Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “partial discharges”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

High-voltage spark carbon-fiber sticky-tape data analyzer

An efficient method for detecting carbon fibers collected on a stick tape monitor was developed. The fibers were released from a simulated crash fire situation containing carbon fiber composite material. The method utilized the ability of the fiber to initiate a spark across a set of alternately biased high voltage electrodes to electronically count the number of fiber fragments collected on the tape. It was found that the spark, which contains high energy and is of very short duration, is capable of partially damaging or consuming the fiber fragments. It also creates a mechanical disturbance which ejects the fiber from the grid. Both characteristics were helpful in establishing a single discharge pulse for each fiber segment.

Yang, L. C.↗

Upset susceptibility study employing circuit analysis and digital simulation

This paper describes an approach to predicting the susceptibility of digital systems to signal disturbances. Electrical disturbances on a digital system's input and output lines can be induced by activities and conditions including static electricity, lightning discharge, Electromagnetic Interference (EMI) and Electromagnetic Pulsation (EMP). The electrical signal disturbances employed for the susceptibility study were limited to nondestructive levels, i.e., the system does not sustain partial or total physical damage and reset and/or reload will bring the system to an operational status. The front-end transition from the electrical disturbances to the equivalent digital signals was accomplished by computer-aided circuit analysis. The Super-Sceptre (system for circuit evaluation of transient radiation effects) Program was used. Gate models were developed according to manufacturers' performance specifications and parameters resulting from construction processes characteristic of the technology. Digital simulation at the gate and functional level was employed to determine the impact of the abnormal signals on system performance and to study the propagation characteristics of these signals through the system architecture. Example results are included for an Intel 8080 processor configuration.

Carreno, V. A.↗

Upset susceptibility study employing circuit analysis and digital simulation

An approach to predict the susceptibility of digital systems to signal disturbances is described. Electrical disturbances on a digital system's input and output lines can be induced by activities and conditions including static electricity, lightning discharge, electromagnetic interference (EMI), and electromagnetic pulsation (EMP). The electrical signal disturbances employed for the susceptibility study were limited to nondestructive levels, i.e., the system does not sustain partial or total physical damage and reset and/or reload brings the system to an operational status. The front-end transition from the electrical disturbances to the equivalent digital signals was accomplished by computer-aided circuit analysis. The super-sceptre (system for circuit evaluation of transient radiation effects) programs was used. Gate models were developed according to manufacturers' performance specifications and parameters resulting from construction processes characteristic of the technology. Digital simulation at the gate and functional level was employed to determine the impact of the abnormal signals on system performance and to study the propagation characteristics of these signals through the system architecture. Example results are included for an Intel 8080 processor configuration.

Carreno, V. A.↗

Modeling and simulation of spacecraft power systems

EASY5 modeling of a complete spacecraft power processing system is presented. Component models are developed, and several system models including a solar array switching system, a partially-shunted solar array system and COBE system are simulated. The power system's modes of operation, such as shunt mode, battery-charge mode, and battery-discharge mode, are simulated for a complete orbit cycle.

Lee, J. R.↗

Electric charge build-up and dissipation at pulsed streamer corona by EFISH and probe measurements

The aim of this work is to study the dynamics of volumetric electric charge deposited by a single pin electrode streamer corona in atmospheric air at ambient conditions. Recent studies show that, at pulse-periodic operation, electric charge remains in surrounding air after the first discharge. This residual charge significantly impacts the electric field distribution and morphology of discharges at subsequent pulses. In this study, the residual electrical potential/field was measured during and after dissipation of a pulsed 80kV streamer corona of alternating polarity. This was accomplished using electrostatic probes and the EFISH method (Electric Field Induced Second Harmonic generation). The residual volumetric charge of a positive pulse polarity streamer corona occupies a zone up to 80mm from the electrode. The subsequent application of a negative polarity pulse leads to partial neutralization of the previous charge and the generation of a region with a high-amplitude electric field. Here, the propagation of following positive polarity pulses is limited by the residual positive volumetric charge. The EFISH method reveals the magnitude of the electric field at discharge propagation and electrostatic probes inform the polarity. Intensified imaging acquisition was used to evaluate the spatial distribution and dynamics of corona discharge during the alternating polarity waveform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probabilistic design analysis using Composite Loads Spectra (CLS) coupled with Probabilistic Structural Analysis Methodologies (PSAM)

