developed for the applications involving weight restrictions or chemical compatibility and fouling issues owing to the low density, anticorrosive properties, and low thermal expansion of polymers. Recently development of additive manufacturing also brings new opportunities to make polymer heat exchangers with desired design that was hard to realize before. However, due to the lower thermal conductivity polymer composite, the overall heat transfer performance is still a challenge in the polymer heat exchanger technology. In present work, a computational fluid dynamic (CFD) model has been developed to study the overall heat transfer performance of additively manufactured polymer heat exchangers. The CFD results offer an insight of fluid flow and temperature distribution in the polymer heat exchangers. This study provides a guidance not only on the polymer material selection but also on the design of polymer heat exchangers. The conclusions will be helpful to design a polymer heat exchanger whose overall heat transfer performance is comparable to a metal heat exchanger.

Zhang, Mingkan↗

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

Design of high-deflection foils MHK applications - FEA models - Helical turbines

The Ocean Renewable Power Company's (ORPC's) goal is to design, develop, and test hydrofoils with large deflections. The effects of the deflections on cross-flow turbine performance would be evaluated in order to inform design considerations for full-scale water turbines and other marine hydrokinetic devices. FEA models - NASTRAN Helical foil turbines tested at UNH tow tank Glass and carbon composite material properties Loads derived from CFD models

16 TIDAL AND WAVE POWER↗

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microstructural and infiltration properties of woven preforms during chemical vapor infiltration

Interface-resolved direct numerical simulations (DNSs) of chemical vapor infiltration (CVI) have been performed over a range of furnace-operating conditions (Thiele moduli) and for practical woven preform geometries. A level-set method is used to resolve the geometry of the initial preform at tow scale. The interface between the vapor and solid phase is then evolved in time through the entire CVI densification cycle, fully resolving the time-varying topology between the two phases. In contrast to previous level-set methods for CVI simulation, the physical reaction and diffusion processes govern the level-set movement in the current approach. The surface deposition kinetics is described by the usual one-step model. In this paper, the DNS data are used to study the evolving porosity, surface-to-volume ratio, and flow infiltration properties (permeability and effective diffusivities). Additionally, comparisons are made to popularly-assumed structure functions and the standard, Kozeny–Carmen porous media model commonly employed in modeled CFD simulations of CVI. The virtual DNS experiments reveal a Thiele modulus and preform geometry (fabric layup) dependence which the existing microstructural and infiltration models are not able to describe throughout the entire densification process. The DNS-based, woven geometry-specific correlations can be applied directly to mean-field, furnace-scale CFD simulations.

36 MATERIALS SCIENCE↗

Machine Learning Based Prediction of Airflow Maldistribution in A-Type Heat Exchangers

Airflow maldistribution is one of the primary causes of performance degradation in air-to refrigerant heat exchangers (HX) and has been shown to decrease heat transfer by as much as 35%. As a result, many units are oversized to meet the target capacity, resulting in increased system cost and refrigerant charge. Several studies have explored how characteristics like package type and HX geometry impact the flow profile, but results are restricted to a limited range of parameters and cannot be extrapolated to new designs. In this work, a machine learning (ML) model is trained to predict the inlet flow profile of dry air entering A-type HXs across a broad range of geometries and conditions. Flow profiles are generated using a porous media CFD model and used to train an Artificial Neural Network (ANN) which exhibits maximum and average relative L2 norm errors of 0.48 and 0.05. Additionally, these predictions take less than a second to generate resulting in a speed up factor of 2.42E5 compared to CFD. Component-level simulations are conducted to determine the performance degradation resulting from the predicted airflow maldistribution profiles. The new ML model will enable rapid and accurate prediction of performance degradation resulting from airflow maldistribution in A-type HXs, allowing for more accurate and cost-effective HX design.

42 ENGINEERING↗

Hydrogen Dispersion Modeling for Development of Smart Distributed Monitoring

Studying hydrogen dispersion is crucial for ensuring the safe and effective deployment of hydrogen as an energy carrier. This study presents a comprehensive CFD modeling framework for simulating hydrogen dispersion at a real-world hydrogen production, storage, and utilization facility. Utilizing the Hydrogen Research Facility under the Advanced Research on Integrated Energy Systems (ARIES) at the National Renewable Energy Laboratory's (NREL) Flatirons campus, controlled hydrogen releases at 27 kg-H2/hr were simulated. The model incorporated site-specific atmospheric conditions, including hourly wind speeds and temperatures recorded between 8 AM and 8 PM from October to December 2023. To reduce computational demands, a statistical reduction technique was applied to condense the dataset to 100 representative scenarios, validated by statistical tests for wind speeds and power law coefficients. Simulations were conducted using the Reynolds-Averaged Navier-Stokes equations. Results demonstrated that wind speed substantially influences hydrogen dispersion, with low wind conditions forming concentrated clouds and higher wind speeds stretching the plume. Additionally, clustering analysis informed optimal sensor placement at various elevations with up to 10 sensor locations on each elevation. This framework offers a robust approach for understanding hydrogen behavior in ambient conditions and informing detection strategies.

