Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Investigation of Microscopic Materials Limitations of Superconducting RF Cavities

The high-field performance of SRF cavities is often limited by breakdown events below the intrinsic limiting surface fields of Nb, and there is abundant evidence that these breakdown events are localized in space inside the cavity. Also, there is a lack of detailed understanding of the causal links between surface treatments and ultimate RF performance at low temperatures. An understanding of these links would provide a clear roadmap for improvement of SRF cavity performance, and establish a cause-and-effect ‘RF materials science’ of Nb. We propose two specific microscopic approaches to addressing these issues. First is a spatially-resolved local microwave-microscope probe that operates at SRF frequencies and temperatures to discover the microscopic origins of breakdown, and produce quantitative measurements of RF critical fields of coatings and films. Second, RF Laser Scanning Microscopy (LSM) has allowed visualization of RF current flow and sources of nonlinear RF response in superconducting devices with micro-meter spatial resolution. The LSM will be used in conjunction with surface preparation and characterization techniques to create definitive links between physical and chemical processing steps and ultimate cryogenic microwave performance. We propose to develop RF laser scanning microscopy of small-sample Nb pieces to establish surface-processing / RF performance relations through measurement of RF current distributions on micron-length scales and low temperatures.

36 MATERIALS SCIENCE↗

Microscopic Investigation of Materials Limitations of Superconducting RF Cavities

Our overall goal is to contribute to the understanding of defects that limit the high accelerating gradient performance of Nb SRF cavities. Our approach is to develop a microscopic connection between materials defects and SRF performance. We developed a near-field microwave microscope to establish this connection. The microscope is based on magnetic hard drive write heads, which are designed to create very strong rf magnetic fields in very small volumes on a surface.

36 MATERIALS SCIENCE↗

Development of the Tagger Microscope & Analysis of Spin Density Matrix Elements in gamma-p -> phi-p for the GlueX Experiment

The quark model has been successful in classifying the spectrum of mesons observed since the 1960s, however, it fails to explain some of the measured bound states. Lattice QCD predictions have shown that an excited gluonic field may contribute to the quantum numbers of the bound state and form hybrid mesons, qq-bar-g, where g is a constituent gluon. It is possible for some hybrids to possess quantum numbers forbidden by the quark model and are known as \smoking gun" hybrids due to their lack of mixing with conventional qq-bar states. The GlueX photoproduction experiment at Jefferson Lab in Newport News, VA is designed to study hybrid mesons and to map their spectrum. A 12 GeV electron beam produces 9 GeV linearly polarized photons via coherent bremsstrahlung in a diamond radiator which are incident on a liquid H2 target. In order to determine the photon energy, the use of a tagging spectrometer which measures the energy of the post-bremsstrahlung electron is required. The tagger microscope is a scintillating fiber detector designed to measure the energy of electrons corresponding to the polarized photons. The main focus of this work is the design and construction of the tagger microscope electronics as well as the calibration of the microscope within the experiment. Additionally, the analysis of the reaction gamma-p -> phi-p, where phi (1020) -> K+K-, is discussed. This analysis provides a high-level calibration for GlueX in regards to understanding the acceptance and sensitivity of the detectors to mesons with strange quark content. By studying the phi with linearly polarized photons, information on the production mechanism can be extracted. The measurement of the phi spin-density matrix elements are shown and compared with past data which are found to be in agreement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vibrational Sum Frequency Generation Spectroscopy Microscope

Vibrational sum frequency generation spectroscopy has the benefit of being very surface-specific, aiding in the the investigation of a given material’s surface chemical and physical properties. As such, the goal of this project was to construct a sum frequency generation microscope that would enable the investigation of surface phenomena on a microscopic scale. Currently, the microscope hardware has been assembled and programmed, and simple spectral images were taken with elastically scattered 532 nm light. These images indicate an image resolution near 3 µm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and implementation of an in situ high-resolution isotopic microscope for measuring metabolic interactions in soil mesocosms (Final Report)