Composite loads spectra (CLS) were applied to generate probabilistic loads for use in the PSAM nonlinear evaluation of stochastic structures under stress (NESSUS) finite element code. The CLS approach allows for quantifying loads as mean values and distributions around a central value rather than maximum or enveloped values typically used in deterministic analysis. NESSUS uses these loads to determine mean and perturbation responses. These results are probabilistically evaluated with the distributional information from CLS using a fast probabilistic integration (FPI) technique to define response distributions. The main example discussed describes a method of obtaining load descriptions and stress response of the second-stage turbine blade of the Space Shuttle Main Engine (SSME) high-pressure fuel turbopump (HPFTP). Additional information is presented on the on-going analysis of the high pressure oxidizer turbopump discharge duct (HPOTP) where probabilistic dynamic loads have been generated and are in the process of being used for dynamic analysis. Example comparisons of load analysis and engine data are furnished for partial verification and/or justification for the methodology.

Newell, J. F.↗

The characteristics and limitations of the MPS/MMS battery charging system

A series of tests was conducted on two 12 ampere hour nickel cadmium batteries under a simulated cycle regime using the multiple voltage versus temperature levels designed into the modular power system (MPS). These tests included: battery recharge as a function of voltage control level; temperature imbalance between two parallel batteries; a shorted or partially shorted cell in one of the two parallel batteries; impedance imbalance of one of the parallel battery circuits; and disabling and enabling one of the batteries from the bus at various charge and discharge states. The results demonstrate that the eight commandable voltage versus temperature levels designed into the MPS provide a very flexible system that not only can accommodate a wide range of normal power system operation, but also provides a high degree of flexibility in responding to abnormal operating conditions.

Ford, F. E.↗

Partially ionized gas flow and heat transfer in the separation, reattachment, and redevelopment regions downstream of an abrupt circular channel expansion.

Heat transfer and pressure measurements obtained in the separation, reattachment, and redevelopment regions along a tube and nozzle located downstream of an abrupt channel expansion are presented for a very high enthalpy flow of argon. The ionization energy fraction extended up to 0.6 at the tube inlet just downstream of the arc heater. Reattachment resulted from the growth of an instability in the vortex sheet-like shear layer between the central jet that discharged into the tube and the reverse flow along the wall at the lower Reynolds numbers, as indicated by water flow visualization studies which were found to dynamically model the high-temperature gas flow. A reasonably good prediction of the heat transfer in the reattachment region where the highest heat transfer occurred and in the redevelopment region downstream can be made by using existing laminar boundary layer theory for a partially ionized gas. In the experiments as much as 90 per cent of the inlet energy was lost by heat transfer to the tube and the nozzle wall.

Back, L. H.↗

Performance Characterization of InCharge™ ICE-66 V2X Bidirectional DC Fast Charger

Vehicle-to-grid (V2G) technology extends the role of Plug-in Hybrid Vehicle’s (PHEV) and Battery Electric Vehicle’s (BEV) batteries beyond transportation by enabling bidirectional power transfer between the vehicle's onboard energy storage and the utility grid. Modern battery-powered vehicles are equipped with high-capacity battery packs that remain stationary and underutilized for the majority of their operational life. A vehicle used for daily commuting may be parked and connected to charging infrastructure for 18–20 hours per day, representing a significant untapped energy resource. When considered at scale, the aggregated storage capacity of a modest fleet of 10–15 vehicles within a single parking facility can reach the MWh range, sufficient to partially offset peak demand for a mid-size commercial building or contribute meaningful ancillary services to the local grid. The ability to charge during off-peak periods when electricity prices are low and discharge during peak demand when prices are high positions EV batteries as distributed energy arbitrage assets, with the potential to offset vehicle ownership and charging costs. Beyond energy arbitrage, V2G-capable assets can provide ancillary grid services through active and reactive power injections. Active power supports grid frequency regulation, while reactive power supports local voltage regulation. Together, these capabilities establish V2G as a technically promising and economically relevant pathway toward greater integration of battery-powered vehicles into the broader energy system.

