PULSED NEUTRON EXPERIMENTS IN THE INHERENTLY SAFE SUBCRITICAL ASSEMBLY
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.
The Thermal Hydraulic Experimental Test Article (THETA) is currently installed in the Mechanisms Engineering Test Loop (METL) 28” test vessel #4. Both the primary and secondary sodium systems remain online to facilitate continued testing. This fiscal year, work was performed using a COMSOL Multiphysics magnetohydrodynamic model to characterize flow more accurately in the secondary electromagnetic flowmeters. Experimental campaigns were then performed to study the thermal hydraulic differences between sodium and water as a surrogate fluid in the THETA geometry as well as a study to better characterize and understand temperature oscillations that exist at the outlet of the core to the hot pool. A peer-reviewed article was published in the ASME Journal of Nuclear Engineering and Radiation Science detailing the THETA facility and providing an overview of a test that was performed with the primary and secondary system online [1]. Work continues to develop a database to house experimental THETA data to better facilitate collaboration with industry and laboratory partners for their use of the data for code benchmarking/validation. THETA remains fully operational and is positioned for continued testing in fiscal year 2026.
The ability to differentiate between atmospheric radionuclide signatures from underground nuclear explosions (UNEs) and signals from other sources, such as medical isotope-production facilities and nuclear reactors, can be critical to the detection and monitoring of unannounced, low-yield nuclear events. Signatures having anomalously high amplitudes, compared to background levels, remain the best indicator in screening for a UNE. However, isotopic composition can further validate a suspected UNE signature, but separation from any atmospheric background composition is first necessary. To date, evaluating the challenges of performing this separation has typically involved comparing an observed background with a highly idealized deterministic model of radioxenon signature production by a UNE that does not consider the influence of post-detonation chemical/physical processes in the detonation cavity or the subsequent gas transport mechanisms that can also affect the isotopic composition of the detected gas signature. In addition, purely deterministic models, as previously employed, overlook the uncertainty inherent in estimating critical parameters characterizing the UNE and its detonation environment. In this paper, we create detailed, multi-parameter models of radionuclide evolution using the widely accepted England and Rider post-detonation radionuclide decay-chain network coupled to detailed models simulating physical production and transport processes affecting the gas signature. Because these models are governed by uncertain parameters including barometric fluctuations, realistic ranges of variation for each of the parameters influencing isotopic composition are then defined. A Latin-Hypercube sampling approach is used to obtain a random distribution of isotopic production and gas transport results associated with a given value of each parameter. We apply these results to background histories of two stations, one providing 4-isotope background measurements and the other providing two-isotope measurements associated with the 2013 DPRK announced UNE.
This report contains a summary of highlights and top achievements from Los Alamos National Laboratory from December 2023, including Nuclear Security, Science Technology & Engineering, Mission Operations, and Community Relations.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Activation detectors developed at LLNL for measuring real-time neutron fluence from fusion sources are used in the broader fusion community. The recommended fluence operating range of this diagnostic is 5x10 2 – 1x10 6 n/cm2. The upper limit on this fluence range is set by the dead time caused by data transfer between the detector and data acquisition computer. Delaying the start of counting is a possible strategy to operate these detectors in higher fluences.
The Laboratory has four strategic objectives: nuclear security; mission-focused science, technology, and engineering; mission operations; and community relations. To accomplish our mission, excellence in all areas is our objective — we call that simultaneous excellence. To achieve simultaneous excellence, we apply the Safe Conduct of Research principles, an essential part of our strategy.
This publication highlights achievements in nuclear security, science, technology and engineering, mission operations, and community relations at Los Alamos National Laboratory.
This publication highlights achievements in nuclear security, science, technology and engineering, mission operations, and community relations at Los Alamos National Laboratory.
This publication highlights achievements in nuclear security, science, technology and engineering, mission operations, and community relations at Los Alamos National Laboratory.
Focused Very-High Energy Electron (VHEE, 50–300 MeV) and Ultra-High Energy Electron (UHEE, > 300 MeV) beams can accurately target both large and deeply seated human tumors with high sparing properties, while avoiding the spatial requirements and cost of proton and heavy ion facilities. Advanced testing phases are underway at the CLEAR facilities at CERN (Switzerland), NLCTA at Stanford (USA), and SPARC at INFN (Italy), aiming to accelerate the transition to clinical application. Currently, Monte Carlo (MC) transport is the sole paradigm supporting preclinical trials and imminent clinical deployment. In this paper, we propose an alternative: the first extension of the nuclear-reactor deterministic chain Njoy-Dragon for VHEE and UHEE applications. We have extended the Boltzmann-Fokker-Planck (BFP) multigroup formalism and validated it using standard radio-oncology benchmarks, complex assemblies with a wide range of atomic numbers, and comprehensive irradiation of the entire periodic table. We report that 99% of water voxels exhibit a BFP-MC deviation below 2% for electron energies under 1.5 GeV. Additionally, we demonstrate that at least 97% of voxels of bone, lung, adipose tissue, muscle, soft tissue, tumor, steel, and aluminum meet the same criterion between 50 MeV and 1.5 GeV. For water, the thorax, and the breast intra-operative benchmark, typical average BFP-MC deviations of 0.3% and 0.4% were observed at 300 MeV and 1 GeV, respectively. By irradiating the entire periodic table, we observed similar performance between lithium (Z = 3) and cerium (Z = 58). Deficiencies observed between praseodymium (Z = 59) and einsteinium (Z = 99) have been reported, analyzed, and quantified, offering critical insights for the ongoing development of the Evaluated Nuclear Data File mode in NJOY.
This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.
Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration. The National Nuclear Security Administration’s Sandia Field Office administers the contract and oversees contractor operations at Sandia National Laboratories, California. Activities at this multiprogram engineering and science laboratory support the nuclear weapons stockpile program, energy and environmental research, homeland security, micro- and nanotechnologies, and basic science and engineering research. The U.S. Department of Energy and its management and operating contractor are committed to safeguarding the environment, assessing sustainability practices, and ensuring the validity and accuracy of the monitoring data presented in this annual site environmental report. This report provides a summary of environmental monitoring information and compliance activities that occurred at Sandia National Laboratories, California during calendar year 2022 unless noted otherwise. General site and environmental program information is also included. This report was prepared in accordance with DOE O 231.1B, Environment, Safety and Health Reporting.