Many of our planet’s ecosystems rely on the activities of soil microbial communities. These microbes have significant and wide-ranging effects: they metabolize carbon and other nutrients, interact with plants and fungi, and perform other processes important to soil health. However, our ability to directly observe the enzymatic and metabolic activities of microbes within soil is currently limited, not only by the complexity of soil microbial communities themselves, but also by the lack of experimental tools to study them and their molecular interactions in situ. These challenges hinder our understanding of the life-sustaining processes of biomass decomposition and the manner in which it contributes to the movement of freed carbon within soil ecosystems. Here we aimed to develop a novel ultrahigh-resolution isotopic microscope that combines complementary imaging modalities to gain insights into metabolic cycling in soil. This final report covers both the portion of this work that was initially completed at the University of North Carolina at Chapel Hill from 2018 to 2019 (as award DE-SC0019012) and then from 2020 to 2022 (2023 in NCE) at the University of Massachusetts Chan Medical School. This goal was to build an integrated platform consisting of fluorescence microscopy, Raman microspectroscopy, and nanospray desorption electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoDESI-FTICR-MS) to directly investigate microbial activities and molecular transformations occurring in soil by exploiting the use of both fluorescent labels and stable isotope probing. Specifically, our instrument was conceived as integrating: (A) fluorescence detection to localize soil microbes, identify bacteria taking up polysaccharides, and monitor gene expression of enzymes involved in decomposition; (B) Raman microspectroscopy to determine which microbes incorporate decomposition products into their biomass, as well as which decomposers are metabolically active; and (C) nanoDESI-FTICR-MS imaging to spatially probe, in real-time, the metabolites in the surrounding area, which we expect will reveal the distributions of the products of the enzymatic breakdown of polysaccharides, as well as specialized metabolites acting as cell-cell signals between decomposers. To enable these measurements, we exploited fluorescence-based probes to map the microbes that are enzymatically active (per A) and utilized stable isotope-labeled substrates to visualize both the microbial and molecular fate of decomposed biomass (B and C, respectively). To accomplish our goal, we combined the expertise of a multidisciplinary group of scientists to pursue the construction of this microscope and to investigate scientific questions that would be facilitated by such a capability. We aimed to employ this spatially informative, high-resolution isotopic microscope to visualize the critical steps of biomass degradation and the molecular fate of other environmentally relevant substrates within soil mesocosms. Accordingly, this technology will enhance our understanding of the microbial and metabolic interactions occurring within soil communities that are relevant to carbon degradation and other soil processes. The instrument has been developed and housed at EMSL, where it will be available to the entire EMSL User Base, enabling a variety of related DOE-relevant systems to be interrogated in the future by diverse scientific research groups.

59 BASIC BIOLOGICAL SCIENCES↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Spectro-Microscopic Measurements of Carbonaceous Aerosol Aging in Central California

Carbonaceous aerosols are responsible for large uncertainties in climate models, degraded visibility, and adverse health effects. The Carbonaceous Aerosols and Radiative Effects Study (CARES) was designed to study carbonaceous aerosols in the natural environment of Central Valley, California, and learn more about their atmospheric formation and aging. This paper presents results from spectro-microscopic measurements of carbonaceous particles collected during CARES at the time of pollution accumulation event (June 27-29, 2010), when in situ measurements indicated an increase in the organic carbon content of aerosols as the Sacramento urban plume aged. Computer controlled scanning electron microscopy coupled with an energy dispersive X-ray detector (CCSEM/EDX) and scanning transmission X-ray microscopy coupled with near edge X-ray absorption spectroscopy (STXM/NEXAFS) were used to probe the chemical composition and morphology of individual particles. It was found that the mass of organic carbon on individual particles increased through condensation of secondary organic aerosol. STXM/NEXAFS indicated that the number fraction of homogenous organic particles lacking inorganic inclusions (greater than ~50 nm diameter) increased with plume age as did the organic mass per particle. Comparison of the CARES spectro-microscopic data set with a similar dataset obtained in Mexico City during the MILAGRO campaign showed that individual particles in Mexico City contained twice as much carbon as those sampled during CARES. The number fraction of soot particles at the Mexico City urban site (30%) was larger than at the CARES urban site (10%) and the most aged samples from CARES contained less carbon-carbon double bonds. Differences between carbonaceous particles in Mexico City and California result from different sources, photochemical conditions, gas phase reactants, and secondary organic aerosol precursors. The detailed results provided by these spectro-microscopic measurements will allow for a comprehensive evaluation of aerosol process models used in climate research.

Environmental Molecular Sciences Laboratory↗

A large granite stage and measuring microscope.

A stage and measuring microscope servocontrolled by a computer have been constructed. The travel of the stage is 0.5 x 0.5 m and the travel of the microscope objective is 7.5 cm. The measuring accuracy is 1 micron in the x-y plane and 5 microns along the z axis. The mechanical and optical construction of the stage and microscope, as well as the way in which the control electronics are organized, permit great flexibility of operation. Possible applications include the scanning and measuring of astronomical plates, the laying out of patterns of semiconductor devices of very large sizes, and the measurement of precision grids.

