Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Analysis of Mauna Kea Imaging of Comet Shoemaker-Levy 9

The aim of this proposal was to analyse a set of charge-coupled device images of the Jupiter-impacting comet D/Shoemaker-Levy 9. The images were obtained primarily using the University of Hawaii 2.2-m telescope and a standardized imaging device, providing an unusually uniform set of data. Additional data included a set of spectra taken in search of gaseous emission from SL9 using the UH 2.2-m and Keck 10-m telescopes.

Jewitt, David↗

Compact Visible And Infrared Spectrometer

New compact spectrometers operate over broad wavelength ranges with moderate spectral resolution. Prototype measures spectral intensity simultaneously at all wavelengths from 3,700 to 11,700 Angstrom, with resolution of 12 Angstrom. Spectrum imaged onto strips on photocathode, then coupled via fiber-optic taper onto charge-coupled-device imager. Suitable for observation of weak phenomena as nocturnal airglow, and for observation of bright auroras and dayglow.

Torr, Marsha R.↗

Critical nematic correlations throughout the superconducting doping range in Bi 2–z Pb z Sr 2–y La y CuO 6+x

Charge modulations have been widely observed in cuprates, suggesting their centrality for understanding the high-T c superconductivity in these materials. However, the dimensionality of these modulations remains controversial, including whether their wavevector is unidirectional or bidirectional, and also whether they extend seamlessly from the surface of the material into the bulk. Material disorder presents severe challenges to understanding the charge modulations through bulk scattering techniques. We use a local technique, scanning tunneling microscopy, to image the static charge modulations on Bi 2–z Pb z Sr 2–y La y CuO 6+x . The ratio of the phase correlation length ξ CDW to the orientation correlation length ξ orient points to unidirectional charge modulations. By computing new critical exponents at free surfaces including that of the pair connectivity correlation function, we show that these locally 1D charge modulations are actually a bulk effect resulting from classical 3D criticality of the random field Ising model throughout the entire superconducting doping range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CCD sensors for spacecraft optical navigation

The optical navigation process uses spaceborne measurements of the apparent direction vector from the spacecraft to a target body, (planet, satellite, star, etc.) to improve estimates of the spacecraft trajectory. Ground-based controllers assimilate the optical measurements, together with spacecraft radio-tracking data and target ephemeris data, to generate a best estimate of the trajectory relative to the target. The present paper deals with a development program supporting the use of (solid state) CCD (Charged Coupled Device) imagers for spacecraft navigation. It is shown that stars can be detected that are two to three magnitudes fainter than with an equivalent vidicon based instrument, that effects of global response nonuniformity and dark current spikes can be essentially eliminated from the data as a result of the reproducibility of both effects, and that charge trailing during readout of star image data can lead to position measurement errors.

Eisenman, A. R.↗

Starburst outflows from nearby galaxies

Starburst outflows from NGC 5461, 1569 and M82 are discussed. The Sc I galaxy, M101, is reknowned for the kpc-size superassociations of star clusters and HII regions that dominate its spiral arms. NGC 5461 is one of the brightest of these superassociations, rivaling the Large Magellanic Cloud in H alpha luminosity. The NGC 5461 superassociation is dominated by a single unresolved HII region of outstanding luminosity (approx. 1000 Orion nebulae). Detailed examination of corresponding continuum images indicates that only the southern plume has any sort of stellar counterpart. The other plumes are clearly diffuse with no underlying hot stars. An image of NGC 1569 is discussed. Besides showing the peculiar arm noted by Zwicky (1971) and the filamentary extensions to the North and South (as noted by Hodge 1974), this image also reveals two arc-like features of diffuse ionized gas to the South. Both arcs are concentric with the bright center of the galaxy - where the super star clusters, A and B are located. The inner arc (Arc 1) appears to follow the same curve as the SW arm thus suggesting that the two features represent limb-brightened fragments of vast superbubble that was blown out by a central starburst sometime in the past. As the classic starburst galaxy, M82 displays all the luminous hallmarks of intense high-mass star formation and outflow activity. The diffuse H alpha and x ray emitting gas along the minor axis provides especially good evidence for a bipolar outflow of hot gas which is shock heating the swept-up interstellar medium (ISM) to temperatures of approx. 10(exp 4) K. An image shows the H alpha emission within the disk and along the minor axis. Another image shows the same field in the light of near-infrared. Both figures are based on charge coupled device images taken with the McGraw-Hill 1.3 m telescope (Waller 1989). The longer wavelength emission clearly shows a more extended morphology along the major axis. The morphological discrepancy is most likely due to the greater obscuration by dust suffered by the H alpha photons. A third image shows the map of visual extinction that researchers derive from a pixel-by-pixel comparison of the (SIII) and H alpha fluxes. The greatest extinctions are evident along an arc that includes two especially obscured regions on opposite sides of the bursting nucleus.

