Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dead time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

X-ray Characterization of a Multichannel Smart-Pixel Array Detector

The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

CMOS ASIC↗

Increasing the time resolution of a multichannel scaler.

Description of an economical buffer unit which will extend the time resolution of a multichannel scaler to better than 100 nsec. The buffered multiscaler produces a system which has negligible dead time between the bins even at the highest resolutions. It is suitable for use in any digital signaling averaging application which meets certain conditions.

Silverberg, E. C.↗

Analysis of a longitudinal pilot-induced oscillation experienced on the approach and landing test of the space shuttle

During the final free flight (FF-5) of the shuttle's approach and landing tests, the vehicle experienced pilot-induced oscillations near touchdown. The light test data showed that pilot inputs to the hand controller reached peak-to-peak amplitudes of 20 deg at a frequency between 3 and 3.5 radians per second. The controller inputs were sufficient to exceed the priority rate limit set in the pitch axis. A nonlinear analytical study was conducted to investigate the combined effects of pilot input, rate limiting, and time delays. The frequency response of the total system is presented parametrically as a function of the three variables. In general, with no dead time, for controller inputs of 5 deg or less, the total system behaves in a linear fashion. For 10 deg of controller input, independent of the delay time, the elevon loop will be rate saturated above a frequency of 4 radians per second.

Smith, J. W.↗

A cryogenic muon tagging system based on kinetic inductance detectors for superconducting quantum processors

Ionizing radiation has emerged as a potential limiting factor for superconducting quantum processors, inducing quasiparticle bursts and correlated errors that challenge fault-tolerant operation. Atmospheric muons are particularly problematic due to their high energy and penetration power, making passive shielding ineffective. Therefore, monitoring the real-time muon flux is crucial to guide the development of alternative error-correction or mitigation strategies. We present the design, simulation, and first operation of a cryogenic muon-tagging system based on kinetic inductance detectors (KIDs), developed as a stand-alone cryogenic particle-tagging module for superconducting quantum processors. The system consists of two KIDs arranged in a vertical stack and operated at ∼20 mK. Monte Carlo simulations based on Geant4 guided the prototype design and provided reference expectations for muon-tagging efficiency and accidental coincidences due to ambient γ-rays. We observed a muon-induced coincidence rate among the top and bottom detectors of (192 ± 9) $\times\,10^{-3}$ events s$^{−1}$, in excellent agreement with the Monte Carlo prediction. The prototype achieves a muon-tagging efficiency of about 90% with negligible dead time. These results demonstrate the feasibility of operating a muon-tagging system at millikelvin temperatures and represent a key step toward the integration of cryogenic veto systems with multi-qubit chips to mitigate muon-induced errors.

Mariani, Ambra [INFN, Rome] (ORCID:000000028184857↗

Apparatus for using a time interval counter to measure frequency stability

An apparatus for measuring the relative stability of two signals is disclosed comprising a means for mixing the two signals down to a beat note sine wave and for producing a beat note square wave whose upcrossings are the same as the sine wave. A source of reference frequency is supplied to a clock divider and interval counter to synchronize them and to generate a picket fence for providing a time reference grid of period shorter than the beat period. An interval counter is employed to make a preliminary measurement between successive upcrossings of the beat note square wave for providing an approximate time interval therebetween as a reference. The beat note square wave and the picket fence are then provided to the interval counter to provide an output consisting of the time difference between the upcrossing of each beat note square wave cycle and the next picket fence pulse such that the counter is ready for each upcrossing and dead time is avoided. A computer containing an algorithm for calculating the exact times of the beat note upcrossings then computes the upcrossing times.

Greenhall, Charles A.↗

GRB 221009A: The B.O.A.T. Burst that Shines in Gamma Rays

We present a complete analysis of Fermi Large Area Telescope (LAT) data of GRB 221009A, the brightest gamma-ray burst (GRB) ever detected. The burst emission above 30 MeV detected by the LAT preceded, by 1 s, the low-energy (<10 MeV) pulse that triggered the Fermi Gamma-Ray Burst Monitor (GBM), as has been observed in other GRBs. The prompt phase of GRB 221009A lasted a few hundred seconds. It was so bright that we identify a bad time interval of 64 s caused by the extremely high flux of hard X-rays and soft gamma rays, during which the event reconstruction efficiency was poor and the dead time fraction quite high. The late-time emission decayed as a power law, but the extrapolation of the late-time emission during the first 450 s suggests that the afterglow started during the prompt emission. We also found that high-energy events observed by the LAT are incompatible with synchrotron origin, and, during the prompt emission, are more likely related to an extra component identified as synchrotron self-Compton (SSC). A remarkable 400 GeV photon, detected by the LAT 33 ks after the GBM trigger and directionally consistent with the location of GRB 221009A, is hard to explain as a product of SSC or TeV electromagnetic cascades, and the process responsible for its origin is uncertain. Because of its proximity and energetic nature, GRB 221009A is an extremely rare event.