Alston-Garnjost, M.↗

Study of a quasi-microscope design for planetary landers

The Viking Lander fascimile camera, in its present form, provides for a minimum object distance of 1.9 meters, at which distance its resolution of 0.0007 radian provides an object resolution of 1.33 millimeters. It was deemed desirable, especially for follow-on Viking missions, to provide means for examing Martian terrain at resolutions considerably higher than that now provided. This led to the concept of quasi-microscope, an attachment to be used in conjunction with the fascimile camera to convert it to a low power microscope. The results are reported of an investigation to consider alternate optical configurations for the quasi-microscope and to develop optical designs for the selected system or systems. Initial requirements included consideration of object resolutions in the range of 2 to 50 micrometers, an available field of view of the order of 500 pixels, and no significant modifications to the fascimile camera.

Giat, O.↗

Microscopic investigation of cavitation erosion damage in metals

The results of research to identify the cavitation erosion damage mechanisms at the microscopic level for three metals (aluminum, stainless steel, and titanium) representing a range of properties and microstructure are presented. The metals were exposed to cavitation generated in distilled water by a 20-kHz ultrasonic facility operating at a vibration amplitude of 2 mils. Representative properties of the metals and experimental details are summarized. Replicas of the eroded surfaces of the specimens obtained periodically during exposure were examined with a transmission electron microscope to follow progression of the erosion damage and identify dominant erosion mechanisms as a function of exposure time. Eroded surfaces of selected specimens were also examined with a scanning electron microscope to assist in the interpretation.

Hackworh, J. V.↗

Molecular rotation and reorientation - Microscopic and hydrodynamic contributions

The relative roles of microscopic and hydrodynamic contributions to molecular rotation and reorientation are examined within the framework of the microscopic boundary layer theory recently proposed by the authors. The theory is applied to rough spheres, for which computer simulation data are available and to experimental results on spherical top molecules. Attention is focused on rotational diffusion constants, the kappa parameter introduced by Kivelson et al., and orientational relaxation times. It is shown that, while collective effects are present and often nonnegligible, the motion of small molecules is dominated by its microscopic aspects. Experimental trends which can incorrectly suggest dominance by hydrodynamic contributions are discussed in some detail. Finally, the transition to the regime where collective effects are dominant is considered.

Hynes, J. T.↗

Design of an imaging microscope for soft X-ray applications

An imaging soft X-ray microscope with a spatial resolution of 0.1 micron and normal incidence multilayer optics is discussed. The microscope has a Schwarzschild configuration, which consists of two concentric spherical mirrors with radii of curvature which minimize third-order spherical aberration, coma, and astigmatism. The performance of the Stanford/MSFC Cassegrain X-ray telescope and its relevance to the present microscope are addressed. A ray tracing analysis of the optical system indicates that diffraction-limited performance can be expected for an object height of 0.2 mm.

Hoover, Richard B.↗

Development of a normal incidence multilayer, imaging X-ray microscope

This paper describes the design, analysis, and fabrication of a normal-incidence multilayer 20x Schwarzschild imaging X-ray microscope. The microscope is being fabricated using much of the technology implemented in the Multispectral Solar Telescope Array. Results of diffraction analysis show that better than 400 A spatial resolution in the object plane up to a 1-mm field of view can be achieved with 125 A radiation. Other microscope systems for use in conjunction with X-ray telescopes are analyzed and designed.

Shealy, David L.↗

Sample holder support for microscopes

A sample filter holder is disclosed for use with a microscope for holding the filter in a planar condition on the stage of the microscope so that automatic focusing of the microscope can be performed on particle samples dispersed on the filter. The holder includes a base having a well that communicates with an inlet port which is connected to a suction pump. A screen assembly is positioned within the well. The screen assembly includes a disk having a screen positioned on its top surface and secured to the disk at the peripheral edge of the screen. Small bores allow the outer surface of the screen to communicate with the well. The filter is placed on the screen and is held in a flat disposition by the suction forces.

Berry, Anthony↗

Design and analysis of aspherical multilayer imaging X-ray microscope

Spherical Schwarzschild microscopes for soft X-ray applications in microscopy and projection lithography employ two concentric spherical mirrors that are configured such that the third-order spherical aberration and coma are zero. Based on incoherent, sine-wave MTF calculations, the object-plane resolution of a magnification-factor-20 microscope is presently analyzed as a function of object height and numerical aperture of the primary for several spherical Schwarzschild, conic, and aspherical two-mirror microscope configurations.