08 HYDROGEN↗

Transport Analysis & Optimization in a MW-Scale CO2 Electrolyzer (Final Report)

As Twelve continues to scale up their CO2 electrolyzers, both in the size of a single cell and in the number of cells used in a stack, thermal management becomes a growing concern, since excess heat can affect reaction yield and accelerate degradation. In this project, we aim to computationally explore how the anode flow fields used in Twelve’s CO2 electrolyzers function as heat exchangers. In particular, using a homogenized model of a CO2 electrolyzer, we first estimate the amount of heat generated in a cell. Then, we develop a computational fluid dynamics (CFD) model of the so-called “flow field”, i.e. a flow manifold, based on Twelve’s CAD drawings, to evaluate how these flow fields perform as a heat exchanger for the generated heat. We explore both a single cell and a 3-cell stack operating in parallel, where heat generated in one cell can now be transferred to another cell. We evaluate how performance is affected when environmental heat losses are taken into account. Finally, we leverage topology optimization to explore the types of design features a computational optimization algorithm would suggest to supplement our intuition. Overall, our work aims to provide design recommendations for CO2 electrolyzer flow fields and provides a foundation for future studies of flow field optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ECAR-7210 Rev 0 Steady-state Thermo-mechanical Analysis of the MARVEL Fuel Bundle

This document reports the steady-state thermal-hydraulic and static mechanical analyses of the MARVEL micro-reactor core. The objective of this work is to investigate whether fuel-to-fuel contact could occur due to the thermal deformation of the fuel cladding during the normal operation and to assess the resulting impact on the peak cladding temperatures (PCT) if contact occurs. The scope of the work consists of three computational tasks. First, a conjugate heat transfer analysis using computational fluid dynamics (CFD) model was performed to evaluate the PCTs during normal operating conditions. Second, a finite element analysis (FEA) using the cladding temperature field obtained from the CFD analysis was performed to evaluate the thermal deformation of cladding and determine the occurrence of fuel-to-fuel contact. Finally, a CFD analysis of FEA-informed fuel-to-fuel gap (represented by a conservative 0.05 mm uniform gap) was performed to evaluate whether the PCT exceeds the safety criteria.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Modeling and simulation of multiphase flows

Multiphase flow can be found in a wide range of natural and industrial systems, such as sediment flow in rivers and coasts to pipeline transport, and reactors of all types. Computational fluid dynamics (CFD) modeling provides a rigorous physics-based method to visualize and quantify these flows and to assess their influence on their surroundings. This presentation will highlight computational research on two varied technologies in the energy sector: carbon capture and wellbore acoustics.

acoustic analysis↗

Computational Fluid Dynamics of Bioreactors with Micro-Aeration

Recent work has probed the potential for using Zymomonas mobilis as a flexible platform for the production of advanced fuels and intermediates. One set of recombinant organisms requires a micro-aerobic environment to promote the production of the desired product (2,3-BDO), but the economics and process-control implications of this approach are uncertain at industrial scale. Computational multi-physics models have the potential to describe the fermentation in detail at multiple scales, reducing the risk of scale-up. A two-phase Euler-Euler CFD model is used alongside a simple model of oxygen uptake to describe this bioreaction. A few reactor vessels, including airlift and CSTR bioreactors, are analyzed at multiple scales, regions of oxygen-depletion and over-oxygenation are characterized, and the bioreactors are compared. We show that it is difficult to achieve homogenous oxygen concentrations in industrial-scale CSTR reactors and that advanced bioreactor designs are needed for economical operation.

09 BIOMASS FUELS↗

Nitric oxide molecular tagging velocimetry of a free-flight model in a reflected shock tunnel

Nitric oxide molecular tagging velocimetry (NO MTV) is used to characterize the wake behind a free-flight spherical model in the test section of a free-piston reflected shock tunnel using a burst-mode laser operated at 100 kHz. A novel (to our knowledge) multi-delay timing scheme was implemented to measure velocity in a varying collisional environment in the wake of the free-flight model. Four simultaneous velocity profiles were measured in the wake of the model from -600 to 3600 m/s for flow enthalpies of 10.3 and 12.0 MJ/kg. Finally, the measured velocity distributions show good agreement when compared to computational fluid dynamics (CFD) modeling.

47 OTHER INSTRUMENTATION↗

Perovskite Sorbent Oxygen Separation Modeling with MFiX

This document chronicles the development and implementation of computational kinetic rate models that capture absorption and desorption characteristics of the National Energy Technology Laboratory (NETL) developed perovskite, Sr 1-x Ca x FeO 3-δ . Two paths to create accurate kinetic rates were followed: (1) an isothermal rate approach where thermogravimetric (TGA) data are recast as oxygen capacities through a pseudo-second order Lagergren equation (He et al., 2009); and (2) a more traditional Arrhenius approach where experimental data are fit with a power law model to derive associate activation energies (Bulfin et al., 2020a). For reference, the mathematics and associate experimental strategies that support these derivations are included in this report. In addition, computational fluid dynamics (CFD) models were developed to utilize both kinetic rate formulations and applied to simulate oxygen uptake and release in small scale scenarios. The program Multiphase Flow with interphase eXchanges (MFiX) was used to create: (1) discrete element method (DEM) simulations of a single tube of granular perovskite experiencing isothermal O 2 -absorption; and desorption and (2) two-fluid-model (TFM) non-isothermal simulations of perovskite O 2 -absorption and desorption tubes that share a wall. Conjugate heat transfer between steel walled tubes and the perovskite bed were managed with user-defined functions. As the project moves to simulating larger scale devices that will require more robust conjugate heat transfer methods, developed kinetic rates and associate methodologies have been recast for use in the ANSYS Fluent CFD program.