79 ASTRONOMY AND ASTROPHYSICS↗

1 kV, 10-kW SiC-Based Quadruple Active Bridge DCX Stage in a DC to Three-Phase AC Module for Medium-Voltage Grid Integration

Interfacing low voltage dc to medium voltage three-phase ac grid is often based on series-stackable modular converter architectures. To minimize energy storage requirements, it is advantageous to employ a quadruple active bridge (QAB) stage operating as a "dc transformer" in each stackable module. The QAB stage offers three isolated dc link voltages, which then allow for flexible stacking of three single-phase dc-to-ac inverter stages. Each of the module phases processes a pulsating power having a component at twice the line frequency. This presents a challenge in maintaining zero voltage switching (ZVS) on the secondary sides of the QAB during low-power portions of the line cycle. This article is focused on the design of the QAB stage. A detailed analysis of ZVS switching waveforms is presented, including effects of nonlinear device capacitances. It is shown how ZVS can be achieved at all times using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. Analytical expressions are given for the optimal values of the magnetizing inductance and the dead times of the QAB primary and secondary bridges. This approach is verified by experimental results on a 1 kV, 10-kW SiC-based prototype, demonstrating a relatively flat efficiency curve with a peak efficiency of 97.1% at 75% load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamically Reconfigurable Data Readout of Pixel Detectors for Automatic Synchronization with Data Acquisition Systems

Reconfigurable detectors with dynamically selectable sensing and readout modes are highly desirable for implementing edge computing as well as enabling advanced imaging techniques such as foveation. The concept of a camera system capable of simultaneous passive imaging and dynamic ranging in different regions of the detector is presented. Such an adaptive-autonomous detector with both spatial and temporal control requires programmable window of exposure (time frames), ability to switch between readout modes such as full-frame imaging and zero-suppressed data, modification of the number of pixel data bits and independent programmability for distinct detector regions. In this work, a method is presented for seamlessly changing time frames and readout modes without data corruption while still ensuring that the data acquisition system (DAQ) does not need to stop and resynchronize at each change of setting, thus avoiding significant dead time. Data throughput is maximized by using a minimum unique data format, rather than lengthy frame headers, to differentiate between consecutive frames. A data control and transmitter (DCT) synchronizes data transfer from the pixel to the periphery, reconfigures the data to transmit it serially off-chip, while providing optimized decision support based on a DAQ definable mode. Measurements on a test structure demonstrate that the DCT can operate at 1 GHz in a 65 nm LP CMOS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combination of two Gas Electron Multipliers and a Micromegas as gain elements for a time projection chamber

We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space charge in the drift volume of such detectors in order to eliminate the standard gating grid and its resultant dead time, while preserving good tracking and particle identification performance. To characterize this micro-pattern gas detector configuration, we measured the positive ion back-flow and energy resolution at various element gains and electric fields, using a variety of gases, and additionally studied crosstalk effects and discharge rates. At a gain of 2000, this configuration achieves an ion back-flow below 0.4% and an energy resolution better than σ / E = 12 % for 55 Fe X-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for using a time interval counter to measure frequency stability

It is shown how a commercial time interval counter can be used to measure the relative stability of two signals that are offset in frequency and mixed down to a beat note of about 1 Hz. To avoid the dead-time problem, the counter is set up to read the time interval between each beat note upcrossing and the next pulse of a 10 Hz reference pulse train. The actual upcrossing times are recovered by a simple algorithm whose outputs can be used for computing residuals and Allan variance. A noise floor-test yielded a delta f/f Allan deviation of 1.3 times 10 to the minus 9th power/tau relative to the beat frequency.