Waller, William H.↗

Absolute Position Encoders With Vertical Image Binning

Improved optoelectronic patternrecognition encoders that measure rotary and linear 1-dimensional positions at conversion rates (numbers of readings per unit time) exceeding 20 kHz have been invented. Heretofore, optoelectronic pattern-recognition absoluteposition encoders have been limited to conversion rates <15 Hz -- too low for emerging industrial applications in which conversion rates ranging from 1 kHz to as much as 100 kHz are required. The high conversion rates of the improved encoders are made possible, in part, by use of vertically compressible or binnable (as described below) scale patterns in combination with modified readout sequences of the image sensors [charge-coupled devices (CCDs)] used to read the scale patterns. The modified readout sequences and the processing of the images thus read out are amenable to implementation by use of modern, high-speed, ultra-compact microprocessors and digital signal processors or field-programmable gate arrays. This combination of improvements makes it possible to greatly increase conversion rates through substantial reductions in all three components of conversion time: exposure time, image-readout time, and image-processing time.

Leviton, Douglas B.↗

Characterization of Advanced Imaging Systems for High-Resolution and Event-Mode Detection

Post-irradiation examination (PIE) is a continually growing field critical to the development of improved nuclear fuels. To characterize these materials, neutron imaging systems are employed and outfitted with, typically, CMOS or CCD cameras - complementary metal oxide semiconductor sensors and charge-couple devices. Imaging systems are a team-effort between the camera, scintillating materials, and object of interest, as a result of neutrons' inherent need to be converted to a detectable signal. High resolution imaging, flash radiography imaging, and event-mode detection systems are three systems undergoing development, construction, and characterization for improved spatial resolution and time-of-flight detection for PIE efforts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Test results on intensified charge coupled devices

CCD imaging arrays were evaluated for a photon counting astronomical sensor. Results show noise corresponding to less than 100 rms electrons and gains of approximately 1000 at 10kV accelerating voltage (greater than 5000 at 25kV). Measured charge transfer efficiencies are in excess of 0.9999, signal saturation levels are as high as 990000 electrons per pixel and peak quantum efficiencies are greater than 75%. Successful proximity focussed intensified charge coupled devices (ICCD) have been fabricated, although problems still exist with contamination and possible structural failures in the CCD's during tube manufacture.

Williams, J. T.↗

Modeling and Measuring Charge-Sharing in Hard X-ray Imagers Using HEXITEC CdTe Detectors

The Rutherford Appleton Laboratory's HEXITEC ASIC has been designed to provide fine pixelated X-ray spectroscopic imaging in combination with a CdTe or CZT detector layer. Although HEXITEC's small pixels enable higher spatial resolution as well as higher spectral resolution via the small-pixel effect, they also increase the probability of charge sharing, a process which degrades spectral performance by dividing the charge induced by a single photon among multiple pixels. In this paper, we investigate the effect of this process on a continuum X-ray spectrum below the Cd and Te fluorescence energies (23 keV). This is done by comparing laboratory measurements with simulations performed with a custom designed model of the HEXITEC ASIC. We find that the simulations closely match the observations implying that we have an adequate understanding of both charge sharing and the HEXITEC ASIC itself. These results can be used to predict the distortion of a spectrum measured with HEXITEC and will help determine to what extent it can be corrected. They also show that models like this one are important tools in developing and interpreting observations from ASICs like HEXITEC.