Shealy, David L.↗

Determination of the Critical Parameters for Remote Microscope Control

As part of a program to determine the capabilities of Telescience as applied to Microgravity Materials Science the need for a remotely controlled microscope was recognized. For this purpose we equipped a microscope with an X-Y-Z positioning device and motors on the zoom and focus controls. Computer control of these devices allowed remote operation. A standard TV camera was mounted to the computer controlled video board which could compress the image in resolution and grey scale. The operator control console was programmed to display three still video pictures as well as provide command access. A standard data transfer network was used to transmit the video data files and the command interaction was via a high speed phone modem. This system, with the microscope in the Microgravity Materials Science Laboratory (MMSL) at LeRC and the control at RPI, was used to determine the accuracy of setting, time required to achieve setting and the operator ease factor. It was found that the focus setting could be established well within the resolution limit of the TV system and that each motion took about 50 seconds and approximately 12 minutes was required to reach ?best? focus. These times could be reduced significantly with operator experience. The operators were provided with ancillary equipment which provided assistance in making the necessary decisions and they reported satisfaction with the control.

Hahn, R. C.↗

Fuzzy control system for a remote focusing microscope

Space Station Crew Health Care System procedures require the use of an on-board microscope whose slide images will be transmitted for analysis by ground-based microbiologists. Focusing of microscope slides is low on the list of crew priorities, so NASA is investigating the option of telerobotic focusing controlled by the microbiologist on the ground, using continuous video feedback. However, even at Space Station distances, the transmission time lag may disrupt the focusing process, severely limiting the number of slides that can be analyzed within a given bandwidth allocation. Substantial time could be saved if on-board automation could pre-focus each slide before transmission. The authors demonstrate the feasibility of on-board automatic focusing using a fuzzy logic ruled-based system to bring the slide image into focus. The original prototype system was produced in under two months and at low cost. Slide images are captured by a video camera, then digitized by gray-scale value. A software function calculates an index of 'sharpness' based on gray-scale contrasts. The fuzzy logic rule-based system uses feedback to set the microscope's focusing control in an attempt to maximize sharpness. The systems as currently implemented performs satisfactorily in focusing a variety of slide types at magnification levels ranging from 10 to 1000x. Although feasibility has been demonstrated, the system's performance and usability could be improved substantially in four ways: by upgrading the quality and resolution of the video imaging system (including the use of full color); by empirically defining and calibrating the index of image sharpness; by letting the overall focusing strategy vary depending on user-specified parameters; and by fine-tuning the fuzzy rules, set definitions, and procedures used.

Weiss, Jonathan J.↗

The microscopic state of the solar wind: Links between composition, velocity distributions, waves and turbulence

An overview is given of the microscopic state of the solar wind with emphasis on recent Ulysses high-latitude observations and previous Helios in-ecliptic observations. The possible links between composition, ionization state. velocity distribution functions of electrons, protons and heavy ions. kinetic plasma waves and MHD-scale turbulence are elaborated. Emphasis is placed on a connection of interplanetary kinetic-scale phenomena with their generating microscopic processes in the corona. The fast streams seem to consist of mesoscale pressure-balanced plasma filaments and magnetic flux tubes, reminiscent of the supergranular-size structures building the open corona, from which copious Alfven waves emanate. The wind from the magnetically structured and active corona shows developed compressive turbulence and considerable abundance and ionization state variations. Some modelling attempts to explain the observed element fractionation are briefly reviewed. The causes of the nonthermal particle features. such as proton-ion differential streaming, ion beams. temperature anisotropies, and skewed distributions associated with collisionless heat conduction, are ultimately to be searched in the fact, that the corona is never quiescent but fundamentally variable in space and time. Consequently, the radial evolution of the internal state of the wind resembles at all latitudes a complicated relaxation process, in the course of which the free (in comparison with LTE conditions) particle kinetic energy is converted into plasma waves and MHD turbulence on a wide range of scales. This leads to intermittent wave-particle interactions and unsteady anomalous transport, mixed with the weak effects of the rare Coulomb collisions. Spherical expansion and large-scale inhomogeneity forces the wind to attain microscopically a complex internal state of dynamic statistical equilibrium.

Marsch, E.↗