Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Leak Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Solid-Sorbent Air Sampler

Portable unit takes eight 24-hour samples. Volatile organic compounds in air collected for analysis by portable, self-contained sampling apparatus. Sampled air drawn through sorbent material, commercial porous polymer of 2, 3-diphenyl-p-phenylene oxide. High-boiling-point organic compounds adsorbed onto polymer, while low-boiling-point organics pass through and returned to atmosphere. Sampler includes eight sample tubes filled with polymeric sorbent. Organic compounds in atmosphere absorbed when air pumped through sorbent. Designed for checking air in spacecraft, sampler adaptable to other applications as leak detection, gas-mixture analysis, and ambient-air monitoring.

Galen, T. J.↗

Environmental projects. Volume 2: Underground storage tanks compliance program

Six large parabolic dish antennas are located at the Goldstone Deep Space Communications Complex north of Barstow, California. As a large-scale facility located in a remote, isolated desert region, the GDSCC operations require numerous on-site storage facilities for gasoline, diesel and hydraulic oil. These essential fluids are stored in underground storage tanks (USTs). Because USTs may develop leaks with the resultant seepage of their hazardous contents into the surrounding soil, local, State and Federal authorities have adopted stringent regulations for the testing and maintenance of USTs. Under the supervision of JPL's Office of Telecommunications and Data Acquisition, a year-long program has brought 27 USTs at the Goldstone Complex into compliance with Federal, State of California and County of San Bernadino regulations. Of these 27 USTs, 15 are operating today, 11 have been temporary closed down, and 1 abandoned in place. In 1989, the 15 USTs now operating at the Goldstone DSCC will be replaced either by modern, double-walled USTs equipped with automatic sensors for leak detection, or by above ground storage tanks. The 11 inactivated USTs are to be excavated, removed and disposed of according to regulation.

Kushner, L.↗

A nonlinear filtering process diagnostic system for the Space Station

A nonlinear filtering process diagnostic system, terrestrial simulation and real time implementation studies is presented. Possible applications to Space Station subsystem elements are discussed. A process diagnostic system using model based nonlinear filtering for systems with random structure was shown to provide improvements in stability, robustness, and overall performance in comparison to linear filter based systems. A suboptimal version of the nonlinear filter (zero order approximation filter, or ZOA filter) was used in simulation studies, initially, with a pressurized water reactor model and then with water/steam heat exchanger models. Finally, a real time implementation for leak detection in a water/steam heat exchanger was conducted using the ZOA filter and heat exchanger models.

Yoel, Raymond R.↗

Research into the interaction between high performance and cognitive skills in an intelligent tutoring system

Two intelligent tutoring systems were developed. These tutoring systems are being used to study the effectiveness of intelligent tutoring systems in training high performance tasks and the interrelationship of high performance and cognitive tasks. The two tutoring systems, referred to as the Console Operations Tutors, were built using the same basic approach to the design of an intelligent tutoring system. This design approach allowed researchers to more rapidly implement the cognitively based tutor, the OMS Leak Detect Tutor, by using the foundation of code generated in the development of the high performance based tutor, the Manual Select Keyboard (MSK). It is believed that the approach can be further generalized to develop a generic intelligent tutoring system implementation tool.

Fink, Pamela K.↗

Advanced optical condition monitoring

The application of Advanced Optical Condition Monitoring to optical leak detection and plume spectrometry is discussed. The development of these selected sensors for propulsion system monitoring is addressed.

Cross, G.↗

Welding of the superfluid helium on-orbit transfer (SHOOT) Flight Demonstration tanks and hardware

The SHOOT Flight Demonstration will provide the technology necessary to resupply superfluid helium in space. The helium dewars in SHOOT have unique requirements, including no detectable leaks, demonstrated structural integrity to allow flight aboard the Space Shuttle, and low parasitic heat leak. The requirements, materials, and processes used to fabricate the two superfluid helium dewars, particularly as they apply to welding, are presented.

Mcclure, Sidney↗

Nickel-hydrogen CPV battery update

The multicell common pressure vessel (CPV) nickel hydrogen battery manufactured by Johnson Controls Battery Group, Inc. has completed full flight qualification, including random vibration at 19.5 g for two minutes in each axis, electrical characterization in a thermal vacuum chamber, and mass-spectroscopy vessel leak detection. A first launch is scheduled for late in 1992 or early 1993 by the Naval Research Laboratory (NRL). Specifics of the launch date are not available at this time due to the classified nature of the program. Release of orbital data for the battery is anticipated following the launch.

Jones, Kenneth R.↗

Satellite Test Assistant Robot (STAR)

A three-year, three-phase program to demonstrate the applicability of telerobotic technology to the testing of satellites and other spacecraft has been initiated. Specifically, the objectives are to design, fabricate, and install into the JPL 25-ft. Space Simulator (SS) a system that will provide the capability to view test articles from all directions in both the visible and infrared (IR) spectral regions, to automatically map the solar flux intensity over the entire work volume of the chamber, and to provide the capability for leak detection. The first year's work, which provides a vertically mobile viewing platform equipped with stereo cameras, will be discussed. Design constraints and system implementation approaches mandated by the requirements of thermal vacuum operation will be emphasized.

