Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage indices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

New Computer Simulations of Macular Neural Functioning

We use high performance graphics workstations and supercomputers to study the functional significance of the three-dimensional (3-D) organization of gravity sensors. These sensors have a prototypic architecture foreshadowing more complex systems. Scaled-down simulations run on a Silicon Graphics workstation and scaled-up, 3-D versions run on a Cray Y-MP supercomputer. A semi-automated method of reconstruction of neural tissue from serial sections studied in a transmission electron microscope has been developed to eliminate tedious conventional photography. The reconstructions use a mesh as a step in generating a neural surface for visualization. Two meshes are required to model calyx surfaces. The meshes are connected and the resulting prisms represent the cytoplasm and the bounding membranes. A finite volume analysis method is employed to simulate voltage changes along the calyx in response to synapse activation on the calyx or on calyceal processes. The finite volume method insures that charge is conserved at the calyx-process junction. These and other models indicate that efferent processes act as voltage followers, and that the morphology of some afferent processes affects their functioning. In a final application, morphological information is symbolically represented in three dimensions in a computer. The possible functioning of the connectivities is tested using mathematical interpretations of physiological parameters taken from the literature. Symbolic, 3-D simulations are in progress to probe the functional significance of the connectivities. This research is expected to advance computer-based studies of macular functioning and of synaptic plasticity.

Ross, Muriel D.↗

Proton radiation effects on electronic defect states in MOCVD-grown (010) β -Ga 2 O 3

The impact of 1.8 MeV proton irradiation on metalorganic chemical vapor deposition grown (010) β-Ga 2 O 3 Schottky diodes is presented. It is found that after a 10.8 × 10 13 cm –2 proton fluence the Schottky barrier height of (1.40 ± 0.05 eV) and the ideality factor of (1.05 ± 0.05 ) are unaffected. Capacitance–voltage extracted net ionized doping curves indicate a carrier removal rate of 268 ± 10 cm –1 . The defect states responsible for the observed carrier removal are studied through a combination of deep level transient and optical spectroscopies (DLTS/DLOS) as well as lighted capacitance–voltage (LCV) measurements. The dominating effect on the defect spectrum is due to the E c -2.0 eV defect state observed in DLOS and LCV. This state accounts for ~75 % of the total trap introduction rate and is the primary source of carrier removal from proton irradiation. Of the DLTS detected states, the E c -0.72 eV state dominated but had a comparably smaller contribution to the trap introduction. These two traps have previously been correlated with acceptor-like gallium vacancy-related defects. Several other trap states at E C -0.36, E C -0.63, and E C -1.09 eV were newly detected after proton irradiation, and two pre-existing states at E C -1.2 and E C -4.4 eV showed a slight increase in concentration after irradiation, together accounting for the remainder of trap introduction. However, a pre-existing trap at E c -0.40 eV was found to be insensitive to proton irradiation and, therefore, is likely of extrinsic origin. Furthermore, the comprehensive defect characterization of 1.8 MeV proton irradiation damage can aid the modeling and design for a range of radiation tolerant devices.

42 ENGINEERING↗

An electrohydrodynamic heat pipe.

A heat pipe of new design, using an electrode structure to orient and guide the dielectric liquid phase flow, is proposed. Analysis indicates that the operation of the electrohydrodynamic heat pipe is in direct analogy to capillary devices, with the polarization force acting in place of capillarity. Advantages of these new heat pipes include greatly reduced liquid friction, electrohydrodynamically enhanced evaporation and condensation heat transfer, and a possible voltage-controlled on/off feature. Preliminary calculations indicate that relatively high performance devices are possible.

Jones, T. B.↗

Macro Fiber Piezocomposite Actuator Poling Study

The performance and advantages of Piezocomposite Actuators are to provide a low cost, in-situ actuator/sensor that is flexible, low profile and high strain per volt performance in the same plane of poled voltage. This paper extends reported data for the performance of these Macrofiber Composite (MFC) Actuators to include 4 progressively narrower Intedigitized electrode configurations with several line widths and spacing ratios. Data is reported for max free strain, average strain per applied volt, poling (alignment of the electric dipoles of the PZT ceramic) voltage vs. strain and capacitance, time to poling voltage 95% saturation. The output strain per volt progressively increases as electrode spacing decreases, with saturation occurring at lower poling voltages. The narrowest spacing ratio becomes prone to voltage breakdown or short circuits limiting the spacing width with current fabrication methods. The capacitance generally increases with increasing poling voltage level but has high sensitivity to factors such as temperature, moisture and time from poling which limit its usefulness as a simple indicator. The total time of applied poling voltage to saturate or fully line up the dipoles in the piezoceramic was generally on the order of 5-20 seconds. Less sensitivity to poling due to the applied rate of voltage increase over a 25 to 500 volt/second rate range was observed.

