Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INSTALLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

The Mu2e Calorimeter

The EM CsI crystals and SiPM readout calorimeter of the Mu2e experiment is fully assembled, with all components completed and tested; the mechanical structure is fully built, with a complete integration and test of all the analog sensors and electronics. The digital electronics is being produced and installed. We summarise the Calorimeter characteristics and the assembly status, as well as the move, installation and commissioning plans of the final disks in the Mu2e hall.

Borrel, L. [Caltech]↗

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗

First Offline Results from the S3 Low-Energy Branch

We present the first results obtained from the S3 Low-Energy Branch, the gas cell setup at SPIRAL2-GANIL, which will be installed behind the S3 spectrometer for atomic and nuclear spectroscopy studies of exotic nuclei. The installation is currently being commissioned offline, with the aim to establish optimum conditions for the operation of the radio frequency quadrupole ion guides, mass separation and ion bunching, providing high-efficiency and low-energy spatial spread for the isotopes of interest. Transmission and mass-resolving power measurements are presented for the different components of the S3-LEB setup. In addition, a single-longitudinal-mode, injection-locked, pumped pulsed-titanium–sapphire laser system has been recently implemented and is used for the first proof-of-principle measurements in an offline laser laboratory. Laser spectroscopy measurements of erbium, which is the commissioning case of the S3 spectrometer, are presented using the 4f126s23H6→4f12(3H)6s6p optical transition.

Romans, Jekabs (ORCID:0000000197427745)↗

Degradation of Insulating Glass Units: Thermal Performance, Measurements and Energy Impacts

Insulating glass unit (IGU) degradation has been studied extensively. However, there is limited understanding of how present durability evaluation standards relate to product lifetime. Furthermore, there is debate on how to quantify performance of installed windows over time to better understand degradation processes. More knowledge on these topics is required to link durability evaluation to product lifetime projections based on energy performance. Energy models provide helpful estimations of total annual building energy consumption. However, most models are based on “as installed” performance of envelope components and fail to account for performance degradation. This can lead to an underestimation of building lifetime energy consumption. A better understanding of the relationship between durability and energy performance can inform integration of degradation dynamics into energy modeling software. This will improve lifetime building energy consumption estimations as well as inform appropriate retrofit strategies and timing. This paper reviews current durability literature, various standards for window performance ratings and weathering methods, existing in situ IGU energy performance measurement techniques, and whole-building energy effects. The challenges and disparities among various studies are analyzed and discussed. The authors hope that further work in this area will lead to the development of improved in situ test methods to assess IGU degradation in the field and link this knowledge to improved energy performance modeling approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Modeling, Trajectory Optimization, and Linear Control of Cable-Driven Parallel Robots for Automated Panelized Building Retrofits

The construction industry faces a growing need for automation to reduce costs, improve accuracy and productivity, and address labor shortages. One area that stands to benefit significantly from automation is panelized prefabricated building envelope retrofits, which can improve a building’s energy efficiency in heating and cooling interior spaces. In this paper, we propose using cable-driven parallel robots (CDPRs), which can effectively lift and handle large objects, to install these panels. However, implementing CDPRs presents significant challenges because of their nonlinear dynamics, complex trajectory planning, and precise control requirements. To tackle these challenges, this work focuses on a new application of established control and trajectory optimization theories in a CDPR simulation of a building envelope retrofit under real-world conditions. We first model the dynamics of CDPRs, highlighting the critical role of damping in system behavior. Building on this dynamic model, we formulate a trajectory optimization problem to generate feasible and efficient motion plans for the robot under operational and environmental constraints. Given the high precision required in the construction industry, accurately tracking the optimized trajectory is essential. However, challenges such as partial observability and external vibrations complicate this task. To address these issues, a Linear Quadratic Gaussian control framework is applied, enabling the robot to track the optimized trajectories with precision. Simulation results show that the proposed controller enables precise end effector positioning with errors under 4 mm, even in the presence of external wind disturbances. Through comprehensive simulations, our approach allows for an in-depth exploration of the system’s nonlinear dynamics, trajectory optimization, and control strategies under controlled yet highly realistic conditions. The results demonstrate the feasibility of CDPRs for automating panel installation and provide insights into their practical deployment.