36 MATERIALS SCIENCE↗

A comprehensive numerical investigation on spray models for Direct-Injection Spark-Ignition engines

Gasoline direct-injection spark-ignition (DISI) engines generate a large portion of their unburned hydrocarbon (UHC) and soot emissions during the cold-start phase. A predictive computational fluid dynamics (CFD) modeling framework can be used to understand the physical processes that characterize fuel spray evolution and fuel-film formation at cold start conditions, which can help to reduce engine-out particulate emissions. This study systematically evaluated spray submodels and developed a set of simulation best practices for physical-numerical submodels with the goal of enabling accurate simulations of liquid spray behavior in a DISI engine. Three comprehensive experimental datasets containing free-spray projected liquid volume (PLV), liquid volume fraction (LVF), and near-field X-ray radiography data were used to validate the simulation results and evaluate the spray submodels. Systematic analysis delved into injected parcel distribution, droplet collision, spray breakup, and evaporation via a detailed assessment of the relevant spray submodels. Moreover, the effects of turbulence models and the initial turbulent flow properties on the liquid spray evolution were examined. Based on extensive calibration efforts, a set of simulation best practices for the free spray was developed and validated against the PLV/LVF data. Simulation results indicated that the uniform distribution for parcel initialization, coupled with appropriate droplet collision submodels, provides an improved spray morphology compared to the cluster distribution. The findings also underscored the importance of calibrating the Kelvin-Helmholtz Rayleigh-Taylor (KH-RT) breakup model constants and droplet heat transfer coefficient scaling factor to achieve favorable agreement regarding measured liquid penetration and spray widths. In conclusion, this study marks a substantial stride towards accurately predicting fuel film evolution and soot formation within DISI engine performance.

ECN Spray G↗

A Study of Propane Combustion in a Spark-Ignited Cooperative Fuel Research (CFR) Engine

Liquefied petroleum gas (LPG), whose primary composition is propane, is a promising candidate for heavy-duty vehicle applications as a diesel fuel alternative due to its CO 2 reduction potential and high knock resistance. To realize diesel-like efficiencies, spark-ignited LPG engines are proposed to operate near knock-limit over a wide range of operating conditions, which necessitates an investigation of fuel-engine interactions that leads to end-gas autoignition with propane combustion. This work presents both experimental and numerical studies of stoichiometric propane combustion in a sparkignited (SI) cooperative fuel research (CFR) engine. Engine experiments are initially conducted at different compression ratio (CR) values, and the effects of CR on engine combustion are characterized. A three-pressure analysis (TPA) model based on the two-zone combustion concept is developed in GT-Power and validated using test results to estimate in-cylinder wall temperatures, residual gas fraction, etc. This model is further utilized to examine end-gas chemistry by enabling the SI turbulent flame combustion and unburned gas chemical kinetics modules. Finally, a three-dimensional (3D) computational fluid dynamic (CFD) model of the CFR engine is developed in CONVERGE, where the G-equation and SAGE detailed chemical kinetics models are implemented for combustion modeling. Here, a 153 species reduced chemical kinetics mechanism derived from the detailed NUIGMech1.1 mechanism based on the ignition delay and laminar flame speed (LFS) studies is used to generate an LFS lookup table and to describe end-gas autoignition chemistry. Multi-cycle Reynolds-averaged Navier-Stokes (RANS) simulations are then performed for the tested CRs, and the numerical model is shown to be capable of predicting the propane combustion characteristics, particularly the end-gas autoignition behavior.

20 FOSSIL-FUELED POWER PLANTS↗

Electron Beam Irradiation for Water Treatment of Per- and Polyfluoroalkyl Substances (PFAS)

Per- and polyfluoroalkyl substances (PFAS) are widely used but are now considered a water contamination risk. Fermi National Accelerator Laboratory’s IARC group has demonstrated that passing water through electron beam radiation can destroy PFAS. This project aims to develop a process to scale the system for bulk water treatment. The key is efficient radiation usage, ensuring that all water receives only the minimum dose. Software was developed for this purpose, consisting of a computational fluid dynamics model (CFD) in COMSOL, which calculates particle trajectories through the radiation area. A MATLAB script integrates the radiation dose of these particles, and statistical analysis is performed to evaluate the radiation utilization efficiency. These models are validated with a flow test where colored dye is injected and optically tracked. Radiation dose is measured by testing under an e-beam to measure the degradation of a PFAS analog.

Mueller, Scott [Northern Illinois U.]↗