Mcaffee, D. A.↗

Nickel hydrogen multicell common pressure vessel battery development update

The technology background and design qualification of the multicell common pressure vessel nickel hydrogen battery are described. The results of full flight qualification, including random vibration at 19.5 g for two minutes in each axis, electrical characterization in a thermal vacuum chamber, and mass spectroscopy vessel leak detection are reviewed and 12.7 cm qualification and 25.4 cm design adaptation are discussed.

Zagrodnik, Jeffrey P.↗

Hydrazine-Vapor Samplers

Active sampling unit capable of detecting hydrazine and monomethyl hydrazine vapors at levels as low as 10 ppb in air developed. Includes detachable badge holder and pump which draws air through badge holder at selectable rate of 1 or 2 L/min. Coated strip in each badge designed to align with air passage in badge holder. Two types of badge holders constructed: one has open-face design for general monitoring of air in open spaces, while other has closed-face design with viewing window and intended for sampling through small openings to detect leaks.

Young, Rebecca↗

Mass-Flow-Meter Leak-Testing System

Improved leak-testing system incorporates mass-flow meter as primary sensor for measurement of leakage rate. System easier to use and more reliable and enables leak tests to be completed in less time. Produces test data more plentiful, more accurate, and better suited to leak detection and diagnosis. Operates over range of test conditions, including pressures from atmospheric to 1,000 psi, temperatures from 50 to 120 degrees F and volumes from less than 1 in.(sup3) to 22 in.(sup3). Sensitive enough to measure absorbed gas seeping from O-ring seals after test pressure released.

Sorensen, Eric B.↗

Microfabricated Chemical Sensors for Safety and Emission Control Applications

Chemical sensor technology is being developed for leak detection, emission monitoring, and fire safety applications. The development of these sensors is based on progress in two types of technology: 1) Micromachining and microfabrication (MicroElectroMechanical Systems (MEMS)-based) technology to fabricate miniaturized sensors. 2) The development of high temperature semiconductors, especially silicon carbide. Using these technologies, sensors to measure hydrogen, hydrocarbons, nitrogen oxides, carbon monoxide, oxygen, and carbon dioxide are being developed. A description is given of each sensor type and its present stage of development. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

Hunter, G. W.↗

Study Methods to Characterize and Implement Thermography Nondestructive Evaluation (NDE)

The limits and conditions under which an infrared thermographic nondestructive evaluation can be utilized to assess the quality of aerospace hardware is demonstrated in this research effort. The primary focus of this work is on applying thermography to the inspection of advanced composite structures such as would be found in the International Space Station Instrumentation Racks, Space Shuttle Cargo Bay Doors, Bantam RP-1 tank or RSRM Nose Cone. Here, the detection of delamination, disbond, inclusion and porosity type defects are of primary interest. In addition to composites, an extensive research effort has been initiated to determine how well a thermographic evaluation can detect leaks and disbonds in pressurized metallic systems "i.e. the Space Shuttle Main Engine Nozzles". In either case, research into developing practical inspection procedures was conducted and thermographic inspections were performed on a myriad of test samples, subscale demonstration articles and "simulated" flight hardware. All test samples were fabricated as close to their respective structural counterparts as possible except with intentional defects for NDE qualification. As an added benefit of this effort to create simulated defects, methods were devised for defect fabrication that may be useful in future NDE qualification ventures.

Walker, James L.↗

Analytical Assessment of a Gross Leakage Event Within the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS)

Results of the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS) gross leakage analysis are presented for evaluating total leakage flowrates and volume discharge caused by a gross leakage event (i.e. open boundary condition). A Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA/FLUINT) thermal hydraulic mathematical model (THMM) representing the Node 2 IATCS was developed to simulate system performance under steady-state nominal conditions as well as the transient flow effects resulting from an open line exposed to ambient. The objective of the analysis was to determine the adequacy of the leak detection software in limiting the quantity of fluid lost during a gross leakage event to within an acceptable level.

Holt, James M.↗

SiC-Based Gas Sensor Development

Silicon carbide based Schottky diode gas sensors are being developed for applications such as emission measurements and leak detection. The effects of the geometry of the tin oxide film in a Pd/SnO2/SiC structure will be discussed as well as improvements in packaging SiC-based sensors. It is concluded that there is considerable versatility in the formation of SiC-based Schottky diode gas sensing structures which will potentially allow the fabrication of a SiC-based gas sensor array for a variety of gases and temperatures.

Hunter, G. W.↗

Analytical Assessment of a Gross Leakage Event Within the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS)

Results of the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS) gross leakage analysis are presented for evaluating total leakage flow rates and volume discharge caused by a gross leakage event (i.e. open boundary condition). A Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA85/FLUINT) thermal hydraulic mathematical model (THMM) representing the Node 2 IATCS was developed to simulate system performance under steady-state nominal conditions as well as the transient flow effect resulting from an open line exposed to ambient. The objective of the analysis was to determine the adequacy of the leak detection software in limiting the quantity of fluid lost during a gross leakage event to within an acceptable level.

Holt, James M.↗