CDPR↗

Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings

Light-emitting diodes (LED) fixtures and lamps have emerged as leading technologies for general illumination and are a well-established energy efficiency retrofit measure in commercial buildings (from around 2% of installed fixtures and lamps in 2013 to 28% by 2020). Retrofit approaches that integrate elements, such as networked controls, daylight dimming, and advanced shade technologies lag in comparison. Integrated retrofits have been shown to increase savings over single end-use retrofits, but are perceived as higher complexity and risk. More validation of integrated lighting system performance is needed. This study presents results from laboratory testing of three packages combining fixtures, networked controls, task tuning, and daylight dimming, advanced shades, and lighting layout changes. We characterize performance in perimeter open-office zones, finding energy savings from 20% for daylight dimming and automated shades (no LED retrofit) to over 70% for LED retrofits with advanced controls and shades or lighting layout changes. We present some implementation details, including lessons learned from installation and commissioning in the laboratory setting. We also discuss cost-benefit analysis approaches for the types of packages presented, including the need to quantify and incorporate energy and non-energy benefits for advanced shades packages, which enhance occupant comfort but add significant cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Marine Energy Environmental Permitting and Compliance Costs

Costs to permit Marine Energy projects are poorly understood. In this paper we examine environmental compliance and permitting costs for 19 projects in the U.S., covering the last 2 decades. Guided discussions were conducted with developers over a 3-year period to obtain historical and ongoing project cost data relative to environmental studies (e.g., baseline or pre-project site characterization as well as post-installation effects monitoring), stakeholder outreach, and mitigation, as well as qualitative experience of the permitting process. Data are organized in categories of technology type, permitted capacity, pre- and post-installation, geographic location, and funding types. We also compare our findings with earlier logic models created for the Department of Energy (i.e., Reference Models). Environmental studies most commonly performed were for Fish and Fisheries, Noise, Marine Habitat/Benthic Studies and Marine Mammals. Studies for tidal projects were more expensive than those performed for wave projects and the range of reported project costs tended to be wider than ranges predicted by logic models. For eight projects reporting full project costs, from project start to FERC or USACE permit, the average amount for environmental permitting compliance was 14.6%.

16 TIDAL AND WAVE POWER↗

Monitoring of Liquid Metal Reactor Heater Zones with Recurrent Neural Network Learning of Temperature Time Series

Advanced high-temperature fluid reactors (ARs), such as sodium fast reactors (SFRs) and molten salt cooled reactors (MSCRs) utilize high-temperature fluids at ambient pressure. To melt the fluid during reactor startup and prevent fluid freezing during cooldown, the thermal–hydraulic systems of such ARs include heater zones consisting of specific heaters with controllers, temperature sensors, and thermal insulation. The failure of heater zones due to insulation material degradation or improper installation, resulting in parasitic heat losses, can lead to fluid freezing. The detection of faults using a heat-transfer model is difficult because of a lack of knowledge of the experimental details. Data-driven machine learning of heater zone temperature time series offers a viable alternative. In this study, we benchmarked the performance of recurrent neural networks (RNNs) in an analysis of heat-up transient temperature time series of heater zones installed on a liquid sodium vessel. The RNN models include long short-term memory (LSTM) and gated recurrent unit (GRU) networks, as well as their bi-directional variants, BiLSTM and BiGRU. Anomalous temperature points were designated using a percentile-based threshold applied to residual fluctuations in the detrended temperature time series. Additionally, the impact of the exponentially weighted moving average (EWMA) method on detection accuracy was examined. The RNN models’ performance was assessed using precision, recall, and F 1 score metrics. Results demonstrated that RNN models effectively detect anomalies in temperature time series with the best models for each heater zone achieving F 1 scores of over 93%. To explain the variations in RNN model performance across different heater zones, we used Kullback–Leibler (KL) divergence to quantify the relative entropy between training and testing data, and the Detrended Fluctuation Analysis (DFA) to assess long-range temporal correlations. For datasets with strong long-range correlations and minimal relative entropy between training and testing data, GRU is the best-performing model. When the data exhibits weaker long-term correlations and a significant relative entropy between training and testing distributions, BiGRU shows the best performance. For the data sets with intermediate values of both KL divergence and DFA, the best performance is obtained with LSTM and BiLSTM, respectively.

gated recurrent unit↗

What’s in My Toolkit? A Review of Technologies for Assessing Changes in Habitats Caused by Marine Energy Development

Marine energy devices are installed in highly dynamic environments and have the potential to affect the benthic and pelagic habitats around them. Regulatory bodies often require baseline characterization and/or post-installation monitoring to determine whether changes in these habitats are being observed. However, a great diversity of technologies is available for surveying and sampling marine habitats, and selecting the most suitable instrument to identify and measure changes in habitats at marine energy sites can become a daunting task. We conducted a thorough review of journal articles, survey reports, and grey literature to extract information about the technologies used, the data collection and processing methods, and the performance and effectiveness of these instruments. We examined documents related to marine energy development, offshore wind farms, oil and gas offshore sites, and other marine industries around the world over the last 20 years. A total of 120 different technologies were identified across six main habitat categories: seafloor, sediment, infauna, epifauna, pelagic, and biofouling. The technologies were organized into 12 broad technology classes: acoustic, corer, dredge, grab, hook and line, net and trawl, plate, remote sensing, scrape samples, trap, visual, and others. Visual was the most common and the most diverse technology class, with applications across all six habitat categories. Technologies and sampling methods that are designed for working efficiently in energetic environments have greater success at marine energy sites. In addition, sampling designs and statistical analyses should be carefully thought through to identify differences in faunal assemblages and spatiotemporal changes in habitats.