33 ADVANCED PROPULSION SYSTEMS↗

The Role of Atmospheric Rivers on Groundwater: Lessons Learned From an Extreme Wet Year

Abstract In the coastal regions of the western United States, atmospheric rivers (ARs) are associated with the largest precipitation generating storms and contribute up to half of annual precipitation, but the impact of ARs on the integrated hydrologic cycle, specifically on groundwater storage and hydrodynamics, is largely unknown. To better explore the hydrologic behavior of AR versus non‐AR event precipitation, we present a novel combination of two water tracking methods (one in the atmosphere and one in the subsurface) to explicitly track the full lifecycle of water parcels generated by ARs. Simulations of northern California's Cosumnes River watershed during the record wet 2017 water year are performed via the coupling of a high‐resolution regional climate model and a land surface‐groundwater model accounting for lateral groundwater flow. Despite ARs contributing more precipitation than non‐AR storms, we find less AR water is preferentially stored in aquifers by year end. Fractionally, ARs result in 300% less snow derived groundwater‐recharged compared to non‐AR precipitation. Rain‐on‐snow (RoS) plays an important role in AR‐driven discharge, where over 50% of total discharge from ARs snow is from RoS events. Finally, despite record‐breaking annual precipitation, simulated groundwater depletion occurs by year end due to estimates of groundwater pumping activities. The results from these simulations serve as a partial analogue of future hydrologic conditions where ARs are expected to intensify and provide a greater fraction of annual precipitation due to climate change.

54 ENVIRONMENTAL SCIENCES↗

Probing Sensitivity of Discharge Characteristics to Model Selection using Uncertainty Quantification in an aprotic Li-Oxygen Battery

Currently, there are several models in the literature, such as kinetic models, microstructural models, and mass transport models that describe a Li-air battery's discharge behavior. Many of these models are calibrated and tested at low current densities and cannot be easily transferred to high current densities. Even at low current densities, there is no quantitative method for a researcher to choose a reaction kinetic model such as classical Butler-Volmer and its derivatives, and modified Marcus-Hush-Chidsey, a resistance model for lithium peroxide such as electron transport via tunneling or linear resistivity, a surface coverage model (lithium peroxide growth) such as partial coverage or full coverage, and mass transport model (discussed in Ref. [1]). Also, it is time-consuming to test different models at high current density (1C) due to a lack of well-tested models and well-calibrated model parameters. For this presentation, we will develop an analytical model, which acts as a surrogate model for a sophisticated finite element model to predict discharge time and discharge voltage. Next, we use an uncertainty quantifying technique called reduced-order stochastic optimization [2, 3] to determine the uncertainty in model parameters for rate kinetics, lithium peroxide resistivity, and parasitic resistance. Finally, a finite element simulation is performed to determine the error introduced by the surrogate model and its influence on the uncertainty in the model parameters.

M Mehta↗

Cadmium poisoning of oxygen reduction on platinum electrode in potassium hydroxide

Experiment with a rotating disk and ring apparatus showed no poisoning by cadmium in 8.5 M KOH, alone or with Cl(-) or CO3(=). Poisoning does not occur either in 0.1 M KOH supernatant at CdO, but a partially reversible poisoning results from .0001 M CdCl2 and traces of fatty acid are present. Evidence indicates that the catastrophic poisoning affects the four-electron O2 reduction more than it does the one-electron H3O(+) discharge.

Miller, R. O.↗

Predicting EBW detonator failure using DSC data

Exploding bridgewire detonators (EBWs) containing pentaerythritol tetranitrate (PETN) exposed to high temperatures may not function following discharge of the design electrical firing signal from a charged capacitor. Knowing functionality of these arbitrarily facing EBWs is crucial when making safety assessments of detonators in accidental fires. Orientation effects are only significant when the PETN is partially melted. Here, the melting temperature can be measured with a differential scanning calorimeter. Nonmelting EBWs will be fully functional provided the detonator never exceeds 406 K (133 °C) for at least 1 h. Conversely, EBWs will not be functional once the average input pellet temperature exceeds 414 K (141 °C) for a least 1 min which is long enough to cause the PETN input pellet to completely melt. Functionality of the EBWs at temperatures between 406 and 414 K will depend on orientation and can be predicted using a stratification model for downward facing detonators but is more complex for arbitrary orientations. A conservative rule of thumb would be to assume that the EBWs are fully functional unless the PETN input pellet has completely melted.

42 ENGINEERING↗

Partially Ionized Plasma Physics and Technological Applications

Partially ionized plasma physics has attracted increased attention recently due to numerous technological applications made possible by the increased sophistication of computer modelling, the depth of the theoretical analysis, and the technological applications to a vast field of manufacturing for computer components. Partially ionized plasma is characterized by a significant presence of neutral particles in contrast to the fully ionized plasma. The theoretical analysis is based upon solutions of the kinetic Boltzmann equation, yielding the non-Maxwellian electron energy distribution function (EEDF), thereby emphasizing the difference with a fully ionized plasma. The impact of the effect on discharges in inert and molecular gases is described in detail, yielding the complex nonlinear phenomena resulting in plasma selforganization. A few examples of such phenomena are given, including the non-monotonic EEDFs in the discharge afterglow in a mixture of argon with the molecular gas NF3; the explosive generation of cold electron populations in capacitive discharges, hysteresis of EEDF in inductively coupled plasmas. Recently, highly advanced computer codes were developed in order to address the outstanding challenges in plasma technology. These developments are briefly described in general terms.