Werlink, Rudy J.↗

Redox gating-induced modulation of charge carrier density and lattice expansion in LaNiO 3 thin films

Redox gating involves the use of reversible redox functionalities combined with ionic electrolytes to substantially alter the charge carrier density in functional condensed materials. This modification leads to the emergence of physical properties not observed in the original material. Here, in our study, we focus on redox gating applied to a LaNiO 3 (001) film within a field-effect device and identify a critical gate voltage of 0.7 V. Hall measurements indicate that redox gating markedly increases the charge carrier density in LaNiO 3 , reaching over 10 14 cm −2 . This increase is primarily due to the injection of electrons into LaNiO 3 , which offsets the existing hole carriers. These adjustments in the carrier concentration result in reversible lattice expansion in LaNiO 3 when gate voltages are below 0.7 V. This expansion correlates well with theoretical models that consider adjustments to the Ni–O bond length, influenced by oxygen ligand holes. Conversely, at gate voltages above 0.7 V, there are significant changes in resistivity, lattice structure, and Ni valence, stemming from the formation of oxygen vacancies in the LaNiO 3 film.

36 MATERIALS SCIENCE↗

Error analysis in the measurement of average power with application to switching controllers

Power measurement errors due to the bandwidth of a power meter and the sampling of the input voltage and current of a power meter were investigated assuming sinusoidal excitation and periodic signals generated by a model of a simple chopper system. Errors incurred in measuring power using a microcomputer with limited data storage were also considered. The behavior of the power measurement error due to the frequency responses of first order transfer functions between the input sinusoidal voltage, input sinusoidal current, and the signal multiplier was studied. Results indicate that this power measurement error can be minimized if the frequency responses of the first order transfer functions are identical. The power error analysis was extended to include the power measurement error for a model of a simple chopper system with a power source and an ideal shunt motor acting as an electrical load for the chopper. The behavior of the power measurement error was determined as a function of the chopper's duty cycle and back EMF of the shunt motor. Results indicate that the error is large when the duty cycle or back EMF is small. Theoretical and experimental results indicate that the power measurement error due to sampling of sinusoidal voltages and currents becomes excessively large when the number of observation periods approaches one-half the size of the microcomputer data memory allocated to the storage of either the input sinusoidal voltage or current.

Maisel, J. E.↗

A parametric analysis of oilfield design factors affecting the detectability and characterization of electrically conductive hydrofracks

Electrical responses in the vicinity of energized steel-cased well sources offer significant potential for monitoring induced fractures. However, the high complexity of well-fracture-host models spanning multiple length scales compels analysts to simplify their numerical models due to enormous computational costs. This consequently limits our understanding regarding monitoring capabilities and the limitations of electrical measurements on realistic hydraulically fracturing systems. In this paper, we use the hierarchical finite element approach to construct geoelectric models in which geometrically complex fractures and steel-cased wells are discretely represented in 3D conducting media without sacrificing the model realism and computation efficiency. We have discovered systematic numerical analyses of the electrical responses to evaluate the influences of borehole material conductivity and the source type as well as the effects of well geometry, conductivity contrast, source location, fracture growth, and fracture propagation. Furthermore, the numerical results indicate that the borehole material property has a strong control on the electrical potentials along the production and monitoring wells. The monopole source located at a steel-cased well results in a current density distribution that decays away from the source location throughout the well length, whereas the dipole source produces a current density that dominates mainly along the dipole length. Moreover, the conductivity contrast between the fractures and host does not change the overall pattern of the electrical potentials but varies its amplitude. The fracture models near different well systems indicate that the well geometry controls the entire distribution of potentials, while the characteristics of the voltage difference profiles along the wells before and after fracturing are insensitive to the well geometry and the well in which the source is located. Further, the hydraulic-fracturing models indicate that the voltage differences along the production well before and after fracturing have strong sensitivity to fracture growth and fracture set propagation.