16 TIDAL AND WAVE POWER↗

Minimizing Ecological Impacts of Marine Energy Lighting

Marine energy is poised to become an important renewable energy contributor for the U.S., but widespread deployment of the technology hinges on its benefits outweighing the potential ecological impacts. One stressor marine energy installations introduce is light, which is known to cause varying responses among wildlife and has not yet been addressed as an environmental concern. This review discusses requirements and regulations for similar structures and how lighting design choices can be made to meet these requirements while minimizing environmental consequences. More practical guidance on implementing lighting for marine energy is needed, as well as updated guidelines to reflect technological and research advances. Known responses of wildlife to light are introduced in addition to how the responses of individuals may lead to ecosystem-level changes. The impact of light associated with marine energy installations can be reduced by following basic guidance provided herein, such as removing excess lighting, using lights with high directionality, and employing controls to reduce light levels. Continued research on animal responses to light, such as findings on minimum light levels for animal responses, alongside the development of highly-sensitivity spectral characterization capabilities can further inform lighting guidelines for deploying future open ocean marine energy devices.

54 ENVIRONMENTAL SCIENCES↗

Investigating a Renewable-Resource-Targeting Mobile Aquaculture System Using Route Optimization Based on Optimal Foraging Theory

Aquaculture systems require careful consideration of location, which determines water conditions, pollution impacts, and hazardous conditions. Mobility may be able to address these factors while also supporting the targeting of renewable energy sources such as wind, wave, and solar power throughout the year. In this paper, a purpose-built mobile aquaculture ship is identified and modeled with a combination of renewable energy harvesting capabilities as a case study with the objective of assessing the potential benefits of targeting high renewable energy potentials to power aquaculture operations. A route optimization algorithm is created and tuned to simulate the mobility of the aquaculture platform and cost-basis comparisons are made to a stationary system. The small spatial variability in renewable energy potential when combining multiple resources significantly limits the benefits of a mobile, renewable-targeting aquaculture system. On the other hand, the consistent energy harvest from a blend of renewable energy types (13 kW installed wind capacity, 661 m 2 installed solar, and 1 m characteristic width wave-energy converter) suggests that the potential benefits of a mobile platform for offshore aquaculture (mitigation of environmental and social concerns, any potential positive impact on yields, hazard avoidance, etc.) can likely be pursued without significant increases in energy harvester costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tunable White Light for Elders (TWLITE): A Protocol Demonstrating Feasibility and Acceptability for Deployment, Remote Data Collection, and Analysis of a Home-Based Lighting Intervention in Older Adults

Sleep disturbances are common in older adults and may contribute to disease progression in certain populations (e.g., Alzheimer’s disease). Light therapy is a simple and cost-effective intervention to improve sleep. Primary barriers to light therapy are: (1) poor acceptability of the use of devices, and (2) inflexibility of current devices to deliver beyond a fixed light spectrum and throughout the entirety of the day. However, dynamic, tunable lighting integrated into the native home lighting system can potentially overcome these limitations. Herein, we describe our protocol to implement a whole-home tunable lighting system installed throughout the homes of healthy older adults already enrolled in an existing study with embedded home assessment platforms (Oregon Center for Aging & Technology—ORCATECH). Within ORCATECH, continuous data on room location, activity, sleep, and general health parameters are collected at a minute-to-minute resolution over years of participation. This single-arm longitudinal protocol collected participants’ light usage in addition to ORCATECH outcome measures over a several month period before and after light installation. The protocol was implemented with four subjects living in three ORCATECH homes. Technical/usability challenges and feasibility/acceptability outcomes were explored. The successful implementation of our protocol supports the feasibility of implementing and integrating tunable whole-home lighting systems into an automated home-based assessment platform for continuous data collection of outcome variables, including long-term sleep measures. Challenges and iterative approaches are discussed. This protocol will inform the implementation of future clinical intervention trials using light therapy in patients at risk for developing Alzheimer’s disease and related conditions.

