Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spallation source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

HighNESS conceptual design report: Volume I

The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world’s most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron source located below the spallation target. Compared to the first source, designed for high cold and thermal brightness, the new source has been optimized to deliver higher intensity, and a shift to longer wavelengths in the spectral regions of cold (CN, 2–20 Å), very cold (VCN, 10–120 Å), and ultracold (UCN, >500 Å) neutrons. The second source comprises a large liquid deuterium moderator designed to produce CN and support secondary VCN and UCN sources. Various options have been explored in the proposed designs, aiming for world-leading performance in neutronics. These designs will enable the development of several new instrument concepts and facilitate the implementation of a high-sensitivity neutron-antineutron oscillation experiment (NNBAR). This document serves as the Conceptual Design Report for the HighNESS project, representing its final deliverable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shielding development for the spallation neutron source VENUS instrument

VENUS is a neutron imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold energies, and will include enhanced contrast mechanisms. It will offer novel energy-selective imaging techniques directly connecting complex engineering materials and systems’ structures, properties, and functions to reveal practical and fundamental answers about their real-world performance. Here, the instrument will be built at SNS beamline 10, facing the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beamline and instrument cave shielding. Final analyses were performed to evaluate the thickness and composition of shielding materials for the instrument cave and beamline to meet radiation safety criteria for the instrument to start up in 2024 after completing the SNS proton power upgrade.

43 PARTICLE ACCELERATORS↗

Operational characteristics of the J-PARC cryogenic hydrogen system for a spallation neutron source

The J-PARC cryogenic hydrogen system provides supercritical hydrogen with the para-hydrogen concentration of more than 99 % and the temperature of less than 20 K to three moderators so as to provide cold pulsed neutron beams of a higher neutronic performance. Furthermore, the temperature fluctuation of the feed hydrogen stream is required to be within ± 0.25 K. A stable 300-kW proton beam operation has been carried out since November 2012. The para-hydrogen concentrations were measured during the cool-down process. It is confirmed that para-hydrogen always exists in the equilibrium concentration because of the installation of an ortho-para hydrogen convertor. Propagation characteristics of temperature fluctuation were measured by temporarily changing the heater power under off-beam condition to clarify the effects of a heater control for thermal compensation on the feed temperature fluctuation. The experimental data gave an allowable temperature fluctuation of ± 1.05 K. It is clarified through a 286-kW and a 524-kW proton beam operations that the heater control would be applicable for the 1-MW proton beam operation by extrapolating from the experimental data.

07 ISOTOPE AND RADIATION SOURCES↗

Ewald: an extended wide-angle Laue diffractometer for the second target station of the Spallation Neutron Source

Visualizing hydrogen atoms in biological materials is one of the biggest remaining challenges in biophysical analysis. While X-ray techniques have unrivaled capacity for high-throughput structure determination, neutron diffraction is uniquely sensitive to hydrogen atom positions in crystals of biological materials and can provide a more complete picture of the atomic and electronic structures of biological macromolecules. This information can be essential in providing predictive understanding and engineering control of key biological processes, for example, in catalysis, ligand binding and light harvesting, and to guide bioengineering of enzymes and drug design. One very common and large capability gap for all neutron atomic resolution single-crystal diffractometers is the weak flux of available neutron beams, which results in limited signal-to-noise ratios giving a requirement for sample volumes of at least 0.1 mm 3 . The ability to operate on crystals an order of magnitude smaller (0.01 mm 3 ) will open up new and more complex systems to studies with neutrons which will help in our understanding of enzyme mechanisms and enable us to improve drugs against multi resistant bacteria. With this is mind, an extended wide-angle Laue diffractometer, `Ewald', has been designed, which can collect data using crystal volumes below 0.01 mm 3 .

36 MATERIALS SCIENCE↗

Updates on the Progress of the Alternate Topology Modulator (AT-HVCM) to support the Proton Power Upgrade (PPU) at the Spallation Neutron Source

The AT-HVCM, achieved by series-stacking the dual-function resonant filter capacitors following each rectification stage, is the baseline design for the PPU project at the SNS [1]. The project requires three AT-HVCM modulators to power 28 additional 700kW klystrons and associated high beta cavities to accelerate 38mA of beam current to 1.3GeV. Each modulator produces an 82 kV, 120A output pulse of 1.35ms duration at a 60Hz repetition rate. The AT design approach improves upon the existing HVCM topology, reducing stresses on the H bridge IGBTs using zero voltage (ZVS) and current switching (ZCS) techniques and on the resonant filter capacitors by limiting voltage reversal. This paper reviews the prototype development progress, currently focused on evaluating system reliability, and discusses some design techniques to achieve the modulator performance requirements.

Solley, Dennis J.↗

Machine learning at the Spallation Neutron Source accelerator and target

We describe the ongoing efforts to apply Machine Learning techniques to improve the performance of our accelerator and target. Specially, we are looking to minimize halo beam losses in the absence of a proper physics model, automatically detect and log anomalies in the target support systems such as cooling, and detect and prevent errant beam pulses in the linac. We also describe the infrastructure we use to acquire and stream data to the GPU cluster for training, our code development cycle, and edge computing for model inference. To minimize halo beam losses, we use a Reinforcement Learning technique tested on a virtual accelerator. The target anomaly detection is trained on archived data using incomplete physics models and is made part of the existing target reporting system. The errant beam prevention analyzes beam current and beam phase waveforms as well as accelerator configuration data to predict errant pulses. We also develop continual learning to adapt to changes in the accelerator.

Accelerator Physics↗