Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systems testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Networked HIL Simulation System for Modeling Large-scale Power Systems

This paper presents a network hardware-in-the-loop (HIL) simulation system for modeling large-scale power systems. Researchers have developed many HIL test systems for power systems in recent years. Those test systems can model both microsecond-level dynamic responses of power electronic systems and millisecond-level transients of transmission and distribution grids. By integrating individual HIL test systems into a network of HIL test systems, we can create large-scale power grid digital twins with flexible structures at required modeling resolution that fits for a wide range of system operating conditions. This will not only significantly reduce the need for field tests when developing new technologies but also greatly shorten the model development cycle. In this paper, we present a networked OPAL-RT based HIL test system for developing transmission-distribution coordinative Volt-VAR regulation technologies as an example to illustrate system setups, communication requirements among different HIL test systems, and connection mechanisms. Impacts of communication delays, information exchange cycles, and computing delays are illustrated. Simulation results show that the performance of a networked HIL test system is satisfactory.

digital twin, distribution system, co-simulation, ↗

System and method for testing missile components

A testing system for testing a missile component having a sense axis includes a centrifuge, a support arm, an orientation assembly, and a controller. The centrifuge rotates the orientation assembly about a vertical axis in a substantially horizontal plane. The orientation assembly includes a first motor, a first gimbal, and a gimballed support. The first motor has a first rotatable shaft defining a first gimbal axis. The first gimbal is coupled with the first rotatable shaft to rotate about the first gimbal axis while the centrifuge rotates the orientation assembly about the vertical axis such that missile component is simultaneously rotated about both the vertical axis and the first gimbal axis to simulate a missile launch of the missile component. The gimballed support is coupled with the first gimbal for supporting the missile component such that the sense axis of the missile component is not parallel to the substantially horizontal plane. The orientation assembly may also include a second gimbal that is rotated about a second gimbals axis by a second motor.

Prewitt, Steven Forrest↗

System and method for testing missile components

A testing system for testing a missile component having a sense axis includes a centrifuge, a support arm, an orientation assembly, and a controller. The centrifuge rotates the orientation assembly about a vertical axis in a substantially horizontal plane. The orientation assembly includes a first motor, a first gimbal, and a gimballed support. The first motor has a first rotatable shaft defining a first gimbal axis. The first gimbal is coupled with the first rotatable shaft to rotate about the first gimbal axis while the centrifuge rotates the orientation assembly about the vertical axis such that missile component is simultaneously rotated about both the vertical axis and the first gimbal axis to simulate a missile launch of the missile component. The gimballed support is coupled with the first gimbal for supporting the missile component such that the sense axis of the missile component is not parallel to the substantially horizontal plane. The orientation assembly may also include a second gimbal that is rotated about a second gimbals axis by a second motor.

Prewitt, Steven Forrest↗

Molten salt environment creep testing extensometry system

Disclosed herein are systems, devices and methods for creep testing selected materials within a high-temperature molten salt environment. Exemplary creep testing systems include a load train for holding a test specimen under a load within a heated inert gas vessel. An extensometry system can be included to measure elongation of the test specimen while under load. The extensometry system can include fixed members and axially translating member that move along with the elongation of the test specimen, and the system can include a sensor to measure the relative axial motion between such components to measure elongation of the test specimen over time. The test specimen can include a cylindrical gage portion having an internal void filled with a molten salt during creep testing to simulate the corrosive effect of the molten salt on the specimen material during testing.

Ren, Wenlin↗

Two-terminator RF adapter for background/environment noise measurement

A two-terminator RF adapter for background noise measurement in a test environment comprises a system test port comprising a system test port termination and a system test port connector to connect to a system under test; and a data acquisition port, comprising a data acquisition port termination and a data acquisition port connector to connect to a data acquisition system.

Kolski, Jeffrey↗

SPECTR System Operational Test Report

This report overviews installation of the Small Pressure Cycling Test Rig (SPECTR) and documents the system operational testing performed to demonstrate that it meets the requirements for operations. The system operational testing involved operation of the furnace system to the design conditions and demonstration of the test article gas supply system using a simulated test article. The furnace and test article systems were demonstrated to meet the design requirements for the Next Generation Nuclear Plant. Therefore, the system is deemed acceptable and is ready for actual test article testing.

42 ENGINEERING↗

Packet sniffer node and system including the same to assess wireless communication performance

A wireless system includes a plurality of wireless nodes structured to participate in a system test of the wireless nodes. The system test includes a plurality of test packets. A packet sniffer node includes a wireless receiver, a memory storing a schedule defining transmission and reception of the test packets by the wireless nodes, and a processor cooperating with the wireless receiver and the memory to receive at least some of the test packets responsive to the schedule, and to output data corresponding to the received test packets of the system test. A monitoring computer receives the output data from the processor of the packet sniffer node. Operation of the packet sniffer node, which does not transmit, does interfere with or alter execution of the system test.

Armstrong, Brian S. R.↗

Smart-DS: Synthetic Models for Advanced, Realistic Testing: Distribution Systems and Scenarios

The explosion of new ideas for distributed energy resources and advanced distribution grid algorithms faces a critical challenge: how can one effectively develop and evaluate these breakthrough technologies without an adequate set of power systems network, load, and resource data to test against? Today's open test systems, particularly for distribution systems, are tiny and incomplete; and though with enough effort, obtaining utility data under NDA can overcome scale challenges, the results can't be openly shared, preventing fair comparison. The Smart-DS project-led by NREL in partnership with MIT, Universidad Pontificia Comillas, CYME, and EDD-is working to overcome this gap by generating multiple large-scale, open, synthetic, distribution systems that are realistic but not real. These datasets go beyond a single medium voltage feeder (~1000 customers) to cover entire metropolitan areas and their surrounds with up to hundreds of feeders and millions of customers, complete with low voltage customer connections and high voltage sub-transmission. This scale allows adequate testing and analysis of not just local controls and advanced DERs, but also multiple substation interactions, optimized switching, full-scale distribution-OPF, and more. To accompany these datasets, the project is also building a rich set of scenario generation tools that can be used for distribution and transmission systems alike. This includes automated, spatially aware access to world-class, high-resolution solar, wind, and weather data: forward looking generation mixes: and highly configurable DER, load, climate, outage, control-scheme, and other scenarios. We will also highlight DiTTo, an exciting open-source, multi-way distribution dataset transformation tool for many-to-many format translation with scenario, merge/split, and many other manipulation capabilities.