non-Maxwellian electron energy distribution functi↗

Characterization of DBD Plasma Actuators Performance without External Flow : Thrust-Voltage Quadratic Relationship in Logarithmic Space for Sinusoidal Excitation - Part I

We present results of thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators. We have used a test setup, measurement, and data processing methodology that we developed in prior work. The tests were conducted with High Density Polyethylene (HDPE) actuators of three thicknesses. The applied voltage driving the actuators was a pure sinusoidal waveform. The test setup was suspended actuators with a partial liquid interface. The tests were conducted at low ambient humidity. The thrust was measured with an analytical balance and the results were corrected for anti-thrust to isolate the plasma generated thrust. Applying this approach resulted in smooth and repeatable data. It also enabled curve fitting that yielded quadratic relations between the plasma thrust and voltage in log-log space at constant frequencies. The results contrast power law relationships developed in literature that appear to be a rough approximation over a limited voltage range.

Dielectric Barrier Discharge↗

Theoretical investigations of plasma processes in the ion bombardment thruster

A physical model for a thruster discharge was developed, consisting of a spatially diverging plasma sustained electrically between a small ring cathode and a larger ring anode in a cylindrical chamber with an axial magnetic field. The associated boundary-value problem for the coupled partial differential equations with mixed boundary conditions, which describe the electric potential and the plasma velocity fields, was solved in closed form. By means of quantum-mechanical perturbation theory, a formula for the number S(E) of atoms sputtered on the average by an ion of energy E was derived from first principles. The boundary-value problem describing the diffusion of the sputtered atoms through the surrounding rarefied electron-ion plasma to the system surfaces of ion propulsion systems was formulated and treated analytically. It is shown that outer boundary-value problems of this type lead to a complex integral equation, which requires numerical resolution.

Wilhelm, H. E.↗

JPS heater and sensor lightning qualification

Simulated lightning strike testing of the Redesigned Solid Rocket Motor (RSRM) field joint protection system heater assembly was performed at Thiokol Corp., Wendover Lightning Facility. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of heater cable transients on cables within the systems tunnel. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by transients from all cables external to the systems tunnel, was 92 amperes. The maximum open-circuit voltage coupled was 316 volts. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by heater power cable transients only, was 2.7 amperes; the maximum open-circuit voltage coupled was 39 volts. All heater power cable induced coupling was due to simulated lightning discharges only, no heater operating power was applied during the test. The results showed that, for a worst-case lightning discharge, the heater power cable is responsible for a 3.9 decibel increase in voltage coupling to operational flight cables within the systems tunnel. Testing also showed that current and voltage levels coupled onto cables within the systems tunnel are partially dependant on the relative locations of the cables within the systems tunnel.

Cook, M.↗

Tunning the linkage of structure units to enable stable spinel-based cathode in the wide potential window

The low practical capacity (<140 mA h g –1 ) of spinel phase LiMn 2–x Ni x O 4 (0 < x < 1) excludes it from high energy density lithium ion batteries (LIBs) for powering electric vehicles. Extending the operating potential window from 3.0 to 4.8 V to 2.0–4.8 V can double the capacity, but result in fast capacity decay due to the drastic cubic-tetragonal phase transition below 3.0 V, induced by serious Jahn-Teller (J-T) distortion of structure units (Mn 3+ )O 6 octahedra. Herein, we propose a novel strategy to suppress J-T distortion by tuning the linkage of structure units MnO 6 octahedra. The original full-vertex-sharing LiO 4 tetrahedra around MnO 6 octahedra in spinel phase are partially replaced by edge-sharing LiO 6 octahedra, which relate Mn-O bonds along the dz 2 direction with those along the d xy plane, thus significantly mitigating J-T distortion and suppressing the phase transition when discharged to 2.0 V. Following this strategy, the prepared spinel-based cathode achieves a high reversible capacity of about 290 mA h g –1 and an energy density up to 957 W h kg –1 with improved cycling stability. Furthermore, this work finds a new opportunity for the traditional spinel cathode towards applications in high energy density LIBs in a low cost and sustainable manner.

25 ENERGY STORAGE↗