58 GEOSCIENCES↗

High Voltage Surge Protection by a Varistor-Filled Air Gap

The electric discharge across a varistor granule filled air gap under a fast-rising voltage pulse was investigated for surge protection applications. The effects of temperature and pressure on the arc and the electrical conduction were analyzed by the characteristic changes in voltage waveforms triggered by a fast-rising high voltage pulse. In addition to the gap size, experimental results show that competing mechanisms among arc conduction, conduction through the varistor granule network, thermionic emission from Joule heating at granule-to-granule contact points, and the magnitude of the switching voltage dictate the maximum surge protection voltage for the filled air gap. Experimental evidence indicated that accumulated degradation was created at small contact points between varistor granules by repetitive assaults from longer duration, high voltage pulses. The uniqueness of using varistor over other dielectric granules in an air gap for surge protection is identified and discussed.

36 MATERIALS SCIENCE↗

Efficiency and Forward Voltage of Blue and Green Lateral LEDs with V-shaped Defects and Random Alloy Fluctuation in Quantum Wells

For nitride-based blue and green light-emitting diodes (LEDs), the forward voltage V for is larger than expected, especially for green LEDs. This is mainly due to the large barriers to vertical carrier transport caused by the total polarization discontinuity at multiple quantum well and quantum barrier interfaces. The natural random alloy fluctuation in quantum wells has proven to be an important factor reducing V for . However, this does not suffice in the case of green LEDs because of their larger polarization-induced barrier. V-shaped defects (V-defects) have been proposed as another key factor in reducing V for to allow lateral injection into multiple quantum wells, thus bypassing the multiple energy barriers incurred by vertical transport. In this paper, to model carrier transport in the whole LED, we consider both random-alloy and V-defect effects. A fully two-dimensional drift-diffusion charge-control solver is used to model both effects. The results indicate that the turn-on voltages for blue and green LEDs are both affected by random alloy fluctuations and the V-defect density. For green LEDs, V for decreases more due to V-defects, where the smaller polarization barrier at the V-defect sidewall is the major path for lateral carrier injection. Then, we discuss how the V-defect density and size affects the results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Silicon Detectors For Helium Liquid And Vapor

Simple electrical-resistance devices made of silicon indicate whether helium liquid or helium vapor present. Devices designed primarily for use in outer space, were tested and found to operate in normal Earth gravity. Silicon cubes supported by stainless-steel wires and strips. Voltage across each cube at fixed current indicates whether immersed in helium liquid or vapor. Liquid cools more than vapor does, resulting in greater electrical resistance. Such helium-liquid/vapor detectors incorporated into ducts or containers of laboratory equipment, and used to infer locations of liquid/vapor interfaces in order to measure quantities of liquid and vapor or to control refill operations.

Di Pirro, M. J.↗

Fundamental investigation of unipolar and RF corona in atmospheric air

Here, unipolar (DC) and radio frequency (RF) corona at 3.3 MHz is studied at centimeter-sized gaps in a needle-plane geometry in atmospheric air at room temperature. Positive and negative corona using pure tungsten electrodes with varying tip angles revealed a lower onset voltage for the needle with the smaller included angle. The RF corona onset voltage and corresponding time delay were measured for a series of needles composed of pure tungsten or 2% lanthanated tungsten. The corona onset, established when the first instance of UV photon emission is detected via photomultiplier tube, occurred primarily during the negative half cycle of the applied RF voltage for pure tungsten needles. In contrast, with lanthanated tungsten needles, such preference was not observed. No distinguishable difference in onset voltage between pure tungsten and lanthanated tungsten was found, indicating that adding a small amount of lanthanum to tungsten has a negligible impact on the onset voltage at 3.3 MHz frequencies for electrodes at room temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current leakage for low altitude satellites - Modeling applications

To simulate the behavior of a high voltage solar cell array in the ionospheric plasma environment, the large (90 ft x 55 ft diameter) vacuum chamber was used to measure the high-voltage plasma interactions of a 3 ft x 30 ft conductive panel. The chamber was filled with Nitrogen and Argon plasma at electron densities of up to 1,000,000 per cu cm. Measurements of current flow to the plasma were made in three configurations: (a) with one end of the panel grounded, (b) with the whole panel floating while a high bias was applied between the ends of the panel, and (c) with the whole panel at high negative voltage with respect to the chamber walls. The results indicate that a simple model with a constant panel conductivity and plasma resistance can adequately describe the voltage distribution along the panel and the plasma current flow. As expected, when a high potential difference is applied to the panel ends more than 95% of the panel floats negative with respect to the plasma.