Ryan, Daniel F.↗

An abuttable CCD imager for visible and X-ray focal plane arrays

A frame-transfer silicon charge-coupled-device (CCD) imager has been developed that can be closely abutted to other imagers on three sides of the imaging array. It is intended for use in multichip arrays. The device has 420 x 420 pixels in the imaging and frame-store regions and is constructed using a three-phase triple-polysilicon process. Particular emphasis has been placed on achieving low-noise charge detection for low-light-level imaging in the visible and maximum energy resolution for X-ray spectroscopic applications. Noise levels of 6 electrons at 1-MHz and less than 3 electrons at 100-kHz data rates have been achieved. Imagers have been fabricated on 1000-Ohm-cm material to maximize quantum efficiency and minimize split events in the soft X-ray regime.

Burke, Barry E.↗

Improved imaging using Mn He- α x rays at OMEGA EP

In this paper, we report on a crystal based x-ray imaging system fielded at the OMEGA EP laser facility. This new system has a pointing accuracy of +/100 μm, a temporal resolution down to 100 ps (depending on backlighter characteristics), variable magnification, and a spatial resolution of 21.9 µm at the object plane at a magnification of 15×. The system is designed to use a crystal along the crystal plane that satisfies the Bragg condition for the x ray of interest. The thin crystal is then bent into a spherical geometry and attached to a glass backing substrate to hold it in the diagnostic, and the x rays are imaged onto a charge coupled device. We report on data acquired with the new Los Alamos National Laboratory supplied spherical quartz crystal to image the Mn He-α 6.15 keV line emission.

Fiedler Kawaguchi, C. (ORCID:0000000175522370)↗

Charge-coupled device data processor for an airborne imaging radar system

Processing of raw analog echo data from synthetic aperture radar receiver into images on board an airborne radar platform is discussed. Processing is made feasible by utilizing charge-coupled devices (CCD). CCD circuits are utilized to perform input sampling, presumming, range correlation and azimuth correlation in the analog domain. These radar data processing functions are implemented for single-look or multiple-look imaging radar systems.

Arens, W. E.↗

Time delay and integration detectors using charge transfer devices

An imaging system comprises a multi-channel matrix array of CCD devices wherein a number of sensor cells (pixels) in each channel are subdivided and operated in discrete intercoupled groups of subarrays with a readout CCD shift register terminating each end of the channels. Clock voltages, applied to the subarrays, selectively cause charge signal flow in each subarray in either direction independent of the other subarrays. By selective application of four phase clock voltages, either one, two or all three of the sections subarray sections cause charge signal flow in one direction, while the remainder cause charge signal flow in the opposite direction. This creates a form of selective electronic exposure control which provides an effective variable time delay and integration of three, six or nine sensor cells or integration stages. The device is constructed on a semiconductor sustrate with a buried channel and is adapted for front surface imaging through transparent doped tin oxide gates.

Mccann, D. H.↗

Deep Learning Analysis of Polaritonic Wave Images

Deep learning (DL) is an emerging analysis tool across the sciences and engineering. Encouraged by the successes of DL in revealing quantitative trends in massive imaging data, we applied this approach to nanoscale deeply subdiffractional images of propagating polaritonic waves in complex materials. Utilizing the convolutional neural network (CNN), we developed a practical protocol for the rapid regression of images that quantifies the wavelength and the quality factor of polaritonic waves. Using simulated near-field images as training data, the CNN can be made to simultaneously extract polaritonic characteristics and material parameters in a time scale that is at least 3 orders of magnitude faster than common fitting/processing procedures. The CNN-based analysis was validated by examining the experimental near-field images of charge-transfer plasmon polaritons at graphene/α-RuCl3 interfaces. Our work provides a general framework for extracting quantitative information from images generated with a variety of scanning probe methods.