Greenhall, C. A.↗

A method for using a time interval counter to measure frequency stability

It is shown how a commercial time interval counter can be used to measure the relative stability of two signals that are offset in frequency and mixed down to a beat note of about 1 Hz. To avoid the dead-time problem, the counter is set up to read the time interval between each beat note upcrossing and the next pulse of a 10 Hz reference pulse train. The actual upcrossing times are recovered by a simple algorithm whose outputs can be used for computing residuals and Allan variance. A noise floor-test yielded a delta f-f Allan deviation of 1.3 times 10 to the minus 9th power/tau relative to the beat frequency.

Greenhall, Charles A.↗

Study of cosmogenic activation above ground for the DarkSide-20k experiment

The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39 Ar. Despite the outstanding capability of discriminating γ / β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39 Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37 Ar and 3 H are shown not to be relevant due to short half-life and assumed purification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science Addendum

Activation detectors developed at LLNL for measuring real-time neutron fluence from fusion sources are used in the broader fusion community. The recommended fluence operating range of this diagnostic is 5x10 2 – 1x10 6 n/cm2. The upper limit on this fluence range is set by the dead time caused by data transfer between the detector and data acquisition computer. Delaying the start of counting is a possible strategy to operate these detectors in higher fluences.

42 ENGINEERING↗

CDEX-1 1 kg point-contact germanium detector for low mass dark matter searches

The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p + electrode and the outside n + electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p + and n + electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The level-1 trigger for the SuperCDMS experiment at SNOLAB

The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to Script O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filter provides a baseline resolution of 0.38 times the standard deviation of the noise, σn, and a 99.9% trigger efficiency for signal amplitudes of 1.1 σ n in typical noise conditions. Embedded in a modular architecture, flexible trigger logic enables reliable triggering and vetoing in a dead-time-free manner for a variety of purposes and run conditions. The trigger architecture and performance are detailed in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronization for Optical PPM Signals

Method based on statistical properties of weak pulse-positionmodulated (PPM) signal enables synchronization of receiver clock with received-signal time base. Method applies to weak optical M-ary PPM signals, for which there is only one pulse of length Tp transmitted during one of timeslots of length T in each successive interval of M timeslots. Method requires small dead time, Td, at beginning and end of each timeslot, during which pulse amplitude is zero.

Vilnrotter, V. A.↗

Physics insights from a large-scale 2D UEDGE simulation database for detachment control in KSTAR

A large-scale database of two-dimensional UEDGE simulations has been developed to study detachment physics in KSTAR and to support surrogate models for control applications. Nearly 70 000 steady-state solutions were generated, systematically scanning upstream density, input power, plasma current, impurity fraction, and anomalous transport coefficients, with magnetic and electric drifts across the magnetic field included. The database identifies robust detachment indicators, with strike-point electron temperature at detachment onset consistently T e,target ~ 3-4 eV, largely insensitive to upstream conditions. Scaling relations reveal weaker impurity sensitivity than one-dimensional models and show that heat flux widths follow Eich’s scaling only for uniform, low D and χ. Distinctive in–out divertor asymmetries are observed in KSTAR, differing qualitatively from DIII-D. Complementary time-dependent simulations quantify plasma response to gas puffing, with delays of 5 - 15 ms at the outer strike point and ∼ 40 ms for the low-magnetic-field-side radiation front. These dynamics are well captured by first-order-plus-dead-time models and are consistent with experimentally observed detachment-control behavior in KSTAR (Gupta et al 2025 Plasma Phys. Control. Fusion (submitted)).

Physics - Plasma physics↗

Investigation of Timing Properties for an Event Driven with Access and Reset Decoder Readout Architecture for a Pixel Array

The large number of data generating sources (data channels) on a single chip requires appropriate techniques to manage a readout from these channels. One of the main methods is sharing a medium of transmission, which requires arbitration to avoid collisions or deadlocks. Existing solutions face several problems such as a dead time, unintended prioritization or metastability. That is why we decided to create a new readout architecture named EDWARD i.e., Event Driven with Access and Reset Decoder. The EDWARD architecture gets rid of the earlier mentioned problems and mitigates the other ones. However, due to the use of logic circuits outside a standard cell library, which are hard to characterize, we were challenged to perform an additional transient analysis to validate the architecture. Here we show a methodology and the results of the simulations. Based on the results obtained we can confirm the functional correctness of the system and plan the optimization of operating conditions in order to achieve better performance. Our goal is to use the EDWARD architecture in the future radiation detectors to be built at Brookhaven National Laboratory.

47 OTHER INSTRUMENTATION↗