DERs↗

NREL's Advanced Distribution Management System (ADMS) Test Bed

NREL's advanced distribution management system (ADMS) test bed is a vendor-neutral resource for evaluating existing and future ADMS functionalities in a realistic laboratory setting. The test bed uses Opal-RT's ePHASORsim and eMEGAsim products interfaced with an OpenDSS power system simulation through the HELICS cosimulation platform developed by multiple DOE laboratories; and with power and controller hardware. NREL will present an overview of the test bed and the technologies included within it, and also some examples of how the test bed has been used to address industry challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computational modeling of nanoscale and microscale particle deposition, retention and dosimetry in the mouse respiratory tract

Comparing effects of inhaled particles across rodent test systems and between rodent test systems and humans is a key obstacle to the interpretation of common toxicological test systems for human risk assessment. These comparisons, correlation with effects and prediction of effects, are best conducted using measures of tissue dose in the respiratory tract. Differences in lung geometry, physiology and the characteristics of ventilation can give rise to differences in the regional deposition of particles in the lung in these species. Differences in regional lung tissue doses cannot currently be measured experimentally. Regional lung tissue dosimetry can however be predicted using models developed for rats, monkeys, and humans. A computational model of particle respiratory tract deposition and clearance was developed for BALB/c and B6C3F1 mice, creating a cross-species suite of available models for particle dosimetry in the lung. Airflow and particle transport equations were solved throughout the respiratory tract of these mice strains to obtain temporal and spatial concentration of inhaled particles from which deposition fractions were determined. Particle inhalability (Inhalable fraction, IF) and upper respiratory tract (URT) deposition were directly related to particle diffusive and inertial properties. Measurements of the retained mass at several post-exposure times following exposure to iron oxide nanoparticles, micro- and nanoscale C60 fullerene, and nanoscale silver particles were used to calibrate and verify model predictions of total lung dose. Interstrain (mice) and interspecies (mouse, rat and human) differences in particle inhalability, fractional deposition and tissue dosimetry are described for ultrafine, fine and coarse particles.

Lung deposition, nanosized particles, particle↗

System and method for testing true stress and true strain

A true stress testing system broadly comprising a force input machine, an imaging system, and a computer. The imaging system includes a light source for projecting a light beam at the specimen in a first direction and a camera positioned on an opposite side of the specimen for receiving portions of the light beam not blocked by the specimen such that a shadow image of the specimen is created via the camera. The computer may determine a minimum dimension of the specimen perpendicular to the first direction at a point in time over a plurality of points along the force axis via the shadow image of the specimen such that the processor accounts for changes in position of the minimum dimension along the specimen. A true stress of the specimen may then be determined according to the minimum dimension of the specimen perpendicular to the first direction at the point in time.

42 ENGINEERING↗

SDOE 650: System Architecture and Design

The proposed system is a test system that verifies the cables functionality in the expected environments defined in the ES. Verification methods include test, inspect, demonstrate, and analyze. Since we are defining the architecture for a test system we will focus on the customer expectations and requirements that will be satisfied or verified via testing

36 MATERIALS SCIENCE↗

BioID/LID System Cartridge Testing Report

LLNL produced two lots of lyophilized LAMP assay containing cartridges, LNL022818 and LNL071818, for testing on Gen3 BioID systems. Thirty-nine cartridges were tested for lot LNL022818. All thirty-nine cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Five different templates were tested on these 39 cartridges. The BioID system detected 79.1% true positives and 9.3% false positives along with 98.9% true negatives and 2.9% false negatives for cartridge lot LNL022818. Thirty cartridges were tested for lot LNL071818. It was noted early that due to a manufacturing issue with the cartridges related to incomplete sonic welding of the cartridge, a large fraction of lot LNL071818 cartridges leaked. Insufficient funds were available to replace this lot of cartridges. Twenty three of 30 cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Four different templates were tested on these 30 cartridges. The BioID system detected 77% true positives and 23% false positives along with 96.9% true negatives and 3.1% false negatives for cartridge lot LNL071818. For all tested cartridges using DNA template, DNA was added at a final concentration of 25 pg/ul. All reactions contained positive control DNA at 2.5 pg/ul.

42 ENGINEERING↗

Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-incomehomes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Technical Report for CENTRIA's EnergyPeak Building Integrated Photovoltaics ( BIPV ) for Standing Seam Metal Roofing Project (DE-FG36-08GO88131)

Architects have said they will adopt Solar Roofs when they are integrated into roofing systems, building design, plans and specifications, and bidding procedures . Standing Seam Metal Roof manufacturers will answer these architects needs if someone will establish standards, pre-design systems, write specifications, tests systems, meet codes, etc. Energypeak was developed to provide the above so Architects can specify BIPV Standing Seam Roof Systems and Manufacturers can brand, market, sell, manufacture and deliver these systems. EnergyPeak took on the challenge to design BIPV modules using current PV technology, design electrical components, develop wire management systems, test, meet codes, write cad drawings and specifications, commercialize and deliver complete standards to the Industry.

14 SOLAR ENERGY↗