Konradi, A.↗

Design of a fast computer-based partial discharge diagnostic system

Partial discharges cause progressive deterioration of insulating materials working in high voltage conditions and may lead ultimately to insulator failure. Experimental findings indicate that deterioration increases with the number of discharges and is consequently proportional to the magnitude and frequency of the applied voltage. In order to obtain a better understanding of the mechanisms of deterioration produced by partial discharges, instrumentation capable of individual pulse resolution is required. A new computer-based partial discharge detection system was designed and constructed to conduct long duration tests on sample capacitors. This system is capable of recording large number of pulses without dead time and producing valuable information related to amplitude, polarity, and charge content of the discharges. The operation of the system is automatic and no human supervision is required during the testing stage. Ceramic capacitors were tested at high voltage in long duration tests. The obtained results indicated that the charge content of partial discharges shift towards high levels of charge as the level of deterioration in the capacitor increases.

Oliva, Jose R.↗

Impact of Lithium‐Free Borate Additives on the Cycle Life and Calendar Aging of Silicon‐Based Lithium‐Ion Batteries

Silicon-anode lithium-ion batteries (LIBs) suffer from limited cycle life and poor calendar life, constraining their large-scale commercialization. Integrating additives into electrolytes is a simple and cost-effective strategy to improve these aspects. The effects of lithium-free boron-based additives on cycling and calendar performance of high-loading Si-anode LIBs remain largely unexplored. In this work, the influence of five Li-free borate additives, each with distinct molecular structures and elemental compositions, is systematically investigated. All additives enhance cycle life to varying extents. Notably, the addition of 1 v/v% tri(2,2,2-trifluoroethyl) borate to the baseline electrolyte nearly doubles the cycle life at 50% state of health. This enhancement is attributed to three key factors. Specifically, borate additives 1) improve electrochemical activity, 2) act as anion receptors that interact with [PF6]- anions and carbonate solvents to reduce electrolyte decomposition, and 3) promote the formation of a stable and polymeric solid electrolyte interphase layer. Furthermore, these additives exhibited negligible impact in mitigating leakage current during a 180 h voltage-hold calendar-aging test, indicating their limited effect in calendar life. These findings provide insight into the role of Li-free borate additives in improving cycle life while addressing the knowledge gap regarding their influence on calendar aging.

Li, Defu↗

Ohmic contact formation at the Au/Sr 3 Ir 2 O 7 interface

Here, using X-ray photoelectron spectroscopy (XPS), we show that Au forms an Ohmic contact with the surface of the narrow-bandgap Mott insulator Sr 3 Ir 2 O 7 thin films. XPS reveals no significant binding energy shift with increasing Au overlayer thickness on epitaxial Sr 3 Ir 2 O 7 (001) thin films, consistent with the linear current-voltage (I-V) behavior and indicative of negligible band bending. The absence of Schottky barrier formation at the Au/Sr 3 Ir 2 O 7 interface corroborates the metallic surface character of the Sr 3 Ir 2 O 7 thin film, as observed in angle-resolved photoemission spectroscopy (ARPES) studies, suggesting that the interface behaves effectively as a metal-on-metal contact. Furthermore, XPS points to the presence of distinct surface/interface and bulk electronic states for Sr 3 Ir 2 O 7 . This study provides critical material information for designing iridate-based electronic devices.

36 MATERIALS SCIENCE↗

Oxygen redox activities governing high-voltage charging reversibility of Ni-rich layered cathodes

A schematic illustration indicative of the improved structural reversibility through stabilizing oxidized oxygen by Al doping. The chemical reactions and phase transitions at high voltages are generally considered to determine the electrochemical properties of high-voltage layered cathodes such as Ni-rich rhombohedral oxides. Even if significantly higher SOCs (states-of-charge) are utilized above the capability of transition metal redox (primarily Ni and Co), the effect of oxygen redox on Ni-rich rhombohedral oxides still looks mysterious thereby necessitating research that can clarify the relationship between redox reactions and phase transitions. Here, we performed a comprehensive and comparative study of the cationic and anionic redox reactions, as well as the structural evolution of a series of commercial Ni-rich layered oxides with and without Al doping. We combined the results from X-ray spectroscopy, operando electrochemical mass spectrometry, and neutron diffraction with electrochemical properties and thereby revealed the different oxygen redox activities associated with structural and electrochemical degradations. We reveal that Al doping suppresses the irreversible oxygen release but enhances the lattice oxygen oxidization. With this modulated oxygen redox activity, the Ni-rich layered oxides’ notorious H2–H3 structural phase transition becomes highly reversible. Our findings disentangle the different oxygen redox activities during high-voltage cycling and clarify the role of dopants in the Ni-rich layered oxides in terms of structural and electrochemical stability, shedding light on the future direction of optimizing layered cathode materials for safer high energy-density secondary batteries.

Lee, Gi-Hyeok↗