97 MATHEMATICS AND COMPUTING↗

Slide Test FY 2019 Report

At Los Alamos, the Slide Test was developed in 2019 to investigate whether the mass of a main charge of explosive sliding on a gritty surface, in the absence of impact, is sufficient to heat grit to ignition temperatures in PBX 9501. This is a practical test to address frictional ignition during assembly/disassembly operations at the Pantex Plant. Twenty-seven Slide Tests were performed in total, testing PBX 9501 at various slide velocities, grit diameters, grit patterns, and charge masses. Time-resolved velocimetry of the slide event (from PDV) and spot area of the explosive charge (obtained from image analysis) is reported. High-speed videography is used to diagnose explosive reaction. Eighteen of these tests were performed with a charge mass of 30 lbs at velocities ≤ 4 m s-1 and grit diameters between 75 and 1000 µm. Nine Slide Tests were performed with a 15 lb charge mass at similar parameters. No ignition was observed in any of the tests. These data provide evidence that the mass of a main charge, caused to slide on a surface at the low velocities achievable during routine handling, is insufficient stimulus to heat grit to ignition temperatures. These findings are relevant to risk assessment for explosive handling operations and provide evidence that PBX 9501 is safe within the constraints that were tested. However, because ignitions were not observed in any of the tests, we cannot determine which variables (mass or velocity) dominate the explosive response and to what extent. The absence of observed ignition also precludes the determination of a safety margin. To identify this safety margin, further research would be necessary to define the velocity and/or mass threshold at which ignition occurs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Microchannel spatial light modulator

The Microchannel Spatial Light Modulator (MSLM), a versatile, highly sensitive, and optically addressed device being developed for real time optical information processing is discussed. The MSLM operates by converting an input optical image into a charge distribution at the surface of an electro-optic crystal. The charge distribution generates an electric field which modulates the refractive index of the crystal and thereby the phase or intensity of an image readout beam. Prototype devices employing 250 micron thick crystals exhibited a spatial resolution of 5 cycles/mm at 50% contrast, an exposure sensitivity of 2.2 nJ/cu cm and framing rates of 40 Hz with full modulation depth. The image processing operations that have been achieved using the internal processing mode of the MSLM include contrast reversal, contrast enhancement, edge enhancement, image addition and subtraction, analog and digital intensity thresholding, and binary level logic operations such as AND, OR, EXCLUSIVE OR, and NOR.

Warde, C.↗

Determination of geometric distortion in STIS images

This is a report on the characterization of the geometric distortion of the Space Telescope Imaging Spectrograph (STIS) Charge Coupled Devices (CCD) and the STIS Far-Ultraviolet Multi-Anode Microchannel Arrays (FUV-MAMA) detectors when used in imaging mode. We find that the amount of the distortion is fairly small over most of the field. The maximum displacement is 1.66 pixels for the CCD and 2.71 pixels for the FUV-MAMA. This data also allows us to determine the plate scale for both cameras. For the CCD the scale is 0".05071 +/- 0".00007 /pixel. For the FUV-MAMA the scale is 0".02447 +/- 0".00001 /pixel in x and 0".02467 +/-0".00002 /pixel in y.

Malumuth, Eliot M.↗

Infrared nano-imaging of Dirac magnetoexcitons in graphene

Magnetic fields can have profound effects on the motion of electrons in quantum materials. Two-dimensional electron systems subject to strong magnetic fields are expected to exhibit quantized Hall conductivity, chiral edge currents and distinctive collective modes referred to as magnetoplasmons and magnetoexcitons. Generating these propagating collective modes in charge-neutral samples and imaging them at their native nanometre length scales have thus far been experimentally elusive. Here we visualize propagating magnetoexciton polaritons at their native length scales and report their magnetic-field-tunable dispersion in near-charge-neutral graphene. Imaging these collective modes and their associated nano-electro-optical responses allows us to identify polariton-modulated optical and photo-thermal electric effects at the sample edges, which are the most pronounced near charge neutrality. Our work is enabled by innovations in cryogenic near-field optical microscopy techniques that allow for the nano-imaging of the near-field responses of two-dimensional materials under magnetic fields up to 7 T. In conclusion, this nano-magneto-optics approach allows us to explore and manipulate magnetopolaritons in specimens with low carrier doping via harnessing high magnetic fields.

36 MATERIALS SCIENCE↗