60 APPLIED LIFE SCIENCES↗

Four-Stage Multi-Physics Simulations to Assist Temperature Sensor Design for Industrial-Scale Coal-Fired Boiler

The growth of renewable energy sources presents a pressing challenge to the operation and maintenance of existing fossil fuel power plants, given that fossil fuel remains the predominant fuel source, responsible for over 60% of electricity generation in the United States. One of the main concerns within these fossil fuel power plants is the unpredictable failure of boiler tubes, resulting in emergency maintenance with significant economic and societal consequences. A reliable high-temperature sensor is necessary for in situ monitoring of boiler tubes and the safety of fossil fuel power plants. In this study, a comprehensive four-stage multi-physics computational framework is developed to assist the design, optimization installation, and operation of the high-temperature stainless-steel and quartz coaxial cable sensor (SSQ-CCS) for coal-fired boiler applications. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. With the simulation-guided sensor installation plan, the newly designed SSQ-CCSs have been employed for field testing for more than 430 days. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

42 ENGINEERING↗

Post-Calibration Uncertainty Analysis for Travel Times at a Naval Weapons Industrial Reserve Plant

The Naval Weapons Industrial Reserve Plant (NWIRP) in McGregor, Texas began manufacturing explosives in 1980 and several hazardous chemicals were discovered in lakes and streams surrounding the site in 1998. Contaminants traveled to local lakes and streams much faster than initially predicted. This research estimated contaminant travel times and identified locations where monitoring wells should be installed to yield the greatest reductions in uncertainties in travel-time predictions. To this end, groundwater and particle-tracking models for NWIRP site were built to predict hydraulic heads and contaminant travel times. Next, parameter (hydraulic conductivities) uncertainties, parameter identifiabilities, observation (hydraulic heads) worth, and predictive (contaminant travel times) uncertainties were quantified. Parameter uncertainties were reduced by up to 92%; a total of 19 of 158 parameters were at least moderately identifiable; travel-time uncertainties were reduced up to 92%. Additionally, travel-time predictions and post-calibration parameter distributions were generated using the null-space Monte Carlo (NSMC) technique. NSMC predicted that conservative tracers exited the flow system within a year, which matches with field data. Finally, an observations-worth analysis found that additional 11 more measurements would reduce travel-time uncertainties by factors from 1.04 to 4.3 over existing data if monitoring wells were installed at the suggested locations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Examination of an Electrified Bar Rack Fish Guidance Device for Hydropower Turbines

The potential of hydropower turbines to cause injury or mortality to fish is a concern. To reduce this risk, engineers have begun to develop a conically arranged, cantilevered electrified bar rack (Center Sender). This device is proposed to be mounted within the intake of a turbine, guiding downstream-passing fish towards the center of the turbine where blade velocities are lower and blades are thicker, likely reducing the potential for fish to be injured. A simplified version was installed in a flume for testing with Rainbow trout (Oncorhynchus mykiss) while examining several parameters such as electrification, bar spacing, bar angle, and water velocity. The most effective settings were observed to be a water velocity of 1.0 m s -1 with all bars installed at an angle of 40° with electrification on. Other combinations were still effective but had varying results. A minimal proportion (2.3%) of fish passed at lower velocities with bars electrified and mounted at 20°, suggesting that while it functions well as a guidance device in high-velocity conditions, it performs better as a barrier at lower velocities. The study suggests that the Center Sender has promising potential for reducing the harmful effects of hydropower turbines on fish populations by guiding them away from stressors. Further research is needed, but current results encourage its potential use in hydropower operations.

13 HYDRO ENERGY↗

A Comprehensive Assessment Tool for Low-TRL Current Energy Converters

Along with a market-competitive levelized cost of energy, a current energy converter technology strongly benefits from an extensive consideration of socioeconomic, environmental, and regulatory factors early in the design process. As part of a technology performance level assessment, a series of assessment questions and guidance are developed and presented to evaluate an early-stage current energy technology on holistic criteria considering the entire device lifecycle. The assessment represents an accumulation of industry and research experience to date and relies on regular updates to ensure alignment with industry best-practices, regulatory requirements, and up-to-date technical understanding. A cradle-to-grave (materials, manufacturing, installation and deployment, operations and maintenance, and end-of-life) assessment of capabilities and functional requirements (i.e., high, medium, and low) performance criteria for current energy converters deployed in tidal, ocean current, and/or river applications. Key considerations related to manufacturing and installation include supply chain robustness, manufacturability and related job creation in the end-user and/or adjacent communities, and the time-to-repayment of the embodied energy debt. During deployment and maintenance operations, the safety of the device and subsystems during disconnect or grid failure, the difficulty and frequency of offshore heavy-lift activities, the avoidance or mitigation of area-use conflicts, the sea-states and weather conditions that permit maintenance access, and the availability of contingency plans (should conditions change unexpectedly) are a portion of the considered assessment criteria. Results include the potential impact of early-stage design decisions on the socioeconomic, environmental, and regulatory performance of a technology that allows developers to increase the product value and probability of success, and minimize costly late-stage design iterations through early and broad consideration of factors affecting overall performance and acceptability.

life cycle analysis↗

Refine your search to explore more results.